Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5018086 Page 1 of 2 June 23, 2021 Shana Helton - Director Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No.:
72-1008, Certificate of Compliance (CoC) No. 1008 72-1014, Certificate of Compliance (CoC) No. 1014 72-1032, Certificate of Compliance (CoC) No. 1032 72-1040, Certificate of Compliance (CoC) No. 1040
Subject:
Submittal of Holtec Position Paper DS-481, Consideration of Transient Loadings during Short Term Operations
Reference:
[1] Holtec Letter 5018082, Extreme Environmental Phenomena During Short Term Operations Within 10CFR72 Jurisdiction, to C. Regan (NRC) from S. Anton (Holtec) dated May 12, 2021
Dear Ms. Helton:
Holtec previously submitted a letter requesting clarification on the consideration of extreme environmental phenomena during short term operations (STO) within Part 72 jurisdiction [1].
We understand that the staff is working to schedule a public meeting to discuss NRCs position.
To facilitate discussion at that meeting, Holtec provides the attached position paper which explains our position on the issue.
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5018086 Page 2 of 2 If you have any questions, please contact me at (856) 296-9219 or s.anton@holtec.com.
Sincerely, Stefan Anton, Dr.-Ing.
Vice President of Engineering Holtec International cc:(via email)
John McKirgan (NRC)
Paul Peduzzi (NRC)
Chris Regan (NRC)
Attachments: : Holtec Position Paper DS-481, Consideration of Transient Loadings during Short Term Operations (Proprietary) : Affidavit Pursuant to 10CFR2.390 (Non-proprietary)