ML21316A206: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
(2 intermediate revisions by the same user not shown)
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 16, 2021 Ms. Kimberly Manzione Licensing Manager Holtec International Holtec Technology Campus One Holtec Boulevard Camden, NJ 08104
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Ms. Kimberly Manzione Licensing Manager Holtec International Holtec Technology Campus One Holtec Boulevard Camden, NJ 08104


==SUBJECT:==
==SUBJECT:==
Line 22: Line 22:


==Dear Ms. Manzione:==
==Dear Ms. Manzione:==
As requested in your application dated December 7, 2018, and supplemented on June 28, 2019, October 10, 2019, December 12, 2019, June 1, 2020, June 11, 2020, November 13, 2020, and November 24, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML18345A178, ML19184A232, ML19288A089, ML19350A576, ML20153A768, ML20163A713, ML20318A321, and ML20329A321), enclosed are the renewed initial certificate and renewed Amendment Nos. 1, 2, and 3 of Certificate of Compliance (CoC)
As requested in your application dated December 7, 2018, and supplemented on June 28, 2019, October 10, 2019, December 12, 2019, June 1, 2020, June 11, 2020, November 13, 2020, and November 24, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML18345A178, ML19184A232, ML19288A089, ML19350A576, ML20153A768, ML20163A713, ML20318A321, and ML20329A321), enclosed are the renewed initial certificate and renewed Amendment Nos. 1, 2, and 3 of Certificate of Compliance (CoC)
No. 1008 for the HI-STAR 100 Cask System. The certificates have been renewed for an additional 40-year term that expires on October 4, 2059, in accordance with the provisions of Title 10 of the Code of Federal Regulations, Part 72, Section 72.40 (10 CFR 72.240). The renewal of these certificates constitutes the U.S. Nuclear Regulatory Commissions (NRC) approval for continued use of the HI-STAR 100 Cask System for storage of spent nuclear fuel under the general licensing provisions of 10 CFR 72.210 subject to the conditions in the renewed certificate. These conditions require the implementation of an approved aging management program (AMP) to ensure that structures, systems, and components important to safety will continue to perform their intended functions during the extended storage period authorized by the renewal.
No. 1008 for the HI-STAR 100 Cask System. The certificates have been renewed for an additional 40-year term that expires on October 4, 2059, in accordance with the provisions of Title 10 of the Code of Federal Regulations, Part 72, Section 72.40 (10 CFR 72.240). The renewal of these certificates constitutes the U.S. Nuclear Regulatory Commissions (NRC) approval for continued use of the HI-STAR 100 Cask System for storage of spent nuclear fuel under the general licensing provisions of 10 CFR 72.210 subject to the conditions in the renewed certificate. These conditions require the implementation of an approved aging management program (AMP) to ensure that structures, systems, and components important to safety will continue to perform their intended functions during the extended storage period authorized by the renewal.
As stated in the Federal Register (86 FR 54341, October 1, 2021), the effective date of this CoC is December 15, 2021. The NRC staffs final safety evaluation report for the renewal of the certificates, and the corresponding technical specifications for each renewed certificate are also
As stated in the Federal Register (86 FR 54341, October 1, 2021), the effective date of this CoC is December 15, 2021. The NRC staffs final safety evaluation report for the renewal of the certificates, and the corresponding technical specifications for each renewed certificate are also November 16, 2021 K. Manzione 2 enclosed. If you have any questions regarding the renewal of these certificates, please contact Ms. Kristina Banovac at (301) 415-7116 or Kristina.Banovac@nrc.gov.
 
Sincerely, John B. McKirgan, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1008 CAC/EPID Nos.: 001028/L-2018-RNW-0030
K. Manzione                                   2 enclosed. If you have any questions regarding the renewal of these certificates, please contact Ms. Kristina Banovac at (301) 415-7116 or Kristina.Banovac@nrc.gov.
Sincerely, Signed by McKirgan, John on 11/16/21 John B. McKirgan, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1008 CAC/EPID Nos.: 001028/L-2018-RNW-0030


==Enclosures:==
==Enclosures:==
 
See Attached List Signed by McKirgan, John on 11/16/21
See Attached List


ML21316A192 (pkg), ML21316A206 (letter)
ML21316A192 (pkg), ML21316A206 (letter)
OFFICE NMSS/DFM/STLB         NMSS/DFM/STLB       NMSS/DFM/STLB NAME     KBanovac           WWheatley           JMcKirgan DATE     11/15/2021         11/16/2021         11/16/2021 OFFICE NMSS/DFM/STLB         NMSS/DFM/STLB NAME     KBanovac           JMcKirgan DATE     11/16/2021         11/16/2021 List of Enclosures Note: All enclosures are located in the Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML21316A192
OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NAME KBanovac WWheatley JMcKirgan DATE 11/15/2021 11/16/2021 11/16/2021 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NAME KBanovac JMcKirgan DATE 11/16/2021 11/16/2021 List of Enclosures Note: All enclosures are located in the Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML21316A192
: 1. Renewed CoC No. 1008, Renewed Amendment No. 0 (ML21316A193)
: 1. Renewed CoC No. 1008, Renewed Amendment No. 0 (ML21316A193)
: 2. Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 0 (ML21316A194)
: 2. Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 0 (ML21316A194)
Line 45: Line 41:
: 8. Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 2 (ML21316A200)
: 8. Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 2 (ML21316A200)
: 9. Technical Specifications (Appendix B) for CoC No. 1008, Renewed Amendment No. 2 (ML21316A201)
: 9. Technical Specifications (Appendix B) for CoC No. 1008, Renewed Amendment No. 2 (ML21316A201)
: 10. Renewed CoC No. 1008, Renewed Amendment No. 3 (ML21316A202)
: 11. Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 3 (ML21316A203)
: 12. Technical Specifications (Appendix B) for CoC No. 1008, Renewed Amendment No. 3 (ML21316A204)
: 13. Final Safety Evaluation Report for Renewed CoC No. 1008, Amendment Nos. 0, 1, 2, and 3 (ML21316A205)


ML21316A192; Ltr ML21316A206 OFFICE             NMSS/DFM/STLB         NMSS/DFM/STLB   NMSS/DFM/STLB   NMSS/DFM/STLB NAME               KBanovac         KB WWheatley     WW JMcKirgan   JM KBanovac     KB DATE               Nov 15, 2021         Nov 16, 2021     Nov 16, 2021   Nov 16, 2021 OFFICE             NMSS/DFM/STLB NAME               JMcKirgan         JM DATE               Nov 16, 2021}}
10.Renewed CoC No. 1008, Renewed Amendment No. 3 (ML21316A202) 11.Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 3 (ML21316A203) 12.Technical Specifications (Appendix B) for CoC No. 1008, Renewed Amendment No. 3 (ML21316A204)
 
13.Final Safety Evaluation Report for Renewed CoC No. 1008, Amendment Nos. 0, 1, 2, and 3 (ML21316A205)
 
ML21316A192; Ltr ML21316A206 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NAME KBanovac KB WWheatley WW JMcKirgan JM KBanovac KB DATE Nov 15, 2021 Nov 16, 2021 Nov 16, 2021 Nov 16, 2021 OFFICE NMSS/DFM/STLB NAME JMcKirgan JM DATE Nov 16, 2021}}

Latest revision as of 11:58, 19 November 2024

Transmittal Letter, Issuance of Renewed CoC No. 1008, HI-STAR 100 Cask System
ML21316A206
Person / Time
Site: 07201008
Issue date: 11/16/2021
From: John Mckirgan
Storage and Transportation Licensing Branch
To: Manzione K
Holtec
Kristina Banovac NMSS/DFM/STL 3014157116
Shared Package
ML21316A192 List:
References
Download: ML21316A206 (5)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Ms. Kimberly Manzione Licensing Manager Holtec International Holtec Technology Campus One Holtec Boulevard Camden, NJ 08104

SUBJECT:

RENEWAL OF INITIAL CERTIFICATE AND AMENDMENT NOS. 1, 2, AND 3 OF THE CERTIFICATE OF COMPLIANCE NO. 1008 FOR THE HI-STAR 100 CASK SYSTEM (CAC/EPID NOS. 001028/L-2018-RNW-0030)

Dear Ms. Manzione:

As requested in your application dated December 7, 2018, and supplemented on June 28, 2019, October 10, 2019, December 12, 2019, June 1, 2020, June 11, 2020, November 13, 2020, and November 24, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML18345A178, ML19184A232, ML19288A089, ML19350A576, ML20153A768, ML20163A713, ML20318A321, and ML20329A321), enclosed are the renewed initial certificate and renewed Amendment Nos. 1, 2, and 3 of Certificate of Compliance (CoC)

No. 1008 for the HI-STAR 100 Cask System. The certificates have been renewed for an additional 40-year term that expires on October 4, 2059, in accordance with the provisions of Title 10 of the Code of Federal Regulations, Part 72, Section 72.40 (10 CFR 72.240). The renewal of these certificates constitutes the U.S. Nuclear Regulatory Commissions (NRC) approval for continued use of the HI-STAR 100 Cask System for storage of spent nuclear fuel under the general licensing provisions of 10 CFR 72.210 subject to the conditions in the renewed certificate. These conditions require the implementation of an approved aging management program (AMP) to ensure that structures, systems, and components important to safety will continue to perform their intended functions during the extended storage period authorized by the renewal.

As stated in the Federal Register (86 FR 54341, October 1, 2021), the effective date of this CoC is December 15, 2021. The NRC staffs final safety evaluation report for the renewal of the certificates, and the corresponding technical specifications for each renewed certificate are also November 16, 2021 K. Manzione 2 enclosed. If you have any questions regarding the renewal of these certificates, please contact Ms. Kristina Banovac at (301) 415-7116 or Kristina.Banovac@nrc.gov.

Sincerely, John B. McKirgan, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1008 CAC/EPID Nos.: 001028/L-2018-RNW-0030

Enclosures:

See Attached List Signed by McKirgan, John on 11/16/21

ML21316A192 (pkg), ML21316A206 (letter)

OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NAME KBanovac WWheatley JMcKirgan DATE 11/15/2021 11/16/2021 11/16/2021 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NAME KBanovac JMcKirgan DATE 11/16/2021 11/16/2021 List of Enclosures Note: All enclosures are located in the Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML21316A192

1. Renewed CoC No. 1008, Renewed Amendment No. 0 (ML21316A193)
2. Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 0 (ML21316A194)
3. Technical Specifications (Appendix B) for CoC No. 1008, Renewed Amendment No. 0 (ML21316A195)
4. Renewed CoC No. 1008, Renewed Amendment No. 1 (ML21316A196)
5. Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 1 (ML21316A197)
6. Technical Specifications (Appendix B) for CoC No. 1008, Renewed Amendment No. 1 (ML21316A198)
7. Renewed CoC No. 1008, Renewed Amendment No. 2 (ML21316A199)
8. Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 2 (ML21316A200)
9. Technical Specifications (Appendix B) for CoC No. 1008, Renewed Amendment No. 2 (ML21316A201)

10.Renewed CoC No. 1008, Renewed Amendment No. 3 (ML21316A202) 11.Technical Specifications (Appendix A) for CoC No. 1008, Renewed Amendment No. 3 (ML21316A203) 12.Technical Specifications (Appendix B) for CoC No. 1008, Renewed Amendment No. 3 (ML21316A204)

13.Final Safety Evaluation Report for Renewed CoC No. 1008, Amendment Nos. 0, 1, 2, and 3 (ML21316A205)

ML21316A192; Ltr ML21316A206 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NAME KBanovac KB WWheatley WW JMcKirgan JM KBanovac KB DATE Nov 15, 2021 Nov 16, 2021 Nov 16, 2021 Nov 16, 2021 OFFICE NMSS/DFM/STLB NAME JMcKirgan JM DATE Nov 16, 2021