Line 16: |
Line 16: |
|
| |
|
| =Text= | | =Text= |
| {{#Wiki_filter:INDIANAMICHIGANPOWERA unit of American Electric PowerIndiana Michigan PowerCook Nuclear PlantOne Cook PlaceBridgman, MI 49106Indiana Michiga nPower.com AEP NRC 2015-7110 CFR 72.212July 30, 2015Docket Nos.: 50-31550-31672-072U. S. Nuclear Regulatory Commission ATTN: Document Control DeskDirector, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Washington, D.C. 20555-0001 Donald C. Cook Nuclear Plant Units 1 and 2INDEPENDENT SPENT FUEL STORAGE INSTALLATION REGISTRATION OF DRY SPENT FUEL STORAGE CASKPursuant to 10 CFR 72.212(b)(2) | | {{#Wiki_filter:INDIANA MICHIGAN POWERA unit of American Electric Power Indiana Michigan Power Cook Nuclear Plant One Cook Place Bridgman, MI 49106 Indiana Michiga nPower.com AEP NRC 2015-71 10 CFR 72.212 July 30, 2015 Docket Nos.: 50-315 50-316 72-072 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Washington, D.C. 20555-0001 Donald C. Cook Nuclear Plant Units 1 and 2 INDEPENDENT SPENT FUEL STORAGE INSTALLATION REGISTRATION OF DRY SPENT FUEL STORAGE CASK Pursuant to 10 CFR 72.212(b)(2) |
| Indiana Michigan Power Company (I&M), the Licensee forDonald C. Cook Nuclear Plant (CNP) Units 1 and 2, is providing the following registration information for the use of dry spent fuel storage casks to store used fuel under I&M's10 CFR 72.210 General License at the CNP Independent Spent Fuel Storage Installation (ISFSI).Licensee Name:Licensee Address:Reactor License No.:Reactor Docket Nos.:ISFSI Docket No.:Indiana Michigan Power Company1 Cook Place, Bridgman, MI 49106DPR-58 and DPR-7450-315 and 50-31672-072The following casks were placed in service on the dates indicated below:Identification Nos.:Cask Certificate: | | Indiana Michigan Power Company (I&M), the Licensee for Donald C. Cook Nuclear Plant (CNP) Units 1 and 2, is providing the following registration information for the use of dry spent fuel storage casks to store used fuel under I&M's 10 CFR 72.210 General License at the CNP Independent Spent Fuel Storage Installation (ISFSI).Licensee Name: Licensee Address: Reactor License No.: Reactor Docket Nos.: ISFSI Docket No.: Indiana Michigan Power Company 1 Cook Place, Bridgman, MI 49106 DPR-58 and DPR-74 50-315 and 50-316 72-072 The following casks were placed in service on the dates indicated below: Identification Nos.: Cask Certificate: |
| Cask Model No.:Date in Service:Identification Nos.:Cask Certificate: | | Cask Model No.: Date in Service: Identification Nos.: Cask Certificate: |
| Cask Model No.:Date in Service:HI-STORM | | Cask Model No.: Date in Service: HI-STORM Overpack, Serial No. 770 Multi-Purpose Canister (MpC) Type 32, Serial No. 320 No.: 72-1 014, Amendment No. 5 HI-STORM 100S, Version B July 11, 2015 HI-STORM Overpack, Serial No. 771 MPC Type 32, Serial No. 321 No.: 72-1014, Amendment No. 5 HI-STORM 100S, Version B July 18, 2015-1/ |
| : Overpack, Serial No. 770Multi-Purpose Canister (MpC) Type 32, Serial No. 320No.: 72-1 014, Amendment No. 5HI-STORM 100S, Version BJuly 11, 2015HI-STORM
| | U. S. Nuclear Regulatory Commission Page 2 AEP-NRC-201 5-71 Identification Nos.: Cask Certificate: |
| : Overpack, Serial No. 771MPC Type 32, Serial No. 321No.: 72-1014, Amendment No. 5HI-STORM 100S, Version BJuly 18, 2015-1/
| | Cask Model No.: Date in Service: HI-STORM Overpack, Serial No. 772 MPC Type 32, Serial No. 322 No.: 72-1014, Amendment No. 5 HI-STORM I00S, Version B July 25, 2015 This letter contains no new or revised regulatory commitments. |
| U. S. Nuclear Regulatory Commission Page 2AEP-NRC-201 5-71Identification Nos.:Cask Certificate: | | Should you have any questions, please contact Mr. Michael K. Scarpello, Regulatory Affairs Manager, at (269) 466-2649.Sincerely, Joel P. Gebbie Site Vice President KMH/ams c: A.W. Dietrich, NRC Washington, DC R. A. Edwards, Ill, NRC Region III C. Haney, Director Office of Nuclear Material Safety and Safeguards J. T. King, MPSC P. L. Louden, Director Division of Nuclear Materials Safety, NRC Region Ill MDEQ -RMD/RPS NRC Resident Inspector R. J. Orlikowski, Chief Materials Control, ISESI, and Decommissioning Branch, NRC Region A. J. Williamson, Ft. Wayne AEP}} |
| Cask Model No.:Date in Service:HI-STORM | |
| : Overpack, Serial No. 772MPC Type 32, Serial No. 322No.: 72-1014, Amendment No. 5HI-STORM I00S, Version BJuly 25, 2015This letter contains no new or revised regulatory commitments.
| |
| Should you have any questions, please contact Mr. Michael K. Scarpello, Regulatory Affairs Manager, at (269) 466-2649. | |
| Sincerely, Joel P. GebbieSite Vice President KMH/amsc: A.W. Dietrich, NRC Washington, DCR. A. Edwards, Ill, NRC Region IIIC. Haney, Director Office of Nuclear Material Safety and Safeguards J. T. King, MPSCP. L. Louden, Director Division of Nuclear Materials Safety, NRC Region IllMDEQ -RMD/RPSNRC Resident Inspector R. J. Orlikowski, Chief Materials | |
| : Control, ISESI, and Decommissioning Branch,NRC Region A. J. Williamson, Ft. Wayne AEP}}
| |
|
---|
Category:Letter
MONTHYEARML24309A2872024-11-0404 November 2024 International, HI-STORM 100 Amendment 19 Responses to Requests for Additional Information IR 05000315/20240032024-10-31031 October 2024 Integrated Inspection Report 05000315/2024003 05000316/2024003 07200072/2024001 and Exercise of Enforcement Discretion AEP-NRC-2024-77, U2C28 Steam Generator Tube Inspection Report2024-10-21021 October 2024 U2C28 Steam Generator Tube Inspection Report AEP-NRC-2024-80, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask2024-10-15015 October 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask ML24274A3032024-10-0909 October 2024 Amendment 19 to Certificate of Compliance 1014 for Hi-Storm 100 Multi-Purpose Canister Storage System Request for Additional Information ML24240A1182024-10-0808 October 2024 0 Issuance Letter Amendment 18 to Renewed Certificate of Compliance No. 1014 for the HI-STORM 100 Cask System SVP-24-059, Correction to Registration of Use of Casks to Store Spent Fuel2024-10-0404 October 2024 Correction to Registration of Use of Casks to Store Spent Fuel AEP-NRC-2024-79, Unit 2, Independent Spent Fuel Storage Installation - Registration of Dry Spent Storage Cask2024-09-26026 September 2024 Unit 2, Independent Spent Fuel Storage Installation - Registration of Dry Spent Storage Cask AEP-NRC-2024-78, Reply to a Notice of Violation: EA-24-0472024-09-23023 September 2024 Reply to a Notice of Violation: EA-24-047 ML24263A2062024-09-19019 September 2024 Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for LaSalle County Station - Holtec MPC-68MCBS NL-24-0351, – ISFSI - Registration of Spent Fuel Cask Use2024-09-13013 September 2024 – ISFSI - Registration of Spent Fuel Cask Use 05000316/LER-2024-002-01, Manual Reactor Trip Following Rapid Downpower for Steam Leak2024-09-12012 September 2024 Manual Reactor Trip Following Rapid Downpower for Steam Leak IR 05000315/20244022024-09-10010 September 2024 Security Baseline Inspection Report 05000315/2024402 and 05000316/2024402, Independent Spent Fuel Storage Installation Security Inspection Report 07200072/2024401 AEP-NRC-2024-69, Core Operating Limits Report2024-09-0909 September 2024 Core Operating Limits Report IR 05000315/20243012024-09-0505 September 2024 NRC Initial License Examination Report 05000315/2024301 and 05000316/2024301 ML24225A0022024-09-0303 September 2024 Issuance of Amendment Nos. 363 and 344 Revising Technical Specifications Section 3.8.1, AC Sources-Operating, for a One-Time Extension of a Completion Time IR 05000315/20240112024-08-30030 August 2024 NRC Inspection Report 05000315/2024011 and 05000316/2024011 and Notice of Violation AEP-NRC-2024-51, Annual Report of Loss-Of-Coolant Accident Evaluation Model Changes2024-08-28028 August 2024 Annual Report of Loss-Of-Coolant Accident Evaluation Model Changes AEP-NRC-2024-76, Unit 2 - Supplement to License Amendment Request for One-Time Extension of Completion Time for Inoperable AC Source - Operating2024-08-28028 August 2024 Unit 2 - Supplement to License Amendment Request for One-Time Extension of Completion Time for Inoperable AC Source - Operating 05000316/LER-2024-003, Plant Shutdown Required by Technical Specifications Due to Reactor Coolant System Identified Leakage2024-08-22022 August 2024 Plant Shutdown Required by Technical Specifications Due to Reactor Coolant System Identified Leakage IR 05000315/20240052024-08-21021 August 2024 Updated Inspection Plan for Donald C. Cook Nuclear Plant, Units 1 and 2 (Report 05000315/2024005 and 05000316/2024005) AEP-NRC-2024-61, Unit 2 - Response to Request for Additional Information for Neutron Flux Instrumentation License Amendment Request2024-08-15015 August 2024 Unit 2 - Response to Request for Additional Information for Neutron Flux Instrumentation License Amendment Request ML24222A8592024-08-0909 August 2024 International - HI-STORM 100 Multipurpose Canister Storage System Amendment 19 Request ML24221A2702024-08-0808 August 2024 Unit 2 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Storage Cask AEP-NRC-2024-62, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-08-0707 August 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask ML24256A1482024-08-0202 August 2024 2024 Post Examination Submittal Letter SVP-24-048, Registration of Use of Casks to Store Spent Fuel2024-07-31031 July 2024 Registration of Use of Casks to Store Spent Fuel AEP-NRC-2024-47, Form OAR-1, Owners Activity Report2024-07-30030 July 2024 Form OAR-1, Owners Activity Report ML24178A4312024-07-29029 July 2024 Issuance of Certificate of Compliance No. 1014, Amendment No. 16 for the HI-STORM 100 Cask System, Cover Letter ML24183A0162024-07-25025 July 2024 Review of Reactor Vessel Material Surveillance Program Capsule W Technical Report ML24169A2142024-07-25025 July 2024 Issuance of Amendment No. 362 Regarding Change to Technical Specification 3.4.12, Low Temperature Overpressure Protection System IR 05000315/20240022024-07-24024 July 2024 Integrated Inspection Report 05000315/2024002 and 05000316/2024002 ML24197A1262024-07-15015 July 2024 Unit 2 - Request for Additional Information (RAI) for License Amendment Request for One-Time Extension of Completion Time for Inoperable AC Source - Operating 05000316/LER-2024-002, Manual Reactor Trip Following Rapid Downpower for Steam Leak2024-07-15015 July 2024 Manual Reactor Trip Following Rapid Downpower for Steam Leak ML24191A0692024-07-0909 July 2024 Operator Licensing Examination Approval - Donald C. Cook Nuclear Power Plant, July 2024 AEP-NRC-2024-56, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-07-0808 July 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask AEP-NRC-2024-48, Response to Request for Additional Information (RAI) for License Amendment Request for One-Time Extension of Completion Time for Inoperable AC Source - Operating2024-07-0202 July 2024 Response to Request for Additional Information (RAI) for License Amendment Request for One-Time Extension of Completion Time for Inoperable AC Source - Operating SVP-24-040, Registration of Use of Casks to Store Spent Fuel2024-06-25025 June 2024 Registration of Use of Casks to Store Spent Fuel NL-24-0199, Request for Specific Exemption2024-06-25025 June 2024 Request for Specific Exemption ML24176A1012024-06-21021 June 2024 57143-EN 57143 - Paragon Energy Solutions - Update 1 (Final) - 10CFR Part 21 Final Notification: P21-05242024-FN, Rev. 0 NL-24-0243, Registration of Spent Fuel Cask Use2024-06-18018 June 2024 Registration of Spent Fuel Cask Use AEP-NRC-2024-45, Report Per Technical Specification 5.6.6 for Inoperability of Post Accident Monitoring Neutron Flux Monitoring2024-06-13013 June 2024 Report Per Technical Specification 5.6.6 for Inoperability of Post Accident Monitoring Neutron Flux Monitoring ML24163A0132024-06-12012 June 2024 Request for Information for the NRC Age-Related Degradation Inspection: Inspection Report 05000315/2024012 and 05000316/2024012 ML24183A2752024-05-30030 May 2024 Registration of Use of Casks to Store Spent Fuel ML24159A2522024-05-30030 May 2024 10 CFR 50.71(e) Update and Related Site Change Reports SVPLTR 24-0019, Registration of Use of Casks to Store Spent Fuel2024-05-23023 May 2024 Registration of Use of Casks to Store Spent Fuel AEP-NRC-2024-23, Core Operating Limits Report2024-05-23023 May 2024 Core Operating Limits Report ML24145A0432024-05-23023 May 2024 Registration of Use of Casks to Store Spent Fuel 10 CFR 72.212 ML24143A0752024-05-22022 May 2024 Re. Ginna Nuclear Power Plant and Independent Spent Fuel Storage Installation (ISFSI) Registration for Use of General License ISFSI Casks 05000316/LER-2024-001, Reactor Trip Due to Main Turbine Trip from a High-High Thrust Bearing Position Trip2024-05-20020 May 2024 Reactor Trip Due to Main Turbine Trip from a High-High Thrust Bearing Position Trip 2024-09-09
[Table view] Category:License-Application for Dry Cask ISFSI DKT 72
MONTHYEARML24100A7242024-01-0303 January 2024 08. Hs A19 Proposed CoC (Compiled 2023-0313) ML22321A2772022-11-17017 November 2022 Renewed Facility License No. DPR-26 NL-22-0718, Registration of Spent Fuel Cask Use2022-09-14014 September 2022 Registration of Spent Fuel Cask Use ML22245A1062022-09-0202 September 2022 Attachment 2: Proposed Certificate of Compliance No. 1014, Appendix a, Technical Specifications for the HI-Storm 100 Cask System ML22028A3832022-01-28028 January 2022 Attachment 11: Holtec International, HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix D Reorganization Evaluation Form ML22028A3822022-01-28028 January 2022 Attachment 10: Holtec International, HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix C Reorganization Evaluation Form ML22028A3812022-01-28028 January 2022 Attachment 9: Holtec International, HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix B Reorganization Evaluation Form ML22028A3802022-01-28028 January 2022 Attachment 8: Holtec International, HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix a Reorganization Evaluation Form ML22028A3792022-01-28028 January 2022 Attachment 7: Holtec International, HI-STORM 100 Amendment 16 Certificate of Compliance Reorganization Evaluation Form ML22028A3782022-01-28028 January 2022 Attachment 6: Holtec International, HI-STORM 100 Amendment 16 Certificate of Compliance Reorganization Matrix ML22028A3762022-01-28028 January 2022 Attachment 4: Holtec International, Appendix C Inspections, Tests, and Evaluations for the HI-Storm 100 Cask System ML22028A3752022-01-28028 January 2022 Attachment 3: Holtec International, Appendix B Technical Specifications for the HI-Storm 100 Cask System ML22028A3742022-01-28028 January 2022 Attachment 2: Holtec International, Appendix a Inspections, Tests, and Evaluations for the HI-Storm 100 Cask System ML22028A3732022-01-28028 January 2022 Attachment 1: Holtec International, Amendment 16 Certificate of Compliance for Spent Fuel Storage Casks ML22028A3772022-01-28028 January 2022 Attachment 5: Holtec International, Appendix D Technical Specifications for the HI-Storm 100 Cask System ML21349B4202021-12-15015 December 2021 Attachment 1: Proposed HI-STORM 100 CoC Amendment 18 (non-proprietary) ML21211A6062021-07-30030 July 2021 Attachment 2: Proposed Coc No. 72-1014 ML21211A6052021-07-30030 July 2021 Attachment 1: HI-STORM 100 Amendment 17 Summary of Proposed Changes ML21211A6072021-07-30030 July 2021 Attachment 3: HI-STORM 100 FSAR Proposed Revision 23 Revised Pages ML21118A8682021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix D, Approved Contents and Design Features for the Hi-Storm 100S Version E Cask and Hi-Trac Ms ML21113A2032021-04-23023 April 2021 Attachment 1 - Certificate of Compliance Renewal Application for the HI-STORM 100 Dry Storage System ML21068A3632021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance ML21068A3972021-03-0909 March 2021 Attachment 35 - HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix D Reorganization Evaluation Form (Non-Proprietary) ML21068A3962021-03-0909 March 2021 Attachment 34 - HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix C Reorganization Evaluation Form (Non-Proprietary) ML21068A3952021-03-0909 March 2021 Attachment 33 - HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix B-100U Reorganization Evaluation Form (Non-Proprietary) ML21068A3942021-03-0909 March 2021 Attachment 32 - HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix A-100U Reorganization Evaluation Form (Non-Proprietary) ML21068A3932021-03-0909 March 2021 Attachment 31 - HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix B Reorganization Evaluation Form (Non-Proprietary) ML21068A3922021-03-0909 March 2021 Attachment 30 - HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix a Reorganization Evaluation Form (Non-Proprietary) ML21068A3912021-03-0909 March 2021 Attachment 29 - HI-STORM 100 Amendment 16 Certificate of Compliance Reorganization Evaluation Form (Non-Proprietary) ML21068A3902021-03-0909 March 2021 Attachment 28 - HI-STORM 100 Amendment 16 Certificate of Compliance Reorganization Matrix (Non-Proprietary) ML21068A3892021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix D Reorganization ML21068A3882021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix C Reorganization ML21068A3872021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix B-100U Reorganization ML21068A3862021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix A-100U Reorganization ML21068A3852021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix B Reorganization ML21068A3842021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix a Reorganization ML21068A3832021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance Reorganization ML21068A3722021-03-0909 March 2021 HI-STORM 100 FSAR Proposed Revision 21 Revised Pages ML21068A3702021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix D ML21068A3692021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix C ML21068A3682021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix B-100U ML21068A3672021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix A-100U ML21068A3662021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix B ML21068A3622021-03-0909 March 2021 HI-STORM 100 Amendment 16 Summary of Proposed Changes ML21068A3642021-03-0909 March 2021 HI-STORM 100 Amendment 16 Certificate of Compliance, Appendix a ML20290A8242020-10-16016 October 2020 Certificate of Compliance Renewal Application for the HI-STORM 100 Dry Storage System LR-N19-0029, Spent Fuel Cask Registration2019-02-25025 February 2019 Spent Fuel Cask Registration BVY 18-028, Registration of Spent Fuel Cask Use2018-07-0505 July 2018 Registration of Spent Fuel Cask Use NL-18-0627, Registration of Spent Fuel Casks2018-05-15015 May 2018 Registration of Spent Fuel Casks GO2-18-045, Registration of Spent Fuel Cask Use2018-03-21021 March 2018 Registration of Spent Fuel Cask Use 2024-01-03
[Table view] |
Text
INDIANA MICHIGAN POWERA unit of American Electric Power Indiana Michigan Power Cook Nuclear Plant One Cook Place Bridgman, MI 49106 Indiana Michiga nPower.com AEP NRC 2015-71 10 CFR 72.212 July 30, 2015 Docket Nos.: 50-315 50-316 72-072 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Washington, D.C. 20555-0001 Donald C. Cook Nuclear Plant Units 1 and 2 INDEPENDENT SPENT FUEL STORAGE INSTALLATION REGISTRATION OF DRY SPENT FUEL STORAGE CASK Pursuant to 10 CFR 72.212(b)(2)
Indiana Michigan Power Company (I&M), the Licensee for Donald C. Cook Nuclear Plant (CNP) Units 1 and 2, is providing the following registration information for the use of dry spent fuel storage casks to store used fuel under I&M's 10 CFR 72.210 General License at the CNP Independent Spent Fuel Storage Installation (ISFSI).Licensee Name: Licensee Address: Reactor License No.: Reactor Docket Nos.: ISFSI Docket No.: Indiana Michigan Power Company 1 Cook Place, Bridgman, MI 49106 DPR-58 and DPR-74 50-315 and 50-316 72-072 The following casks were placed in service on the dates indicated below: Identification Nos.: Cask Certificate:
Cask Model No.: Date in Service: Identification Nos.: Cask Certificate:
Cask Model No.: Date in Service: HI-STORM Overpack, Serial No. 770 Multi-Purpose Canister (MpC) Type 32, Serial No. 320 No.: 72-1 014, Amendment No. 5 HI-STORM 100S, Version B July 11, 2015 HI-STORM Overpack, Serial No. 771 MPC Type 32, Serial No. 321 No.: 72-1014, Amendment No. 5 HI-STORM 100S, Version B July 18, 2015-1/
U. S. Nuclear Regulatory Commission Page 2 AEP-NRC-201 5-71 Identification Nos.: Cask Certificate:
Cask Model No.: Date in Service: HI-STORM Overpack, Serial No. 772 MPC Type 32, Serial No. 322 No.: 72-1014, Amendment No. 5 HI-STORM I00S, Version B July 25, 2015 This letter contains no new or revised regulatory commitments.
Should you have any questions, please contact Mr. Michael K. Scarpello, Regulatory Affairs Manager, at (269) 466-2649.Sincerely, Joel P. Gebbie Site Vice President KMH/ams c: A.W. Dietrich, NRC Washington, DC R. A. Edwards, Ill, NRC Region III C. Haney, Director Office of Nuclear Material Safety and Safeguards J. T. King, MPSC P. L. Louden, Director Division of Nuclear Materials Safety, NRC Region Ill MDEQ -RMD/RPS NRC Resident Inspector R. J. Orlikowski, Chief Materials Control, ISESI, and Decommissioning Branch, NRC Region A. J. Williamson, Ft. Wayne AEP