ATTACHMENT 1 TO HOLTEC LETTER 5014923 1 of 186 Certificate of Compliance Renewal Application for the HI-STORM 100 Dry Storage System Certificate of Compliance No. 1014, Docket Number 72-1014

ATTACHMENT 1 TO HOLTEC LETTER 5014923 2 of 186 Table of Contents Chapter 1 - General Information Chapter 2 - Scoping Evaluation Chapter 3 - Aging Management Review Chapter 4 - Aging Management Tollgates Appendices A - AMPs B - TLAAs C - Canister Inspections D - Changes to FSARs E - Changes to Technical Specifications

ATTACHMENT 1 TO HOLTEC LETTER 5014923 3 of 186 Glossary Aging Management Program (AMP) is a program for addressing aging effects that may include prevention, mitigation, condition monitoring, and performance monitoring.

ALARA is an acronym for As Low As Reasonably Achievable.

All Metamic Fuel Baskets or AMFBs refers to those baskets in which both the structural and neutron absorption functions are rendered by panels made from Metamic-HT. There is no separate neutron absorber or stainless steel in AMFBs.

Alloy X Fuel Baskets refers to those baskets that employ neutron absorber panels affixed to the Alloy X grid- plate in an irremovable configuration. Duplex steel is a type of Alloy X steel that may be used for the MPC shell but not for the fuel basket components.

Ancillary or Ancillary Equipment is the generic name of a device used to carry out Short -term Operations.

Boral is a generic term to denote an aluminum-boron carbide cermet manufactured in accordance with U.S. Patent No. 4027377. The individual material supplier may use another trade name to refer to the same product.

BoralTM means Boral manufactured by AAR Advanced Structures.

BWR is an acronym for boiling water reactor.

Cavity Enclosure Container (CEC) means a thick walled cylindrical steel weldment that defines the storage cavity for the MPCs CoC is an acronym for Certificate of Compliance.

Commercial Spent Fuel or CSF refers to nuclear fuel used to produce energy in a commercial nuclear power plant.

Confinement Boundary means the outline formed by the all-welded cylindrical enclosure of the Multi-Purpose Canister (MPC) shell, MPC baseplate, MPC lid, MPC port cover plates, and the MPC closure ring which provides redundant sealing.

Confinement System means the Multi-Purpose Canister (MPC) which encloses and confines the spent nuclear fuel during storage.

Critical Characteristic means a feature of a component or assembly that is necessary for the proper safety function of the component or assembly. Critical characteristics of a material are those attributes that have been identified, in the associated material specification, as necessary to render the materials intended function.

DCSS is an acronym for Dry Cask Storage System.

Damaged Fuel Assembly is a fuel assembly with known or suspected cladding defects, as determined by review of records, greater than pinhole leaks or hairline cracks, empty fuel rod HI-2188877 i

ATTACHMENT 1 TO HOLTEC LETTER 5014923 4 of 186 locations that are not replaced with dummy fuel rods, missing structural components such as grid spacers, whose structural integrity has been impaired such that geometric rearrangement of fuel or gross failure of the cladding is expected based on engineering evaluations, or those that cannot be handled by normal means. Fuel assemblies that cannot be handled by normal means due to fuel cladding damage are considered fuel debris.

Damaged Fuel Container (or Canister) or DFC means a specially designed enclosure for damaged fuel or fuel debris which permits flow of gaseous and liquid media to escape while minimizing dispersal of gross particulates.

Damaged Fuel Isolator (DFI) means specially designed endcaps for a basket cell to enclose damaged fuel that can be handled by normal means.

Design Life is the minimum duration for which the component is engineered to perform its intended function set forth in this FSAR, if operated and maintained in accordance with this FSAR.

Enclosure Vessel (or MPC Enclosure Vessel) means the pressure vessel defined by the cylindrical shell, baseplate, port cover plates, lid, closure ring, and associated welds that provides confinement for the contents within the MPC. The Enclosure Vessel (EV) and the fuel basket together constitute the multi-purpose canister.

Equivalent (or Equal) Material is a material with critical characteristics (see definition above) that meet or exceed those specified for the designated material.

FSAR is an acronym for Final Safety Analysis Report (10CFR72).

Fuel Basket means a honeycombed structural weldment with square openings which can accept a fuel assembly of the type for which it is designed.

Fuel Debris is ruptured fuel rods, severed rods, loose fuel pellets, containers or structures that are supporting these loose fuel assembly parts, or fuel assemblies with known or suspected defects which cannot be handled by normal means due to fuel cladding damage.

Fuel Spacer or Fuel Shim is a metallic part interposed in the space between the fuel and the MPC cavity at either the top or the bottom (or both) ends of the fuel to minimize the axial displacement of the SNF within the MPC due to longitudinal inertia forces.

High Burnup Fuel, or HBF is a commercial spent fuel assembly with an average burnup greater than 45,000 MWD/MTU.

HI-TRAC is an acronym for Holtec International Transfer Cask.

HI-TRAC transfer cask or HI-TRAC means the transfer cask used to house the MPC during MPC fuel loading, unloading, drying, sealing, and on-site transfer operations to a HI-STORM storage overpack or HI-STAR storage/transportation overpack. The HI-TRAC shields and protects the loaded MPC. The term HI-TRAC is used as a generic term to refer to all HI-TRAC transfer cask designs, unless the discussion requires distinguishing among the designs..

HI-2188877 ii

ATTACHMENT 1 TO HOLTEC LETTER 5014923 5 of 186 HI-STORM overpack or storage overpack means the cask that receives and contains the sealed multi-purpose canisters containing spent nuclear fuel for long term storage. It provides the gamma and neutron shielding, ventilation passages, missile protection, and protection against natural phenomena and accidents for the MPC. The term overpack as used in this application refers to all models of the HI-STORM 100 (including, for example, the HI-STORM 100S and HI-STORM 100S Version B and Version E).

HI-STORM 100 System consists of any loaded MPC model placed within any design variant of the HI-STORM overpack.

HoltiteTM is the trade name for all present and future neutron shielding materials formulated under Holtec Internationals R&D program dedicated to developing shielding materials for application in dry storage and transport systems. The Holtite development program is an ongoing experimentation effort to identify neutron shielding materials with enhanced shielding and temperature tolerance characteristics. Holtite-A and Holtite-B are candidate neutron shield materials qualified under the Holtite R&D program.

Important to Safety (ITS) means a function or condition required to store spent nuclear fuel safely; to prevent damage to spent nuclear fuel during handling and storage, and to provide reasonable assurance that spent nuclear fuel can be received, handled, packaged, stored, and retrieved without undue risk to the health and safety of the public. ITS is further divided into categories A, B, and C in accordance with NUREG/CR-6407.

Independent Spent Fuel Storage Installation (ISFSI) means a facility designed, constructed, and licensed for the interim storage of spent nuclear fuel and other radioactive materials associated with spent fuel storage in accordance with 10CFR72.

Intact Fuel Assembly is defined as a fuel assembly without known or suspected cladding defects greater than pinhole leaks and hairline cracks, and which can be handled by normal means. Fuel assemblies without fuel rods in fuel rod locations shall not be classified as Intact Fuel Assemblies unless dummy fuel rods are used to displace an amount of water greater than or equal to that displaced by the fuel rod(s).

License Life means the duration for which the system is authorized by virtue of its certification by the U.S. NRC.

METAMIC is a trade name for an aluminum/boron carbide composite neutron absorber material qualified for use in the MPCs and in wet storage applications.

METAMIC-HT is a trade name for the metal matrix composite made by imbedding nano-particles of aluminum oxide and fine boron carbide powder on the grain boundaries of aluminum resulting in improve structural strength properties at elevated temperatures.

METCONTM is a trade name for the HI-STORM overpack structure. The trademark is derived from the metal-concrete composition of the HI-STORM overpack.

Moderate Burnup Fuel, or MBF is a commercial spent fuel assembly with an average burnup less than or equal to 45,000 MWD/MTU.

HI-2188877 iii

ATTACHMENT 1 TO HOLTEC LETTER 5014923 6 of 186 Multi-Purpose Canister (MPC) means the sealed canister consisting of a honeycombed fuel basket for spent nuclear fuel storage, contained in a cylindrical canister shell (the MPC Enclosure Vessel). There are different MPCs with different fuel basket geometries for storing PWR or BWR fuel, but all MPCs have identical exterior diameters. The MPC is the confinement boundary for storage conditions.

Neutron Absorber Material is a generic term to indicate any neutron absorber material qualified for use in the HI-STORM 100 System.

Neutron Shielding means a material used to thermalize and capture neutrons emanating from the radioactive spent nuclear fuel.

Non-Fuel Hardware (NFH) is defined as Burnable Poison Rod Assemblies (BPRAs), Thimble Plug Devices (TPDs), Control Rod Assemblies (CRAs), Axial Power Shaping Rods (APSRs), Wet Annular Burnable Absorbers (WABAs), Rod Cluster Control Assemblies (RCCAs), Control Element Assemblies (CEAs), Neutron Source Assemblies (NSAs), water displacement guide tube plugs, orifice rod assemblies, instrument tube tie-rods (ITTRs), vibration suppressor inserts, and components of these devices such as individual rods.

Plain Concrete is concrete that is unreinforced.

PWR is an acronym for pressurized water reactor SAR is an acronym for Safety Analysis Report.

SER is an acronym for Safety Evaluation Report, issued by the NRC.

Service Life means the duration for which the component is reasonably expected to perform its intended function, if operated and maintained in accordance with the provisions of this FSAR.

Service Life may be much longer than the Design Life because of the conservatism inherent in the codes, standards, and procedures used to design, fabricate, operate, and maintain the component.

SNF is an acronym for spent nuclear fuel.

SSC is an acronym for Structures, Systems and Components.

Stainless Steel Fuel Baskets or SSFBs refer to fuel baskets that employ stainless steel for structural function, and neutron absorption capability is provided by a discrete panel of Metamic or an equivalent neutron absorber. MPC-68 contains an SSFB.( See also Alloy X Fuel Basket )

Time-Limited Aging Analysis (TLAA) is a licensee or CoC holder calculation or analysis that has all of the following attributes: involves SSCs important to safety within the scope of license or CoC renewal; considers the effects of aging; involves time-limited assumptions defined by the current operating term; was determined to be relevant by the licensee or CoC holder in making a safety determination; involves conclusions or provides the basis for conclusions related to the capability of the SSCs to perform their intended safety functions; and is contained or incorporated by reference in the design bases HI-2188877 iv

ATTACHMENT 1 TO HOLTEC LETTER 5014923 7 of 186 Undamaged Fuel Assembly is: a) a fuel assembly without known or suspected cladding defects greater than pinhole leaks or hairline cracks and which can be handled by normal means; or b) a BWR fuel assembly with an intact channel, a maximum planar average initial of 3.3 wt% U-235, without known or suspected grossly breached spent fuel rods, and which can be handled by normal means. An undamaged fuel assembly may be a repaired/reconstituted fuel assembly.

VVM is an acronym for Vertical Ventilated Module ZR means any zirconium-based fuel cladding material authorized for use in a commercial nuclear power plant reactor. Any reference to Zircaloy fuel cladding in this FSAR applies to any zirconium-based fuel cladding material.

HI-2188877 v

ATTACHMENT 1 TO HOLTEC LETTER 5014923 8 of 186 CHAPTER 1: GENERAL INFORMATION 1.0 Introduction The HI-STORM 100 System Certificate of Compliance (CoC) No. 72-1014 was first approved for storage of spent nuclear fuel by the NRC on May 31, 2000, under the provisions of 10CFR 72 for use by general licensees. In accordance with 10 CFR 72.240(a) and as the certificate holder of CoC 1014, Holtec International is applying for a renewal of CoC 1014 for an additional term of 40 years.

This renewal application includes the Safety Analysis Report (SAR) information required by 10 CFR 72.240(c). The content of this application is based on the guidance provided in NUREG-1927 [2.1.1]. Additional guidance on content and format of this application is also provided in NEI-14-03 [1.1.3].

In accordance with the guidance in NUREG-1927, this renewal application is based on the continuation of the existing licensing basis throughout the period of extended operation and is based on maintaining the intended safety function of the structures, systems, and components (SSCs) important to safety. The existing licensing basis for the HI-STORM 100 Certificate of Compliance, consists primarily of:

a. CoC 1014 including appendices for each approved amendment
b. Safety Evaluation Reports (SERs) issued for each approved amendment
c. The Final Safety Analysis Reports corresponding to each approved amendment
d. Any other Docketed Licensing Correspondence, as applicable HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 1-1

ATTACHMENT 1 TO HOLTEC LETTER 5014923 9 of 186 1.1 HI-STORM 100 System Description This section provides a brief description of the HI-STORM 100 storage system. Full details of the system are contained in the FSAR referenced herein.

1.1.1 General System Description The HI-STORM 100 system is a canister based system for the storage of spent nuclear fuel (SNF) comprised of three discrete components: the multi-purpose canister (MPC), the storage overpack (HI-STORM), and the transfer cask (HI-TRAC). Its design features are intended to simplify and reduce on-site SNF loading, handling, and monitoring operations, and to provide for radiological protection, criticality control, and maintenance of structural and thermal safety margins.

1.1.2 Principle Components of the HI-STORM 100 System 1.1.2.1 Multi-Purpose Canister (MPC)

The MPC is a multi-purpose SNF storage device both with respect to the type of fuel assemblies and its versatility of use. The MPC is engineered as a cylindrical prismatic structure with square cross section storage cavities (fuel basket). The number of storage locations depends on the type of fuel. Regardless of the storage cell count, the construction of the MPC is fundamentally the same; it is built as a honeycomb of cellular elements positioned within a circumscribing cylindrical canister shell. The manner of cell-to-cell weld-up and cell-to-canister shell interface employed in the MPC imparts extremely high structural stiffness to the assemblage, which is an important attribute for mechanical accident events. The MPC provides the confinement boundary for the stored fuel. The confinement boundary is a seal-welded enclosure constructed entirely of stainless steel.

The HI-STORM 100 System is designed to accommodate a wide variety of spent nuclear fuel assemblies in a single basic overpack design by utilizing different MPCs. The external diameters of all MPCs are identical to allow the use of a single overpack. Each of the MPCs has different internals (baskets) to accommodate distinct fuel characteristics. Each MPC is identified by the maximum quantity of fuel assemblies it is capable of receiving. The MPC-24, MPC-24E, and MPC-24EF contain a maximum of 24 PWR fuel assemblies; the MPC-32 and MPC-32F contain a maximum of 32 PWR fuel assemblies; and the MPC-68, MPC-68M, MPC-68F, and MPC-68FF contain a maximum of 68 BWR fuel assemblies.

The PWR MPC-24, MPC-24E and MPC-24EF differ in construction from the MPC-32 (including the MPC-32F) and the MPC-68 (including the MPC-68M, MPC-68F and MPC-68FF) in one important aspect: the fuel storage cells in the MPC-24 series are physically separated from one another by a "flux trap", for criticality control. The PWR MPC-32 and -32F are designed similar to the MPC-68 (without flux traps) and their design includes credit for soluble boron in the MPC HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 1-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 10 of 186 water during wet fuel loading and unloading operations for criticality control. The MPC-68M is similar to the MPC-68 but utilizes the Metamic-HT material for both structural basket and criticality control. Similarly the MPC-32M, follows the MPC-32 design without flux traps, but utilizes Metamic-HT. The Version 1 variants of MPC-32 and -68 are identical in materials and environments, but simply have a thicker baseplate and are therefore not further differentiated in this application.

The MPC fuel basket is positioned and supported within the MPC shell by a set of basket supports welded to the inside of the MPC shell. In addition, the MPC fuel basket may also be positioned and supported within the MPC shell by a set of basket shims welded directly to the MPC fuel basket.

Lifting lugs attached to the inside surface of the MPC canister shell serve to permit lifting and placement of the empty MPC into the overpack. The lifting lugs also serve to axially locate the lid prior to welding. These internal lifting lugs are not used to handle a loaded MPC. Since the MPC lid is installed prior to any handling of the loaded MPC, there is no access to the lifting lugs once the MPC is loaded.

The top end of the MPC incorporates a redundant closure system. The MPC lid is a circular plate edge-welded to the MPC outer shell. This lid is equipped with vent and drain ports which are utilized to remove moisture and air from the MPC, and backfill the MPC with a specified pressure of inert gas (helium). The vent and drain ports are covered and welded before the closure ring is installed. The closure ring is a circular ring edge-welded to the MPC shell and lid. The MPC lid provides sufficient rigidity to allow the entire MPC loaded with SNF to be lifted by threaded holes in the MPC lid.

For fuel assemblies that are shorter than the design basis length, upper and lower fuel spacers (as appropriate) maintain the axial position of the fuel assembly within the MPC basket. The upper and lower fuel spacers are designed to withstand normal, off-normal, and accident conditions of storage.

The MPC confinement boundary is constructed entirely from stainless steel alloy materials. The confinement boundary lid to shell weld is covered with a redundant closure and is not exposed.

All MPC components that may come into contact with spent fuel pool water or the ambient environment (with the exception of neutron absorber, aluminum seals on vent and drain port caps, and optional aluminum heat conduction elements) must be constructed from stainless steel alloy materials. Concerns regarding interaction of coated carbon steel materials and various MPC operating environments [1.1.1] are not applicable to the MPC. All structural components in a MPC shall be made of Alloy X, a full description of Alloy X is contained in the HI-STORM 100 FSAR

[1.1.2].

1.1.2.2 HI-STORM 100 Overpack HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 1-3

ATTACHMENT 1 TO HOLTEC LETTER 5014923 11 of 186 The HI-STORM 100 overpacks are rugged, heavy-walled cylindrical vessels. There are a variety of overpack design variants including the HI-STORM 100S and HI-STORM 100A. The HI-STORM 100A overpack design is an anchored variant, and is identified by name only when the discussion specifically applies to the anchored overpack. The main structural function of the storage overpack is provided by carbon steel, and the main shielding function is provided by plain concrete. The overpack plain concrete is enclosed by cylindrical steel shells, a thick steel baseplate, and a top plate. The overpack lid has appropriate concrete shielding to provide neutron and gamma attenuation in the vertical direction.

The storage overpack provides an internal cylindrical cavity of sufficient height and diameter for housing an MPC. The storage system has air ducts to allow for passive natural convection cooling of the contained MPC. The location of the air outlets in the HI-STORM 100 and the HI-STORM 100S (including Version B and Version E) design differ. The air outlet ducts in the HI-STORM 100S and -100S Version B are integral to the lid assembly and are not in vertical alignment with the inlet ducts. In the Version E, the inlet vents have penetrations in different heights in the overpack inner and outer shells. In all designs, the air inlets and outlets are covered by a screen to reduce the potential for blockage. Routine inspection of the screens (or, alternatively, temperature monitoring) ensures that blockage of the screens themselves will be detected and removed in a timely manner.

The air inlets and outlets are penetrations through the thick concrete shielding provided by the HI-STORM 100 overpack. Within the air inlets and outlets, an array of gamma shield cross plates are installed, which are designed to scatter any radiation traveling through the ducts. The result of scattering the radiation in the ducts is a significant decrease in local dose rates around the air inlets and outlets.

Four treaded anchor blocks at the top of the overpack are provided for lifting. The anchor blocks are integrally welded to the radial plates, which are in turn full-length welded to the overpack inner shell, outer shell, and baseplate or inlet air duct horizontal plates.

The plain concrete between the overpack inner and outer shells is specified to provide the necessary shielding properties and compressive strength. The principal function of the concrete is to provide shielding against gamma and neutron radiation.

1.1.2.3 HI-TRAC Like the storage overpack, the HI-TRAC transfer cask is a rugged, heavy-walled cylindrical vessel.

The main structural function of the transfer cask is provided by carbon steel, and the main neutron and gamma shielding functions are provided by water and lead, respectively. The transfer cask is a steel, lead, steel layered cylinder with a water jacket attached to the exterior. The HI-TRAC design variants used with the HI-STORM 100 system include the HI-TRAC-100, -125, -100D, -

125D, and HI-TRAC MS All HI-TRACs are principally made of carbon steel and lead.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 1-4

ATTACHMENT 1 TO HOLTEC LETTER 5014923 12 of 186 The transfer cask provides an internal cylindrical cavity of sufficient size for housing an MPC.

The MPC access hole through the HI-TRAC top lid is provided to allow the lowering/raising of the MPC between the HI-TRAC transfer cask and the storage or transport overpack.

In the standard design, trunnions are provided for lifting and rotating the transfer cask body between vertical and horizontal positions. The lifting trunnions are located just below the top flange and the pocket trunnions are located above the bottom flange. The two lifting trunnions are provided to lift and vertically handle the HI-TRAC, and the pocket trunnions (in the HI-TRAC 100/125 only) provide a pivot point for the rotation of the HI-TRAC for downending or upending.

With the HI-TRAC-100D, 125D, and HI-TRAC MS designs, a mating device ancillary, which is not part of the HI-STORM CoC may be utilized during transfer.

1.1.2.4 Other Structures, Systems, and Components Fuel Assemblies The HI-STORM 100 system is designed to store spent fuel assemblies as described in Chapter 2 of the HI-STORM 100 FSAR [1.1.2], and authorized in Appendix B of the CoC.

Fuel Transfer and Auxiliary Equipment Auxiliary equipment used for loading of MPCs and cask movement (e.g., drying system, cask transporter, welding equipment, etc.) are not included as part of the HI-STORM 100 CoC, and as such are not described in detail in the FSAR, nor are they within scope for aging management.

ISFSI Pad The pad is a reinforced concrete structure where the HI-STORM 100 casks are stored. The ISFSI Pad is not a licensed component, of the HI-STORM 100 System. The CoC explicitly lists three components of the HI-STORM 100 Cask System (MPC, overpack, and transfer cask), and does not include the ISFSI pad. The CoC requirement is that the cask storage pad be verified by analysis to limit cask deceleration during both the design basis drop and non-mechanistic tipover event to 45 gs at the top of the MPC fuel basket. The CoC also requires that the ISFSI pad meet an equation based on coefficient of friction values. These analyses shall be performed using methodologies consistent with those described in the HI-STORM 100 FSAR. Previous amendments of the CoC required specific pad properties in the CoC to be met by the users to ensure that the cask deceleration was within limits.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 1-5

ATTACHMENT 1 TO HOLTEC LETTER 5014923 13 of 186

1.2 Background

The HI-STORM 100 System was originally approved by the NRC on May 31, 2000.

Subsequently amendments 1 through 14 were approved by the NRC, with a 15th amendment under NRC review at time of the initial renewal application. These amendments were requested by Holtec International to address continuing needs of utilities to store different types of PWR or BWR fuel, with revised heat loads, enrichments, or other parameters. The HI-STORM 100 MPCs are also approved for transportation under 10 CFR Part 71, but that CoC is not part of this storage renewal application. Based on timing of this renewal application, Holtec has chosen to include the information from the amendments 15 in progress, as they are likely to be issued while the renewal is under review.

Table 1.2-1 lists each of the approved HI-STORM 100 storage amendments. The table provides a description of the scope of the amendment, its approval time, identification of the FSAR which provides the licensing basis, and a pointer to where the AMPs for different amendments are located in this application. Note, that because the FSAR is updated for each amendment, the latest FSAR contains the full licensing basis for all previous amendments.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 1-6

ATTACHMENT 1 TO HOLTEC LETTER 5014923 14 of 186 Table 1.2-1: HI-STORM 100 CoC Amendments Amendment Approval Description of Changes FSAR Basis Location of AMPs Number Date HI-2002444, 0 5/31/2000 Appendix A Initial Issue Rev 0

  • Add new MPCs: MPC-24E, MPC-24EF, MPC-32 for PWR fuel and MPC-68FF for BWR fuel
  • Add damaged fuel containers
  • Add HI-STORM 100S and 100A/SA anchored overpacks
  • Allow storage of high burnup fuel HI-2002444, 1 7/15/2002 Appendix A
  • Revise thermal analysis Rev 1 or 2
  • Revise helium backfill requirements
  • Allow FHD system
  • Allow storage of selected non-fuel hardware
  • Move special requirement for first system in places to CoC
  • Add use of Metamic as an alternate neutron absorber material
  • Allow storage of damaged fuel in MPC-32 and MPC-32F
  • Include appropriate values for soluble boron for MPC-32 and Appendix A MPC-32F
  • Clarify that heat conduction elements are no longer used
  • Revise CoC to reflect changes in MPC cavity drying HI-2002444, 6/7/2005
  • Revise the TS to remove the helium leakage test requirement Rev 3 or 4 2
  • Relocate the helium backfilling requirements to new table in the TS
  • Revise requirements for ensuring MPC cavity bulk helium temperature
  • Add new TS Program for radiation protection
  • Add other components to non-fuel hardware HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev.

10 1-7

ATTACHMENT 1 TO HOLTEC LETTER 5014923 15 of 186 Amendment Approval Description of Changes FSAR Basis Location of AMPs Number Date

  • Increase initial enrichment for PWR damaged fuel/fuel debris to 5.0 wt%
  • Revise burn-up as a function of cooling time and fuel array/class
  • Modify completion times for blocked duct LCO
  • Add new limits for burnup as a function of decay heat, enrichment, cooling time, fuel class
  • Revise maximum allowable uranium masses
  • Revise maximum allowable burn-up for non-fuel hardware
  • Update ASME Code alternatives
  • Revise App B in accordance with ISG-11 Rev 3
  • Increase off-normal design pressure and temperature limit for overpack lid
  • Move FSAR appendices 3.B through 3.AS to calculation package 2

(continued)

  • Remove three-ducts blocked condition
  • Revise discussion of QA program
  • Editorial corrections in CoC
  • Modify CoC condition 11
  • Modify drying acceptance criterion for FHD
  • Include maximum boron carbide content in Metamic
  • Add language incorporating FSAR Section 9.1.5.3 by reference
  • Clarify the equation for free-standing casks
  • Modification of design temperatures of MPC shell, overpack concrete, and Holtite
  • Modify Code applicability for MPC basket and basket angle supports
  • Add FHD failure and SCS power failure as off-normal events and SCS failure as accident event HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev.

10 1-8

ATTACHMENT 1 TO HOLTEC LETTER 5014923 16 of 186 Amendment Approval Description of Changes FSAR Basis Location of AMPs Number Date

  • Add new requirement to address degraded cask/pad interface friction
  • Minor editorial changes to CoC
  • Modify the TS to eliminate the requirement to perform helium leak rate testing on vent and drain port cover plates if the associated welds are performed with at least a two weld pass and liquid penetrant examinations of the root and final weld passes
  • Modify the TS to eliminate cooling of the MPC cavity prior to reflood during unloading. The requirement is now on MPC cavity pressure.
  • Modify the TS to allow linear interpolation between minimum HI-2002444, 3 soluble boron concentrations of 4.1 wt% and 5.0 wt% enrichment 5/29/2007 Appendix A Rev 5 in the MPC-32/32F
  • Modify the definition of fuel debris to permit containers/structures that provide support to loose fuel assembly parts and non-fuel hardware to be stored as fuel debris in DFCs
  • Modify the definition of non-fuel hardware to include neutron source assemblies
  • Modify the TS to permit storage of PWR fuel assemblies with annular fuel pellets in the top and bottom 12 in of active fuel length
  • Modify the definition of damaged fuel
  • Indian Point Unit 1 options added to CoC:

o Shortening of the HI-STORM 100S Ver B, MPC-32,-32F, and HI-TRAC 100D HI-2002444, 4 1/8/2008 Appendix A o TS Definition of Transport Operations Rev 6 o Soluble boron requirements for 14x14E IP1 fuel o Helium gas backfill requirements for 14x14E IP1 fuel o Addition of another DFC design HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev.

10 1-9

ATTACHMENT 1 TO HOLTEC LETTER 5014923 17 of 186 Amendment Approval Description of Changes FSAR Basis Location of AMPs Number Date o Addition of separate burnup cooling time, and decay heat limits for 14x14E IP1 fuel o Addition of antimony-beryllium secondary sources as approved contents o Loading of all IP1 fuel assemblies in DFCs o Preclusion of loading of IP1 fuel debris in MPC-32 or -32F o The reduction of maximum enrichment for 14x14E IP1 fuel from 5.0 to 4.5 wt%

o Changes to licensing drawings to differentiate the IP1 MPC-32 and -32F

  • Replace all UST&D references with HMD
  • Deletion of the requirement to perform thermal validation tests
  • An increase in the design basis maximum decay heat loads and addition of regionalized loading scheme
  • Increase in the maximum BWR fuel assembly weight from 700 to 730 lb
  • Changes to PWR 16x16 fuel assembly
  • Change in storage location for fuel with APSRs in the MPC-32 and in the MPC-24, -24E, and -32 for fuel with CRAs, RCCAs, HI-2002444, 5 and CEAs 7/14/2008 Appendix A Rev 7
  • Elimination of restriction that fuel debris can only be loaded into the MPC-24EF,-32F, -68F, and -68FF
  • Requirement that MPC confinement boundary components and MPC components exposed to spent fuel pool water or ambient environment be made of stainless steel, or for MPC internals, neutron absorber or aluminum
  • Addition of a threshold heat load below which SCS is not required
  • Editorial changes HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev.

10 1-10

ATTACHMENT 1 TO HOLTEC LETTER 5014923 18 of 186 Amendment Approval Description of Changes FSAR Basis Location of AMPs Number Date

  • Modification of the definition of non-fuel hardware 6
  • Modify TS for editorial changes 8/17/2009 HI-2002444, Appendix A
  • Modify TS to allow ITTRs in MPC-24 and -32 Rev 8
  • Addition of HI-STORM 100U System, with separate CoC HI-2002444, appendices Rev 9 or 10 7
  • Upgrade all thermal simulations to utilize a 3D model 12/28/2009 Appendix A
  • Reinstating decay heat limits for damaged fuel and fuel debris from Amd 3 that had been inadvertently deleted from Amds 5 and 6
  • Addition of new MPC-68M with two new BWR fuel array classes HI-2002444,
  • Addition of new PWR fuel array class Rev 11
  • Revised Condition 3 to perform helium leak test on base material
  • Editorial changes 5/2/2012 Rev 1:

Rev 1 Changes HI-2002444, 8, 8R1 Rev 11.1 Appendix A

  • Change to burnup/cooling time limits for TPDs Rev 1:
  • Changes to Metamic-HT testing requirements 2/16/2016
  • Changes to Metamic-HT MGVs
  • Update fuel definitions to allow BWR fuel affected by certain corrosion mechanisms within specific guidelines to be classified as undamaged fuel
  • Broadening the subgrade requirements for the HI-STORM HI-2002444, 100U part of the HI-STORM 100 Cask System 3/11/2014 Rev 12
  • Update the HI-TRAC thermal methodology from 2-D to 3-D 9, 9R1 Rev 1 Changes Rev 1: Appendix A Rev 1:
  • Change to burnup/cooling time limits for TPDs 3/21/2016 HI-2002444,
  • Changes to Metamic-HT testing requirements Rev 13
  • Changes to Metamic-HT MGVs HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev.

10 1-11

ATTACHMENT 1 TO HOLTEC LETTER 5014923 19 of 186 Amendment Approval Description of Changes FSAR Basis Location of AMPs Number Date

  • Update fuel definitions to allow BWR fuel affected by certain corrosion mechanisms within specific guidelines to be classified as undamaged fuel
  • Addition of new 16x16B and C fuel classes HI-2002444, 10
  • Addition of ASME Code Alternative for SA-516/516A 5/31/2016 Rev 14 or 15 Appendix A material
  • Revision to Condition 9
  • Increase the per-storage location weight limit for cells authorized for damaged fuel container (DFC) in MPC-68 series
  • Change surveillance requirements for cask with certain heat load in the Technical Specifications
  • Allow the storage of higher average initial enrichment wt.%

U-235 fuel with low enriched CRUD-induced localized corrosion (CILC) fuel

  • Increase the enrichment limit for the 10x10G BWR fuel 11 2/25/2019 HI-2002444 Appendix A assembly from 4.6 wt% U-235 to 4.75 wt% U-235 Rev 16
  • Change the minimum soluble boron concentration limits for the 17x17A PWR fuel assemblies in MPC-32
  • Increase the burnup limit to accommodate NFH, including neutron source assembly in combination with other control components
  • Add thoria rods/canister as contents for the MPC-68M
  • Add a second permissible composition for thoria rods for all MPC-68 models
  • Editorial clarifications
  • Addition of a new regionalized quarter-symmetric heat load HI-2002444 12 2/24/2019 Rev 17 Appendix A (QSHL) pattern for MPC-68M and allow fuel that has been cooled for at least 2 years to be stored in the MPC-68M HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev.

10 1-12

ATTACHMENT 1 TO HOLTEC LETTER 5014923 20 of 186 Amendment Approval Description of Changes FSAR Basis Location of AMPs Number Date

  • Allow the storage of damaged fuel and fuel debris in DFC under the new regionalized QSHL pattern
  • Add a new duplex stainless steel as an allowed material for the MPC confinement boundary in the HI-STORM 100 system
  • Add cyclic vacuum drying for all MPCs
  • Update coefficients for burnup calculation equation for fuel assembly with cooling time of 2 through 40 years.
  • Update the initial uranium weight for the 16x16B and 16x16C HI-2002444 13 5/13/2019 Rev 18 Appendix A fuel assembly classes to match the value for 16x16A in HI-STORM 100 CoC Appendix B
  • Add three new regionalized QSHL loading patterns for the To be issued MPC-68M TBD after
  • Reduce cooling time to 1 year for all fuel types for storage in amendment 14 the MPC-68M (Submitted becomes Appendix A
  • Used damaged fuel isolator (DFI) for damaged fuel stored in Oct 31, effective the MPC-68M 2018)
  • Modify the description of the vents in the overpack in the COC
  • New version of transfer cask called HI-TRAC MS To be issued
  • Inclusion of MPC-32M as new canister after
  • Inclusion of MPC-32 and MPC-68 Version 1 canisters TBD amendment
  • Addition of HI-STORM 100 Version E overpack becomes 15
  • Inclusion of three new BWR fuel types (Submitted effective Appendix A
  • Addition of HI-DRIP and Dry Ice Jacket ancillary system March 20,
  • Allowance for partial gadolinium credit for BWR fuel 2019) assemblies
  • Removal of dose rate from accident analysis of non-mechanistic tip-over HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev.

10 1-13

ATTACHMENT 1 TO HOLTEC LETTER 5014923 21 of 186 Amendment Approval Description of Changes FSAR Basis Location of AMPs Number Date

  • Allowance for canisters previously loaded under other helium leak test requirements to be upgraded
  • Editorial drawing changes HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev.

10 1-14

ATTACHMENT 1 TO HOLTEC LETTER 5014923 22 of 186 1.3 References

[1.1.1] U.S. NRC Information Notice 96-34, Hydrogen Gas Ignition During Closure Welding of a VSC-24 Multi-Assembly Sealed Basket.

[1.1.2] HI-STORM 100 Final Safety Analysis Report, Revision 18, Holtec International, May 16, 2019

[1.1.3] NEI 14-03, Format, Content and Implementation Guidance for Dry Cask Storage Operations-Based Aging Management, Rev 1, September 2015 HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 1-15

ATTACHMENT 1 TO HOLTEC LETTER 5014923 23 of 186 CHAPTER 2: SCOPING EVALUATION 2.0 Introduction Chapter 2 describes the evaluation process and methodology used to identify the structures, systems, and components (SSCs) of the HI-STORM 100 System and the subcomponents thereof that are within the scope of the license renewal.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-1

ATTACHMENT 1 TO HOLTEC LETTER 5014923 24 of 186 2.1 Scoping Evaluation Process and Methodology The scoping evaluation of the HI-STORM 100 System is performed based on the two-step process described in NUREG-1927 [2.1.1]. The first step in the process is a screening evaluation to determine which systems, structures, and component (SSC) are within the scope of the license renewal. Per NUREG-1927, Section 2.4.2, structures, systems, and components (SSC) are considered to be within the scope of the renewal if they satisfy either of the following criteria:

1) They are classified as Important-To-Safety (ITS), as they are relied on to do one of the following functions:
i. Maintain the conditions required by the regulation or specific license to store spent fuel safely; ii. Prevent damage to the spent fuel during handling and storage; or iii. Provide reasonable assurance that spent fuel can be received, handled, packaged, stored, and retrieved without undue risk to the health and safety of the public.

These SSCs ensure that important safety functions are met for:

1) Confinement
2) Radiation Shielding
3) Sub-Criticality Control
4) Heat-Removal Capability
5) Structural Integrity,
6) Retrievability
2) They are classified as Not-Important-To-Safety (NITS), but, according to the design bases, their failure could prevent fulfillment of a function that is ITS.

Any SSC that meets either Scoping Criterion 1 or 2 above is considered within the scope of license renewal (in-scope), and the function(s) it is required to perform during the extended term is identified. The results of the scoping evaluation are presented in Section 2.2.

As stated above, the HI-STORM 100 renewal is based on the continuation of the existing Current Licensing Basis (CLB) throughout the period of extended operation and maintenance of the intended safety functions of the SSC ITS. Accordingly, the sources of information reviewed in the scoping evaluation that describe the CLB and the intended safety functions of the SSC ITS are the HI-STORM 100 FSAR [1.1.2], Certificate of Compliance, and Safety Evaluation Report. Note that the reference information for these documents are contained in Section 2.3, as more than one revision of each may be utilized throughout the document.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 25 of 186 2.2 Results of Scoping Evaluation As discussed in Section 1.2, the HI-STORM 100 system includes the following major components:

  • HI-STORM 100 Overpack
  • Fuel Assembly
  • HI-TRAC Transfer Cask
  • Fuel Transfer and Auxiliary Equipment The following sections include brief descriptions of the components, detailed descriptions can be found in Reference [2.1.2] through [2.1.21]. Table 2.2-1 summarizes the results of the scoping evaluation, listing the SSC that are identified as within scope and the criteria upon which they are determined to be within scope. Classifications are listed for the overall component, but some subcomponents are NITS. The categorizations are consistent with Reference [2.1.40].

2.2.1 Description of SSC 2.2.1.1 MPC The MPC (including fuel basket) is constructed primarily of stainless steel, with supplemented Metamic or BoralTM neutron absorbers. The functions of the MPC (including fuel basket) are confinement, structural integrity, criticality control, heat transfer, shielding, and retrievability. The MPC is classified as ITS-A, with individual subcomponents shown in Table 2.2-2.

2.2.1.2 HI-STORM 100 Overpack The HI-STORM 100 overpacks are rugged, heavy-walled cylindrical vessels. The overpack consists primarily of concrete enclosed by cylindrical steel shells, and a closure lid. The storage system has air ducts to allow for passive natural convection cooling of the contained MPC. The functions of the HI-STORM Overpack are structural integrity, heat transfer, and shielding. The overpack is classified as ITS-B, with individual subcomponents shown in Table 2.2-3.

2.2.1.3 HI-TRAC Transfer Cask Like the storage overpack, the HI-TRAC transfer cask is a rugged, heavy-walled cylindrical vessel. The main structural function of the transfer cask is provided by carbon steel, and the main neutron and gamma shielding functions are provided by water and lead, respectively. The transfer cask is a steel, lead, steel layered cylinder with a water jacket attached to the exterior. The functions of the HI-TRAC are structural integrity, heat transfer, and shielding. The HI-TRAC is classified as ITS-A, with individual subcomponents shown in Table 2.2-4.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-3

ATTACHMENT 1 TO HOLTEC LETTER 5014923 26 of 186 2.2.1.4 Fuel Assembly The HI-STORM 100 system is designed to store spent fuel assemblies as described in Chapter 2 of the HI-STORM 100 FSAR. Parts of the fuel assembly are credited for criticality control, confinement, and structural integrity. The fuel assemblies are classified as ITS-A, with individual subcomponents shown in Table 2.2-5.

2.2.1.5 ISFSI Pad The ISFSI Pad is a facility within the perimeter fence, designed for the storage of loaded HI-STORM 100 overpacks. Though not described in detail in the FSAR, basic requirements for the storage pad are defined to ensure there is no operational impact to the overpacks or spent fuel contained within. The ISFSI Pad is not defined as important to safety in the FSAR and its failure does not prevent any ITS function from being fulfilled, since impacts to the overpack from non-mechanistic tipover on the pad are evaluated in the FSAR and determined to be acceptable. Therefore, the Pad is not considered in scope. Note that this refers to the ISFSI pad for the above ground systems, for the HI-STORM 100U, the pad is part of the overall system, and is considered in-scope.

2.2.1.6 ISFSI Security Equipment (Physical Protection)

The HI-STORM 100 ISFSI Security Equipment is not part of the HI-STORM 100 storage CoC, and as such, is not described in detail in the FSAR. The site will have programs and procedures to ensure that the ISFSI security equipment requirements are met, and potential failure of the ISFSI security equipment would not prevent the stored casks from performing their intended functions, and therefore the equipment is not considered in scope, in accordance with NUREG-1927.

2.2.1.7 Fuel Transfer and Auxiliary Equipment Auxiliary equipment used for loading of MPCs and cask movement (e.g., drying system, cask transporter (VCT), Cask Transfer Facility (CTF), welding equipment, lifting equipment, mating device, etc.) are not included as part of the HI-STORM 100 CoC, and as such are not described in detail in the FSAR, nor are they within scope for aging management, in accordance with NUREG-1927.

2.2.2 SSCs Within the Scope of CoC Renewal The SSCs determined to be within the scope of the license renewal are the MPC, Overpack, HI-TRAC, and Fuel Assembly as shown in Table 2.2-1. Note that the fuel assembly hardware and cladding which supports the retrievability of the spent fuel are considered in scope.

2.2.3 SSCs Not Within the Scope of CoC Renewal As shown in Table 2.2-1, the ISFSI Pad, ISFSI Security Equipment, and Fuel Transfer and Auxiliary Equipment do not meet the criteria for being within scope of the license renewal. Note that the fuel pellets within the assemblies are not considered in the original safety analysis, and are not relied upon to meet retrievability or confinement functions.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-4

ATTACHMENT 1 TO HOLTEC LETTER 5014923 27 of 186 Table 2.2 Summary of Scoping Evaluation Results (Applies to all HI-STORM 100 Amendments approved and under review)

Scoping Results Structure, System, or Component (SSC) In-Scope SSC Criterion 11 Criterion 22 MPC Yes N/A Yes HI-STORM 100 Overpack Yes N/A Yes HI-TRAC Transfer Cask Yes N/A Yes Fuel Assembly3 Yes N/A Yes ISFSI Pad No No No ISFSI Security Equipment No No No Fuel Transfer and Auxiliary Equipment No No No Notes:

1 SSC is Important-to-Safety (ITS) 2 SSC is Not Important-to-Safety (NITS), but its failure could prevent an ITS function from being fulfilled 3 Fuel pellets not included, per NUREG-1927.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-5

ATTACHMENT 1 TO HOLTEC LETTER 5014923 28 of 186 Table 2.2 Intended Safety Functions of MPC Subcomponents Subcomponent Intended FunctionNote MPC Model Safety Class Licensing 1,2 Drawing Number Shell Confinement, Structural 68,68F,68FF, ITS 3923, 11572 Integrity, Heat Transfer, 68M, 24,24 Ver A, Shielding 24E/EF, 32, 32M Baseplate Confinement, Structural 68,68F,68FF, ITS 3923, 11572 Integrity, Heat Transfer, 68M, 24,24 Ver A, Shielding 24E/EF, 32, 32M Lid Confinement, Structural 68,68F,68FF, ITS 3923, 11572 Integrity, Heat Transfer, 68M, 24,24 Ver A, Shielding, Retrievability 24E/EF, 32, 32M Closure Ring Confinement 68,68F,68FF, ITS 3923, 11572 68M, 24,24 Ver A, 24E/EF, 32, 32M Port Cover Plates Confinement 68,68F,68FF, ITS 3923, 11572 68M, 24,24 Ver A, 24E/EF, 32, 32M Basket Cell Spacer Structural Integrity, 24,24 Ver A, ITS 3925, 3926 Block Criticality Control 24E/EF Basket Center Structural Integrity, 24,24 Ver A, ITS 3925, 3926 Column Criticality Control 24E/EF Basket Cell Plates Structural Integrity, 68,68F,68FF,24,24 ITS 3925, 3926, 3927, Criticality Control Ver A, 24E/EF, 32 3928 Short Cell Spacer N/A 24,24 Ver A, NITS 3925, 3926 Plates 24E/EF Flux Gap Cover Criticality Control 24,24 Ver A, ITS 3925, 3926 24E/EF Flux Gap Plate Criticality Control 24,24 Ver A, ITS 3925, 3926 24E/EF Basket Cover Criticality Control 24,24 Ver A, ITS 3925, 3926 Angle 24E/EF Basket Cell Angle Criticality Control, 24,24 Ver A, ITS 3925, 3926 Structural Integrity 24E/EF Basket Cell Criticality Control, 24,24 Ver A, ITS 3925, 3926 Channel Structural Integrity 24E/EF Neutron Absorber Criticality Control 68,68F,68FF,24,24 ITS 3925, 3926, 3927, Ver A, 24E/EF, 32 3928 Drain and Vent Shielding 68,68F,68FF, ITS 3925, 3926, 3927, Shield Block 68M, 24,24 Ver A, 3928 24E/EF, 32, 32M Plugs for Drilled Shielding 68,68F,68FF, NITS 3923, 11572 Holes 68M, 24,24 Ver A, 24E/EF, 32, 32M HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-6

ATTACHMENT 1 TO HOLTEC LETTER 5014923 29 of 186 Subcomponent Intended FunctionNote MPC Model Safety Class Licensing 1,2 Drawing Number Lifting Hole Plug Structural Integrity 68,68F,68FF, ITS 3923, 11572 (Optional) 68M, 24,24 Ver A, 24E/EF, 32, 32M Heat Conduction Heat Transfer 68,68F,68FF,24,24 ITS 3925, 3926, 3927, Elements Ver A, 24E/EF 3928 (Optional)

Upper Fuel Spacer Structural Integrity 68,68F,68FF, ITS 3927, 3928 Column 68M, 32 Upper Fuel Spacer Structural Integrity 24,24 Ver A, ITS 3925, 3926 Pipe 24E/EF Sheathing Structural Integrity 68,68F,68FF,24,24 ITS 3925, 3926, 3927, Ver A, 24E/EF, 32 3928 Shims Structural Integrity, 68,68F,68FF,24,24 NITS 3925, 3926, 3927, Heat Transfer Ver A, 24E/EF, 3928, 11425 32, 32M Basket Supports Structural Integrity 68,68F,68FF ITS 3928 (Angled Plates and Parallel Plates with connecting end shims)

Basket Supports Structural Integrity 32 ITS 3927 (Angled Plates and Parallel Plates, if Basket Shims are not used)

Basket Supports Structural Integrity 68,68F,68FF,32 NITS 3927, 3928 (Flat Plates)

Basket Supports (if Structural Integrity 32 NITS 3927 Basket Shims are used)

Basket Shims Structural Integrity 32 ITS 3927 Lift Lug N/A - used only with 68,68F,68FF, ITS 3925, 3926, 3927, unloaded MPC 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Lift Lug Baseplate N/A - used only with 68,68F,68FF, ITS 3925, 3926, 3927, unloaded MPC 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Upper Fuel Spacer Structural Integrity 68,68F,68FF, NITS 3925, 3926, 3927, Bolt 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Upper Fuel Spacer Structural Integrity 68,68F,68FF, ITS 3925, 3926, 3927, End Plate 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-7

ATTACHMENT 1 TO HOLTEC LETTER 5014923 30 of 186 Subcomponent Intended FunctionNote MPC Model Safety Class Licensing 1,2 Drawing Number Lower Fuel Spacer Structural Integrity 68,68F,68FF, ITS 3925, 3926, 3927, Column 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Lower Fuel Spacer Structural Integrity 68,68F,68FF, ITS 3925, 3926, 3927, End Plate 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Vent Shield Block Structural Integrity 68,68F,68FF, ITS 3925, 3926, 3927, Spacer 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Vent and Drain RetrievabilityN/A 68,68F,68FF, ITS 3925, 3926, 3927, Tube 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Vent and Drain RetrievabilityN/A 68,68F,68FF, ITS 3925, 3926, 3927, Cap 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Vent and Drain N/A 68,68F,68FF, 68M ITS 3928, 7195 Sleeve Inserts Vent and Drain N/A 68,68F,68FF, NITSITS 3925, 3926, 3927, Cap Seal Washer 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Vent and Drain N/A 68,68F,68FF, NITS 3925, 3926, 3927, Cap Seal Washer 68M, 24,24 Ver A, 3928, 7195, 11425 Bolt 24E/EF, 32, 32M Vent and Drain N/A 68,68F,68FF, NITS 3925, 3926, 3927, Cap Lock Washer 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Reducer/Coupling N/A 68,68F,68FF, NITS 3925, 3926, 3927, 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Drain Line N/A 68,68F,68FF, NITS 3925, 3926, 3927, 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Damaged Fuel Criticality Control 68,68F,68FF, ITS 3925, 3926, 3927, Container 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Basket Sub-Panel Criticality Control 68M, 32M ITS 7195, 11425 Basket Shims Structural Integrity, 68M, 32M ITS 7195, 11425 Heat Transfer Solid Shims Structural Integrity, 68M, 32M ITS 7195, 11425 Heat Transfer Damaged Fuel Criticality Control 68,68F,68FF, ITS 3925, 3926, 3927, Isolator 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-8

ATTACHMENT 1 TO HOLTEC LETTER 5014923 31 of 186 Subcomponent Intended FunctionNote MPC Model Safety Class Licensing 1,2 Drawing Number Drain Line Guide Retrievability 68,68F,68FF, NITS 3925, 3926, 3927, Tube 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Vent and Drain Retrievability 68,68F,68FF, ITS 3925, 3926, 3927, Tube, Optional 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Threaded Disc, Retrievability 68,68F,68FF, ITS 3925, 3926, 3927, Plug Adjustment 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Vent and Drain Retrievability 68,68F,68FF, ITS 3925, 3926, 3927, Plug 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Thread Shield Cap Retrievability 68,68F,68FF, NITS 3925, 3926, 3927, 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M Retaining Ring Retrievability 68,68F,68FF, NITS 3925, 3926, 3927, 68M, 24,24 Ver A, 3928, 7195, 11425 24E/EF, 32, 32M (1) Intended Functions are based on Section 2.1, Criterion 1 - Criticality control, heat transfer, radiation shielding, confinement, structural integrity, and retrievability. These intended functions are for the renewal period.

(2) N/A means the component does not have a function in the period of extended operation and is NITS. These components are not included in the aging management review tables in Chapter 3.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-9

ATTACHMENT 1 TO HOLTEC LETTER 5014923 32 of 186 Table 2.2 Intended Safety Functions of HI-STORM Overpack Subcomponents Subcomponent Intended FunctionNote Overpack Safety Class Licensing 1,3 ModelNote 2 Drawing Number Radial Shield Shielding 100, 100S ITS 1495, 3669 Shield Block Ring Shielding 100, 100S ITS 1495, 3669

& Shell Pedestal Shield Shielding 100, 100S, 100S ITS 1495, 3669 Ver C Lid Shield Shielding 100, 100S ITS 1495, 3669 Shield Shell Shielding 100 ITS 1495 Shield Block Shielding 100, 100S, 100S ITS 1495, 3669, 4116 Ver B Gamma Shield Shielding 100, 100S, 100S ITS 1495, 3669, 4116 Cross Plates & Ver B, 100S Ver C Tabs Baseplate Structural Integrity, 100, 100S ITS 1495, 3669 Shielding Outer Shell Structural Integrity, 100, 100S, 100S ITS 1495, 3669, 4116, Shielding Ver B, 100S Ver E 11371 Inner Shell Structural Integrity, 100, 100S, 100S ITS 1495, 3669, 4116, Shielding Ver B, 100S Ver E 11371 Pedestal Shell Structural Integrity 100, 100S ITS 1495, 3669 Pedestal Baseplate Structural Integrity 100, 100S ITS 1495, 3669 Lid Bottom Plate Structural Integrity 100, 100S ITS 1495, 3669 Lid Shell Structural Integrity, 100 ITS 1495 Shielding Inlet Vent Vertical Structural Integrity, 100, 100S ITS 1495, 3669

& Horizontal Heat Transfer Plates Exit Vent Vertical Structural Integrity, 100, 100S ITS 1495, 3669

& Horizontal Heat Transfer Plates Top Plate Structural Integrity, 100, 100S, 100S ITS 1495, 3669, 4116 Shielding Ver B, 100S Ver C Lid Top Plate Structural Integrity, 100, 100S, 100S ITS 1495, 3669, 11371 Shielding Ver E Lid Shield Ring Structural Integrity 100S, 100S Ver B, ITS 3669 100S Ver C Lid Vent Side Structural Integrity 100S ITS 3669 Plate Lid Shield Block Structural Integrity, 100S ITS 3669 Shielding HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-10

ATTACHMENT 1 TO HOLTEC LETTER 5014923 33 of 186 Subcomponent Intended FunctionNote Overpack Safety Class Licensing 1,3 ModelNote 2 Drawing Number Radial Plate Structural Integrity 100, 100S, 100S ITS 1495, 3669, 4116, Ver B , 100S Ver 11371 C, 100S Ver E Lid Stud, Tee Structural Integrity 100, 100S ITS 1495, 3669 Handle Bolt & Nut Lid Stud Nut Structural Integrity 100, 100S ITS 1495, 3669 Bolt Anchor Block Structural Integrity 100, 100S, 100S ITS 1495, 3669, 4116 Ver B, 100S Ver C Channel or Guide Structural Integrity 100, 100S, 100S ITS 1495, 3669, 4116, Tube Ver B, 100S Ver E 11371 Pedestal Platform Structural Integrity 100, 100S, 100S ITS 1495, 3669 Ver C Shear Ring Structural Integrity 100S, 100S Ver B, ITS 1495, 3669, 4116 100S Ver C Storage Marking N/A 100, 100S, 100S NITS 1495, 3669, 4116 Nameplate Ver B, 100S Ver C Exit Vent Screen N/A 100 NITS 1495 Sheet Drain Pipe N/A 100 NITS 1495 Exit & Inlet Screen N/A 100 NITS 1495 Frame Stud Tube N/A 100S NITS 3669 Screens N/A 100, 100S, 100S NITS 1495, 3669, 4116 Ver B, 100S Ver C Screen Bolts N/A 100S NITS 3669 Compression N/A 100 NITS 1495 Fitting, Protection Head, Bushing, Coupling, and Hex Nipple for Thermocouple Conduit N/A 100 NITS 1495 Connection Screws for Screen N/A 100, 100S Ver B NITS 1495, 4116 Fit-Up 100 Lid Washer N/A 100, 100S NITS 1495, 3669 100S Lid Washer Structural Integrity 100S ITS 3669 Channel Mounts Structural Integrity 100, 100S ITS 1495, 3669 Pedestal Shims N/A 100 NITS 1495 Screen Bar N/A 100 NITS 1495 Vent Frames N/A 100, 100S, 100S NITS 1495, 3669 Ver C HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-11

ATTACHMENT 1 TO HOLTEC LETTER 5014923 34 of 186 Subcomponent Intended FunctionNote Overpack Safety Class Licensing 1,3 ModelNote 2 Drawing Number Strap Block N/A 100, 100S, 100S NITS 1495, 3669, 4116 (Grounding Lugs) Ver B, 100S Ver C Radial Weld Plate Structural Integrity 100, 100S ITS 1495, 3669 Heat Shield Heat Transfer 100 ITS 1495 Heat Shield Ring Heat Transfer 100 ITS 1495 Lug Support Ring Structural Integrity 100A, 100SA only ITS 1495, 3669, 3187 Gusset Structural Integrity 100A, 100SA only ITS 1495, 3669, 3187 Stud with Nut Structural Integrity 100A, 100SA only ITS 1495, 3669, 3187 Washer N/A 100A, 100SA only NITS 1495, 3669, 3187 Bottom Plate Structural Integrity 100S Ver B, 100S ITS 3669, 4116 Ver C 100S Version B Shielding 100S Ver B ITS 4116 Base Shield Block Spacer Block Structural Integrity 100S Ver B ITS 4116 Top Plate Structural Integrity 100S Ver B, 100S ITS 3669, 4116 Ver C MPC Support Structural Integrity 100S Ver B ITS 4116 Base and Lid N/A 100S Ver B NITS 4116 Screen Mounts Base and Lid Lift N/A 100S Ver B, 100S NITS 3669, 4116 Plug Ver C Shield Concrete Shielding 100S Ver B, 100S ITS 3669, 4116 Ver C MPC Guide N/A 100S Ver B NITS 4116 Lid Outer Ring Structural Integrity 100S Ver B, 100S ITS 3669, 4116 Ver C Lid Inner Ring Structural Integrity 100S Ver B, 100S ITS 3669, 4116 Ver C Lid Stud Pipe N/A 100S Ver B, 100S NITS 3669, 4116 Ver C Lid Stud Spacer N/A 100S Ver B, 100S NITS 3669, 4116 Ver C Lid Stud Ring N/A 100S Ver B, 100S NITS 3669, 4116 Ver C Lid Lift Block Structural Integrity 100S Ver B, 100S ITS 3669, 4116 Ver C Lid Lift Ring N/A 100S Ver B100S, NITS 3669, 4116 Ver C Lid Vent Shield Shielding 100S Ver B, 100S ITS 3669, 4116 Ver C Lid Shield Shielding 100S Ver B, 100S ITS 3669, 4116 Concrete Ver C HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-12

ATTACHMENT 1 TO HOLTEC LETTER 5014923 35 of 186 Subcomponent Intended FunctionNote Overpack Safety Class Licensing 1,3 ModelNote 2 Drawing Number Lid Stud Structural Integrity 100S Ver B, 100S ITS 3669, 4116 Ver C Lid Closure Bolt Structural Integrity 100S Ver B, 100S ITS 3669, 4116 Ver C Lid Bolt Handle N/A 100S Ver B, 100S NITS 3669, 4116 Ver C Lid Stud Washer Structural IntegrityN/A 100S Ver B, 100S ITS 3669, 4116 Ver C Lid Hex Nut Structural Integrity 100S Ver B, 100S ITS 3669, 4116 Ver C Lid Stud Cap N/A 100S Ver B, 100S NITS 3669, 4116 Ver C Lid Vent Seal N/A 100S Ver B NITS 4116 Cask Radial Structural Integrity 100S Ver B ITS 4116 Gusset Radial Rib Structural Integrity 100S Ver C ITS 3669 Lid Shim N/A 100S Ver C NITS 3669 Closure Lid Shielding 100U ITS 4501 Concrete Closure Lid Steel Structural Integrity, 100U ITS 4501 Shielding Container Shell Structural Integrity 100U ITS 4501 Bottom Plate Container Flange Structural Integrity 100U ITS 4501 Divider Shell and Heat Transfer 100U ITS 4501 Divider Shell Restraints Upper and Lower Structural Integrity 100U ITS 4501 MPC Guides MPC Bearing Pads Structural Integrity 100U ITS 4501 Insulation Structural Integrity 100U ITS 4501 Sub-grade Shielding, Structural 100U ITS 4501 Integrity Reinforced Structural Integrity 100U ITS 4501 Concrete; VVM Interface Pad, Top Surface Pad Retaining Wall, Structural Integrity, 100U ITS 4501 Support Shielding Foundation Pad Lid Rib Structural Integrity 100S Ver E ITS 11371 MPC Bottom Structural Integrity 100S Ver E ITS 11371 Support Guides HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-13

ATTACHMENT 1 TO HOLTEC LETTER 5014923 36 of 186 (1) Intended Functions are based on Section 2.1, Criterion 1 - Criticality control, heat transfer, radiation shielding, confinement, and structural integrity. These intended functions are for the renewal period.

(2) Unless otherwise noted, 100 denotes both the HI-STORM 100 and 100A, and 100S denotes both the HI-STORM 100S (Versions B, C, and E) and 100SA (3) N/A means the component does not have a function in the period of extended operation and is NITS.

These components are not included in the aging management review tables in Chapter 3./

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-14

ATTACHMENT 1 TO HOLTEC LETTER 5014923 37 of 186 Table 2.2 Intended Safety Functions of HI-TRAC Transfer Cask Subcomponents Subcomponent Intended Transfer Cask Safety Class Licensing FunctionNote 1,2 Model Drawing Number Radial Lead Shield Shielding 100, 100D, 125, ITS 1880, 1928, 2145, 125D, MS 2152, 3768, 4128, 11381 Pool Lid Lead Shielding 100, 100D, 125, ITS 1880, 1928, 2145, Shielding 125D 2152, 3768, 4128, Top Lid Shielding Shielding 100, 100D, 125, ITS 1880, 1928, 2145, 125D 2152, 3768, 4128, Outer Shell Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D, MS 2152, 3768, 4128, 11381 Inner Shell Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D, MS 2152, 3768, 4128, 11381 Enclosure Shell Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, Panels 125D 2152, 3768, 4128, Water Jacket End Structural Integrity, 100, 100D, 125, ITS 1880, 1928, 2145, Plate Shielding 125D 2152, 3768, 4128, Top Flange Structural Integrity, 100, 100D, 125, ITS 1880, 1928, 2145, Shielding 125D, MS 2152, 3768, 4128, 11381 Lower Water Jacket Structural Integrity, 100, 100D, 125, ITS 1880, 1928, 2145, Shell Shielding 125D, MS 2152, 3768, 4128, 11381 Water Jacket Structural Integrity, 100, 100D, 125, ITS 1880, 1928, 2145, Bottom Ring Shielding 125D 2152, 3768, 4128, Water Jacket Top Structural Integrity, 100, 100D, 125, ITS 1880, 1928, 2145, Plates Shielding 125D 2152, 3768, 4128, Bottom Flange Structural Integrity, 100, 100D, 125, ITS 1880, 1928, 2145, Shielding 125D, MS 2152, 3768, 4128, 11381 Bottom Flange N/A 100, 100D, 125, NITS 1880, 1928, 2145, Washer 125D 2152, 3768, 4128, Pool Lid Outer Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, Ring 125D 2152, 3768, 4128, Pool Lid Top Plate Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D 2152, 3768, 4128, Top Lid Outer Ring Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D 2152, 3768, 4128, Top Lid Inner Ring Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D 2152, 3768, 4128, HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-15

ATTACHMENT 1 TO HOLTEC LETTER 5014923 38 of 186 Subcomponent Intended Transfer Cask Safety Class Licensing FunctionNote 1,2 Model Drawing Number Top Lid Top Plate Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D 2152, 3768, 4128, Top Lid Bottom Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, Plate 125D 2152, 3768, 4128, Fill Port Caps Structural 100, 100D, 125, ITS 1880, 1928, 2145, IntegrityN/A 125D 2152, 3768, 4128, Pool Lid Bolt Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D, MS 2152, 3768, 4128, 11381 Lifting Trunnion Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, Block 125D 2152, 3768, 4128, Lifting Trunnion Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, and End Cap 125D 2152, 3768, 4128, Pocket Trunnion Structural Integrity 100, 125 ITS 1880, 1928, 2145, 2152 Dowel Pins Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D 2152, 3768, 4128, Water Jacket Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, Bottom Plate 125D 2152, 3768, 4128, Pool Lid Bottom Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, Plate 125D, MS 2152, 3768, 4128, 11381 Top Lid Lifting Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, Block 125D 2152, 3768, 4128, Bottom Flange Structural Integrity 100D,125D ITS 3678,4128 Gussets Thermal Expansion N/A 100, 100D, 125, NITS 1880, 1928, 2145, Foam 125D 2152, 3768, 4128, Top Lid Stud/Bolt Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, 125D 2152, 3768, 4128, Top Lid Structural Integrity 100, 100D, 125, ITS 1880, 1928, 2145, Nut/Washer 125D 2152, 3768, 4128, Pool Lid Gasket N/A 100, 100D, 125, NITS 1880, 1928, 2145, 125D 2152, 3768, 4128, End Cap Bolts N/A 100, 100D, 125, NITS 1880, 1928, 2145, 125D, MS 2152, 3768, 4128, 11381 Drain Pipes N/A 100, 100D, 125, NITS 1880, 1928, 2145, 125D 2152, 3768, 4128, Drain Bolt N/A 100, 100D, 125, NITS 1880, 1928, 2145, 125D 2152, 3768, 4128, Lifting Trunnion N/A 100, 100D, 125, NITS 1880, 1928, 2145, Pad Bolt 125D 2152, 3768, 4128, HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-16

ATTACHMENT 1 TO HOLTEC LETTER 5014923 39 of 186 Subcomponent Intended Transfer Cask Safety Class Licensing FunctionNote 1,2 Model Drawing Number Couplings, Valves, N/A 100, 100D, 125, NITS 1880, 1928, 2145, and Vent Plug 125D, MS 2152, 3768, 4128, 11381 Transfer Lid Side Shielding 100, 125 ITS 1880, 1928, 2145, Lead Shield 2152 Transfer Lid Door Shielding 100,125 ITS 1880, 1928, 2145, Lead Shield 2152 Transfer Lid Door Shielding 100,125 ITS 1880, 1928, 2145, Shielding 2152 Transfer Lid Top Structural Integrity 100,125 ITS 1880, 1928, 2145, Plate 2152 Transfer Lid Structural Integrity 100,125 ITS 1880, 1928, 2145, Bottom Plate 2152 Transfer Lid Structural Integrity 100,125 ITS 1880, 1928, 2145, Intermediate Plate 2152 Transfer Lid Lead Structural Integrity 100,125 ITS 1880, 1928, 2145, Cover Plate 2152 Transfer Lid Lead Structural Integrity 100,125 ITS 1880, 1928, 2145, Cover Side Plate 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Top Plate 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Middle Plate 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Bottom Plate 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Wheel Housing 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Interface Plate 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Side Plate 2152 Transfer Lid Wheel Structural Integrity 100,125 ITS 1880, 1928, 2145, Shaft 2152 Transfer Lid Shaft Structural Integrity 100,125 ITS 1880, 1928, 2145, Cover Plate 2152 Transfer Lid Structural Integrity 100,125 ITS 1880, 1928, 2145, Housing Stiffener 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Lock Bolt 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, End Plate 2152 Transfer Lid Lifting Structural Integrity 100,125 ITS 1880, 1928, 2145, Lug and Pad 2152 HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-17

ATTACHMENT 1 TO HOLTEC LETTER 5014923 40 of 186 Subcomponent Intended Transfer Cask Safety Class Licensing FunctionNote 1,2 Model Drawing Number Transfer Lid Wheel Structural Integrity 100,125 ITS 1880, 1928, 2145, Track N/A 2152 Transfer Lid Door N/A 100,125 NITS 1880, 1928, 2145, Handle 2152 Transfer Lid Door N/A 100,125 NITS 1880, 1928, 2145, Wheels 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Stop Block N/A 2152 Transfer Lid Door Structural Integrity 100,125 ITS 1880, 1928, 2145, Stop Block Bolt N/A 2152 Hydraulic System N/A 100, 125 NITS Not shown Short Rib Structural Integrity, MS ITS 11381 Heat Transfer Extended Rib Structural Integrity, MS ITS 11381 Heat Transfer (1) Intended Functions are based on Section 2.1, Criterion 1 - Criticality control, heat transfer, radiation shielding, confinement, and structural integrity. These intended functions are for the renewal period.

(2) N/A means the component does not have a function in the period of extended operation and is NITS. These components are not included in the aging management review tables in Chapter 3.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-18

ATTACHMENT 1 TO HOLTEC LETTER 5014923 41 of 186 Table 2.2 Intended Safety Functions of Fuel Assembly Subcomponents Item Subcomponent Intended FunctionNote 1,2 No.

1 Fuel Pellets N/A 2 Fuel Cladding Criticality Control, Confinement, Structural Integrity 3 Spacer Grid Assemblies Criticality Control, Structural Integrity 4 Upper End Fitting Structural Integrity 5 Lower End Fitting Structural Integrity 6 Guide Tubes Structural Integrity 7 Hold-down Spring & Upper End N/A Plugs 8 Control Components N/A 9 Channels for BWR fuel N/A Notes:

(1) Intended Functions are based on Section 2.1, Criterion 1 - Criticality control, heat transfer, radiation shielding, confinement, and structural integrity (2) N/A means the subcomponent does not have a function in the period of extended operation. These components are not included in the aging management review tables in Chapter 3.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-19

ATTACHMENT 1 TO HOLTEC LETTER 5014923 42 of 186 2.3 References

[2.1.1] NUREG-1927, Standard Review Plan for Renewal of Specific Licenses and Certificates of Compliance for Dry Storage of Spent Nuclear Fuel, Revision 1. US NRC, June 2016.

[2.1.2] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 0, dated July 12, 2000

[2.1.3] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 1, dated September 17, 2002

[2.1.4] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 2, dated February 17, 2004

[2.1.5] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 3, dated May 26, 2005

[2.1.6] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 4, dated April 10, 2006

[2.1.7] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 5, date June 20, 2007

[2.1.8] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 6, dated February 7, 2008

[2.1.9] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 7, dated August 8, 2008

[2.1.10] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 8, dated January 18, 2010

[2.1.11] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 9, dated February 13, 2010

[2.1.12] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 10, dated April 24, 2012

[2.1.13] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 11, dated July 27, 2013

[2.1.14] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 11.1, dated February 26, 2016

[2.1.15] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 12, dated March 12, 2014

[2.1.16] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 13, dated March 31, 2016

[2.1.17] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 14, dated November 18, 2016

[2.1.18] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 15, dated April 27, 2018

[2.1.19] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 16, dated April 18, 2019

[2.1.20] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 17, dated May 3, 2019

[2.1.21] Holtec Report, HI-2002444, HI-STORM 100 FSAR Rev 18, dated May 16, 2019

[2.1.22] HI-STORM 100 CoC 72-1014 Amd 0, dated May 31, 2000 HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-20

ATTACHMENT 1 TO HOLTEC LETTER 5014923 43 of 186

[2.1.23] HI-STORM 100 CoC 72-1014 Amd 1, dated July 15, 2002

[2.1.24] HI-STORM 100 CoC 72-1014 Amd 2, dated June 7, 2005

[2.1.25] HI-STORM 100 CoC 72-1014 Amd 3, dated May 29, 2007

[2.1.26] HI-STORM 100 CoC 72-1014 Amd 4, dated January 8, 2008

[2.1.27] HI-STORM 100 CoC 72-1014 Amd 5, dated July 14, 2008

[2.1.28] HI-STORM 100 CoC 72-1014 Amd 6, dated August 17, 2009

[2.1.29] HI-STORM 100 CoC 72-1014 Amd 7, dated December 28, 2009

[2.1.30] HI-STORM 100 CoC 72-1014 Amd 8, dated November 16, 2012 (corrected, then superseded by Rev 1)

[2.1.31] HI-STORM 100 CoC 72-1014 Amd 8R1, dated February 16, 2016

[2.1.32] HI-STORM 100 CoC 72-1014 Amd 9, dated March 11, 2014 (then superseded by Rev 1)

[2.1.33] HI-STORM 100 CoC 72-1014 Amd 9R1, dated March 21, 2016 (corrected)

[2.1.34] HI-STORM 100 CoC 72-1014 Amd 10, dated May 31, 2016 (corrected)

[2.1.35] HI-STORM 100 CoC 72-1014 Amd 11, dated February 25, 2019 (corrected)

[2.1.36] HI-STORM 100 CoC 72-1014 Amd 12, dated February 25, 2019 (corrected)

[2.1.37] HI-STORM 100 CoC 72-1014 Amd 13, dated May 13, 2019 (corrected)

[2.1.38] HI-STORM 100 CoC 72-1014 Amd 14, dated December 17, 2019 (corrected)

[2.1.39] HI-STORM 100 CoC 72-1014 Amd 15 (under review at time of renewal application)

[2.1.40] HI-992332, ITS Categorization of HI-STAR 100, HI-STORM 100, and Cask Transfer Facility System Components, latest revision.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 2-21

ATTACHMENT 1 TO HOLTEC LETTER 5014923 44 of 186 CHAPTER 3: AGING MANAGEMENT REVIEW 3 Introduction The HI-STORM 100 dry storage system, US NRC Certificate of Compliance (CoC) 1014, has a life that is broken down into three classifications. The first classification, the license life of the system, is the amount of time that the system has been licensed by the NRC for use in dry storage. The second classification, a design life of 60 years is the length of time for which the storage system has been engineered to perform all of its design functions. The final classification is the minimum service life of 100 years, which is contingent upon at least two license renewals beyond the original license life.

Because the HI-STORM 100 dry storage system is nearing the end of its initial 20 year license life and the US NRC requires an aging management program be put in place in order to complete the license renewal for the next 40 year license life, this chapter presents the Aging Management Review (AMR) for the HI-STORM 100 system. The purpose of the AMR is to assess the aging effects and mechanisms that could adversely affect the ability of the system, structures, or components (SSC), determined to be within the scope of the license renewal, to perform their intended functions during the period of extended storage.

The aging management program must take into account the intended function of each SSC, its material, and the environment in which it was used to determine what activities are needed. The US NRC guidance for the aging management program is contained in NUREG-1927 [2.1.1]. Additional guidance is contained in the NRCs MAPS Report, NUREG-2214, and is reflected in the information in this section.

3.1 Operating Experience Review 3.1.1 Holtec Operating Experience Holtec has prepared a report of manufacturing deviations and of engineering change orders (ECOs) that have happened over the life of the system [3.1.1] and [3.1.2]. These reports document specific items that were considered in the development of aging management activities.

3.1.2 User Operating Experience A survey of the users of the HI-STORM 100 system was performed to evaluate if there was any operating experience or inspection results that would impact the aging of the system. This survey found the following items:

o Dime size rust on the lift block o Quarter size rust below the top vent o Minor discoloration on the gamma shield o Minor visible rust under degraded coating at bottom of cask o Rust streaks below the vent screens o Rust around weep holes on cask lids HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-1

ATTACHMENT 1 TO HOLTEC LETTER 5014923 45 of 186 o Minor rust spots (approximately 1/2 by 3, or 1 by 4) due to chipped paint o Threaded hole area rust

  • Minor Overpack Concrete Degradation o Small evidence of degradation near vents due to use of de-icer o Shrinkage cracks, typically 0.004 inches or less o Minor spalling o Minor surface damage o Minor paint loss o Small scratches
  • HI-TRAC o Minor paint degradation o Minor paint loss
  • MPC o Marks (fabrication marks / dog marks) found on exterior of MPC, evaluated at site and determined to be acceptable o Minor blemishes due to potential carbon steel contamination, which were removed by Scotchbrite o Other carbon steel contamination near welds All conditions previously seen are monitored by the aging management programs described for the applicable components. The types of corrosion previously seen were utilized in determining the criteria for future inspections. Trending of these conditions and corrective actions, as necessary, are also part of the aging management programs. Note that the reviewed operating experience is about the in scope subcomponents, out of scope components listed in Section 2 were not evaluated. Additional operating experience was gathered from some system inspections as described in Appendix C.

The aging management programs in Appendix A were developed including consideration for this operating experience.

3.1.3 User Exemption Requests This section evaluates the exemption requests granted to specific sites that were identified to Holtec at the time of writing of this application. Users should consider any other or future exemption requests and their impact on aging management.

One user applied for and was granted an exemption from 10 CFR 72.212 and 214 which allowed for storage of specific fuel types. That exemption was approved in 2001, and subsequently the fuel types were added to the generic CoC. Therefore, no specific aging management considerations are needed for this exemption. Similarly, an exemption was issued for specific fuel heat loading plans in 2018, which were subsequently incorporated into the generic CoC, and no specific aging management considerations are needed.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 46 of 186 An exemption was requested and granted for the storage of a thoria rod canister in an MPC-68M. These thoria rods were added during a subsequent amendment to the CoC and therefore, no specific aging management considerations are needed for this exemption.

An exemption was granted related to fuel that released some radioactive gases during drying, to allow the canister to be placed into storage that includes fuel that may have cladding damage not in a damaged fuel container (DFC). This exemption only impacts the fuel within the canisters inert helium environment and does not change the aging management programs.

Additionally an exemption was requested and granted regarding the location of dose rate measurements on the HI-STORM 100 overpack. This related to a one time, post-loading surveillance and does not impact the aging of the system.

3.2 Aging Management Review Methodology As described in NUREG-1927 [2.1.1], the aging management review process is broken down into a number of steps. The first step is determining the in-scope SSC subcomponents that require aging management review, followed by identification of the aging effects requiring management, and finally identification of the necessary management activities for each affected subcomponent. Aging management activities can either be Time Limited Aging Analyses (TLAAs) or Aging Management Programs (AMPs) depending on the component material, service environment, and existing licensing basis calculations.

3.2.1 Identification of In-Scope SSCs Requiring Aging Management Review As discussed in Chapter 2, all SSC subcomponents that perform or support any of the identified, intended functions in a passive manner are in-scope for license renewal and are therefore, in-scope for aging management review. These subcomponents are presented in Table 3.3-1 through Table 3.3-5.

Any SSC subcomponents that do not perform or support an intended function or already have their condition monitored at some established frequency are excluded from further evaluation in the aging management review.

3.2.2 Identification of Materials and Environments A detailed description of the HI-STORM 100 system and the materials used in the SSCs are described in the HI-STORM 100 FSAR. A breakdown of each SSC subcomponent in-scope for aging management, with its intended function, material, and service environment is contained in Table 3.3-1 through Table 3.3-5. Note that subcomponents which do not have a safety function or support a safety function are not required to undergo aging management. A summary of the materials used in the aging management assessment is provided in Table 3.2-1.

A generic description of the four basic environments is provided below.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-3

ATTACHMENT 1 TO HOLTEC LETTER 5014923 47 of 186 3.2.2.1 Helium The helium environment refers to the inside of the MPC, which is backfilled with inert helium gas. Based on the canister drying process, the environment has negligible amounts of oxygen or moisture. The helium environment is exposed to the range of temperatures calculated for the MPC and significant radiation impacts from the stored fuel.

3.2.2.2 Sheltered Environment The term sheltered environment refers to environments that may include ambient air, but are shielded from sunlight, rain, or wind exposure. One sheltered environment in the HI-STORM 100 System design is the annular space between the overpack and the MPC. The ambient air contains moisture, salinity, or other contaminants typical for the site where it is stored. The temperature of the sheltered environment is within the limits of the air temperature passing through the annular space.

Additionally, the term sheltered is used to refer to the interior of a storage building, which provides protection from direct sunlight, rain, and wind. However the building air may not be conditioned by HVAC equipment.

3.2.2.3 Embedded Environment The embedded environment applies to materials that are embedded or sealed inside another material.

Items in this environment include the internal metal items of the overpack. The embedded items are exposed to the temperatures of the components in which they are embedded.

3.2.2.4 Air-Outdoor Environment The term Air-Outdoor environment is used for exterior surfaces that are exposed to direct sunlight, wind, rain, and other weather aspects. Items in an air-outdoor environment in the HI-STORM 100 System are the overpacks. The air-outdoor environment has temperature ranges equivalent to the site ambient temperature ranges.

3.2.3 Identification of Aging Effects Requiring Management After the materials and environments have been identified, the next step involves determining the aging effects requiring management. Aging effects requiring management during the renewed license period are those that could cause a loss of SSC intended function. If degradation of a subcomponent would be insufficient to cause a loss of function or the relevant conditions do not exist for the aging effect to occur and propagate, then no aging management is required. These aging effects were determined based on the combination of materials and environments and a review of known literature, NRC MAPS report (NUREG-2214) [3.0.1], industry operating experience, and maintenance and inspection records from general licensees (such as condition reports and inspection reports). Both potential aging effects that could HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-4

ATTACHMENT 1 TO HOLTEC LETTER 5014923 48 of 186 theoretically occur, as well as aging effects that have actually occurred based upon industry operating experience were considered.

Aging effects occur due to aging mechanisms. In order to manage aging effects, the aging mechanism that could be at work based on material and environment, must be determined. Therefore, the AMR process identifies both aging effects and the aging mechanism causing that effect. The aging effects and mechanisms for each SSC are broken down by subcomponent in Table 3.3-1 through Table 3.3-5. Since the tables in Chapter 2 already determine which subcomponents have ITS related functions into the extended storage period, and the subcomponents that do not have not been included in these tables.

3.2.4 Determination of Aging Management Activity Required The final step in the AMR process is to determine the aging management activity or program to manage the effect of aging. As much as possible, existing ISFSI programs and activities were credited to manage aging effects that could cause a loss of intended function during the renewed license period.

As described in NUREG-1927 [Ref. 2.1.1], there are two options for managing aging effects on components; a time-limited aging analysis (TLAA) or an aging management program (AMP).

3.2.4.1 Time-Limited Aging Analysis (TLAA)

A Time-Limited Aging Analysis (TLAA) is a licensee or CoC holder calculation or analysis that meets all of the following attributes, as defined in 10CFR72.3:

  • Involves SSCs important to safety within the scope of license or CoC renewal,
  • Considers the effects of aging,
  • Involves time-limited assumptions defined by the current operating term
  • Was determined to be relevant by the licensee or CoC holder in making a safety determination
  • Involves conclusions or provides the basis for conclusions related to the capability of the SSCs to perform their intended safety functions, and

3.2.4.2 Aging Management Program (AMP)

An Aging Management Program (AMP) is a program conducted by the licensee or Certificate of Compliance (CoC) user for the purposes of addressing the aging effects in accordance with NUREG-1927.

The program may include prevention, mitigation, condition monitoring, and/or performance monitoring.

These AMPs are to be started as the HI-STORM 100 systems reach the end of their initial license life and intended to support the HI-STORM 100 systems during their renewed license periods. The use of an AMP to address these aging mechanisms does not always mean that the specific subcomponent is inspected under the AMP, but that the information gained from the applicable AMP used as a whole provides reasonable assurance that the listed subcomponents maintain their function.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-5

ATTACHMENT 1 TO HOLTEC LETTER 5014923 49 of 186 Table 3.2-1 Summary of Materials Term Usage in this Document Aluminum Includes pure aluminum and alloys Boral A laminate composite that is used as a neutron poison material. It consists of a core of aluminum and boron-carbide powder sandwiched between sheets of aluminum.

Metamic Aluminum metal-matrix composite for neutron poison applications, produced by cold isostatic pressing followed by vacuum sintering.

Metamic-HT A successor to the Metamic composite material.

It possesses the necessary mechanical properties for structural fuel basket applications by strengthening its aluminum matrix with nanoparticles of aluminum oxide.

Concrete A mixture of hydraulic cement, aggregates, and water, with or without admixtures, fibers, or other cementitious materials.

Holtite-A A neutron shielding material consisting of epoxy polymer, B4C added as a finely divided powder, and aluminum hydroxide.

Nickel Alloy Includes Inconel, which is a family of austenitic nickel-chromium-based super alloys.

Alloy X Stainless or duplex steel as defined in Appendix 1.A of the HI-STORM 100 FSAR Zirconium-based alloys Materials of construction of fuel cladding and fuel assembly hardware. Various zirconium-based materials have been used in commercial reactor applications because of their low neutron cross section and excellent corrosion resistance to a variety of environmental conditions. This category includes (but is not limited to) Zircaloy-2, Zircaloy-4, ZIRLO, and M5.

Carbon Steel Various carbon steels including ASTM A36, ASTM A320, SA193-Gr. B7, SA516-Gr. 70 HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-6

ATTACHMENT 1 TO HOLTEC LETTER 5014923 50 of 186 3.3 Aging Management Review Results 3.3.1 Aging Management Review Results - MPC Table 3.3-1 summarizes the results of the aging management review for the MPC subcomponents previously determined to be in the scope of the license renewal.

Additional description of the MPC subcomponents is provided in Section 3.3.1.1, while Sections 3.3.1.2 and 3.3.1.3 present the materials and environments for the specified subcomponents. The aging effects requiring management and the proposed activities required to manage these effects are discussed in Sections 3.3.1.4 and 3.3.1.5, respectively.

3.3.1.1 Description of MPC Subcomponents MPC Enclosure Vessel The MPC enclosure vessel is a welded cylindrical structure with flat ends that provides confinement of the spent nuclear fuel during storage operations. The confinement boundary, comprised of a baseplate, shell, lid, port covers, and a closure ring, is constructed entirely of stainless steel. The MPC lid is a circular plate edge-welded to the MPC shell. Access to the MPC cavity for the purposes of moisture removal and subsequent backfilling with a specified amount of inert gas (helium) is achieved via two penetrations (i.e.,

vent and drain ports) in the MPC lid. Circular cover plates are seal welded over the vent and drain ports, completing the primary closure system. A circular closure ring is welded to the MPC shell and lid, providing a redundant closure system at the top end of the MPC. A more detailed description is included in paragraph 1.1.2.1 of this report.

MPC Fuel Basket Within each MPC enclosure vessel is a honeycombed fuel basket responsible for maintaining the spent nuclear fuel in a subcritical condition. The number of fuel storage cells will vary depending on the type of fuel to be stored. The fuel basket is positioned and supported within the enclosure vessel by basket shims located in the space between the inside of the shell and the basket. Upper and lower fuel spacers, as appropriate, are utilized to maintain the axial position of the fuel assembly within the MPC basket.

Damaged Fuel Container (DFC) / Damaged Fuel Isolators (DFI)

The damaged fuel container is designed to contain damaged fuel or fuel debris. The internal opening accommodates a fuel assembly, and the outside dimensions allow the DFC to fit in the MPC Fuel Basket storage cells. The shells and lids of the DFCs are fabricated from stainless steel or aluminum. The ends have screened vent holes which enable moisture removal from the canister and expose the contents of the DFC to the helium atmosphere of the MPC.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-7

ATTACHMENT 1 TO HOLTEC LETTER 5014923 51 of 186 The damaged fuel isolators (DFI) are provided to contain damaged fuel that can be handled by normal means, and have similar screens to enable moisture removal.

3.3.1.2 MPC Materials With the exception of the neutron absorbers which are constructed of either BoralTM or Metamic, the basket in the MPC-68M/32M which is Metamic-HT, and some DFC/DFI designs which are constructed of aluminum, all other MPC subcomponents in the scope of the license renewal are constructed of stainless steel. Additional material details for the MPC subcomponents are provided in Table 3.3-1.

3.3.1.3 MPC Environments The environments that affect the subcomponents of each MPC, both externally and internally, are described below.

3.3.1.3.1 External Each MPC is stored in a vertical, ventilated overpack. Based on this design, the external surface of each MPC is exposed to the same environment as the inside of the overpack (described in Subsection 3.3.2),

which is a sheltered environment protected from precipitation and wetting. This sheltered environment includes ambient air, but not direct sunlight, rain, or wind exposure. The ambient air may contain some moisture and contaminants. The normal operating temperature of the outside MPC surface is highest at the top. Maximum surface temperature limits are unchanged. While these temperatures may vary across the amendments of the HI-STORM 100 CoC, the variation in temperature does not change the potential aging mechanisms, and therefore does not change the programs needed to manage them.

3.3.1.3.2 Internal The internal environment of the MPC is a helium environment that is completely filled with the inert helium gas. The previously licensed maximum surface temperature limits are assumed to continue into the license renewal period. While these temperatures may vary across the amendments of the HI-STORM 100 CoC, the variation in temperature does not change the potential aging mechanisms, and therefore does not change the programs needed to manage them.

3.3.1.4 Aging Effects Requiring Management (MPC)

Based on the MPC materials of construction and the environments experienced during the period of extended storage at the ISFSI, the aging effects requiring management are loss of material, cracking (due to corrosion and stress corrosion cracking on the external MPC surfaces) and radiation effects on the neutron absorber and steel components.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-8

ATTACHMENT 1 TO HOLTEC LETTER 5014923 52 of 186 3.3.1.5 Aging Management Activities (MPC)

Based on the aging management review of the MPC subcomponents documented in Table 3.3-1, an AMP is required for the aging management activities of the MPC and a TLAA is required specifically for the effects of radiation on the neutron absorber and steel components. These aging management activities are discussed in detail in Sections 3.4 and 3.5.

3.3.2 Aging Management Review Results - HI-STORM 100 Overpack Table 3.3-2 summarizes the results of the aging management review for the HI-STORM 100 overpack subcomponents previously determined to be in the scope of the license renewal.

Additional description of the overpack subcomponents is provided in Section 3.3.2.1, while Sections 3.3.2.2 and 3.3.2.3 present the materials and environments for the specified subcomponents. The aging effects requiring management and the proposed activities required to manage these effects are discussed in Sections 3.3.2.4 and 3.3.2.5, respectively.

3.3.2.1 Description of Overpack Subcomponents The overpack provides structural support, shielding, and natural circulation cooling for the MPC. The overpack is ventilated by internal air flow paths which allow the decay heat to be removed by natural circulation around the metal MPC wall. An airflow path is formed by the openings at the bottom (air entrance), the air inlet ducts, the gap between the MPC exterior and the overpack interior, and the air outlet ducts at the top. The internal cavity of the overpack is formed by a coated steel liner and bottom plate.

The steel and concrete walls of the overpack are designed to minimize side surface radiation dose rates.

The steel liner is coated to promote radiant heat dissipation and to minimize corrosion. The overpack lid is fabricated from steel and concrete and provides additional gamma attenuation in the upward direction, reducing both direct radiation and skyshine. The overpack lid is bolted in place, and also protects the MPC from the environment and postulated tornado missiles. A more detailed description is included in paragraph 1.1.2.2 of this report. The list of subcomponents evaluated under the overpack aging management review also includes the components of the HI-STORM 100U.

3.3.2.2 Overpack Materials The HI-STORM 100 overpack is constructed of carbon steel, with exposed surfaces coated to protect against corrosion, and filled with concrete. The concrete in the cask shell is in direct contact with steel.

Concrete has been used with steels in many commercial applications including Reactor Containment Buildings (e.g., carbon steel reinforcement, stainless steel liner). Similarly, as concrete is a standard construction material used for civil projects such as dams, buildings, and bridges that are exposed to severe environmental conditions, no adverse concrete reactions associated with weather are anticipated.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-9

ATTACHMENT 1 TO HOLTEC LETTER 5014923 53 of 186 Internal and external surfaces are painted (except for bolt location that have protective coating).

Thermaline 405 or a functionally equivalent paint/coating is used to coat the overpack. The coating also prevents the carbon steel in the overpack from coming in contact with the stainless steel MPC.

Additional material details for the HI-STORM 100 overpack subcomponents are provided in Table 3.3-2.

3.3.2.3 Overpack Environments The HI-STORM 100 overpacks are located outdoors at their storage site. The temperatures for the overpacks are bounded by the temperatures in Table 2.2.2 of the HI-STORM FSAR [2.1.21]. The interior components of the overpacks are exposed to a sheltered environment. This environment includes ambient air through the air passages, but does not include sun, rain, or wind exposure. The ambient air may contain moisture, salinity, or other contaminants.

The metal components of the overpack that are in contact with concrete, such as the outer surface of the inner shell, are considered to be in an embedded environment. The primary concern for embedded environments is the potential chemical reaction between the two materials. The interactions between materials of the HI-STORM 100 overpack subcomponents are described in Section 3.3.2.2, and are not considered to be of concern for the extended storage period.

The exterior surfaces of the overpacks are exposed to all weather-related effects, including insolation, wind, rain, snow, ice, ambient air, and other environmental debris at their storage sites, and are considered to be in an air-outdoor environment. Additionally, the overpacks are exposed to radiation effects from the MPCs stored inside.

3.3.2.4 Aging Effects Requiring Management (Overpack)

Based on a review of the overpack materials of construction and the environments experienced during the period of extended storage at the ISFSI sites the main aging effects requiring management are loss of material due to corrosion, loss of fracture toughness (due to radiation impacts) for the metal components, and concrete aging issues caused by freeze thaw cycles, alkali-silica reaction, and/or calcium hydroxide leaching.

3.3.2.5 Aging Management Activities (Overpack)

Based on the aging management review of the overpack subcomponents documented in Table 3.3-2, it has been determined that the aging management activities required for the overpack are an AMP for the overpack and a separate AMP for the HI-STORM 100U components (if used). These aging management activities are discussed in detail in Section 3.5. For those components potentially impacted by radiation, the radiation impacts have been evaluated and determined that no additional aging management activities beyond those in the Overpack AMP are needed. A TLAA is not required by definition since this analysis was not part of the initial licensing basis.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-10

ATTACHMENT 1 TO HOLTEC LETTER 5014923 54 of 186 The ceramic fiber (Kaowool) used in the overpack has an aging mechanism offor concern when exposed to high radiations. The high radiations maywill result in reduction of thermal conductivity of the component material due to presence of cracks or air pockets. Since the ceramic fiber is used only for the purpose of insulating purposeson, and the reduction in thermal conductivity is conservative for the HI-STORM 100U system as a whole is insignificant even if there were a complete failure of the components thermal capabilities. Therefore, the Kaowool ceramic fiber insulation has not been incorporated into the Section 3.5no TLAA or Aging Management ProgramMP is required.

3.3.3 Aging Management Review Results - Fuel Assembly Table 3.3-3 summarizes the results of the aging management review for the Fuel Assembly subcomponents previously determined to be in the scope of the license renewal.

Additional description of the fuel assembly subcomponents is provided in Section 3.3.3.1, while Sections 3.3.3.2 and 3.3.3.3 present the materials and environments for the specified subcomponents. The aging effects requiring management and the proposed activities required to manage these effects are discussed in Sections 3.3.3.4 and 3.3.3.5, respectively.

3.3.3.1 Description of Fuel Assembly Depending on the MPC model being used, the fuel contained within consists of either 24 PWR fuel assemblies, 32 PWR fuel assemblies, or 68 BWR fuel assemblies. The maximum heat loads, minimum cooling times, and maximum burnups vary based on the selected MPC and loading options, however, this application evaluates the bounding information if necessary.

The cladding of the fuel assembly provides the primary confinement barrier, while the physical structure of the fuel assembly maintains the axial distribution of the radiological source and its position within the gridwork of the fuel basket. The fuel pellets, hold-down springs and upper end plugs, and control components were excluded from further aging management review because they do not support or impact the intended function of the fuel assemblies during the extended storage period.

3.3.3.2 Fuel Assembly Materials The fuel assembly subcomponents included in the aging management review are made from zircaloy, stainless steel, and/or Inconel. Additional material details for the Fuel Assembly subcomponents are provided in Table 3.3-3.

3.3.3.3 Fuel Assembly Environments Because the MPC is sealed, dried, and backfilled with helium prior to entering storage, the fuel assemblies are maintained in a very low moisture, helium environment. The temperatures range from the maximum value corresponding to the short term limit for a maximum canister heat load to the minimum ambient air temperature as the heat load reduces over time.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-11

ATTACHMENT 1 TO HOLTEC LETTER 5014923 55 of 186 3.3.3.4 Aging Effects Requiring Management (Fuel Assembly)

The fuel assemblies stored in the HI-STORM 100 system are classified as moderate-burnup fuel (45,000 MWd/MTU) or high-burnup fuel (>45,000 MWd/MTU).

For the moderate-burnup fuel, cladding embrittlement due to irradiation damage or hydride formation is not a concern. A report prepared by Pacific Northwest National Laboratory (PNNL-14390 [3.3.1]),

documenting research conducted by EPRI and the US Department of Energy, confirms that similar, non-high-burnup fuel assemblies stored in a helium environment, like the one present inside the MPC, do not exhibit detectable degradation of the cladding or more than negligible release of gaseous fission products during storage. Therefore, no aging effects requiring management are identified for the low burnup fuel assemblies.

For the high burnup fuel, the acceptability of storage for the initial 20 years is based on ISG-11, Rev 3

[3.3.2]. This basis may not be applicable for high burnup fuel storage beyond 20 years, due to the potential for further cooldown in the high burnup fuel cladding temperature during the extended 60-year renewal period. As the high burnup fuel cools down below the ductile-to-brittle transition temperature (DBTT),

the formation of radial hydrides may provide an additional embrittlement mechanism to alter the acceptance criteria of ISG-11 for storage of high burnup fuel. This embrittlement is considered an aging effect that requires management into the extended storage period.

3.3.3.5 Aging Management Activities (Fuel Assembly)

Based on the above review, it is determined that an AMP is needed for high burnup fuel. NRC ISG-24

[3.3.3] provides guidance for the storage of high burnup fuel for periods greater than 20 years, and specifies that the applicant may use the results of a completed or an ongoing demonstration, in conjunction with an actively updated AMP, as an acceptable means for confirming that the canister contents satisfy the applicable regulations. ISG-24 further specifies that the high burnup fuel AMP should be periodically reviewed and updated whenever new data from the demonstration program or other short term tests or modeling indicate potential degradation of the fuel or deviation from the assumptions of the AMP.

The Fuel Assembly AMP is described in Appendix A. Consistent with the guidance provided in NUREG-1927, the AMP takes credit for the DOE/EPRI High Burnup Dry Storage Cask Research and Development Project (HDRP).

3.3.4 Aging Management Review Results - HI-TRAC Transfer Cask Table 3.3-4 summarizes the results of the aging management review for the HI-TRAC Transfer Cask, previously determined to be in the scope of the license renewal.

Additional description of the HI-TRAC is provided in Section 3.3.4.1, while Sections 3.3.4.2 and 3.3.4.3 present the materials and environments. The aging effects requiring management and the proposed activities required to manage these effects are discussed in Sections 3.3.4.4 and 3.3.4.5, respectively.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-12

ATTACHMENT 1 TO HOLTEC LETTER 5014923 56 of 186 3.3.4.1 Description of HI-TRAC Transfer Cask The transfer cask is a steel, lead, steel layered cylinder with a water jacket attached to the exterior. The transfer cask provides an internal cylindrical cavity of sufficient size for housing an MPC, and is equipped with a seal designed to hold clean demineralized water in the inner cavity. This design prevents contamination of the exterior of the MPC by contaminated fuel pool water. The transfer cask is equipped with lifting trunnions, and in the case of the standard design HI-TRAC, with pocket trunnions to allow rotation of the HI-TRAC (see Paragraph 1.1.2.3).

3.3.4.2 HI-TRAC Transfer Cask Materials The HI-TRAC structure is fabricated from carbon steel. Other materials included in the HI-TRAC design are lead (for gamma shielding), Inconel (for lifting trunnions), Holtite (in transfer lid for standard designs),

and elastomer (in the seal). The Holtite and lead shielding materials are completely enclosed, and therefore there are no significant galvanic or chemical reactions between these materials and the air or borated water. As identified in the HI-STORM 100 FSAR [2.1.21], the exposed carbon steel surfaces are coated in accordance with Appendix 1.C of the FSAR. This coating prevents corrosion and aids in surface decontamination.

The material of each Transfer Cask subcomponent is identified in Table 3.3-4.

3.3.4.3HI-TRAC Transfer Cask Environments The exterior of the HI-TRAC is exposed to water or borated water (PWR) during fuel loading (while the HI-TRAC was in an SFP), and to demineralized water in the annulus. Following fuel loading of the MPC, the HI-TRAC is removed from the SFP.

The HI-TRAC is exposed to either a sheltered environment, if stackup is performed in the building or an air-outdoor environment if stackup is performed outside. The relatively brief exposure of the HI-TRAC to borated and demineralized water while in the SFP and the outside environment during transfer and loading operations (if applicable), does not significantly contribute to the aging of the HI-TRAC during the renewal period. It is the prolonged or frequently recurring exposure to environmental conditions and stresses that must be evaluated for aging effects, such as those encountered during storage.

The environment to which the HI-TRAC is exposed during storage between use for MPC loading and transfers is usually sheltered within a building, but to be conservative and bound any sites which may store the HI-TRAC outside, the environment is considered to be ambient air.

3.3.4.4 Aging Effects Requiring Management for HI-TRAC Based on a review of the HI-TRAC materials of construction and the environments experienced during the period of extended storage at the ISFSI, the main aging effect requiring management is loss of material due to corrosion.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-13

ATTACHMENT 1 TO HOLTEC LETTER 5014923 57 of 186 3.3.4.5 Aging Management Activities for HI-TRAC Based on the aging management review of the HI-TRAC subcomponents documented in Table 3.3-4, the aging management activities required for the HI-TRAC are an AMP for the HI-TRAC, and a TLAA for the HI-TRAC trunnions.

The Holtite material used in the HI-TRAC also has an aging mechanism of concern related to its thermal and radiation aging. The current licensing basis does not include a specific time based evaluation of the material, so there is no analysis to meet the requirements to be classified a TLAA. The weight loss reduction experienced after thermal aging testing by Holtite-A during the Holtite-A qualification testing specified in [3.3.5], bounds the weight loss that will be experienced by thefor Holtite-A in a HI-TRAC during a 60-year timeframe. This determination is made when inputting a conservative expected exposure time over a 60-year timeframe and the maximum on-site transfer Holtite temperature (specified in Table 4.III.6 of [3.3.7]) into the temperature and exposure time parameterized weight reduction formula presented in Section 3.2 of [3.3.5] and comparing this value with the weight loss values specified for the samples in [3.3.5] after thermal aging testing. Furthermore, using a conservative exposure time over a 60-year timeframe and the bounding loading patterns considered for a 125-ton HI-TRAC loaded with an MPC-32, a shielding analysis [3.3.6] was performed and it was determined that the accumulated neutron fluence and gamma dose expected over a 60-year timeframe are well-below the accumulated neutron fluence and gamma dose during Holtite-A irradiation testing in [3.3.5]. The conservative testing conditions presented in test reports [3.3.4] and [3.3.5], demonstrate However, testing has been performed on the material and documented in [3.3.4] and [3.3.5], which show thatno Holtite-A showed negligible change in dimensions, weight, density and essentially no Boron-10 depletion or hydrogen loss when exposed to conservative testing conditions. Thus, since the Holtite-A did not show any material damage or change in the properties during the conservative test conditions specified in [3.3.4] and [3.3.5], the expected weight loss due to thermal aging over a 60-year timeframe is less than the weight loss of the samples used for irradiation testing, and the expected accumulated neutron fluence and gamma dose over a 60-year timeframe is less than the totals specified after irradiation testing, the Holtite-A in the HI-TRAC is suitable during long-term thermal and radiation exposures expected during usage over 60-year timeframe. HenceTherefore, no AMP or TLAA is required.

3.4 Time-Limited Aging Analyses (TLAA)

Using the TLAA-identification criteria discussed in Section 3.2.4.1, the CoC, SER, Technical Specifications were reviewed and the following TLAAs were identified for further evaluation and disposition:

1. Neutron Absorber Boron Depletion
2. HI-TRAC Trunnions
3. MPC Fatigue
4. Fuel Cladding Integrity HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-14

ATTACHMENT 1 TO HOLTEC LETTER 5014923 58 of 186 3.5 Aging Management Programs (AMP)

Based on the results of the aging management reviews for systems, structures, and components (SSC) previously determined to be within the scope of the license renewal, presented above, the following AMPs are required:

1. MPC AMP
2. Overpack AMP
3. HI-TRAC AMP
4. Fuel Assembly AMP
5. 100U Concrete AMP The full details of these AMPs are presented in Appendix A.

3.6 References

[3.0.1] NUREG-2214, Managing Aging Process in Storage (MAPS) Report, July 2019.

[3.1.1] HI-2188453 SMDR Evaluation Report

[3.1.2] HI-2188468, ECO Evaluation Report

[3.3.1] PNNL-14390, Dry Storage Demonstration for High-Burnup Spent Nuclear Fuel -

Feasibility Study, August 2003.

[3.3.2] ISG-11, Cladding Considerations for the Transportation and Storage of Spent Fuel, Revision 3, November 2003

[3.3.3] ISG-24, The Use of a Demonstration Program as a Surveillance Tool for Confirmation of Integrity for Continued Storage of High Burnup Fuel Beyond 20 Years, Revision 0, July 2014

[3.3.4] Holtec Report HI-2002420, Holtite-A: Results of Pre- and Post-Irradiation Tests and Measurements, Revision 1.

[3.3.5] Holtec Report HI-2002396, Holtite-A: Development History and Thermal Performance Data, Revision 5.

[3.3.6] Holtec Report HI-2210382, Shielding Analysis in Support of HI-STORM 100 License Renewal Application, Revision 0.

[3.3.7] Holtec Report HI-2002444, HI-STORM 100 FSAR, Rev 18, dated May 16, 2019 HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-15

ATTACHMENT 1 TO HOLTEC LETTER 5014923 59 of 186 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment 1 Requiring Management Function Mechanism Management Activity MPC Fatigue Helium Fatigue Cracking TLAA Pitting and Loss of Material MPC AMP Crevice Corrosion Confinement/

Stress Corrosion Shell Structural Alloy X Cracking MPC AMP Cracking Integrity Sheltered Loss of Fracture Not needed per Radiation Toughness [3.0.1]

MPC Fatigue Fatigue Cracking TLAA MPC Fatigue Helium Fatigue Cracking TLAA Pitting and Loss of Material MPC AMP Crevice Corrosion Confinement/

Stress Corrosion Baseplate Structural Alloy X Cracking MPC AMP Cracking Integrity Sheltered Loss of Fracture Not needed per Radiation Toughness [3.0.1]

MPC Fatigue Fatigue Cracking TLAA MPC Fatigue Helium Fatigue Cracking Lid Alloy X TLAA Confinement/ (one-piece Pitting and Loss of Material MPC AMP Structural design and top Crevice Corrosion Sheltered Integrity portion of Stress Corrosion Cracking MPC AMP optional two Cracking piece design) Loss of Fracture Not needed per Radiation Toughness [3.0.1]

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-16

ATTACHMENT 1 TO HOLTEC LETTER 5014923 60 of 186 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment 1 Requiring Management Function Mechanism Management Activity MPC Fatigue Fatigue Cracking TLAA None identified None identified Alloy X or Helium N/A per [3.0.1] per [3.0.1]

Carbon Steel Structural (bottom piece Lid (bottom piece)

Integrity of optional None identified None identified two piece Embedded N/A per [3.0.1] per [3.0.1]

design)

Pitting and Loss of Material MPC AMP Crevice Corrosion Microbiologically Not needed per Loss of Material influenced Closure Ring Confinement Alloy X Sheltered [3.0.1]

corrosion Stress Corrosion Cracking MPC AMP Cracking Loss of Fracture Not needed per Radiation Toughness [3.0.1]

Helium None Identified None Identified None Required per [3.0.1] per [3.0.1]

Port Cover Plates Confinement Alloy X Embedded Loss of Fracture Radiation Not needed per Toughness [3.0.1]

Basket Cell Spacer Structural None identified None identified Alloy X Helium None Required Block Integrity per [3.0.1] per [3.0.1]

Criticality None identified None identified Basket Center Column Alloy X Helium None Required Control per [3.0.1] per [3.0.1]

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-17

ATTACHMENT 1 TO HOLTEC LETTER 5014923 61 of 186 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment 1 Requiring Management Function Mechanism Management Activity Criticality Control, None identified None identified Basket Cell Plates Alloy X Helium None Required Structural per [3.0.1] per [3.0.1]

Integrity Criticality None identified None identified Flux Gap Cover Alloy X Helium None Required Control per [3.0.1] per [3.0.1]

Criticality None identified None identified Flux Gap Plate Alloy X Helium None Required Control per [3.0.1] per [3.0.1]

Criticality None identified None identified Basket Cover Angle Alloy X Helium None Required Control per [3.0.1] per [3.0.1]

Criticality Control, None identified None identified Basket Cell Angle Alloy X Helium None Required Structural per [3.0.1] per [3.0.1]

Integrity Criticality Control, None identified None identified Basket Cell Channel Alloy X Helium None Required Structural per [3.0.1] per [3.0.1]

Integrity Loss of material Radiation TLAA- Neutron properties Absorber Criticality Boral or Neutron Absorber Helium Depletion Control Metamic Evaluation Drain and Vent Shield None identified None identified Shielding Alloy X Helium None Required Block per [3.0.1] per [3.0.1]

SA 193B8 (or None identified None identified Plugs for Drilled Holes Shielding Embedded None Required equivalent) per [3.0.1] per [3.0.1]

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-18

ATTACHMENT 1 TO HOLTEC LETTER 5014923 62 of 186 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment 1 Requiring Management Function Mechanism Management Activity Microbiologically influenced Loss of Material corrosion / MPC AMPNone pPitting and Sheltered crevice corrosion Stress Corrosion MPC AMP Cracking Cracking Loss of Fracture Not needed per Radiation Toughness [3.0.1]

Pitting and crevice Loss of Material MPC AMP Lifting Hole Plug Structural corrosion Alloy X Sheltered (Optional) Integrity Stress Corrosion MPC AMP Cracking Cracking Heat Conduction None identified None identified Heat Transfer Aluminum Helium None Required Elements (Optional) per [3.0.1] per [3.0.1]

Upper Fuel Spacer Structural None identified None identified Alloy X Helium None Required Column Integrity per [3.0.1] per [3.0.1]

Structural None identified None identified Upper Fuel Spacer Pipe Alloy X Helium None Required Integrity per [3.0.1] per [3.0.1]

Structural None identified None identified Sheathing Alloy X Helium None Required Integrity per [3.0.1] per [3.0.1]

Structural None identified None identified Basket Shims Alloy X Helium None Required Integrity per [3.0.1] per [3.0.1]

Basket Supports (Angled Plates and Parallel Plates Structural None identified None identified Alloy X Helium None Required with connecting end Integrity per [3.0.1] per [3.0.1]

shims)

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-19

ATTACHMENT 1 TO HOLTEC LETTER 5014923 63 of 186 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment 1 Requiring Management Function Mechanism Management Activity Basket Supports (Angled Plates and Parallel Structural None identified None identified Alloy X Helium None Required Plates, if Basket Shims Integrity per [3.0.1] per [3.0.1]

are not used)

Basket Supports (Flat Structural None identified None identified Alloy X Helium None Required Plates) Integrity per [3.0.1] per [3.0.1]

Basket Supports (if Structural None identified None identified Alloy X Helium None Required Basket Shims are used) Integrity per [3.0.1] per [3.0.1]

Structural None identified None identified Basket Shims Alloy X Helium None Required Integrity per [3.0.1] per [3.0.1]

Structural A1932-B8 or None identified None identified Upper Fuel Spacer Bolt Helium None Required Integrity equivalent per [3.0.1] per [3.0.1]

Upper Fuel Spacer End Structural None identified None identified Alloy X Helium None Required Plate Integrity per [3.0.1] per [3.0.1]

Lower Fuel Spacer Structural Stainless Steel None identified None identified 2 Helium None Required Column Integrity per [3.0.1] per [3.0.1]

Lower Fuel Spacer End Structural None identified None identified Alloy X Helium None Required Plate Integrity per [3.0.1] per [3.0.1]

None identified None identified Vent and Drain Tube Retrievability Stainless Steel Helium None Required per [3.0.1] per [3.0.1]

None identified None identified Vent and Drain Cap Retrievability Stainless Steel Helium None Required per [3.0.1] per [3.0.1]

Vent Shield Block Structural None identified None identified Alloy X Helium None Required Spacer Integrity per [3.0.1] per [3.0.1]

Criticality Alloy X/ None identified None identified Damaged Fuel Container Helium None Required Control Aluminum per [3.0.1] per [3.0.1]

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-20

ATTACHMENT 1 TO HOLTEC LETTER 5014923 64 of 186 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment 1 Requiring Management Function Mechanism Management Activity Basket Sub-Panel (MPC- Criticality Loss of material Boron Depletion TLAA- Neutron 68M/32M) Control properties Absorber Metamic-HT Helium Depletion Evaluation Basket Shims (MPC- Heat Transfer None identified None identified Aluminum Helium None Required 68M/32M) per [3.0.1] per [3.0.1]

Solid Shims (MPC- Heat Transfer None identified None identified Aluminum Helium None Required 68M/32M) per [3.0.1] per [3.0.1]

Damaged Fuel Isolator Criticality None identified None identified Aluminum Helium None Required Control per [3.0.1] per [3.0.1]

Drain Line Guide Tube Retrievability None identified None identified Stainless Steel Helium None Required per [3.0.1] per [3.0.1]

Vent and Drain Tube, Retrievability None identified None identified Stainless Steel Helium None Required Optional per [3.0.1] per [3.0.1]

Threaded Disc, Plug Retrievability None identified None identified Stainless Steel Helium None Required Adjustment per [3.0.1] per [3.0.1]

Vent and Drain Plug Retrievability None identified None identified Aluminum Helium None Required per [3.0.1] per [3.0.1]

Thread Shield Cap Retrievability None identified None identified Aluminum Helium None Required per [3.0.1] per [3.0.1]

Retaining Ring Retrievability None identified None identified Stainless Steel Helium None Required per [3.0.1] per [3.0.1]

Notes:

1) Where more than one environment is listed the subcomponent is exposed to one environment on the inside and a second environment on the outside.
2) See FSAR [2.1.10] Table 2.2.6 HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-21

ATTACHMENT 1 TO HOLTEC LETTER 5014923 65 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Radial Shield Shielding Loss of Material Not needed per Concrete Embedded (steel) Radiation Properties [3.0.1]

Shield Block Ring & Shielding General Shell Corrosion /

Overpack Loss of Material Pitting and SA-516-70 or AMP Sheltered Crevice SA-515-70 Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Pedestal Shield Shielding Loss of Material Not needed per Concrete Sheltered Radiation Properties [3.0.1]

Lid Shield Shielding Loss of Material N/A, see Concrete Embedded Radiation Properties Section 3.4 Shield Shell Shielding ShelteredEmbedded Loss of Material Not needed per (for early versions SA-516-70 Radiation (concrete) Properties [3.0.1]

only)

Shield Block Shielding Loss of Material Not needed per Concrete Embedded Radiation Properties [3.0.1]

Gamma Shield Cross Shielding Pitting and Overpack Plates & Tabs Loss of Material Crevice AMP SA240-304 Sheltered Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Baseplate Structural General Overpack Integrity SA-516-70 Sheltered Loss of Material Corrosion /

AMP Pitting and HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-22

ATTACHMENT 1 TO HOLTEC LETTER 5014923 66 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Outer Shell Structural General Integrity Corrosion /

Overpack Loss of Material Pitting and AMP SA 516-70 Air-Outdoor Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Inner Shell Structural General Integrity Corrosion /

Overpack Loss of Material Pitting and AMP SA-516 Gr. 70 Sheltered Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Pedestal Shell Structural General Integrity Corrosion /

Overpack Loss of Material Pitting and AMP SA516-70 Sheltered Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Pedestal Baseplate Structural General SA-516-70 or Overpack Integrity Air-Outdoor Loss of Material Corrosion /

SA-515-70 AMP Pitting and HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-23

ATTACHMENT 1 TO HOLTEC LETTER 5014923 67 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Lid Bottom Plate Structural General Integrity Corrosion /

Overpack Loss of Material Pitting and AMP SA516-70 Sheltered Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Lid Shell Structural General Integrity Corrosion /

Overpack Loss of Material Pitting and Air-Outdoor AMP SA-516-70 Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Inlet Vent Vertical & Structural General Horizontal Plates Integrity Corrosion /

Overpack Loss of Material Pitting and Air-Outdoor AMP SA-516-70 Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Exit Vent Vertical & Structural General Air-Outdoor Overpack Horizontal Plates Integrity SA-516-70 Loss of Material Corrosion /

AMP Pitting and HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-24

ATTACHMENT 1 TO HOLTEC LETTER 5014923 68 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Top Plate Structural General Integrity Corrosion /

Overpack Loss of Material Pitting and AMP SA516-70 Sheltered Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Lid Top Plate Structural General Integrity Corrosion /

Overpack Loss of Material Pitting and AMP SA516-70 Sheltered Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Lid Shield Ring Structural General Integrity Corrosion /

Overpack Loss of Material Pitting and AMP SA516-70 Sheltered Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Lid Vent Side Plate Structural General Overpack Integrity SA516-70 Sheltered Loss of Material Corrosion /

AMP Pitting and HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-25

ATTACHMENT 1 TO HOLTEC LETTER 5014923 69 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Crevice Corrosion Loss of Material Not needed per Radiation Properties [3.0.1]

Lid Shield Block Shielding Loss of Material Not needed per Concrete Embedded Radiation Properties [3.0.1]

Radial Plate Structural Integrity SA516-70 Embedded None Identified None Identified N/A Lid Stud, Tee Handle Structural General Bolt & Nut Integrity SA-194 Corrosion /

Overpack SA -564-6340/ Sheltered Loss of Material Pitting and AMP SA193-B787 Crevice Corrosion Lid Stud Nut Structural General Integrity Corrosion /

Overpack SA194-2H Sheltered Loss of Material Pitting and AMP Crevice Corrosion Lid Stud Washer Structural None identified per None identified Stainless Steel Sheltered None Required Integrity [3.0.1] per [3.0.1]

Lid Washer Structural None identified per None identified SA 240-304 Sheltered None Required Integrity [3.0.1] per [3.0.1]

Bolt Anchor Block Structural SA 350 / SA 203 Embedded None Identified None Identified N/A Integrity Channel Structural SA 516-70 / SA Galvanic Overpack Sheltered Loss of Material Integrity 240 Corrosion AMP HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-26

ATTACHMENT 1 TO HOLTEC LETTER 5014923 70 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity General Corrosion /

Overpack Loss of Material Pitting and AMP Crevice Corrosion Pedestal Platform Structural General Integrity Corrosion /

Overpack A36 Sheltered Loss of Material Pitting and AMP Crevice Corrosion Shear Ring Structural General Integrity Corrosion /

Overpack SA 516-70 Sheltered Loss of Material Pitting and AMP Crevice Corrosion Channel Mounts Structural Galvanic Overpack Loss of Material Integrity Corrosion AMP General A36 Sheltered Corrosion/

Overpack Loss of Material Pitting and AMP Crevice Corrosion Radial Weld Plate Structural General Integrity Corrosion/

Overpack SA 516-70 Sheltered Loss of Material Pitting and AMP Crevice Corrosion HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-27

ATTACHMENT 1 TO HOLTEC LETTER 5014923 71 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Heat Shield Heat General Transfer Corrosion/

Overpack Carbon Steel Sheltered Loss of Material Pitting and AMP Crevice Corrosion Heat Shield Ring Heat General Transfer Corrosion/

Overpack Carbon Steel Sheltered Loss of Material Pitting and AMP Crevice Corrosion Lug Support Ring Structural General Integrity Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion Gusset Structural General Integrity Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion Stud with Nut Structural General Integrity Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion Bottom Plate Structural General Overpack Integrity Steel Sheltered Loss of Material Corrosion/

AMP Pitting and HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-28

ATTACHMENT 1 TO HOLTEC LETTER 5014923 72 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Crevice Corrosion Spacer Block Structural Pitting and Overpack Integrity Steel Sheltered Loss of Material Crevice AMP Corrosion 100S Version B Base Shielding General Shield Block Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion Top Plate Structural General Integrity Corrosion/

Overpack Steel Sheltered Loss of Material Pitting and AMP Crevice Corrosion MPC Support Structural General Integrity Corrosion/

Overpack Steel Sheltered Loss of Material Pitting and AMP Crevice Corrosion Shield Concrete Shielding Loss of Material Not needed per Concrete Embedded Radiation Properties [3.0.1]

Lid Outer Ring Structural General Integrity Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-29

ATTACHMENT 1 TO HOLTEC LETTER 5014923 73 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Lid Inner Ring Structural None Identified per None Identified Steel Embedded N/A Integrity [3.0.1] per [3.0.1]

Lid Lift Block Structural General Integrity Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion Lid Shield Concrete Shielding Loss of Material Not needed per Concrete Embedded Radiation Properties [3.0.1]

Lid Stud Structural General Integrity Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion Lid Closure Bolt Structural General Integrity Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion Lid Hex Nut Structural General Integrity Corrosion/

Overpack Steel Air-Outdoor Loss of Material Pitting and AMP Crevice Corrosion Cask Radial Gusset Structural None Identified per None Identified Steel Embedded N/A Integrity [3.0.1] per [3.0.1]

Radial Rib Structural None Identified per None Identified Steel Embedded N/A Integrity [3.0.1] per [3.0.1]

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-30

ATTACHMENT 1 TO HOLTEC LETTER 5014923 74 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Closure Lid Concrete Shielding Embedded None Identified per None Identified Concrete N/A

[3.0.1] per [3.0.1]

Closure Lid Steel Structural Sheltered General Integrity, Corrosion /

Overpack Shielding Loss of material Pitting and AMP Crevice corrosion Steel Air - Outdoor General Corrosion /

Overpack Loss of material Pitting and AMP Crevice corrosion Container Shell Structural Embedded None Identified Bottom Plate Integrity (Concrete) per None Identified per [3.0.1]General N/AOverpack Steel [3.0.1]Loss of Corrosion/

AMP Material Pitting and Crevice Corrosion Container Flange Structural Air - Outdoor General Integrity Corrosion /

Overpack Steel Loss of material Pitting and AMP Crevice corrosion Divider Shell and Heat Sheltered General Overpack Divider Shell Transfer Steel Loss of material Corrosion /

AMP Restraints Pitting and HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-31

ATTACHMENT 1 TO HOLTEC LETTER 5014923 75 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Crevice corrosion Upper and Lower Structural Sheltered General MPC Guides Integrity Corrosion /

Overpack Steel Loss of material Pitting and AMP Crevice corrosion MPC Bearing Pads Structural Sheltered Galvanic Overpack Loss of Material Integrity Corrosion AMP General Steel Corrosion /

Overpack Loss of material Pitting and AMP Crevice corrosion Insulation Heat Insulator Embedded (Steel) None identified None identified per N/ASee Transfer materialKaowool per

[3.0.1]Loss of Paragraph

( (ceramic fiber) [3.0.1]Radiation Material Properties 3.3.2.5 or equivalent) 100U Concrete Loss of material Erosion AMP Shielding, 100U Concrete Sub-grade Structural Soil Exposed Loss of form Settlement AMP Integrity Loss of material 100U Concrete Desiccation properties AMP HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-32

ATTACHMENT 1 TO HOLTEC LETTER 5014923 76 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Reinforced Concrete; Structural Cracking / Loss of Aggressive VVM Interface Pad, Integrity strength / loss of chemical attack 100U Concrete Top Surface Pad material / reduction AMP of concrete pH Cracking / Loss of Freeze and thaw 100U Concrete Material (spalling, AMP scaling)

Air - Outdoor Cracking / Loss of Reaction with 100U Concrete Strength aggregates AMP Salt scaling 100U Concrete Loss of Material AMP Concrete Loss of strength / Leaching of Increase in porosity calcium 100U Concrete and permeability / hydroxide AMP Reduction of concrete pH Cracking / Loss of Aggressive strength / loss of 100U Concrete Chemical material / Reduction AMP Attack of concrete pH Embedded (soil) Differential 100U Concrete Cracking Settlement AMP Cracking / Loss of Freeze and thaw 100U Concrete Material AMP HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-33

ATTACHMENT 1 TO HOLTEC LETTER 5014923 77 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Loss of strength / Microbiological Loss of material / degradation Increase in porosity 100U Concrete and permeability / AMP Reduction of concrete pH Cracking / Loss of Reaction with 100U Concrete strength aggregates AMP Salt Scaling 100U Concrete Loss of material AMP Loss of strength / Leaching of Increase in porosity calcium 100U Concrete and permeability / hydroxide AMP Reduction of concrete pH Retaining Wall, Structural Embedded (Soil) Cracking / Loss of Aggressive Support Foundation Integrity, strength / loss of Chemical 100U Concrete Pad Shielding material / reduction Attack AMP of concrete pH Differential 100U Concrete Cracking Settlement AMP Concrete Loss of Strength / Microbiological Loss of Material / degradation Increase in porosity 100U Concrete and permeability / AMP reduction of concrete pH HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-34

ATTACHMENT 1 TO HOLTEC LETTER 5014923 78 of 186 Table 3.3-2: Aging Management Review of HI-STORM 100 Overpack Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment1,2 Requiring Management Function Mechanism23 Management Activity Cracking / Loss of Reaction with 100U Concrete strength aggregates AMP Loss of strength / Leaching of Increase in porosity calcium 100U Concrete and permeability / hydroxide AMP reduction of concrete pH Lid Rib Structural Embedded None identified per None identified Steel N/A Integrity (Concrete) [3.0.1] per [3.0.1]

MPC Bottom Support Structural Sheltered General Guides Integrity Corrosion /

Overpack Steel Loss of material Pitting and AMP Crevice corrosion Notes:

1) The term embedded refers to the fact that the individual component is mechanically sealed and is not exposed to any environment.
2) The term general corrosion refers to loss of material due to corrosion, proceeding at approximately the same rate over a metal surface, also referred to as uniform corrosion.

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-35

ATTACHMENT 1 TO HOLTEC LETTER 5014923 79 of 186 Table 3.3-3: Aging Management Review of Fuel Assembly Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity Criticality Embrittlement Hydride Re-High Burnup Fuel Control, (High Burnup orientation (High AMP Radiation Fuel only) Burnup Fuel only)

Fuel Cladding Shielding, Zircaloy Helium Changes in Thermal Creep Confinement High Burnup Fuel dimensions (High (High Burnup Fuel Structural AMP Burnup Fuel only) only)

Integrity Criticality Control, None identified None identified Spacer Grid Assemblies Zircaloy Helium None Required Structural per [3.0.1] per [3.0.1]

Integrity Stainless Structural None identified None identified Upper End Fitting Steel Helium None Required Integrity per [3.0.1] per [3.0.1]

Inconel Stainless Structural None identified None identified Lower End Fitting Steel Helium None Required Integrity per [3.0.1] per [3.0.1]

Inconel Zircaloy /

Structural None identified None identified Guide Tubes Stainless Helium None Required Integrity per [3.0.1] per [3.0.1]

Steel HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-36

ATTACHMENT 1 TO HOLTEC LETTER 5014923 80 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity Radial Lead Shield Shielding ASTM B29 None Identified None Identified Embedded N/A Lead per [3.0.1] per [3.0.1]

Pool Lid Lead Shielding Shielding ASTM B29 None Identified None Identified Embedded N/A Lead per [3.0.1] per [3.0.1]

Top Lid Shielding Shielding Radiation See Paragraph Cracking Embrittlement 3.3.4.5 Loss of ductility See Paragraph Holtite A Embedded Thermal Aging and fracture 3.3.4.5 toughness See Paragraph Boron Depletion Loss of Shielding 3.3.4.5 Outer Shell Structural General/ Pitting Integrity Air- Outdoor Loss of Material and Crevice HI-TRAC AMP Corrosion None Identified Steel Embedded None Identified per [3.0.1]General N/AHI-TRAC (Lead / Water, per [3.0.1]Loss of Corrosion/ AMP when water Material Pitting and Crevice HI-TRAC AMP jacket filled)

Corrosion Inner Shell Structural Loss of Material Not needed per Embedded Radiation Integrity Properties [3.0.1]

Steel General Air Loss of Material HI-TRAC AMP Corrosion/ Pitting HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-37

ATTACHMENT 1 TO HOLTEC LETTER 5014923 81 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity and Crevice Corrosion Radial Ribs Structural None Identified None Identified Integrity Water (when per [3.0.1]General N/AHI-TRAC per [3.0.1]Loss of Steel water jacket Corrosion/ AMP Material filled) Pitting and Crevice Corrosion Enclosure Shell Panels Structural None Identified None Identified Integrity Water (when per [3.0.1]General HI-TRAC per [3.0.1]Loss of water jacket Corrosion/ AMPN/A Material filled) Pitting and Crevice Steel Corrosion General Corrosion/ Pitting Air Loss of Material HI-TRAC AMP and Crevice Corrosion Water Jacket End Plate Structural Water (when None Identified Integrity water jacket None Identified per [3.0.1]General HI-TRAC filled, may have per [3.0.1]Loss of Corrosion/

AMPN/A contained Material Pitting and Crevice Steel glycol) Corrosion General Corrosion/ Pitting Air Loss of Material HI-TRAC AMP and Crevice Corrosion Top Flange Structural General Steel Air Loss of Material HI-TRAC AMP Integrity Corrosion/ Pitting HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-38

ATTACHMENT 1 TO HOLTEC LETTER 5014923 82 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity and Crevice Corrosion Lower Water Jacket Structural None Identified None Identified Shell Integrity Water (when per [3.0.1]General HI-TRAC per [3.0.1]Loss of water jacket Corrosion/ AMPN/A Material filled) Pitting and Crevice Steel Corrosion General Corrosion/ Pitting Air Loss of Material HI-TRAC AMP and Crevice Corrosion Water Jacket Bottom Structural None Identified None Identified Ring Integrity Water (when per [3.0.1]General HI-TRAC per [3.0.1]Loss of water jacket Corrosion/ AMPN/A Material filled) Pitting and Crevice Steel Corrosion General Corrosion/ Pitting Air Loss of Material HI-TRAC AMP and Crevice Corrosion Water Jacket Top Plates Structural None Identified None Identified Integrity Water (when per [3.0.1]General HI-TRAC per [3.0.1]Loss of water jacket Corrosion/ AMPN/A Material Steel filled) Pitting and Crevice Corrosion General Air Loss of Material HI-TRAC AMP Corrosion/ Pitting HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-39

ATTACHMENT 1 TO HOLTEC LETTER 5014923 83 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity and Crevice Corrosion Bottom Flange Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Pool Lid Outer Ring Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Pool Lid Top Plate Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Top Lid Outer Ring Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Top Lid Inner Ring Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Top Lid Top Plate Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Top Lid Bottom Plate Structural General Steel Air Loss of Material HI-TRAC AMP Integrity Corrosion/ Pitting HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-40

ATTACHMENT 1 TO HOLTEC LETTER 5014923 84 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity and Crevice Corrosion Fill Port Caps Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Pool Lid Bolt Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Lifting Trunnion Block Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Lifting Trunnion Structural Nickel Integrity Alloy /

Air Loss of Material Wear HI-TRAC AMP Stainless Steel Pocket Trunnion Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Dowel Pins Structural Stainless None Identified None Identified Air None Required Integrity Steel per [3.0.1] per [3.0.1]

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-41

ATTACHMENT 1 TO HOLTEC LETTER 5014923 85 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity Water Jacket Bottom Structural None Identified None Identified Plate Integrity Water (when per [3.0.1]General N/AHI-TRAC per [3.0.1]Loss of water jacket Corrosion/ AMP Material filled) Pitting and Crevice Steel Corrosion General Corrosion/ Pitting Air Loss of Material HI-TRAC AMP and Crevice Corrosion Pool Lid Bottom Plate Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Top Lid Lifting Block Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Bottom Flange Gussets Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Top Lid Stud/Bolt Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Top Lid Nut/Washer Structural General Steel Air Loss of Material HI-TRAC AMP Integrity Corrosion/ Pitting HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-42

ATTACHMENT 1 TO HOLTEC LETTER 5014923 86 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity and Crevice Corrosion Transfer Lid Side Lead Shielding None Identified None Identified Lead Embedded None Required Shield per [3.0.1] per [3.0.1]

Transfer Lid Door Lead Shielding None Identified None Identified Lead Embedded None Required Shield per [3.0.1] per [3.0.1]

Transfer Lid Door Shielding HI-TRAC Holtite Shielding Radiation Material Cracking Embrittlement TLAASee Paragraph 3.3.4.5 HI-TRAC Holtite Loss of ductility Material Holtite A Embedded Thermal Aging and fracture TLAASee toughness Paragraph 3.3.4.5 HI-TRAC Holtite Material Boron Depletion Loss of Shielding TLAASee Paragraph 3.3.4.5 Transfer Lid Top Plate Structural General Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Bottom Structural General Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Structural General Steel Air Loss of Material HI-TRAC AMP Intermediate Plate Integrity Corrosion/ Pitting HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-43

ATTACHMENT 1 TO HOLTEC LETTER 5014923 87 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity and Crevice Corrosion Transfer Lid Lead Cover Structural General Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Lead Cover Structural General Side Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door Top Structural General Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door Structural General Middle Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door Structural General Bottom Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door Wheel Structural General Housing Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door Structural General Steel Air Loss of Material HI-TRAC AMP Interface Plate Integrity Corrosion/ Pitting HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-44

ATTACHMENT 1 TO HOLTEC LETTER 5014923 88 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity and Crevice Corrosion Transfer Lid Door Side Structural General Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Wheel Structural General Shaft Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Shaft Cover Structural General Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Housing Structural General Stiffener Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door Lock Structural General Bolt Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door End Structural General Plate Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Lifting Lug Structural General Steel Air Loss of Material HI-TRAC AMP and Pad Integrity Corrosion/ Pitting HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-45

ATTACHMENT 1 TO HOLTEC LETTER 5014923 89 of 186 Table 3.3-4: Aging Management Review of HI-TRAC Subcomponents Aging Effects Aging Intended Aging Subcomponent Material Environment Requiring Management Function Mechanism Management Activity and Crevice Corrosion Transfer Lid Wheel Structural General Track Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door Stop Structural General Block Integrity Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP and Crevice Corrosion Transfer Lid Door Stop General Block Bolt Structural Corrosion/ Pitting Steel Air Loss of Material HI-TRAC AMP Integrity and Crevice Corrosion Short Rib Structural None identified None identified Integrity, Heat Steel Embedded N/A per [3.0.1] per [3.0.1]

Transfer Extended Rib Structural None identified None identified Integrity, Heat Steel Embedded N/A per [3.0.1] per [3.0.1]

Transfer HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188877 Proposed Rev. 10A 3-46

ATTACHMENT 1 TO HOLTEC LETTER 5014923 90 of 186 CHAPTER 4: AGING MANAGEMENT TOLLGATES 4.0 Introduction NEI 14-03 [1.1.3] introduced the concept of tollgates to be included as part of an operations-based aging management program. The tollgate concept provides a structured way for licensees to pause and formally assess aggregated feedback at specific points in time during the period of extended storage.

Tollgates are established as requirements in the generic CoC renewed application, and implemented by ISFSI general licensees to evaluate aging management feedback and perform a safety assessment that confirms the safe storage of spent nuclear fuel. The impact of the aggregate feedback will be assessed by the site as it pertains to components at the sites ISFSI and actions taken as necessary, such as:

  • Adjustment of aging-related degradation monitoring and inspection programs in AMPs described in Appendix A (e.g. scope, frequency)
  • Modification of TLAAs described in Appendix B
  • Performance of mitigation activities Each tollgate assessment will address the following elements as applicable:
  • Summary of research findings, operating experience, monitoring data, and inspection results made available since last assessment
  • Aggregate impact of findings, including any trends
  • Consistency of data with the assumptions and inputs in the TLAAs
  • Effectiveness of AMPs
  • Corrective actions, including any changes to AMPs
  • Summary and conclusions Sites will have access to the ISFSI Aging Management INPO Database to facilitate the aggregation and dissemination of aging-related information for the completion of these tollgate assessments. Generic tollgates are shown in Table 4-1. Note that the implementation of these tollgates does not infer that general licensees will wait until one of these designated times to evaluate information. Sites will continue to follow existing processes for addressing emergent issues, including the use of the corrective action program on site. These tollgates are specific times where an aggregate of information will be evaluated as a whole.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 4-1

ATTACHMENT 1 TO HOLTEC LETTER 5014923 91 of 186 Table 4-1: Tollgate Assessments for General Licensees Tollgate Year Assessment 1 Year of first Evaluate information from the following sources (as available) and canister loading + perform a written assessment of the aggregate impact of the 25 years information, including but not limited to trends, corrective actions required, and the effectiveness of the AMPs with which they are associated:

  • Results, if any, of research and development programs focused specifically on aging-related degradation mechanisms identified as potentially affecting the storage system and ISFSI site. One example of such research and development would be EPRI Chloride-Induced Stress Corrosion Cracking (CISCC) research.
  • Relevant results of other domestic and international research, which may include non-nuclear research
  • Relevant domestic and international operating experience, which may include non-nuclear operating experience
  • Relevant results of domestic and international ISFSI and dry storage system performance monitoring Much of this information can be gathered from the Aging Management INPO Database (AMID).

2 Year of first Evaluate additional information gained from the sources listed in canister loading + Tollgate 1 along with any new relevant sources and perform a written 30 years assessment of the aggregate impact of the information. This evaluation should be informed by the results of Tollgate 1. The aging effects and mechanisms evaluated at this tollgate and the time at which it is conducted may be adjusted based on the results of the Tollgate 1 assessment.

3 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1 and 2 canister loading +

35 years 4 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, and 3 canister loading +

40 years 5 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, and canister loading + 4 45 years 6 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, canister loading + and 5 50 years 7 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, 5, canister loading + and 6 55 years 8 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, 5, canister loading + 6, and 7 60 years HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 4-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 92 of 186 APPENDIX A: HI-STORM 100 AGING MANAGEMENT PROGRAMS A.0 Introduction Section 3.5 identifies the following needed AMPs:

1. MPC AMP
2. Overpack AMP
3. HI-TRAC AMP
4. Fuel Assembly AMP
5. 100U Concrete AMP This appendix contains the 10 elements of the AMPs, following the guidance of NUREG-1927 Revision 1.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-1

ATTACHMENT 1 TO HOLTEC LETTER 5014923 93 of 186 MPC AMP Element Description

1. Scope of Program This program covers MPCs stored under the HI-STORM 100 CoC, and the subcomponents identified in Table 3.3-1.
2. Preventative This AMP uses condition monitoring to manage aging effects.

Actions Preventative actions to minimize corrosion and stress corrosion cracking were taken during fabrication. Namely, stainless steel material was used to provide corrosion resistance, and fabrication controls were in place at the time of manufacture. These preventative actions minimize the likelihood of aging effects, but do not replace the need for condition monitoring during the extended storage period.

Aging effects include loss of material due to localized corrosion, cracking due to fatigue and stress corrosion cracking, loss of material properties due to radiation and loss of strength due to thermal aging.

No new preventative actions are included in this AMP.

3. Parameters The MPC AMP uses inspections as described below to look for visual Monitored / evidence of discontinuities and imperfections, such as localized Inspected corrosion, including pitting and crevice corrosion, and stress corrosion cracking of the accessible canister welds and weld heat affected zones.

The inspections also look for the appearance and location of deposits on the canister surfaces.

Inspections should also be performed on consider areas of canister to whichwhere it is known that temporary supports or attachments were attached by welding and subsequently removed (based on available fabrication records).

4. Detection of Aging Visual Examination Effects A visual inspection of the MPC surface shall be performed using a boroscope (or equivalent). The boroscope (or equivalent) inspection shall look at the accessible areas of the MPC surface, while the MPC remains in the overpack with the overpack lid installed. This visual inspection shall meet the requirements of a VT-3 Examination, as given in the ASME Boiler & Pressure Vessel Code (B&PVC)Section XI, Article IWA-2200, to the extent practical. Pitting and crevice corrosion that is open to the surface can potentially be detected by visual examination.Visual examination procedures shallshould follow ASME Code Section XI, Article IWA-2200 for VT-1 and VT-3 examinations.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 94 of 186 Additional assessment is necessary for suspected areas of localized corrosion and stress corrosion cracking. In these cases, the severity of the degradation shall be assessed, including the dimensions of the affected area and the depth of penetration with respect to the thickness of the canister. For accessible areas, remote visual examination meeting the requirements for ASME Code Section XI, IWA-2211 may be used to determine the type of degradation present (e.g., pitting corrosion or stress corrosion cracking). and the location of he ability to detect cracks on clean metal surfaces using visual inspection methods can be difficult for tight opening displacements.

Volumetric Examination Volumetric and surface examination methods are consistent with ASME Code XI, IWB-2500 shall be done to characterize the extent and severity of localized corrosion and stress corrosion cracking.

Volumetric examination of pits and areas immediately adjacent to pits shall be done when pits are located within 25 mm (1 inch) of a through thickness weld or within 25 mm (1 inch) of an area where a temporary attachment was known to be located.

The inspection shall be site-specific and performed on a minimum of one canister at each site that uses the HI-STORM 100 System. Note that if a site has more than one type of canister (for example, MPC-68 and MPC-68Ms), only one canister needs to be inspectedthe population should be treated as a whole. The selection criteria for choosing the canister/s to inspect and the determination of population size of canisters to inspect should consider the following:

  • EPRI Susceptibility Criteria (Technical Report 3002005371)
  • ASME Code Case N-860 Population Size Criteria Preference should be given to the canisters with the greatest susceptibility for localized corrosion or chloride-induced SCC due to accumulation and deliquescence of deposited salts on the MPC surface.
  • Canister Age
  • Canister with Lowest Heat Load
  • Canister with specific previously identified manufacturing deviation Alternatively, a site may choose to take credit for an inspection done at a different site, as long as the inspection can be shown to have been performed on a reasonably comparable or bounding canister based on the same criteria listed above.

Inspection Frequency HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-3

ATTACHMENT 1 TO HOLTEC LETTER 5014923 95 of 186 The inspection shall be performed by a qualified individual on one canister at a site at a frequency of 5 years (+/- 1.25 years). The first inspection shallould occur prior to entering the period of extended operationwithin 365 days of the 20th anniversary of initial overpack loading at the site or no laterwithin 365 days of the issuance of the renewed license, whichever is later. It is recommended that the same canister be used for each inspection to allow for the best continued monitoring and trending. The inspection population shall be re-evaluated after each inspection per ASME Code Case N-860 to examine any visual anomalies including any surface discontinuities, corrosion, flaws and other loose or damaged components. If any visual anomalies are identified in the inspection an assessment inspection shall be done per Code Case N-860.

It is recommended that sites schedule the MPC inspection concurrently with the Overpack Interior Inspection for ALARA purposes.

At the discretion of the inspector, the inspection of selected areas on the MPC may be upgraded to the VT-1 standard, as described in ASME Section XI, Article IWA-2200, to the extent practical.

5. Monitoring and The documented inspection results shallould provide the ability to Trending monitor and trend the appearance of the canister, it is recommended that the inspection video / photos be retained for comparison in subsequent examinations. Changes to the size and location of any areas of discoloration, localized corrosion, and/or stress corrosion cracking should be identified and documented for subsequent inspections.
6. Acceptance Inspection Results Requiring No Further Evaluation Criteria No indication of localized corrosion pits, etching, stress corrosion cracking, red-orange colored corrosion products in the vicinity of canister welds, closure welds and welds associated with temporary attachments during canister fabrication. Corrosion such as pitting requires additional evaluation. Minor surface corrosion (not pitting) is acceptable.

Inspection Results Requiring Additional Evaluation Indications of interest in locations on the MPC susceptible to SCC-which include areas adjacent to fabrication welds, closure welds, locations where temporary attachments may have been welded to and subsequently removed from the MPC, and the weld affected zones HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-4

ATTACHMENT 1 TO HOLTEC LETTER 5014923 96 of 186 that are subject to additional examination and disposition through the corrective action program include:

  • Discrete red-orange colored corrosion products especially those adjacent to fabrication welds, closure welds, locations where temporary attachments may have been welded to and subsequently removed from the MPC and the weld heat affected zones of these areas
  • Linear appearance of any color of corrosion products of any size parallel to or traversing fabrication welds, closure welds, and the weld heat affected zones of these areas.
  • Red-orange colored corrosion products greater than 1 mm in diameter combined with deposit accumulations in any location of the stainless steel canister
  • Red-orange colored corrosion tubercles of any size Alternatively, a general licensee may use acceptance criteria in an ASME Code for canister inspections that has been endorsed by the NRC.

If indications of localized or general corrosion, or stress corrosion cracking requiring additional evaluation are found, issue would be entered into the sites corrective action program and an engineering evaluation would be performed to determine the extent and impact of the corrosion on the components ability to perform its intended function. These evaluations may include additional visual, surface, or volumetric non-destructive examination methods to determine the loss of material. If the degradation does not compromise the ability of the MPC to maintain its function, then no further evaluation is required, but the degradation should be tracked for future inspections.

7. Corrective Actions The corrective actions performed based on any detected aging effects are in accordance with the sites Quality Assurance (QA) program.

The QA Program ensures that corrective actions are completed.

The QA program and corrective action program will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable, as applicable.

The corrective actions will also identify any actions needed to be taken for increased sample size, scope, or frequency of inspections as necessary, based on any detected aging effects. ASME Code Case N-860 can be used for guidance on these corrective actions.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-5

ATTACHMENT 1 TO HOLTEC LETTER 5014923 97 of 186 The corrective action program will also identify any dispositions needed from Holtec.

8. Confirmation The confirmation process will be commensurate with the site QA Process program. The QA program ensures that inspections, evaluations, and corrective actions are completed and extent of condition is considered.
9. Administrative The site QA program and implementing procedures for this AMP will Controls address instrument calibration and maintenance, inspector requirements, record retention requirements, and document control.

This AMP will be updated, as necessary, based on the toll gate assessments described in Section 4 of this application. Inspection results will be documented and made available for NRC inspection as necessary.

10. Operating Previous Operating Experience Experience No cases of chloride induced stress corrosion cracking for stainless steel dry storage canisters have been reported. Inspections of dry storage canisters after 20 years in service have been conducted at a few ISFSI sites [C.1.1 and C.1.2]. No evidence of localized corrosion was identified but some amount of chloride-containing salts were determined to be present and corrosion products believed to be related to iron contamination were identified.

Section 3.1.2 of this application summarizes HI-STORM 100 MPC operating experience, which indicates very minimal corrosion detected to date.

Future Operating Experience As the MPC inspections are performed, sites will upload information into the INPO AMID database to be shared with other users.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-6

ATTACHMENT 1 TO HOLTEC LETTER 5014923 98 of 186 Overpack AMP Element Description

1. Scope of Program This program covers the subcomponents of the HI-STORM 100 and HI-STORM 100U Overpacks identified in Table 3.3-2, which require the Overpack AMP to ensure their continued operation into the extended storage period. The AMP has two main parts: one for the internal areas and one for the external areas of the cask.
2. Preventative This AMP uses condition monitoring to manage aging effects. The Actions design of the system is intended to minimize aging effects, but this AMP focuses on condition monitoring and detecting any evidence of degradation. No new preventative actions are included in this AMP.
3. Parameters The inspections shall be site-specific and performed at sites which Monitored / utilize HI-STORM 100 systems. Visual inspections cover 100 Inspected percentall of normally accessible surfaces of the overpack including the external and internal surfaces.

Overpack External Normally accessible portions of tThe overpack with exposed surfaces are visually examined for indication of any surface deterioration.

Degradation could affect the ability of the overpack to provide support to the MPCs, to provide radiation shielding, to provide missile shielding, or to provide a path for heat transfer. The items inspected should cover (but are not limited to) those listed below:

  • Lid studs and nuts or lid closure bolts, as accessible
  • The accessible overpack body and lid painted surfaces
  • Vents
  • Anchor hardware, if used Overpack Internal The Normally accessible internal surfaces of the overpack are inspected for indications of corrosion and coating degradation. These indications may impact the long term ability of the cask to meet its intended function.
4. Detection of Aging Overpack External Effects The overpack external AMP is a visual inspection in order to detect any aging effects. The visual survey performed on all overpacks annually will identify the source of any staining or corrosion-related activity and the degree of damage. The visual survey is performed in accordance with site implementing procedures, and may be satisfied by continuing the overpack external surface (accessible) visual HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-7

ATTACHMENT 1 TO HOLTEC LETTER 5014923 99 of 186 examination in the HI-STORM FSAR Table 9.2.1. The ISFSI pad concrete portions adjacent to overpack shall be inspected visually for any evidencesigns of dedegradation (such as staining or rust) to determine if normally inaccessible components located in the overpack internal (i.e., container shell bottom overpack baseplate, cask bottom) need additional inspectionterioration.

Overpack Internal A visual inspection of the overpack annular space and the interior areas of the vents shall be performed using a boroscope (or equivalent). This visual inspection shall meet the requirements of a VT-3 Examination, as given in the ASME Boiler & Pressure Vessel Code (B&PVC)Section XI, Article IWA-2200, to the extent practical.

The internal inspection shall be performed on one overpack at each site at a frequency of 5 years (+/- 1.25 years). The first inspection shallould occur within 365 days of the 20th anniversary of initial overpack loading at the siteprior to entering the period of extended operation or no later thanwithin 365 days of the issuance of the renewed license, whichever is later. For ALARA reasons, it is recommended that the site use the overpack that contains the MPC used for the MPC AMP.

Alternatively, a site may choose to take credit for an internal inspection done at a different site, as long as the inspection can be shown to have been performed on a reasonably comparable or bounding canister based on the same criteria listed above.

The inspection shall be documented, including a detailed description of the surface condition and location of areas showing surface degradation.

5. Monitoring and The inspections and surveillances described for both the internal and Trending external subcomponents of the overpack are performed periodically in order to identify areas of degradation. The results will be evaluated by a qualified individual, and areas of degradation not meeting established criteria will be entered into the corrective action program for resolution or more detailed evaluation. The results will be compared against previous inspections in order to monitor and trend the progression of the aging effects over time.
6. Acceptance Overpack External Criteria The external metallic surfaces of the overpack are coated, and significant corrosion is not anticipated. Minor surface corrosion of the HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-8

ATTACHMENT 1 TO HOLTEC LETTER 5014923 100 of 186 carbon steel surface is possible and does not require further evaluation. Corrosion such as pitting requires additional evaluation.

Minor rust spots or indications of degraded coatings do not require further evaluation since they do not compromise the ability of the overpack to maintain its function, but should be identified for trending purposes. Vents shall be free from obstructions. Overpack lid shall be relatively free of dents, scratches, gouges or other damage. Gouges and depressions that are less than 25% of the thickness, less than 20%

of the largest lineal dimension of the part lengthong, less than 1/4 inch width, with a minimum separation between gouges of 5% of the largest lineal dimension of the part are considered acceptable without further evaluation. Gouges of this size were considered acceptable without further evaluation during fabrication, and continue to be acceptable during storage.

The area of ISFSI pad concrete adjacent to the overpack shall not show any evidence of corrosion such as rust.

Any indications of general or localized corrosion (pitting and crevice) on the steel surfaces, or degradation of coatings shall be identified for trending purposes. If indications requiring additional evaluation are found, issue would be entered into the sites corrective action program and an engineering evaluation would be performed to determine the extent and impact of the degradation on the components ability to perform its intended function. These evaluations may include additional visual, surface, or volumetric non-destructive examination methods to determine the loss of material. If the degradation does not compromise the ability of the overpacks ability to maintain its function, then no further evaluation is required but the degradation should be tracked for future inspections.

Overpack Internal The internal metallic surfaces of the overpack are coated, and significant corrosion is not anticipated. Minor surface corrosion of the carbon steel surface is possible and does not require further evaluation. Corrosion such as pitting requires additional evaluation.

Minor rust spots or indications of degraded coatings do not require further evaluation since they do not compromise the ability of the overpack to maintain its function, but should be identified for trending purposes.

Any indications of general or localized corrosion (pitting and crevice) on the steel surfaces, or degradation of coatings shall be identified for trending purposes. If indications requiring additional evaluation are found, issue would be entered into the sites corrective action program and an engineering evaluation would be performed to determine the extent and impact of the degradationcorrosion on the components HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-9

ATTACHMENT 1 TO HOLTEC LETTER 5014923 101 of 186 ability to perform its intended function. These evaluations may include additional visual, surface, or volumetric non-destructive examination methods to determine the loss of material. If the degradation does not compromise the ability of the overpacks ability to maintain its function, then no further evaluation is required but the degradation should be tracked for future inspections.

7. Corrective Actions The corrective actions performed based on any detected aging effects are in accordance with the sites Quality Assurance (QA) program.

The QA Program ensures that corrective actions are completed.

The QA program and corrective action program will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable, as applicable.

The corrective actions will also identify any actions needed to be taken for increased scope or frequency of inspections as necessary, based on any detected aging effects.

The corrective action program will also identify any dispositions needed from Holtec. One potential corrective actions, iIf significant exterior corrosion is found in the area, one potential corrective action could be to perform additional inspections of inaccessible surfaces, such as bottom of the cask.

8. Confirmation The confirmation process will be commensurate with the site QA Process program. The QA program ensures that inspections, evaluations, and corrective actions are completed.
9. Administrative The site QA program and implementing procedures for this AMP will Controls address instrument calibration and maintenance, inspector requirements, record retention requirements, and document control.

This AMP will be updated, as necessary, based on the toll gate assessments described in Section 4 of this application. Inspection results will be documented and made available for NRC inspection as necessary.

10. Operating Previous Operating Experience Experience Section 3.1.2 of this application summarizes HI-STORM 100 operating experience, which indicates very minimal corrosion detected to date, mostly limited to small rust spots and coating degradation.

That operating experience has been incorporated into the guidance on inspections and acceptance criteria contained in this AMP.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-10

ATTACHMENT 1 TO HOLTEC LETTER 5014923 102 of 186 Future Operating Experience As the overpack inspections are performed, sites will upload information into the INPO AMID database to be shared with other users.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-11

ATTACHMENT 1 TO HOLTEC LETTER 5014923 103 of 186 Transfer Cask AMP Element Description

1. Scope of Program The program covers the subcomponents of the Transfer Cask identified in Table 3.3-5 which require the Transfer Casks AMP, to operate into the extended storage period.
2. Preventative The Transfer Cask AMP utilizes inspections to ensure that the Actions equipment maintains its intended function through the extended storage period. The design and materials of construction of the Transfer Cask were implemented to minimize aging effects, but no new preventative actions are included as part of this AMP.
3. Parameters This program monitors the condition of internal and external steel Monitored / surfaces of all the transfer casks to identify general, pitting, crevice, Inspected and galvanic corrosion, and wear. The parameter inspected by the Transfer Cask AMP is visual evidence of degradation of external surfaces of the Transfer Cask and trunnions. The condition of inaccessible steel internal surfaces that are continuously or intermittently exposed to a liquid neutron shield are monitored from the external side of the shield shell. Fatigue analysis for the trunnions is provided in Appendix B of this renewal application.

Parameter monitored or inspected for accessible surfaces include:

  • Visual evidence of surface discontinuities and imperfections indicative of corrosion
  • Visual evidence of coating degradation (e.g., blisters, cracking, flaking, delamination) indicative of corrosion of the base metal.

Parameters monitored or inspected to evaluate inaccessible steel surfaces exposed to a liquid neutron shield include:

  • Visual evidence of leakage on external surfaces
4. Detection of Aging The Transfer Cask AMP manages loss of material due to corrosion Effects and wear, predominately for coated steel components.

The below lists provides the areas to be covered by the visual inspection, Visual inspections of the normally accessible surfaces are performed in accordance with the ASME Code Section XI, Article IWA-2213, for VT-3 examinations. The inspections shall cover 100 percentall of the normally accessible surfaces, including the cask exterior surfaces, cask interior cavity, lid surfaces, and the cask HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-12

ATTACHMENT 1 TO HOLTEC LETTER 5014923 104 of 186 bottom (during lifting or down ending). which will be implemented via detailed inspection procedures.

  • Painted surfaces
  • Lid surfaces
  • Lifting trunnions
  • Water jacket
  • Other accessible surfaces For normally inaccessible internal surfaces (i.e., liquid neutron shield),

the condition of the neutron shield shell surfaces shall be monitored by inspections for leakage when the shield is filled with water, following ASME Code Section XI, Article IWA-2212, VT-2 (visual) inspection requirements.

The inspection shall be performed prior to use of any Transfer Cask that has been in service longer than 20 years (or prior to the first use after the renewed license is issued, whichever is later) and at a minimum once a year while in use. Because the Transfer Cask is not used while loadings and unloadings are not occurring, pre-use inspections are most appropriate for the Transfer Cask. Periodic inspections when the Transfer Cask is not in use are not needed.

5. Monitoring and Visual inspections will determine the existence of loss of material on Trending the external surfaces of the Transfer Cask, and observations regarding the material condition are recorded in accordance with inspection procedures and are corrected or evaluated as satisfactory before use of the Transfer Cask.

Evaluation of this information during the preparations for MPC transfers provides adequate predictability and allows for corrective actions if necessary, prior to the need for the intended function of the component to be performed.

6. Acceptance The Transfer Cask AMP consists of visual inspections as described Criteria above.

The following results do not require further evaluation

  • All painted surfaces shall be free of degradation and chipped, cracked, or blistered paint
  • All lid surfaces shall be relatively free of dents, scratches, gouges, or other damage. Gouges and depressions that are less than 25% of the thickness, less than 20% of the largest lineal dimension of the part lengthong, less than 1/4 inch width, with a minimum separation between gouges of 5% of the largest lineal dimension of the part are considered acceptable without HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-13

ATTACHMENT 1 TO HOLTEC LETTER 5014923 105 of 186 further evaluation. Gouges of this size were considered acceptable without further evaluation during fabrication, and continue to be acceptable during extended operation.

  • Lifting trunnions shall be free of deformation, cracks, damage, wear, general and localized corrosion, and resistant toexcessive galling
  • The water jacket shall be free of leaks
  • All other accessible surfaces shall be free of dents, scratches, gouges, or other damage If evidence of corrosion, wear or coating degradation are identified, then the severity of degradation of the base metal shall be determined using site-specific procedures degradation of material beyond the above is detected on any of the identified subcomponents within the Transfer Cask, and the issue shallwould be entered into the sites corrective action program and an engineering evaluation shallwould be performed to determine the extent and impact of the corrosion or wear on the Transfer Casks ability to perform its intended function.

These additional evaluations may include additional visual, surface, or volumetric non-destructive examination methods to determine the loss of material.

For inaccessible internal surfaces, the acceptance criteria are no evidence of leakage of the water neutron shield.

7. Corrective Actions If the engineering evaluation described above shows that the Transfer Cask has indications that exceed acceptable limits for the Transfer Cask to perform its intended function, the issue will be entered into the corrective action process. This process may result in supplemental inspections such as non-destructive examinations (NDE) being performed.

The corrective action program will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable, as applicable.

The corrective actions will also identify actions needed for increased scope or frequency of inspections, as necessary, based on any detected aging effects.

8. Confirmation The confirmation process will be commensurate with the site QA Process program. The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the program.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-14

ATTACHMENT 1 TO HOLTEC LETTER 5014923 106 of 186

9. Administrative The QA program and implementing procedures for this AMP will Controls address instrument calibration and maintenance, inspector requirements, record retention requirements, and document control.

This AMP will be updated, as necessary, based on the toll gate assessments described in Section 4 of this application. Inspection results will be documented and made available for NRC inspection as necessary.

10. Operating Previous Operating Experience Experience Section 3.1.2 of this application summarizes HI-STORM 100 operating experience, which indicates very minimal corrosion detected to date, mostly limited to coating degradation. That operating experience has been incorporated into the guidance on inspections and acceptance criteria contained in this AMP.

Future Operating Experience As the transfer cask inspections are performed, sites will upload information into the INPO AMID database to be shared with other users HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-15

ATTACHMENT 1 TO HOLTEC LETTER 5014923 107 of 186 High Burnup Fuel Assembly AMP Element Description

1. Scope of Program The scope of the program covers the components identified in Table 3.3-4 which require the High Burnup Fuel Assembly AMP, to operate into the extended storage period.

This program is not applicable at sites that do not have high burnup fuel stored.

Fuel stored in the HI-STORM 100 MPCs is limited to a burnup of 68,200 MWD/MTU (PWR) and 65,000 MWD/MTU (BWR). The cladding materials for the high burnup fuel are zirconium based and the fuel is stored in a dry helium environment.

The program relies on the joint EPRI and DOE High Burnup Dry Storage Cask Research and Development Project (HDRP) conducted in accordance with the guidance in Appendix D of NUREG-1927, Rev 1, as a surrogate demonstration program that monitors the performance of high burnup fuel in dry storage.

The HDRP is a program designed to collect data from an SNF storage system containing high burnup fuel in a dry helium environment. The program entails loading and storing a bolted lid cask (the Research Project Cask), with intact high burnup fuel of nominal burnups between 53 GWd/MTU and 58 GWD/MTU. The fuel to be used in the program includes four kinds of zirconium based cladding. The Research Project Cask is to be licensed to the temperature limits contained in ISG-11 Rev 3, and is loaded to reach temperatures as close to the limit as practicable.

The parameters of the surrogate demonstration program are applicable to the HI-STORM 100 high burnup fuel, since the system burnup limits are approximately those being tested, the cladding is of the same type as those being tested, and the temperature limits of the fuel are the same as those being tested.

2. Preventative During the initial loading operations of the HI-STORM 100 system, Actions the technical specifications require that the fuel be stored in a dry, inert environment. These requirements ensure that the high burnup fuel is stored in an inert environment, preventing cladding degradation due to oxidation mechanisms. The canisters are also loaded in accordance with the temperature criteria of ISG-11, which minimizes HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-16

ATTACHMENT 1 TO HOLTEC LETTER 5014923 108 of 186 the impacts of degradation mechanisms on the fuel. There are no additional specific preventative actions included as part of the AMP.

3. Parameters The surrogate demonstration program monitors and inspects fuel Monitored / parameters as described in the HDRP.

Inspected

4. Detection of Aging The surrogate demonstration program detects aging effects as Effects described in the HDRP.
5. Monitoring and As information / data from the HDRP become available, the site will Trending monitor, evaluate, and trend the information via its operating experience program and /or corrective action program to determine what actions should be taken.

The site will evaluate the information / data from the HDRP to determine whether the acceptance criteria in Element 6 of this AMP are met.

  • If all of the acceptance criteria are met, no further assessment is needed.
  • If any of the acceptance criteria are not met, the licensee must conduct additional assessments and implement appropriate corrective actions (see Element 7 of this AMP).

Note that the site may use evaluations/assessments provided by Holtec to determine whether the acceptance criteria are met.

Formal evaluations of the aggregate information from the HDRP, available operating experience, NRC-generated communications, and other information will be performed at specific points as described in Chapter 4 of this application.

6. Acceptance The HDRP acceptance criteria are:

Criteria

  • Hydrogen content - Maximum hydrogen content of the cover gas over the approved storage period should be extrapolated from the gas measurements to be less than the design-bases limit for hydrogen content
  • Moisture content - Tthe moisture content in the canister (accounting for measurement uncertainty) should be determined to be acceptableless than the expected upper-moisture content per the design-bases drying process (with appropriate consideration for the differences in design/acceptance criteria between the demo cask and the HI-STORM 100). The drying criteria for the MPC is provided in Table 2.0.1 and Section 8.1 of HI-STORM 100 FSAR.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-17

ATTACHMENT 1 TO HOLTEC LETTER 5014923 109 of 186

  • Fuel condition / performance - nondestructive and destructive examinations should confirm the design-bases fuel condition (i.e., no changes to the analyzed fuel configuration considered in the safety analyses of the approved design bases Note that because the cask design to be used in the HDRP is different from the HI-STORM 100, the acceptance criteria will be based on the Research Cask design bases. If the fuel in the Research Cask meets the applicable design bases, the fuel in the HI-STORM 100 should also meet its design bases, as described in Element 1.
7. Corrective Actions If the acceptance criteria described above are not met, the issue will be entered into the corrective action process.

The corrective action program will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable, as applicable.

The corrective actions will also identify actions needed for increased scope or frequency of inspections, as necessary, based on any detected aging effects.

8. Confirmation The confirmation process will be commensurate with the site QA Process program. The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the program.
9. Administrative The QA program and implementing procedures for this AMP will Controls address record retention requirements and document control.

This AMP will be updated, as necessary, based on the toll gate assessments described in Section 4 of this application. Inspection results will be documented and made available for NRC inspection as necessary.

10. Operating Future Operating Experience Experience As the HDRP continues information will be uploaded into the INPO AMID database HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-18

ATTACHMENT 1 TO HOLTEC LETTER 5014923 110 of 186 100U Concrete AMP Element Description

1. Scope of The program covers the 100U concrete identified in Table 3.3-2 which Program require the 100U Concrete AMP. The scope covers inspections of the above-grade areas of the ISFSI pad which are readily accessible and monitoring for the below grade portions exposed to sub grade (soil),

backfill, or groundwater per the requirements described in ACI 349.3R-

02. Groundwater chemistry program is utilized to identify conditions conducive to aging of below-grade portions. Radiation surveys shall be done to monitor the shielding performance of the HI-STORM 100U system.
2. Preventive This AMP uses condition monitoring to manage aging effects. The Actions design of the system is intended to minimize aging effects, but this AMP focuses on condition monitoring. No new preventive actions are included in this AMP.
3. Parameters The accessible and exposed surfaces are visually examined for indication Monitored / of surface deterioration. Degradation could affect the ability of the Inspected concrete to provide support to the VVMs, to provide radiation shielding, to provide missile shielding, or to provide a path for heat transfer. The inlet and outlet vents are monitored by visual inspection to ensure they are not obstructed.

Below-grade concrete portions exposed to soil environments are monitored in accordance with ACI 349.3R-02.

For inaccessible areas, groundwater monitoring is performed every 5 years for evidence of concrete to determine if any degradation from the inaccessible portions is occurring. The external soil/groundwater environment in contact with the concrete may possess and develop aging mechanisms that can expose the concrete to an environment that could precipitate the aging mechanisms listed in Table 3.3.2. To help monitor the condition of below-grade concrete by sampling its surrounding environment, a groundwater chemistry program to include groundwater chemistry sampling shall be performed every 5 years. This groundwater chemistry examination shall be used to characterize environmental exposure conditions and their potential effects to evaluate their propensity to cause concrete degradation. The groundwater chemistry program is utilized to identify conditions conducive to the following below-grade aging mechanisms:

  • Corrosion of embedded steel
  • Chemical attack (chloride and sulfate-induced degradation)

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-19

ATTACHMENT 1 TO HOLTEC LETTER 5014923 111 of 186 Any surface geometries that may support water ponding may potentially increase the rate of degradation. For groundwater chemistry program, the parameters monitored or inspected include:

  • pH of water
  • Concentration of chlorides and sulfates in the water For radiation surveys, the parameters monitored include the gamma dose rate and neutron fluence.
4. Detection of The AMP is a visual inspection of readily accessible surfaces of the Aging Effects ISFSI pad in order to detect any aging effects. These visual inspections cover 100 percentall of the readily accessible surfaces of the ISFSI pad and are conducted every 5 years. The visual survey will identify the source of any staining or corrosion-related activity and the degree of damage. This visual inspection identifies the current condition of the structure and can identify the extent and cause of any aging effect noted.

This visual inspection is conducted every 5 yearsannually by an individual meeting the qualification requirements of per ACI-349.3R-02, and includes all accessible areas on the pad. Settlement of the pad will be confirmed to be within the design basis using methodology from ACI 349.3R-02. Visual inspections of the below-grade areas are performed on an opportunistic basis, only when excavations in the area occur.

Groundwater chemistry monitoring shall be performed every 5 years to detect any potential corrosive environment that might cause concrete degradation. will determine if any degradation of the system from inaccessible areas is occurring. Radiation surveys shall be done every five years to monitor the dose rates of HI-STORM 100U system.

Data from all inspection and monitoring activities, including evidence of degradation and its extent and location, shall be documented on a checklist or inspection form. The results for the inspection will be documented, including descriptions of observed aging effects and supporting sketches, photographs or video.

5. Monitoring and Monitoring and trending methods are commensurate with consensus Trending defect evaluation guides and standards. These may include standards such as ACI 201.1R, ACI 207.3R, ACI 364.1R, ACI 562, or ACI 224.1R, as applicable. The inspections and surveillances described for reinforced concrete are performed periodically in order to identify areas of degradation. The results will be evaluated by a qualified individual, and areas of degradation not meeting established criteria will be entered into the sites CAP for resolution or more detailed evaluation. The results from both the visual inspection, radiation survey and groundwater HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-20

ATTACHMENT 1 TO HOLTEC LETTER 5014923 112 of 186 monitoring will be compared against previous inspections in order to monitor and trend the progression of the aging effects over time.

6. Acceptance American Concrete Institute Standard 349.3R-02 includes quantitative Criteria three-tier acceptance criteria for visual inspections of concrete surfaces, namely (1) acceptance without further evaluation, (2) acceptance after review, and (3) acceptance requiring further evaluation. Acceptable signifies that a component is free of significant deficiencies or degradation that could lead to the loss of structural integrity. Acceptable after review signifies that a component contains deficiencies or degradation but will remain able to perform its design basis function until the next inspection or repair. Acceptance requiring further evaluation signifies that a component contains deficiencies or degradation that could prevent (or could prevent prior to the next inspection) the ability to perform its design basis function. Degradations or conditions meeting the ACI349.3R-02 Tier 2 and 3 criteria will be entered into the sites CAP for evaluation and resolution.

The loss of material due to age-related degradation of ISFSI pad subcomponents will be evaluated by a qualified person in accordance with ACI 349.3R-02. A technical basis will be provided for any deviation from ACI349.3R-02 acceptance criteria.

The acceptance criteria for the groundwater chemistry program are commensurate with ASME Code Section XI, Subsection IWL, which states that an aggressive below-grade environment is defined as pH <

5.5, chlorides > 500 ppm, or sulfates > 1500 ppm. Failure to meet the acceptance criteria for the groundwater chemistry program will need further evaluation to determine condition of the neighboring below-grade structures. Any groundwater indications of concrete degradation will be entered into the corrective action program.

The radiation survey is to be taken 1 m from the VVM inlet vent (see dose point location 1 that is 1 meter adjacent to the VVM inlet vent for reference in Figure 5.I.1 of the HI-STORM 100 FSAR). The first inspection in the period of extended operation shall be considered as the baseline measurement. The acceptance criteria for the radiation surveys are:

1. Baseline radiation survey measurements shall be lower than the dose measurements taken at the time of cask loading.

Dose rate measurements for all subsequent radiation surveys shall be less than the baseline radiation survey dose rate measurement.

2.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-21

ATTACHMENT 1 TO HOLTEC LETTER 5014923 113 of 186 The acceptance criterion for radiation surveys are justified and sufficient to ensure compliance with 10 CFR 72.104 and identify dose rates that statistically exceed the dose rates provided in Chapter 5 of HI-STORM 100 FSARare dose rates that are less than a 10% increase from the previously measured dose rates

7. Corrective Corrective actions performed based on unacceptable effects will be in Actions accordance with the ISFSI Quality Assurance (QA) program. The QA Program ensures that corrective actions are completed within the ISFSI Corrective Action Program (CAP).

As applicable per the CAP program, ISFSI staff will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable.

Corrective actions will also identify the actions needed for increased scope or frequency of inspections, as necessary, based on any detected aging effects.

8. Confirmation The confirmation process will be commensurate with the ISFSI QA Process Program. The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the ISFSI CAP.
9. Administrative The ISFSI QA program and implementing procedures for this AMP will Controls address instrument calibration and maintenance, inspector requirements (commensurate with ACI 349.3R-02), record retention requirements, and document control.

This AMP will be updated periodically, as necessary, based on the tollgate assessments described in Chapter 4 of this application.

Inspection results will be documented and made available for NRC inspectors to view upon request.

10. Operating The ISFSI pad will be inspected before the CEC is placed in accordance Experience with existing operating procedures. The overall effectiveness of these inspections in maintaining the condition and functionality of the ISFSI Pad.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A A-22

ATTACHMENT 1 TO HOLTEC LETTER 5014923 114 of 186 APPENDIX B: HI-STORM 100 TLAAs B.0 Introduction This appendix outlines the Time Limited Aging Analyses (TLAA) for the HI-STORM 100 System. A TLAA meets the all of the following criteria:

(1) Involve SSCs important to safety within the scope of the specific-license renewal, as delineated in Subpart F of 10 CFR Part 72, or within the scope of the spent fuel storage CoC renewal, as delineated in Subpart L of 10 CFR Part 72, respectively.

(2) Consider the effects of aging.

(3) Involve time-limited assumptions defined by the current operating term.

(4) Were determined to be relevant by the specific licensee or certificate holder in making a safety determination (5) Involve conclusions or provide the basis of conclusions related to the capability of SSCs to perform their intended safety functions.

(6) Are contained or incorporated by reference in the design bases.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 B-1

ATTACHMENT 1 TO HOLTEC LETTER 5014923 115 of 186 B.1 Identification of HI-STORM 100 TLAAs Using the TLAA-identification criteria discussed in Section 3.2.4.1, the CoC, SER, Technical Specifications were reviewed and the following TLAAs were identified for further evaluation and disposition:

1. Neutron Absorber Depletion
2. HI-TRAC Trunnions
3. MPC Fatigue
4. Fuel Cladding Integrity HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 B-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 116 of 186 B.2 Neutron Absorber Depletion Section 6.3.2 of the HI-STORM 100 FSAR describes the boron depletion of the fixed neutron absorber within the MPC. The original analysis demonstrated that the boron depletion of the neutron absorbing material is negligible over a 50 year duration. The same analysis was re-performed in support of this license renewal request, as documented in Ref. B.2.1.

The analysis concludes that the total depletion of B-10 in Boral over a 500 year period is negligible (less than 1 ppm of total B-10 atoms depleted). Therefore, the TLAA for neutron absorber depletion shows that the neutron absorber will perform its intended function well beyond the extended storage period and that no aging management program is needed to manage the neutron absorber aging. The evaluation for Boral bounds the evaluation for the use of Metamic.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 B-3

ATTACHMENT 1 TO HOLTEC LETTER 5014923 117 of 186 B.3 HI-TRAC Trunnions The HI-STORM 100 FSAR Section 3.1.2.4 states that fatigue is not a concern for the HI-STORM 100 system, including the HI-TRAC. The same section relies on the inspection of the trunnions to ensure damaged components are not utilized. Similarly, the aging management review of the HI-TRAC, documented in Chapter 3 of this report, relies on the HI-TRAC AMP (including trunnion inspections) for managing any aging effects, and therefore no further analysis of the trunnions is needed.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 B-4

ATTACHMENT 1 TO HOLTEC LETTER 5014923 118 of 186 B.4 MPC Fatigue The HI-STORM FSAR, Subsection 3.1.2.4 discussion of MPC fatigue indicates that the low stress, high-cycle conditions of ambient temperature and insolation cycling during normal dry storage conditions cannot lead to a fatigue failure of the MPC, with endurance limits well in excess of 20,000 psi. However, it is possible that repeated lifting of the MPC might cause increased stresses and therefore lower the fatigue life of the MPC. To determine the maximum number of lifting cycles, the lifting points are evaluated against allowables from NUREG-0612, ANSI N14.6, and RG 3.61, with the maximum applicable stress limit for MPC components set as the secondary stress limit from ASME Code Section III Subsection NB. The detailed calculation is described in Ref. B.4.1. The calculation concludes that the allowable number of lifting cycles of the MPC, as shown in Table B-1 in this section, greatly exceeds the amount of lifts of an MPC that would be necessary over the 60 year extended storage of the MPC.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 B-5

ATTACHMENT 1 TO HOLTEC LETTER 5014923 119 of 186 B.5 Fuel Cladding Integrity Early amendments of the HI-STORM 100 system provided an analysis of the integrity of the fuel to be stored, which includes a time-based assumption, and could be considered a TLAA.

However, subsequently, the NRC issued ISG-11, Revision 3 which provides temperature limits for fuel. If fuel is maintained under those limits, there is no concern with time-based degradation. That ISG is now the licensing basis, and previous amendments meet those temperature limits. Therefore, the analysis is not re-performed for the extended period of operation, since the ISG provides the technical information which supports storage of fuel in the HI-STORM 100 system. Note, additional aging management activities for High Burnup Fuel are covered under the High Burnup Fuel AMP.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 B-6

ATTACHMENT 1 TO HOLTEC LETTER 5014923 120 of 186 B.6 References B.2.1 HI-951322R24, HI-STAR 100 Shielding Design and Analysis for Transport and Storage, Appendix 3 B.4.1 B.1.1 HI-2012787R22, Structural Calculation Package for MPC, Supplement 68 HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 B-7

ATTACHMENT 1 TO HOLTEC LETTER 5014923 121 of 186 Table B-1 Lifting Cycles Component Allowable Number of Lifting Cycles MPC 6750 Transfer Cask 3730 HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 B-8

ATTACHMENT 1 TO HOLTEC LETTER 5014923 122 of 186 APPENDIX C: SYSTEM INSPECTIONS C.0 Introduction There are two types of initial storage system inspections related to the HI-STORM 100 CoC renewal applications and initial AMP implementation, respectively. The first type, known as a pre-application inspection is intended to gather information to inform the development of the renewal application in general, and AMPs for specific SSCs in particular. The second, known as a baseline inspection, is essentially the first AMP inspection of the SSC, which is performed at a particular ISFSI at approximately the time when the storage system enters the period of extended storage.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 C-1

ATTACHMENT 1 TO HOLTEC LETTER 5014923 123 of 186 C.1 Pre-application Inspections Although a pre-application inspection is not a regulatory requirement, the HI-STORM 100 System has undergone a number of previous demonstrations which have informed the AMPs included in this application.

C.1.1 MPC / Overpack Internal During the week of November 18, 2013, proof of concept investigations were performed on two of the oldest loaded dry fuel storage canisters placed on the PSEG Nuclear Independent Spent Fuel Storage Installation (ISFSI). The inspection was a collaborative effort between PSEG Nuclear, Holtec International, EPRI, and a number of the national labs. The intent of the inspection was to support an industry wide initiative to collect data on the canister surface conditions associated with extended exposure to marine atmospheric conditions. All results were documented in Reference [C.1.1]. Degradation was not the focus of the investigation, but no unexpected evidence of degradation was found. The inspection also opportunistically took pictures of the condition of the internal overpack shell, which showed no signs of significant degradation. The equipment used in this inspection was able to see a large portion of the canister surface.

An additional investigation was performed at Diablo Canyon Nuclear Power Plant [C.1.2]. The conclusions were similar to those found at PSEG. Although Diablo Canyon maintains its own site-specific license, the design is the same as the HI-STORM 100 system and therefore the demonstration provided information to support the AMPs contained in this license.

The lessons learned from this inspection were incorporated into this application and AMPs, in the acceptance criteria and in the tooling techniques that will be used to perform the inspections.

C.1.2 Overpack External The HI-STORM 100 system FSAR already required an annual visual external examination, in Table 9.2.1. The results from a number of these examinations have been identified in Section 3.1.2 of this application. These previous inspections lessons learned have been incorporated into the acceptance criteria in the AMP in this application.

C.1.3 Transfer Cask Transfer casks in use at existing sites have been examined over the course of their use. The results from a number of these examinations have been identified in Section 3.1.2 of this application. These previous inspections lessons learned have been incorporated into the acceptance criteria in the AMP in this application.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 C-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 124 of 186 C.2 Baseline Inspections Baseline inspections are the first AMP inspections conducted at an ISFSI site at the approximate time the ISFSI enters the period of extended storage (i.e., 20 years after the first HI-STORM 100 system was placed in service). The baseline inspection for the site meets the criteria defined in the AMPs in Appendix A. This first (baseline) inspection shallould occur prior to entering the period of extended operation or no later thanwithin 365 days of the 20th anniversary of the initial overpack loading at the site or within 365 days of the issuance of the renewed license, whichever is later. All future inspections will occur with a 5 year frequency (+/- 1.25 years) starting from the baseline date. This schedule applies to the canister external inspection, overpack internal inspections, and groundwater monitoring for the HI-STORM 100U. For the overpack external inspections and HI-STORM 100U concrete inspections, the first (baseline) inspection shallould occur prior to entering the period of extended operation or no later than within 365 days of the 20th anniversary of the initial overpack loading at the site or within 365 days of the issuance of the renewed license, whichever is later. All future inspections will occur with a 1 year frequency

(+/- 0.25 years) starting from the baseline date. Since the other AMP inspections are pre-use type inspections they will occur before the first use of the applicable component once it has been in service more than 20 years. Note that the High Burnup Fuel AMP does not have an inspection component and the schedule is based on the demonstration project as described in the AMP in Appendix A.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 C-3

ATTACHMENT 1 TO HOLTEC LETTER 5014923 125 of 186 C.3 References

[C.1.1] HI-2146300, MPC Surface Inspection at Hope Creek Nuclear Generating Station, Revision 1, May 8, 2015.

[C.1.2] HI-2146301, MPC Surface Inspection at Diablo Canyon Power Plant, Revision 09-2, May 8, 2015.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10 C-4

ATTACHMENT 1 TO HOLTEC LETTER 5014923 126 of 186 APPENDIX D: AGING MANAGEMENT FSAR CHANGES The proposed FSAR changes are shown in context in the attached track change pages.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Proposed Rev. 10A D-1

ATTACHMENT 1 TO HOLTEC LETTER 5014923 127 of 186 1.2.1.4 Lifting Devices Lifting of the HI-STORM 100 System may be accomplished either by attachment at the top of the storage overpack ("top lift"), as would typically be done with a crane, or by attachment at the bottom

("bottom lift"), as would be effected by a number of lifting/handling devices.

For a top lift, the storage overpack is equipped with four threaded anchor blocks arranged circumferentially around the overpack. These anchor blocks are used for overpack lifting as well as securing the overpack lid to the overpack body. The storage overpack may be lifted with a lifting device that engages the anchor blocks with threaded studs and connects to a crane or similar equipment.

A bottom lift of the HI-STORM 100 storage overpack is affected by the insertion of four hydraulic jacks underneath the inlet vent horizontal plates (Figure 1.2.1). A slot in the overpack baseplate allows the hydraulic jacks to be placed underneath the inlet vent horizontal plate. The hydraulic jacks lift the loaded overpack to provide clearance for inserting or removing a device for transportation.

The standard design HI-TRAC transfer cask is equipped with two lifting trunnions and two pocket trunnions. The HI-TRAC 100D and 125D are equipped with only lifting trunnions. The lifting trunnions are positioned just below the top forging. The two pocket trunnions are located above the bottom forging and attached to the outer shell. The pocket trunnions are designed to allow rotation of the HI-TRAC. All trunnions are built from a high strength alloy with proven corrosion and non-galling characteristics. The lifting trunnions are designed in accordance with NUREG-0612 and ANSI N14.6. The lifting trunnions are installed by threading into tapped holes just below the top forging.

The top of the MPC lid is equipped with four threaded holes that allow lifting of the loaded MPC.

These holes allow the loaded MPC to be raised/lowered through the HI-TRAC transfer cask using lifting cleats. The threaded holes in the MPC lid are designed in accordance with NUREG-0612 and ANSI N14.6.

1.2.1.5 Design Life The design life of the HI-STORM 100 System is 640 years. This is accomplished by using material of construction with a long proven history in the nuclear industry and specifying materials known to withstand their operating environments with little to no degradation. A maintenance program, as specified in Chapter 9, is also implemented to ensure the HI-STORM 100 System will exceed its design life of 640 years. The design considerations that assure the HI-STORM 100 System performs as designed throughout the service life include the following:

HI-STORM Overpack and HI-TRAC Transfer Cask

  • Exposure to Environmental Effects
  • Material Degradation HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 1-65 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 128 of 186 Table 1.2.2 KEY PARAMETERS FOR HI-STORM 100 MULTI-PURPOSE CANISTERS PWR BWR Pre-disposal service life (years) 460 640 Design temperature, max./min.

725o/-40o 725o/-40o (oF)

Design internal pressure (psig)

Normal conditions 100 100 Off-normal/Short-term 110 110 conditions Accident Conditions 200 200 Total heat load, max. (kW) 36.9 36.9 Maximum permissible peak fuel cladding temperature:

Long Term Normal (oF) 752 752 Short Term Operations (oF) 752 or 1058 752 or 1058 Off-normal and Accident (oF) 1058 1058 Maximum normal condition design temperatures for the MPC fuel basket. A complete listing of design temperatures for all components is provided in Table 2.2.3.

Temperature based on off-normal minimum environmental temperatures specified in Section 2.2.2.2 and no fuel decay heat load.

See Section 4.5 for discussion of the applicability of the 1058oF temperature limit during MPC drying.

Maximum heat load shown is for regionalized loading.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 1-77 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-3

ATTACHMENT 1 TO HOLTEC LETTER 5014923 129 of 186 CHAPTER 2: PRINCIPAL DESIGN CRITERIA This chapter contains a compilation of design criteria applicable to the HI-STORM 100 System. The loadings and conditions prescribed herein for the MPC, particularly those pertaining to mechanical accidents, are far more severe in most cases than those required for 10CFR72 compliance. The MPC is designed to be in compliance with both 10CFR72 and 10CFR71 and therefore certain design criteria are overly conservative for storage. This chapter sets forth the loading conditions and relevant acceptance criteria; it does not provide results of any analyses. The analyses and results carried out to demonstrate compliance with the design criteria are presented in the subsequent chapters of this report.

This chapter is in full compliance with NUREG-1536, except for the exceptions and clarifications provided in Table 1.0.2. Table 1.0.2 provides the NUREG-1536 review guidance, the justification for the exception or clarification, and the Holtec approach to meet the intent of the NUREG-1536 guidance.

2.0 PRINCIPAL DESIGN CRITERIA The design criteria for the MPC, HI-STORM overpack, and HI-TRAC transfer cask are summarized in Tables 2.0.1, 2.0.2, and 2.0.3, respectively, and described in the sections that follow.

2.0.1 MPC Design Criteria General The MPC is designed for 640 years of service, while satisfying the requirements of 10CFR72. The adequacy of the MPC design for the design life is discussed in Section 3.4.12.

Structural The MPC is classified as important to safety. The MPC structural components include the internal fuel basket and the enclosure vessel. The fuel basket is designed and fabricated as a core support structure, in accordance with the applicable requirements of Section III, Subsection NG of the ASME Code, with certain NRC-approved alternatives, as discussed in Section 2.2.4. The enclosure vessel is designed and fabricated as a Class 1 component pressure vessel in accordance with Section III, Subsection NB of the ASME Code, with certain NRC-approved alternatives, as discussed in Section 2.2.4. The principal exception is the MPC lid, vent and drain port cover plates, and closure ring welds to the MPC lid and shell, as discussed in Section 2.2.4. In addition, the threaded holes in This chapter has been prepared in the format and section organization set forth in Regulatory Guide 3.61. However, the material content of this chapter also fulfills the requirements of NUREG-1536. Pagination and numbering of sections, figures, and tables are consistent with the convention set down in Chapter 1, Section 1.0, herein. Finally, all terms-of-art used in this chapter are consistent with the terminology of the glossary and component nomenclature of the drawings (Section 1.5).

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 2-1 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-4

ATTACHMENT 1 TO HOLTEC LETTER 5014923 130 of 186 baseplate welds and shell to shell weld is performed on the unloaded MPC.

Operations There are no radioactive effluents that result from storage or transfer operations. Effluents generated during MPC loading are handled by the plant's radwaste system and procedures.

Generic operating procedures for the HI-STORM 100 System are provided in Chapter 8. Detailed operating procedures will be developed by the licensee based on Chapter 8, site-specific requirements that comply with the 10CFR50 Technical Specifications for the plant, and the HI-STORM 100 System CoC.

Acceptance Tests and Maintenance The fabrication acceptance basis and maintenance program to be applied to the MPCs are described in Chapter 9. The operational controls and limits to be applied to the MPCs are discussed in Chapter

12. Application of these requirements will assure that the MPC is fabricated, operated, and maintained in a manner that satisfies the design criteria defined in this chapter.

Decommissioning The MPCs are designed to be transportable in the HI-STAR overpack and are not required to be unloaded prior to shipment off-site. Decommissioning of the HI-STORM 100 System is addressed in Section 2.4.

2.0.2 HI-STORM Overpack Design Criteria General The HI-STORM overpack is designed for 640 years of service, while satisfying the requirements of 10CFR72. The adequacy of the overpack design for the design life is discussed in Section 3.4.11.

Structural The HI-STORM overpack includes both concrete and structural steel components that are classified as important to safety.

The concrete material is defined as important to safety because of its importance to the shielding analysis. The primary function of the HI-STORM overpack concrete is shielding of the gamma and neutron radiation emitted by the spent nuclear fuel.

Unlike other concrete storage casks, the HI-STORM overpack concrete is enclosed in steel inner and outer shells connected to each other by radial ribs, and top and bottom plates. Where typical concrete storage casks are reinforced by rebar, the HI-STORM overpack is supported by the inner and outer shells connected by radial ribs. As the HI-STORM overpack concrete is not reinforced, the structural HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 2-5 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-5

ATTACHMENT 1 TO HOLTEC LETTER 5014923 131 of 186 Decommissioning Decommissioning considerations for the HI-STORM 100 System, including the overpack, are addressed in Section 2.4.

2.0.3 HI-TRAC Transfer Cask Design Criteria General The HI-TRAC transfer cask is designed for 640 years of service, while satisfying the requirements of 10CFR72. The adequacy of the HI-TRAC design for the design life is discussed in Section 3.4.11.

Structural The HI-TRAC transfer cask includes both structural and non-structural biological shielding components that are classified as important to safety. The structural steel components of the HI-TRAC, with the exception of the lifting trunnions, are designed and fabricated in accordance with the applicable requirements of Section III, Subsection NF, of the ASME Code with certain NRC-approved alternatives, as discussed in Section 2.2.4. The lifting trunnions and associated attachments are designed in accordance with the requirements of NUREG-0612 and Regulatory Guide 3.61 for non-redundant lifting devices.

The HI-TRAC transfer cask is designed for all normal, off-normal, and design basis accident condition loadings, as defined in Section 2.2. At a minimum, the HI-TRAC transfer cask must protect the MPC from deformation, provide continued adequate performance, and allow the retrieval of the MPC under all conditions. These design loadings include a side drop from the maximum allowable handling height, consistent with the technical specifications. The load combinations for which the HI-TRAC is designed are defined in Section 2.2.7. The physical characteristics of each MPC for which the HI-TRAC is designed are defined in Chapter 1.

Thermal The allowable temperatures for the HI-TRAC transfer cask structural steel components are based on the maximum temperature for material properties and allowable stress values provided in Section II of the ASME Code. The top lids of the HI-TRAC 125 and HI-TRAC 125D incorporate Holtite-A shielding material. This material has a maximum allowable temperature in accordance with the manufacturer's test data. The specific allowable temperatures for the structural steel and shielding components of the HI-TRAC are provided in Table 2.2.3. The HI-TRAC is designed for off-normal environmental cold conditions, as discussed in Section 2.2.2.2. The structural steel materials susceptible to brittle fracture are discussed in Section 3.1.2.3.

The HI-TRAC is designed for the maximum heat load analyzed for storage operations. When the MPC contains any high burnup fuel assemblies and the MPC decay heat is greater than the threshold heat load defined in Table 4.5.4, the Supplemental Cooling System (SCS) will be required for certain time periods while the MPC is inside the HI-TRAC transfer cask (see Section 4.5). The design HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 2-8 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-6

ATTACHMENT 1 TO HOLTEC LETTER 5014923 132 of 186 The Cask Transfer Facility shall be constructed to have a minimum design life of 640 years.{1}

P. Testing Requirements In addition to testing recommended in NUREG-0612 (1980), a structural adequacy test of the CTF structure at 125% of its operating load prior to its first use in a cask loading campaign shall be performed. This test should be performed in accordance with the guidance provided in the CMAA Specification 70 [2.2.16]. {1}

Q. Quality Assurance Requirements All components of the CTF shall be manufactured in full compliance with the quality assurance requirements applicable to the ITS category of the component as set forth in the Holtec QA program. {1, 2, 3}

R. Documentation Requirements

i. O&M Manual: An Operations and Maintenance Manual shall be prepared which contains, at minimum, the following items of information: {1, 2, 3}
  • Maintenance Drawings
  • Operating Procedures ii. Design Report: if required by the safety classification, a QA-validated design report documenting full compliance with the provisions of this specification shall be prepared and archived for future reference in accordance with the provisions of the Holtec QA program. {1, 2, 3}

2.3.3.2 Instrumentation As a consequence of the passive nature of the HI-STORM 100 System, instrumentation which is important to safety is not necessary. No instrumentation is required or provided for HI-STORM 100 storage operations, other than normal security service instruments and TLDs.

However, in lieu of performing the periodic inspection of the HI-STORM overpack vent screens, temperature elements may be installed in two of the overpack exit vents to continuously monitor the air temperature. If the temperature elements and associated temperature monitoring instrumentation are used, they shall be designated important to safety as specified in Table 2.2.6.

The temperature elements and associated temperature monitoring instrumentation provided to monitor the air outlet temperature shall be suitable for a temperature range of -40F to 500F. At a HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 2-196 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-7

ATTACHMENT 1 TO HOLTEC LETTER 5014923 133 of 186 2.4 DECOMMISSIONING CONSIDERATIONS Efficient decommissioning of the ISFSI is a paramount objective of the HI-STORM 100 System.

The HI-STORM 100 System is ideally configured to facilitate rapid, safe, and economical decommissioning of the storage site.

The MPC is being licensed for transport off-site in the HI-STAR 100 dual-purpose cask system (Reference Docket No. 71-9261). No further handling of the SNF stored in the MPC is required prior to transport to a licensed centralized storage facility or licensed repository.

The MPC which holds the SNF assemblies is engineered to be suitable as a waste package for permanent internment in a deep Mined Geological Disposal System (MGDS). The materials of construction permitted for the MPC are known to be highly resistant to severe environmental conditions. No carbon steel, paint, or coatings are used or permitted in the MPC in areas where they could be exposed to spent fuel pool water or the ambient environment. Therefore, the SNF assemblies stored in the MPC should not need to be removed. However, to ensure a practical, feasible method to defuel the MPC, the top of the MPC is equipped with sufficient gamma shielding and markings locating the drain and vent locations to enable semiautomatic (or remotely actuated) boring of the MPC lid to provide access to the MPC vent and drain. The circumferential welds of the MPC lid closure ring can be removed by semiautomatic or remotely actuated means, providing access to the SNF.

Likewise, the overpack consists of steel and concrete rendering it suitable for permanent burial.

Alternatively, the MPC can be removed from the overpack, and the latter reused for storage of other MPCs.

In either case, the overpack would be expected to have no interior or exterior radioactive surface contamination. Any neutron activation of the steel and concrete is expected to be extremely small, and the assembly would qualify as Class A waste in a stable form based on definitions and requirements in 10CFR61.55. As such, the material would be suitable for burial in a near-surface disposal site as Low Specific Activity (LSA) material.

If the MPC needs to be opened and separated from the SNF before the fuel is placed into the MGDS, the MPC interior metal surfaces will be decontaminated using existing mechanical or chemical methods. This will be facilitated by the MPC fuel basket and interior structures' smooth metal surfaces designed to minimize crud traps. After the surface contamination is removed, the MPC radioactivity will be diminished significantly, allowing near-surface burial or secondary applications at the licensee's facility.

It is also likely that both the overpack and MPC, or extensive portions of both, can be further decontaminated to allow recycle or reuse options. After decontamination, the only radiological hazard the HI-STORM 100 System may pose is slight activation of the HI-STORM 100 materials caused by irradiation over a 640-year storage period.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 2-207 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-8

ATTACHMENT 1 TO HOLTEC LETTER 5014923 134 of 186 Due to the design of the HI-STORM 100 System, no residual contamination is expected to be left behind on the concrete ISFSI pad. The base pad, fence, and peripheral utility structures will require no decontamination or special handling after the last overpack is removed.

To evaluate the effects on the MPC and HI-STORM overpack caused by irradiation over a 40-year storage period, the following analysis is provided. Table 2.4.1 provides the conservatively determined quantities of the major nuclides after 40 years of irradiation. The calculation of the material activation is based on the following:

  • Beyond design basis fuel assemblies (B&W 15x15, 4.8% enrichment, 70,000 MWD/MTU, and five-year cooling time) stored for 40 years. A constant source term for 40 years was used with no decrease in the neutron source term. This bounds the source term associated with the limiting PWR burnup of 68,200 MWD/MTU.
  • Material quantities based on the drawings in Section 1.5.
  • A constant flux equal to the initial loading condition is conservatively assumed for the full 40 years.
  • Material activation is based on MCNP-4A calculations.

As can be seen from the material activation results presented in Table 2.4.1, the MPC and HI-STORM overpack activation is very low, even including the very conservative assumption of a constant flux for 40 years. The results for the concrete in the HI-STORM overpack can be conservatively applied to the ISFSI pad. This is extremely conservative because the overpack shields most of the flux from the fuel and, therefore, the ISFSI pad will experience a minimal flux.

This calculation was based on 40 years and based on the minimal activation along with the guidance in NUREG-2214 that indicates radiation impacts over 60 years are negligible, the results are assumed to be similar for a 60 year storage period.

In any case, the HI-STORM 100 System would not impose any additional decommissioning requirements on the licensee of the ISFSI facility per 10CFR72.30, since the HI-STORM 100 System could eventually be shipped from the site.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 2-208 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-9

ATTACHMENT 1 TO HOLTEC LETTER 5014923 135 of 186 Total area for an array of twelve CECs: 4,944 ft2 Bare CEC metal exposed: 4,944 ft2 x 0.085 or 420 ft2 Current required: 420 ft2 x 1 mA/ft2 or 420 mA The following is additional data applicable to Figure 2.I.1.

Approximate Anode quantity: 11 Approximate Anode size: 5 in dia. x 120 in. long Approximate Backfill quantity: 6,000 lbs of carbonaceous backfill The total number of anodes required is determined primarily by the total current requirements of the CEC metal to be protected and the optimum current density of the anode material selected.

Graphite is a semi-consumable anode. Graphite typically has experienced corrosion rates of 1.5 to 2.16 lbs /amp year [2.I.3] or as determined by experiment, 0.08 grams per square meter of anode per amp-hour of current (at 30 C, 40 mA/cm2 anode current density) [2.I.4]. A computed anode life of less than 460 years is acceptable as long as appropriate measures are taken to facilitate the replacement of anodes during the design phase and appropriate maintenance planning measures are implemented. Use of carbonaceous backfill should be considered since it can substantially lengthen the anode life. Inert (non-consumable) platinized anodes may also be considered.

v. Concrete Encasement (Corrosion Mitigation Measure)

If concrete encasement is used, it shall be implemented in accordance with the requirements in Supplement 3.I, Subsection 3.I.4.1 and appropriate references.

The following points shall also be taken into consideration:

  • The effect of the concrete encasement on the ICCPS, if an ICCPS is also implemented.
  • The concrete encasement should not interfere with the settlement of the TSP (which provides the transporter support surface) without appropriate evaluation.

vi. Retaining Wall Because the subgrade within and around an operating 100U ISFSI serves a principal shielding function, it is essential that any excavation activity adjacent to the ISFSI (e.g., to build an extension of the ISFSI), must not disturb the soil in the Radiation Protection Space (RPS) shown in the licensing drawings (Section 1.I.5).

The extent of the RPS is set down to ensure, with sufficient margin of safety, that the ISFSI will continue to meet all relevant safety criteria under all applicable conditions of storage including normal, off-normal, extreme environmental phenomena and accident conditions. For example, the RPS must provide sufficient buffer so that design basis projectiles (large, medium, and penetrant missiles) will not access an MPC stored in a VVM cavity. In this case, as explained in Supplement 3.I, the incident missile is assumed to act when a deep cavity has been excavated contiguous to the HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 18 REPORT HI-2002444 2.I-12 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-10

ATTACHMENT 1 TO HOLTEC LETTER 5014923 136 of 186 HI-STORM 100S, Version B since the structural material at the top of the cask that would be locally deformed after a tipover event is essentially the same.

3.4.11 Storage Overpack and HI-TRAC Transfer Cask Service Life The term of the 10CFR72, Subpart L C of C, granted by the NRC is 20 years, renewed for an additional 40 years; therefore, the License Life (please see glossary) of all components is 620 years. Nonetheless, tThe HI-STORM 100 and 100S Storage overpacks and the HI-TRAC transfer cask are engineered for 640 years of design life, while satisfying the conservative design requirements defined in Chapter 2, including the regulatory requirements of 10CFR72. In addition, the storage overpack and HI-TRAC are designed, fabricated, and inspected under the comprehensive Quality Assurance Program discussed in Chapter 13 and in accordance with the applicable requirements of the ACI and ASME Codes. This assures high design margins, high quality fabrication, and verification of compliance through rigorous inspection and testing, as describe in Chapter 9 and the design drawings in Section 1.5. Technical Specifications defined in Chapter 12 assure that the integrity of the cask and the contained MPC are maintained throughout the components' design life. The design life of a component, as defined in the Glossary, is the minimum duration for which the equipment or system is engineered to perform its intended function if operated and maintained in accordance with the FSAR. The design life is essentially the lower bound value of the service life, which is the expected functioning life of the component or system. Therefore, component longevity should be: licensed life < design life < service life.

(The licensed life, enunciated by the USNRC, is the most pessimistic estimate of a components life span.) For purposes of further discussion, we principally focus on the service life of the HI-STORM 100 System components that, as stated earlier, is the reasonable expectation of equipments functioning life span.

The service life of the storage overpack and HI-TRAC transfer cask is further discussed in the following sections.

3.4.11.1 Storage Overpack The principal design considerations that bear on the adequacy of the storage overpack for the service life are addressed as follows:

Exposure to Environmental Effects In the following text, all references to HI-STORM 100 also apply to HI-STORM 100S and to the HI-STORM 100S Version B. All exposed surfaces of HI-STORM 100 are made from ferritic steels that are readily painted. Concrete, which serves strictly as a shielding material, is completely encased in steel. Therefore, the potential of environmental vagaries such as spalling of concrete, are ruled out for HI-STORM 100. Under normal storage conditions, the bulk temperature of the HI-STORM 100 storage overpack will, because of its large thermal inertia, change very gradually with time. Therefore, material degradation from rapid thermal ramping conditions is not credible for the HI-STORM 100 storage overpack. Similarly, corrosion of structural steel embedded in the concrete structures due to salinity in the environment at coastal sites is not a concern for HI-STORM 100 because HI-STORM 100 does not rely on rebars (indeed, it contains no rebars). As HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3-188 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-11

ATTACHMENT 1 TO HOLTEC LETTER 5014923 137 of 186 discussed in Appendix 1.D, the aggregates, cement and water used in the storage cask concrete are carefully controlled to provide high durability and resistance to temperature effects. The configuration of the storage overpack assures resistance to freeze-thaw degradation. In addition, the storage overpack is specifically designed for a full range of enveloping design basis natural phenomena that could occur over the 460-year design life of the storage overpack as defined in Subsection 2.2.3 and evaluated in Chapter 11.

Material Degradation The relatively low neutron flux to which the storage overpack is subjected cannot produce measurable degradation of the cask's material properties and impair its intended safety function.

Exposed carbon steel components are coated to prevent corrosion. The controlled environment of the ISFSI storage pad mitigates damage due to direct exposure to corrosive chemicals that may be present in other industrial applications.

Maintenance and Inspection Provisions The requirements for periodic inspection and maintenance of the storage overpack throughout the 640-year design life are defined in Chapter 9. These requirements include provisions for routine inspection of the storage overpack exterior and periodic visual verification that the ventilation flow paths of the storage overpack are free and clear of debris. ISFSIs located in areas subject to atmospheric conditions that may degrade the storage cask or canister should be evaluated by the licensee on a site-specific basis to determine the frequency for such inspections to assure long-term performance. In addition, the HI-STORM 100 System is designed for easy retrieval of the MPC from the storage overpack should it become necessary to perform more detailed inspections and repairs on the storage overpack.

The above findings are consistent with those of the NRC's Waste Confidence Decision Review

[3.4.11], which concluded that dry storage systems designed, fabricated, inspected, and operate in accordance with such requirements are adequate for a 100-year service life while satisfying the requirements of 10CFR72.

3.4.11.2 Transfer Cask The principal design considerations that bear on the adequacy of the HI-TRAC Transfer Cask for the service life are addressed as follows:

Exposure to Environmental Effects All transfer cask materials that come in contact with the spent fuel pool are coated to facilitate decontamination. The HI-TRAC is designed for repeated normal condition handling operations with high factor of safety, particularly for the lifting trunnions, to assure structural integrity. The resulting cyclic loading produces stresses that are well below the endurance limit of the trunnion material, and therefore, will not lead to a fatigue failure in the transfer cask. All other off-normal or postulated accident conditions are infrequent or one-time occurrences that do not contribute significantly to fatigue. In addition, the transfer cask utilizes materials that are not susceptible to HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3-189 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-12

ATTACHMENT 1 TO HOLTEC LETTER 5014923 138 of 186 brittle fracture during the lowest temperature permitted for loading, as discussed in Chapter 12.

Material Degradation All transfer cask materials that are susceptible to corrosion are coated. The controlled environment in which the HI-TRAC is used mitigates damage due to direct exposure to corrosive chemicals that may be present in other industrial applications. The infrequent use and relatively low neutron flux to which the HI-TRAC materials are subjected do not result in radiation embrittlement or degradation of the HI-TRAC's shielding materials that could impair the HI-TRAC's intended safety function. The HI-TRAC transfer cask materials are selected for durability and wear resistance for their deployment.

Maintenance and Inspection Provisions The requirements for periodic inspection and maintenance of the HI-TRAC transfer cask throughout the 640-year design life are defined in Chapter 9. These requirements include provisions for routine inspection of the HI-TRAC transfer cask for damage prior to each use, including an annual inspection of the lifting trunnions. Precautions are taken during lid handling operations to protect the sealing surfaces of the pool lid. The leak tightness of the liquid neutron shield is verified periodically. The water jacket pressure relief valves and other fittings used can be easily removed.

3.4.12 MPC Service Life The term of the 10CFR72, Subpart L C of C, granted by the NRC (i.e., licensed life) is 20 years, renewed for an additional 40 years. Nonetheless, tThe HI-STORM 100 MPC is designed for 640 years of design life, while satisfying the conservative design requirements defined in Chapter 2, including the regulatory requirements of 10CFR72. Additional assurance of the integrity of the MPC and the contained SNF assemblies throughout the 640-year life of the MPC is provided through the following:

  • Design, fabrication, and inspection in accordance with the applicable requirements of the ASME Code as described in Chapter 2 assures high design margins.
  • Fabrication and inspection performed in accordance with the comprehensive Quality Assurance program discussed in Chapter 13 assures competent compliance with the fabrication requirements.
  • Use of materials with known characteristics, verified through rigorous inspection and testing, as described in Chapter 9, assures component compliance with design requirements.
  • Use of welding procedures in full compliance with Section III of the ASME Code ensures high-quality weld joints.

Technical Specifications, as defined in Chapter 12, have been developed and imposed on the MPC that assure that the integrity of the MPC and the contained SNF assemblies are maintained HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3-190 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-13

ATTACHMENT 1 TO HOLTEC LETTER 5014923 139 of 186 throughout the 640-year design life of the MPC.

The principal design considerations bearing on the adequacy of the MPC for the service life are summarized below.

Corrosion All MPC materials are fabricated from corrosion-resistant austenitic stainless steel and passivated aluminum. The corrosion-resistant characteristics of such materials for dry SNF storage canister applications, as well as the protection offered by these materials against other material degradation effects, are well established in the nuclear industry. The moisture in the MPC is removed to eliminate all oxidizing liquids and gases and the MPC cavity is backfilled with dry inert helium at the time of closure to maintain an atmosphere in the MPC that provides corrosion protection for the SNF cladding throughout the dry storage period. The preservation of this non-corrosive atmosphere is assured by the inherent sealworthiness of the MPC confinement boundary integrity (there are no gasketed joints in the MPC).

Structural Fatigue The passive non-cyclic nature of dry storage conditions does not subject the MPC to conditions that might lead to structural fatigue failure. Ambient temperature and insolation cycling during normal dry storage conditions and the resulting fluctuations in MPC thermal gradients and internal pressure is the only mechanism for fatigue. These low-stress, high-cycle conditions cannot lead to a fatigue failure of the MPC that is made from stainless alloy stock (endurnce limit well in excess of 20,000 psi). All other off-normal or postulated accident conditions are infrequent or one-time occurrences, which cannot produce fatigue failures. Finally, the MPC uses materials that are not susceptible to brittle fracture.

Maintenance of Helium Atmosphere The inert helium atmosphere in the MPC provides a non-oxidizing environment for the SNF cladding to assure its integrity during long-term storage. The preservation of the helium atmosphere in the MPC is assured by the robust design of the MPC confinement boundary described in Section 7.1. Maintaining an inert environment in the MPC mitigates conditions that might otherwise lead to SNF cladding failures. The required mass quantity of helium backfilled into the canister at the time of closure and the associated fabrication and closure requirements for the canister are specifically set down to assure that an inert helium atmosphere is maintained in the canister throughout the 640-year design life.

Allowable Fuel Cladding Temperatures The helium atmosphere in the MPC promotes heat removal and thus reduces SNF cladding temperatures during dry storage. In addition, the SNF decay heat will substantially attenuate over a 640-year dry storage period. Maintaining the fuel cladding temperatures below allowable levels during long-term dry storage mitigates the damage mechanism that might otherwise lead to SNF cladding failures. The allowable long-term SNF cladding temperatures used for thermal HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3-191 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-14

ATTACHMENT 1 TO HOLTEC LETTER 5014923 140 of 186 acceptance of the MPC design are conservatively determined, as discussed in Section 4.3.

Neutron Absorber Boron Depletion The effectiveness of the fixed borated neutron absorbing material used in the MPC fuel basket design requires that sufficient concentrations of boron be present to assure criticality safety during worst case design basis conditions over the 640-year design life of the MPC. Information on the characteristics of the borated neutron absorbing material used in the MPC fuel basket is provided in Subsection 1.2.1.3.1. The relatively low neutron flux, which will continue to decay over time, to which this borated material is subjected, does not result in significant depletion of the material's available boron to perform its intended safety function. In addition, the boron content of the material used in the criticality safety analysis is conservatively based on the minimum specified boron areal density (rather than the nominal), which is further reduced by 25% for analysis purposes, as described in Section 6.1. Analysis discussed in Section 6.3.2 demonstrates that the boron depletion in the neutron absorber material is negligible over a 50-year duration. To support license renewal, the evaluation of boron depletion was re-performed and found to be negligible for time frames well beyond the 60 year license renewal time period. Thus, sufficient levels of boron are present in the fuel basket neutron absorbing material to maintain criticality safety functions over the 640-year design life of the MPC.

The above findings are consistent with those of the NRC's Waste Confidence Decision Review, which concluded that dry storage systems designed, fabricated, inspected, and operated in the manner of the requirements set down in this document are adequate for a 100-year service life, while satisfying the requirements of 10CFR72.

3.4.13 Design and Service Life The discussion in the preceding sections seeks to provide the logical underpinnings for setting the design life of the storage overpacks, the HI-TRAC transfer cask, and the MPCs as forty sixty years.

Design life, as stated earlier, is a lower bound value for the expected performance life of a component (service life). If operated and maintained in accordance with this Final Safety Analysis Report, Holtec International expects the service life of its HI-STORM 100 and HI-STORM 100S Versions components to substantially exceed their design life values.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3-192 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-15

ATTACHMENT 1 TO HOLTEC LETTER 5014923 141 of 186 Table 3.7.2 COMPLIANCE OF HI-STORM 100 SYSTEM WITH 10CFR72.236(e), ET ALS.

Location of Supporting Item Compliance Information in This Document

i. Redundant sealing of Two physically independent lids, each separately welded to the MPC shell Section 1.5, Drawings confinement systems. (Enclosure Vessel shell) provide a redundant confinement system.

Section 7.1.

ii. Adequate heat removal Thermal analyses presented in Chapter 4 show that the HI-STORM 100 Sections 4.4 and Sections 9.1 and without active cooling System will remove the decay heat generated from the stored spent fuel by 9.2 systems. strictly passive means and maintain the system temperature within prescribed limits.

iii. Storage of spent fuel for a The service life of the MPC, storage overpack, and HI-TRAC are engineered Subsections 3.4.11 and 3.4.12 minimum of 20 years. to be in excess of 420 years.

iv. Compatibility with wet or dry

  • The system is designed to eliminate any material significant Subsection 3.4.1 spent fuel loading and interactions in the wet (spent fuel pool) environment.

unloading facilities.

  • The HI-TRAC transfer cask is engineered for full compatibility with Subsection 8.1.1 the MPCs, and standard loading and unloading facilities.
  • The HI-TRAC System is engineered for MPC transfer on the ISFSI Subsection 8.1.1 pad with full consideration of ALARA and handling equipment compatibility.
v. Ease of decontamination.
  • The external surface of the multi-purpose canister is protected from Figures 8.1.13 and 8.1.14 contamination during fuel loading through a custom designed sealing device.
  • The HI-STORM storage overpack is not exposed to contamination Chapter 8
  • All exposed surfaces of the HI-TRAC transfer cask are coated to aid Section 1.5, Drawings in decontamination HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3-276 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-16

ATTACHMENT 1 TO HOLTEC LETTER 5014923 142 of 186 Section 3.4 contains all required information associated with the MPCs and with the HI-TRAC transfer cask and is not repeated here. Results reported in this supplement section are generally applicable only to the HI-STORM 100U VVM.

3.I.4.1 Chemical and Galvanic Reactions In order to provide reasonable assurance that the VVM will meet its intended Design Life of 640 years (the License Life is 620 years) and perform its intended safety function(s), chemical and galvanic reactions and other potentially degrading mechanisms must be accounted for in its design and construction.

The HI-STORM 100U VVM is a buried structure and as such chemical and galvanic reactions and other potentially degrading factors are, in some respects, more challenging than for aboveground models. Although the CEC is not a part of the MPC containment boundary, it should not corrode to the extent where localized in-leakage of water occurs or where gross general corrosion prevents the component from performing its primary safety function. In the following, considerations in the VVMs design and construction consistent with the applicable guidance provided in ISG-15 [3.I.3]

are summarized.

All VVM components are galvanically compatible. Except for the CEC exterior surfaces, all steel surfaces of the VVM are lined and coated with the same surface preservative that is used in the aboveground HI-STORM overpacks. (The surface preservative used to protect HI-STORM 100S steel surfaces is a proven zinc rich inorganic/metallic material that protects galvanically and has self healing characteristics for added assurance). All exposed surfaces interior to the VVM, as stated in Supplement 1.I, are accessible for the reapplication of surface preservative, if necessary.

The steel Divider Shell requires insulation to perform its primary thermal function. The insulation selected shall be suitable for high temperature and high humidity operation and shall be foil faced, jacketed or otherwise made water resistant to ensure the required thermal resistance is maintained in accordance with Supplement 4.I. The high zinc content in the coating of the Divider Shell provides protection for both the Divider Shell and the jacketing or foil from any potential galvanic corrosion concerns. With respect to radiation resistance, the insulation blanket does not contain any organic binders. The damage threshold for ceramics is known to be approximately 1x1010 Rads. Chloride corrosion is not a concern since chloride leachables are limited and sufficiently low and the Divider Shell is not made from stainless steel [3.I.20]. Stress corrosion cracking of the foil or jacketing, whether made from stainless steel or other material is not an applicable corrosion mechanism due to minimal stresses derived from self-weight. The foil or jacketing and attachment hardware shall either have sufficient corrosion resistance (e.g. stainless steel, aluminum or galvanized steel) or shall be protected with a suitable surface preservative. The insulation is adequately secured to prevent significant blockage of the ventilation passages in case of failure of a single attachment (strap, clamp, bolt or other attachment hardware). The following table provides the acceptance criteria for the selection of insulation material for the Divider Shell and ranks them in order of importance.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3.I-4 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-17

ATTACHMENT 1 TO HOLTEC LETTER 5014923 143 of 186 Acceptance Criteria for the Selection of the Insulation Material Rank Criteria 1 Adequate thermal resistance 2 Adequate high temperature resistance 3 Adequate humidity resistance 4 Adequate radiation resistance 5 Adequate resistance to the ambient environment 6 Sufficiently low chloride leachables 7 Adequate integrity and resistance to degradation and corrosion during long-term storage Kaowool ceramic fiber insulation [3.I.20] is selected as one that satisfies the acceptance criteria to the maximum degree. The Kaowool insulation material provides excellent resistance to chemical attack and is not degraded by oil or water. Alternatively, a Holtec approved equivalent that meets the acceptance criteria set forth in the table above may be used.

The CEC Container Shell, which is exposed to the substrate, requires additional pre-emptive measures to prevent corrosion, if the substrate is of aggressive chemistry. This subsection provides a description of corrosion mitigation measures required to be implemented to protect the HI-STORM 100 VVM. Because the guiding principle in the HI-STORM Systems is to target a service life of 100 years so as to guarantee a design life of 640 years, these corrosion prevention measures are in addition to the preemptively incorporated standard corrosion allowance of 1/8-inch applied to the subterranean parts of the CEC in direct contact with the surrounding substrate. Calculation of the required CEC Container Shell and Bottom Plate thicknesses on a site-specific basis may indicate the availability of an additional corrosion reserve.

Soil Corrosivity and Corrosion Mitigation Measures for the Exterior of the CEC Corrosion mitigation of the exterior of the CEC warrants special consideration for the following reasons: (i) inaccessibility of the exterior coated surface after installation (ii) potential for a highly aggressive (i.e., corrosive) soil environment at certain sites, and (iii) potential for a high radiation field. Since the buried configuration will not allow for the reapplication of surface preservative, corrosion mitigation measures shall be determined after careful evaluation of the soils corrosivity at the users ISFSI site.

To evaluate soil corrosivity, a 10 point soil-test evaluation procedure, in accordance with the guidelines of Appendix A of ANSI/AWWA C105/A21 [3.I.4], will be utilized. The classical soil evaluation criteria in the aforementioned standard focuses on parameters such as: 1) resistivity, 2) pH, 3) redox (oxidation-reduction) potential, 4) sulfides, 5) moisture content, 6) potential for stray current, and 7) experience with existing installations in the area. Using the procedure outlined in ref. [3.I.4], the ISFSI soil environment corrosivity is categorized as either mild for a soil test evaluation resulting in 9 points or less or aggressive for a soil test evaluation resulting in 10 HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3.I-5 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-18

ATTACHMENT 1 TO HOLTEC LETTER 5014923 144 of 186 Acceptance Criteria for the Selection of Coatings Rank Criteria compatible with the ICCPS (if used) 2a

  • adequate dielectric strength
  • adequate resistance to cathodic disbondment compatible with concrete encasement (if used) 2b
  • adequate resistance to high alkalinity 3 adequate radiation resistance 4 adequate adhesion to steel 5 adequate bendability/ductility/cracking resistance/abrasion resistance 6 adequate strength to resist handling abuse and substrate stress The Keeler & Long polyamide-epoxy coating is selected as one that satisfies the acceptance criteria to the maximum degree. Alternatively, a Holtec approved equivalent that meets the acceptance criteria set forth in the table above may be used.

ii. Concrete Encasement The CEC concrete encasement shall provide a minimum of 5 inches of cover to provide a pH buffering effect for additional corrosion mitigation. The above concrete cover thickness has been conservatively determined for a 100-year service life in a strongly aggressive environment based on the concrete corrosion/degradation data provided in the literature [3.I.12, Table 5.3] (1.2 mm/yr surface depth failure rate). The required 5 inch minimum thickness is more conservative than that recommended in ACI Codes, such as ACI 318 [3.3.2], which call for up to 3 inches of concrete cover over steel reinforcement in aggressive environments. Considering that the concrete encasement is restricted to mild soil environments (unless used in conjunction with cathodic protection) and has a non-structural role, the 5 inch concrete encasement thickness is considered more than sufficient to provide reasonable assurance that a 640 year service life can be achieved.

The lowest part of the CEC sits in a recessed region of the Support Foundation with an annular gap normally filled with substrate. If present, the CEC concrete encasement slurry will fill this annular gap during construction.

The function of the concrete encasement is for corrosion mitigation only; however, cracks larger than hairline cracks may significantly reduce its effectiveness. To control size and population of cracks, concrete reinforcement is included. The following reinforcement methods may be applied:

a. Fiber reinforcement: Fiber reinforcement may be of several materials, including steel, glass and plastic (polypropylene). The selection of the fiber reinforcement material shall be such that adequate resistance to radiation and high alkalinity is maintained. If using steel fibers, adequate damage protection of the CEC coating shall be ensured during concrete placement per written procedures. Steel fiber shall be implemented using written procedures and the applicable guidance from ACI 544.3R [3.I.25] or a similar consensus code or standard.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3.I-7 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-19

ATTACHMENT 1 TO HOLTEC LETTER 5014923 145 of 186 3.I.4.8.2 Tornado Missile Protection during Construction The number of VVMs in a HI-STORM 100U ISFSI may vary depending on a users need. While there is a minimum spacing (pitch) requirement (see licensing drawing in Subsection 1.I.5), there is no limitation on the maximum spacing. Furthermore, a module array may have a non-rectangular external contour such as shown in the licensing drawing with a trapezoidal contour. Finally, an ISFSI may be constructed in multiple campaigns to allow the user to align the VVM cavity construction schedule with the plants fuel storage needs. Any ISFSI constructed in one campaign shall have the following mandatory perimeter protection features:

i. The Radiation Protection Space (RPS) shall extend to an appropriate distance beyond the outer surface of the CEC shell (see licensing drawing in Subsection 1.I.5). Calculations have been performed [3.I.27] that confirm that a 10 distance beyond the outer surface of the CEC shell is sufficient to prevent the 8 diameter rigid cylindrical missile (defined in Table 2.I.1 and is the most penetrating of the missile types considered in this FSAR) from contacting the CEC shell should this missile strike the exposed cut from the adjacent construction. The penetration analysis conservatively assumed a subgrade with minimum resistance to missile penetration and the formulation described in [3.I.30].

ii. Unless a retaining wall (see licensing drawing) has been built to confine and retain the subgrade at the boundary of the RPS (or beyond) in the particular direction of excavation, an Excavation Exclusion Zone (EEZ) shall be defined within which any excavation activity during an operating ISFSI is prohibited (see Subsection 2.I.2). The retaining wall is the EEZ boundary if the retaining wall is located at or beyond the RPS.

3.I.4.9 HI-STORM 100U VVM Service Life The VVM is engineered for 640 years of design life, while satisfying the conservative design requirements defined in Supplement 2.I. For information supporting the 640 year design life addressing chemical and galvanic reactions as well as other potentially degrading factors see Subsection 3.I.4.1. Requirements for periodic inspection and maintenance of the HI-STORM 100U VVM throughout the 640-year design life are defined in Supplement 9.I. The VVM is designed, fabricated, and inspected under the comprehensive Quality Assurance Program discussed in Chapter 13.

3.I.5 FUEL RODS No new analysis of fuel rods is required for storage of an MPC in a HI-STORM 100U VVM.

3.I.6 SUPPLEMENTAL DATA 3.I.6.1 Additional Codes and Standards Referenced in HI-STORM 100 System Design and Fabrication No additional Codes and Standards are added for the HI-STORM 100U system.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3.I-30 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-20

ATTACHMENT 1 TO HOLTEC LETTER 5014923 146 of 186 The creep effect would tend to shorten the fuel basket under the self-weight of the basket. An illustrative calculation of the cumulative reduction of the basket length is presented below to demonstrate the insignificant role of creep in the MPC-68M fuel basket.

The in-plane compressive stress, , at height x in the basket panel is given by

= (H-x) (3.III.1) where:

= weight density of Metamic-HT H = height of the fuel basket Using the above stress equation, the total creep shrinkage, , is given by H

= f (, T)dx (3.III.2) o where:

T = panels metal temperature (conservatively assumed to be 375°C for a period of 60 years)

H = height of the basket (conservatively assumed to be 200 inches)

Using the creep equation (provided in [1.III.3]) and performing the above integration numerically yields = 0.138 inch. In other words, the computed shrinkage of the basket is less than 0.069% of its original length. Therefore, it is concluded that for the vertical storage configuration the creep effects of the MPC-68M fuel basket are insignificant due to absence of any meaningful loads on the panels. Therefore, creep in the Metamic-HT fuel basket is not a matter of safety concern.

ii) Fuel Basket Boron Depletion The similarities between Metamic-HT and Metamic (classic) neutron absorbers and their exposure to the same long-term conditions of storage in the HI-STORM 100 system provide a logical basis to expect negligible neutron absorber boron depletion in Metamic-HT. However, to assure criticality safety during worst case design basis conditions over the 40-year design life, the analysis discussed in Subsection 6.III demonstrates that the boron depletion in the Metamic-HT is negligible over a 50-year duration. Thus, sufficient levels of boron are present in the fuel basket to maintain criticality safety over the 640-year design life of the MPC.

3.III.4.12.2 Basket Shim Considerations:

i) Basket Shim Creep Like the fuel basket, the basket shims are not subject to any significant loading during storage. The ability of the basket shims (made of a creep resistant aluminum alloy) has been evaluated and qualified in Docket No. 71-9325 [2.III.6.2] for transport applications where the stress level (in HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 17 REPORT HI-2002444 3.III-12 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-21

ATTACHMENT 1 TO HOLTEC LETTER 5014923 147 of 186 6.1 DISCUSSION AND RESULTS In conformance with the principles established in NUREG-1536 [6.1.1], 10CFR72.124 [6.1.2],

and NUREG-0800 Section 9.1.2 [6.1.3], the results in this chapter demonstrate that the effective multiplication factor (keff) of the HI-STORM 100 System, including all biases and uncertainties evaluated with a 95% probability at the 95% confidence level, does not exceed 0.95 under all credible normal, off-normal, and accident conditions. Moreover, these results demonstrate that the HI-STORM 100 System is designed and maintained such that at least two unlikely, independent, and concurrent or sequential changes must occur to the conditions essential to criticality safety before a nuclear criticality accident is possible. These criteria provide a large subcritical margin, sufficient to assure the criticality safety of the HI-STORM 100 System when fully loaded with fuel of the highest permissible reactivity.

Criticality safety of the HI-STORM 100 System depends on the following four principal design parameters:

1. The inherent geometry of the fuel basket designs within the MPC (and the flux-trap water gaps in the MPC-24 and MPC-24E);
2. The incorporation of permanent fixed neutron-absorbing panels in the fuel basket structure;
3. An administrative limit on the maximum enrichment for PWR fuel and maximum planar-average enrichment for BWR fuel; and
4. An administrative limit on the minimum soluble boron concentration in the water for loading/unloading fuel with higher enrichments in the MPC-24 and MPC-24E, and for loading/unloading fuel in the MPC-32.

The off-normal and accident conditions defined in Chapter 2 and considered in Chapter 11 have no adverse effect on the design parameters important to criticality safety, and thus, the off-normal and accident conditions are identical to those for normal conditions.

The HI-STORM 100 System is designed such that the fixed neutron absorber will remain effective for a storage period greater than 620 years, and there are no credible means to lose it. Therefore, in accordance with 10CFR72.124(b), there is no need to provide a surveillance or monitoring program to verify the continued efficacy of the neutron absorber.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 16 REPORT HI-2002444 6-2 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-22

ATTACHMENT 1 TO HOLTEC LETTER 5014923 148 of 186 manufacturing tolerances are not assembly dependent, these dimensional assumptions were employed for the criticality analyses.

As demonstrated in this section, design parameters important to criticality safety are: fuel enrichment, the inherent geometry of the fuel basket structure, the fixed neutron absorbing panels and the soluble boron concentration in the water during loading/unloading operations. As shown in Chapter 11, none of these parameters are affected during any of the design basis off-normal or accident conditions involving handling, packaging, transfer or storage.

The MPC-32 criticality model uses a sheathing thickness of 0.075 inches, whereas the actual MPC-32 design uses a sheathing thickness of 0.035 inches. For the minimum cell pitch of 9.158 inches, the thicker sheathing results in a slightly smaller cell ID of 8.69 inches (minimum), compared to 8.73 inches (minimum) for the thinner sheathing. To demonstrate that the dimensions used in the criticality model are acceptable and conservative, calculations were performed for both sheathing thicknesses and the results are compared in Table 6.3.5. To bound various soluble boron levels, two comparisons were performed. The first comparison uses the bounding case for the MPC-32 (see Table 6.1.6), which is for assembly class 15x15F at 5 wt% 235U and a soluble boron level of 2600 ppm. To bound lower soluble boron levels, the second comparison uses the same assembly class (15x15F), 0 ppm soluble boron (i.e. pure water), and an arbitrary enrichment of 1.7 wt% 235U.

In both comparisons, the results of the 0.075 inch sheathing are slightly higher, i.e. more conservative, than the results for 0.035 inch sheathing, although the differences are within the statistical uncertainties. Using a sheathing thickness of 0.075 inches in the criticality models of the MPC-32 is therefore acceptable, and potentially more conservative, than using the actual value of 0.035 inches. This validates the choice of the dimensional assumptions for the MPC-32 shown in Table 6.3.3, which are used for all further MPC-32 criticality calculations, unless otherwise noted.

6.3.2 Cask Regional Densities Composition of the various components of the principal designs of the HI-STORM 100 System are listed in Table 6.3.4.

The HI-STORM 100 System is designed such that the fixed neutron absorber will remain effective for a storage period greater than 260 years, and there are no credible means to lose it. A detailed physical description, historical applications, unique characteristics, service experience, and manufacturing quality assurance of fixed neutron absorber are provided in Section 1.2.1.3.1.

The continued efficacy of the fixed neutron absorber is assured by acceptance testing, documented in Section 9.1.5.3, to validate the 10B (poison) concentration in the fixed neutron absorber. To demonstrate that the neutron flux from the irradiated fuel results in a negligible depletion of the poison material over the storage period, an MCNP4a calculation of the number of neutrons absorbed in the 10B was performed, and is shown in Subsection 3.4.12. The calculation HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 16 REPORT HI-2002444 6-89 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-23

ATTACHMENT 1 TO HOLTEC LETTER 5014923 149 of 186 conservatively assumed a constant neutron source for 50 years equal to the initial source for the design basis fuel, as determined in Section 5.2,, and shows that the fraction of 10B atoms destroyed is only 2.6E-09 in 50 years. Thus, the reduction in 10B concentration in the fixed neutron absorber by neutron absorption is negligible. In addition, the results presented in Subsection 3.4.4.3.1.8 demonstrate that the sheathing, which affixes the fixed neutron absorber panel, remains in place during all credible accident conditions, and thus, the fixed neutron absorber panel remains permanently fixed. Therefore, in accordance with 10CFR72.124(b), there is no need to provide a surveillance or monitoring program to verify the continued efficacy of the neutron absorber.

6.3.3 Eccentric Positioning of Assemblies in Fuel Storage Cells Up to and including Revision 1 of this FSAR, all criticality calculations were performed with fuel assemblies centered in the fuel storage locations since the effect of credible eccentric fuel positioning was judged to be not significant. Starting in Revision 2 of this FSAR, the potential reactivity effect of eccentric positioning of assemblies in the fuel storage locations is accounted for in a conservatively bounding fashion, as described further in this subsection, for all new or changed conditions. The calculations in this subsection serve to determine for which of these conditions the eccentric positioning of assemblies in the fuel storage locations results in a higher maximum keff value than the centered positioning. For the cases where the eccentric positioning results in a higher maximum keff value, the eccentric positioning is used for all corresponding cases reported in the summary tables in Section 6.1 and the results tables in Section 6.4. All other calculations throughout this chapter, such as studies to determine bounding fuel dimensions, bounding basket dimensions, or bounding moderation conditions, are performed with assemblies centered in the fuel storage locations.

To conservatively account for eccentric fuel positioning in the fuel storage cells, three different configurations are analyzed, and the results are compared to determine the bounding configuration:

  • Cell Center Configuration: All assemblies centered in their fuel storage cell; same configuration that is used in Section 6.2 and Section 6.3.1;
  • Basket Center Configuration: All assemblies in the basket are moved as close to the center of the basket as permitted by the basket geometry; and
  • Basket Periphery Configuration: All assemblies in the basket are moved furthest away from the basket center, and as close to the periphery of the basket as possible.

It should be noted that the two eccentric configurations are hypothetical, since there is no known physical effect that could move all assemblies within a basket consistently to the center or periphery. Instead, the most likely configuration would be that all assemblies are moved in the same direction when the cask is in a horizontal position, and that assemblies are positioned randomly when the cask is in a vertical position. Further, it is not credible to assume that any such HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 16 REPORT HI-2002444 6-90 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-24

ATTACHMENT 1 TO HOLTEC LETTER 5014923 150 of 186 6.6 REGULATORY COMPLIANCE This chapter documents the criticality evaluation of the HI-STORM 100 System for the storage of spent nuclear fuel. This evaluation demonstrates that the HI-STORM 100 System is in full compliance with the criticality requirements of 10CFR72 and NUREG-1536.

Structures, systems, and components important to criticality safety, as well as the limiting fuel characteristics, are described in sufficient detail in this chapter to enable an evaluation of their effectiveness.

The HI-STORM 100 System is designed to be subcritical under all credible conditions. The criticality design is based on favorable geometry and fixed neutron poisons (Boral). An appraisal of the fixed neutron poisons has shown that they will remain effective for a storage period greater than 620 years, and there is no credible way to lose it, therefore there is no need to provide a positive means to verify their continued efficacy as required by 10CFR72.124(b).

The criticality evaluation has demonstrated that the cask will enable the storage of spent fuel for a minimum of 620 years with an adequate margin of safety. Further, the evaluation has demonstrated that the design basis accidents have no adverse effect on the design parameters important to criticality safety, and therefore, the HI-STORM 100 System is in full compliance with the double contingency requirements of 10CRF72.124. Therefore, it is concluded that the criticality design features for the HI-STORM 100 System are in compliance with 10 CFR Part 72 and that the applicable design and acceptance criteria have been satisfied. The criticality evaluation provides reasonable assurance that the HI-STORM 100 System will allow safe storage of spent fuel.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Rev. 16 REPORT HI-2002444 6-165 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-25

ATTACHMENT 1 TO HOLTEC LETTER 5014923 151 of 186 Appendix 9.A Aging Management Program In accordance with the renewed HI-STORM 100 license, sites must implement an aging management program. An aging management assessment of the components of the HI-STORM 100 system was performed. This review identified inspection and monitoring activities necessary to provide reasonable assurance that system components within the scope of license renewal continue to perform their intended functions consistent with the current licensing basis for the renewed operating period. This section describes those aging management programs.

9.A.1 Aging Management Programs The following apply to Amendments 0 through 15.

9.A.1.1 MPC AMP The MPC AMP uses inspections to look for visual evidence of discontinuities and imperfects, such as localized corrosion, including pitting corrosion and stress corrosion cracking of the canister welds and heat affected zones. The full program is described in Table 9.A.1-1.

9.A.1.2 Overpack AMP The Overpack AMP uses inspections to look for indication of deterioration that might affect the ability of the overpack to perform its important to safety function. The full program is described in Table 9.A.1-2.

9.A.1.3 Transfer Cask AMP The Transfer Cask AMP utilizes inspections to ensure that the equipment maintains its intended function through the extended storage period. The full program is described in Table 9.A.1-3.

9.A.1.4 High Burnup Fuel Assembly AMP The high burnup fuel assembly AMP only applies to systems that store high burnup fuel. The AMP relies on the EPRI and DOE research project on high burnup fuel. The full program is described in Table 9.A.1-4.

9.A.1.5 100U Concrete AMP The 100U Concrete AMP only applies to sites that utilize the HI-STORM 100U system. The AMP uses condition monitoring to manage aging effects above and below ground. The full program is described in Table 9.A.1-5.

9.A.1.6 Time Limited Aging Analyses (TLAA)

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-1 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-26

ATTACHMENT 1 TO HOLTEC LETTER 5014923 152 of 186 During the review of the FSAR for license renewal, two time limited aging analyses (TLAAs) were identified that were updated to support the renewed license life. Full details of the analyses are contained in Reference [9.A.1].

  • Neutron Absorber Depletion - as described in Section 3.4.12, the calculation has been evaluated for the full 60 year license and demonstrates there is more than enough boron to account for any depletion so no aging management program is needed to manage the absorber aging.
  • MPC Fatigue Evaluation - A review of MPC fatigue indicated that repeated lifting cycles could change the fatigue life. The renewal application [9.A.1] indicates that the number of lifting cycles allowable is in excess of anything that would be expected for handling of the MPC throughout the extended storage period.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-2 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-27

ATTACHMENT 1 TO HOLTEC LETTER 5014923 153 of 186 Table 9.A.1-1 MPC AMP Element Description

1. Scope of Program This program covers MPCs stored under the HI-STORM 100 CoC, and the subcomponents identified in Table 3.3-1 of [9.A.1].
2. Preventative This AMP uses condition monitoring to manage aging effects.

Actions Preventative actions to minimize corrosion and stress corrosion cracking were taken during fabrication. Namely, stainless steel material was used to provide corrosion resistance, and fabrication controls were in place at the time of manufacture. These preventative actions minimize the likelihood of aging effects, but do not replace the need for condition monitoring during the extended storage period. Aging effects include loss of material due to localized corrosion, cracking due to fatigue and stress corrosion cracking, loss of material properties due to radiation and loss of strength due to thermal aging. No new preventative actions are included in this AMP.

3. Parameters The MPC AMP uses inspections as described below to look for visual Monitored / Inspected evidence of discontinuities and imperfections, such as localized corrosion, including pitting and crevice corrosion, and stress corrosion cracking of the accessible canister welds and weld heat affected zones.

The inspections also look for the appearance and location of deposits on the canister surfaces.

Inspections should also consider areas of canister where it is known that temporary supports or attachments were attached by welding and subsequently removed (based on available fabrication records).

4. Detection of Aging Visual Examination Effects A visual inspection of the MPC surface shall be performed using a boroscope (or equivalent). The boroscope (or equivalent) inspection shall look at the accessible areas of the MPC surface, while the MPC remains in the overpack with the overpack lid installed.

Visual examination procedures shallshould follow ASME Code Section XI, Article IWA-2200 for VT-1 and VT-3 examinations.

Additional assessment is necessary for suspected areas of localized corrosion and stress corrosion cracking. In these cases, the severity of the degradation shall be assessed, including the dimensions of the affected area and the depth of penetration with respect to the thickness of the canister. For accessible areas, remote visual examination meeting the requirements for ASME Code Section XI, IWA-2211 may be used to determine the type of degradation present (e.g., pitting corrosion or stress corrosion cracking)

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-3 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-28

ATTACHMENT 1 TO HOLTEC LETTER 5014923 154 of 186 Volumetric Examination Volumetric and surface examination methods are consistent with ASME Code XI, IWB-2500 shall be done to characterize the extent and severity of localized corrosion and stress corrosion cracking. Volumetric examination of pits and areas immediately adjacent to pits shall be done when pits are located within 25 mm (1 inch) of a through thickness weld or within 25 mm (1 inch) of an area where a temporary attachment was known to be located.

The inspection shall be site-specific and performed on a minimum of one canister at each site that uses the HI-STORM 100 System. Note that if a site has more than one type of canister (for example, MPC-68 and MPC-68Ms), the population should be treated as a whole. The selection criteria for choosing the canister/s to inspect and the determination of population size of canisters to inspect should consider the following:

  • EPRI Susceptibility Criteria (Technical Report 3002005371)
  • Canister Age
  • Canister with Lowest Heat Load
  • Canister with specific previously identified manufacturing deviation Inspection Frequency The inspection shall be performed by a qualified individual on one canister at a site at a frequency of 5 years (+/- 1.25 years). The first inspection shallshould occur prior to entering the period of extended operation within 365 days of the 20th anniversary of initial overpack loading at the site or no later thanwithin 365 days after the issuance of the renewed license, whichever is later. It is recommended that the same canister be used for each inspection to allow for the best continued monitoring and trending.

It is recommended that sites schedule the MPC inspection concurrently with the Overpack Interior Inspection for ALARA purposes.

At the discretion of the inspector, the inspection of selected areas on the MPC may be upgraded to the VT-1 standard, as described in ASME Section XI, Article IWA-2200, to the extent practical.

5. Monitoring and The documented inspection results should provide the ability to monitor HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-4 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-29

ATTACHMENT 1 TO HOLTEC LETTER 5014923 155 of 186 Trending and trend the appearance of the canister, it is recommended that the inspection video / photos be retained for comparison in subsequent examinations. Changes to the size and location of any areas of discoloration, localized corrosion, and/or stress corrosion cracking should be identified and documented for subsequent inspections.

6. Acceptance Inspection Results Requiring No Further Evaluation Criteria No indication of localized corrosion pits, etching, stress corrosion cracking, red-orange colored corrosion products in the vicinity of canister welds, closure welds and welds associated with temporary attachments during canister fabrication. Corrosion such as pitting requires additional evaluation.

Inspection Results Requiring Additional Evaluation Indications of interest in locations on the MPC susceptible to SCC-which include areas adjacent to fabrication welds, closure welds, locations where temporary attachments may have been welded to and subsequently removed from the MPC, and the weld affected zones that are subject to additional examination and disposition through the corrective action program include:

  • Discrete red-orange colored corrosion products especially those adjacent to fabrication welds, closure welds, locations where temporary attachments may have been welded to and subsequently removed from the MPC and the weld heat affected zones of these areas
  • Linear appearance of any color of corrosion products of any size parallel to or traversing fabrication welds, closure welds, and the weld heat affected zones of these areas.
  • Red-orange colored corrosion products greater than 1 mm in diameter combined with deposit accumulations in any location of the stainless steel canister
  • Red-orange colored corrosion tubercles of any size Alternatively, a general licensee may use acceptance criteria in an ASME Code for canister inspections that has been endorsed by the NRC.

If indications of localized or general corrosion, or stress corrosion cracking requiring additional evaluation are found, issue would be entered into the sites corrective action program and an engineering evaluation would be performed to determine the extent and impact of the corrosion on the components ability to perform its intended HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-5 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-30

ATTACHMENT 1 TO HOLTEC LETTER 5014923 156 of 186 function. These evaluations may include additional visual, surface, or volumetric non-destructive examination methods to determine the loss of material. If the degradation does not compromise the ability of the MPC to maintain its function, then no further evaluation is required but the degradation should be tracked for future inspections.

7. Corrective Actions The corrective actions performed based on any detected aging effects are in accordance with the sites Quality Assurance (QA) program. The QA Program ensures that corrective actions are completed.

The QA program and corrective action program will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable, as applicable.

The corrective actions will also identify any actions needed to be taken for increased sample size, scope, or frequency of inspections as necessary, based on any detected aging effects. ASME Code Case N-860 can be used for guidance on these corrective actions.

The corrective action program will also identify any dispositions needed from Holtec.

8. Confirmation The confirmation process will be commensurate with the site QA Process program. The QA program ensures that inspections, evaluations, and corrective actions are completed and extent of condition is considered.
9. Administrative The site QA program and implementing procedures for this AMP will Controls address instrument calibration and maintenance, inspector requirements, record retention requirements, and document control.

This AMP will be updated, as necessary, based on the toll gate assessments described in Section 4 of the renewal application [9.A.1].

Inspection results will be documented and made available for NRC inspection as necessary.

10. Operating Previous Operating Experience Experience No cases of chloride induced stress corrosion cracking for stainless steel dry storage canisters have been reported. Inspections of dry storage canisters after 20 years in service have been conducted at a few ISFSI sites [9.A.2C.1.1 and 9.A.3C.1.2]. No evidence of localized corrosion was identified but some amount of chloride-containing salts were determined to be present and corrosion products believed to be related to iron contamination were identified.

Section 3.1.2 of [9.A.1] summarizes HI-STORM 100 MPC operating HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-6 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-31

ATTACHMENT 1 TO HOLTEC LETTER 5014923 157 of 186 experience, which indicates very minimal corrosion detected to date.

Future Operating Experience As the MPC inspections are performed, sites will upload information into the INPO AMID database to be shared with other users.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-7 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-32

ATTACHMENT 1 TO HOLTEC LETTER 5014923 158 of 186 Table 9.A.1-2 Overpack AMP Element Description

1. Scope of Program This program covers the subcomponents of the HI-STORM 100 Overpack identified in Table 3.3-2 of [9.A.1], which require the Overpack AMP to ensure their continued operation into the extended storage period. The AMP has two main parts: one for the internal areas and one for the external areas of the cask.
2. Preventative This AMP uses condition monitoring to manage aging effects. The Actions design of the system is intended to minimize aging effects, but this AMP focuses on condition monitoring and detecting any evidence of degradation. No new preventative actions are included in this AMP.
3. Parameters The inspections shall be site-specific and performed at sites which Monitored / Inspected utilize HI-STORM 100 systems. Visual inspections cover all of normally accessible surfaces of the overpack including the external and internal surfaces.

Overpack External Normally accessible portions of the overpack are visually examined for indication of surface deterioration. Degradation could affect the ability of the overpack to provide support to the MPCs, to provide radiation shielding, to provide missile shielding, or to provide a path for heat transfer. The items inspected should cover (but are not limited to) those listed below:

  • Lid studs and nuts or lid closure bolts, as accessible
  • The accessible overpack body and lid painted surfaces
  • Vents
  • Anchor hardware, if used Overpack Internal Normally accessible internal surfaces of the overpack are inspected for indications of corrosion and coating degradation. These indications may impact the long term ability of the cask to meet its intended function.
4. Detection of Aging Overpack External Effects The overpack external AMP is a visual inspection in order to detect any aging effects. The visual survey performed on all overpacks annually will identify the source of any staining or corrosion-related activity and the degree of damage. The visual survey is performed in accordance with site implementing procedures, and may be satisfied by continuing the overpack external surface (accessible) visual examination in the HI-STORM FSAR Table 9.2.1. The ISFSI pad concrete portions adjacent to overpack shall be inspected visually for any evidence of degradation HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-8 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-33

ATTACHMENT 1 TO HOLTEC LETTER 5014923 159 of 186 (such as staining or rust) to determine if normally inaccessible components located in the overpack internal (i.e., container shell bottom plate, cask bottom) need additional inspection.

Overpack Internal A visual inspection of the overpack annular space and the interior areas of the vents shall be performed using a boroscope (or equivalent). This visual inspection shall meet the requirements of a VT-3 Examination, as given in the ASME Boiler & Pressure Vessel Code (B&PVC)Section XI, Article IWA-2200, to the extent practical.

The internal inspection shall be performed on one overpack at each site at a frequency of 5 years (+/- 1.25 years). The first inspection shallshould occur within 365 days of the 20th anniversary of initial overpack loading at the site prior to entering the period of extended operation or no later than within 365 days after the issuance of the renewed license, whichever is later. For ALARA reasons, it is recommended that the site use the overpack that contains the MPC used for the MPC AMP.

The inspection shall be documented, including a detailed description of the surface condition and location of areas showing surface degradation.

5. Monitoring and The inspections and surveillances described for both the internal and Trending external subcomponents of the overpack are performed periodically in order to identify areas of degradation. The results will be evaluated by a qualified individual, and areas of degradation not meeting established criteria will be entered into the corrective action program for resolution or more detailed evaluation. The results will be compared against previous inspections in order to monitor and trend the progression of the aging effects over time.
6. Acceptance Overpack External Criteria The external metallic surfaces of the overpack are coated, and significant corrosion is not anticipated. Vents shall be free from obstructions. Overpack lid shall be free of dents, scratches, gouges or other damage. Gouges and depressions that are less than 25% of the thickness, less than 20% of the largest lineal dimension of the part lengthong, less than 1/4 inch width, with a minimum separation between gouges of 5% of the largest lineal dimension of the part are considered acceptable without further evaluation. Gouges of this size were considered acceptable without further evaluation during fabrication, and continue to be acceptable during storage.

The area of ISFSI pad concrete adjacent to the overpack shall not show HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-9 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-34

ATTACHMENT 1 TO HOLTEC LETTER 5014923 160 of 186 any evidence of corrosion such as rust.

Any indications of general or localized corrosion (pitting and crevice) on the steel surfaces, or degradation of coatings shall be identified for trending purposes. If indications requiring additional evaluation are found, issue would be entered into the sites corrective action program and an engineering evaluation would be performed to determine the extent and impact of the degradation on the components ability to perform its intended function. These evaluations may include additional visual, surface, or volumetric non-destructive examination methods to determine the loss of material. If the degradation does not compromise the ability of the overpacks ability to maintain its function, then no further evaluation is required but the degradation should be tracked for future inspections.

Overpack Internal The internal metallic surfaces of the overpack are coated, and significant corrosion is not anticipated.

Any indications of general or localized corrosion (pitting and crevice) on the steel surfaces, or degradation of coatings shall be identified for trending purposes. If indications requiring additional evaluation are found, issue would be entered into the sites corrective action program and an engineering evaluation would be performed to determine the extent and impact of the degradation on the components ability to perform its intended function. These evaluations may include additional visual, surface, or volumetric non-destructive examination methods to determine the loss of material. If the degradation does not compromise the ability of the overpacks ability to maintain its function, then no further evaluation is required but the degradation should be tracked for future inspections.

7. Corrective Actions The corrective actions performed based on any detected aging effects are in accordance with the sites Quality Assurance (QA) program. The QA Program ensures that corrective actions are completed.

The QA program and corrective action program will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable, as applicable.

The corrective actions will also identify any actions needed to be taken for increased scope or frequency of inspections as necessary, based on any detected aging effects.

The corrective action program will also identify any dispositions needed from Holtec. If significant exterior corrosion is found in the area, one HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-10 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-35

ATTACHMENT 1 TO HOLTEC LETTER 5014923 161 of 186 potential corrective action could be to perform additional inspections of inaccessible surfaces, such as bottom of the cask.

8. Confirmation The confirmation process will be commensurate with the site QA Process program. The QA program ensures that inspections, evaluations, and corrective actions are completed.
9. Administrative The site QA program and implementing procedures for this AMP will Controls address instrument calibration and maintenance, inspector requirements, record retention requirements, and document control.

This AMP will be updated, as necessary, based on the toll gate assessments described in Section 4 of the renewal application [9.A.1].

Inspection results will be documented and made available for NRC inspection as necessary.

10. Operating Previous Operating Experience Experience Section 3.1.2 of the renewal application [9.A.1] summarizes HI-STORM 100 operating experience, which indicates very minimal corrosion detected to date, mostly limited to small rust spots and coating degradation. That operating experience has been incorporated into the guidance on inspections and acceptance criteria contained in this AMP.

Future Operating Experience As the overpack inspections are performed, sites will upload information into the INPO AMID database to be shared with other users.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-11 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-36

ATTACHMENT 1 TO HOLTEC LETTER 5014923 162 of 186 Table 9.A.1-3 Transfer Cask AMP Element Description

1. Scope of Program The program covers the subcomponents of the Transfer Cask identified in Table 3.3-5 of [9.A.1] which require the Transfer Casks AMP, to operate into the extended storage period.
2. Preventative The Transfer Cask AMP utilizes inspections to ensure that the Actions equipment maintains its intended function through the extended storage period. The design and materials of construction of the Transfer Cask were implemented to minimize aging effects, but no new preventative actions are included as part of this AMP.
3. Parameters This program monitors the condition of internal and external steel Monitored / Inspected surfaces of all the transfer casks to identify general, pitting, crevice, and galvanic corrosion, and wear. The parameter inspected by the Transfer Cask AMP is visual evidence of degradation of external surfaces of the Transfer Cask and trunnions.

The condition of inaccessible steel internal surfaces that are continuously or intermittently exposed to a liquid neutron shield are monitored from the external side of the shield shell. Fatigue analysis for the trunnions is provided in Appendix B of this renewal application.

Parameter monitored or inspected for accessible surfaces include:

  • Visual evidence of surface discontinuities and imperfections indicative of corrosion
  • Visual evidence of coating degradation (e.g., blisters, cracking, flaking, delamination) indicative of corrosion of the base metal.

Parameters monitored or inspected to evaluate inaccessible steel surfaces exposed to a liquid neutron shield include:

  • Visual evidence of leakage on external surfaces
4. Detection of Aging The Transfer Cask AMP manages loss of material due to corrosion and Effects wear, predominately for coated steel components.

Visual inspections of the normally accessible surfaces are performed in accordance with the ASME Code Section XI, Article IWA-2213, for VT-3 examinations. The inspections shall cover all of the normally accessible surfaces, including the cask exterior surfaces, cask interior cavity, lid surfaces, and the cask bottom (during lifting or down ending).

For normally inaccessible internal surfaces (i.e., liquid neutron shield),

the condition of the neutron shield shell surfaces shall be monitored by inspections for leakage when the shield is filled with water, following ASME Code Section XI, Article IWA-2212, VT-2 (visual) inspection HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-12 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-37

ATTACHMENT 1 TO HOLTEC LETTER 5014923 163 of 186 requirements.

The inspection shall be performed prior to use of any Transfer Cask that has been in service longer than 20 years (or prior to the first use after the renewed license is issued, whichever is later) and at a minimum once a year while in use. Because the Transfer Cask is not used while loadings and unloadings are not occurring, pre-use inspections are most appropriate for the Transfer Cask. Periodic inspections when the Transfer Cask is not in use are not needed.

5. Monitoring and Visual inspections will determine the existence of loss of material on the Trending external surfaces of the Transfer Cask, and observations regarding the material condition are recorded in accordance with inspection procedures and are corrected or evaluated as satisfactory before use of the Transfer Cask.

Evaluation of this information during the preparations for MPC transfers provides adequate predictability and allows for corrective actions if necessary, prior to the need for the intended function of the component to be performed.

6. Acceptance The Transfer Cask AMP consists of visual inspections as described Criteria above.

The following results do not require further evaluation

  • All painted surfaces shall be free of degradation and chipped, cracked, or blistered paint
  • All lid surfaces shall be free of dents, scratches, gouges, or other damage. Gouges and depressions that are less than 25% of the thickness, less than 20% of the largest lineal dimension of the part lengthong, less than 1/4 inch width, with a minimum separation between gouges of 5% of the largest lineal dimension of the part are considered acceptable without further evaluation.

Gouges of this size were considered acceptable without further evaluation during fabrication, and continue to be acceptable during extended operation.

  • Lifting trunnions shall be free of deformation, cracks, damage, wear, general and localized corrosion
  • The water jacket shall be free of leaks
  • All other accessible surfaces shall be free of dents, scratches, gouges, or other damage If evidence of corrosion, wear or coating degradation are identified, then the severity of degradation of the base metal shall be determined and the issue shall be entered into the sites corrective action program and an HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-13 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-38

ATTACHMENT 1 TO HOLTEC LETTER 5014923 164 of 186 engineering evaluation shall be performed to determine the extent and impact of the corrosion or wear on the Transfer Casks ability to perform its intended function. These additional evaluations may include additional visual, surface, or volumetric non-destructive examination methods to determine the loss of material.

For inaccessible internal surfaces, the acceptance criteria are no evidence of leakage of the water neutron shield.

7. Corrective Actions If the engineering evaluation described above shows that the Transfer Cask has indications that exceed acceptable limits for the Transfer Cask to perform its intended function, the issue will be entered into the corrective action process. This process may result in supplemental inspections such as non-destructive examinations (NDE) being performed.

The corrective action program will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable, as applicable.

The corrective actions will also identify actions needed for increased scope or frequency of inspections, as necessary, based on any detected aging effects.

8. Confirmation The confirmation process will be commensurate with the site QA Process program. The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the program.
9. Administrative The QA program and implementing procedures for this AMP will Controls address instrument calibration and maintenance, inspector requirements, record retention requirements, and document control.

This AMP will be updated, as necessary, based on the toll gate assessments described in Section 4 of the renewal application [9.A.1].

Inspection results will be documented and made available for NRC inspection as necessary.

10. Operating Previous Operating Experience Experience Section 3.1.2 of the renewal application [9.A.1] summarizes HI-STORM 100 operating experience, which indicates very minimal corrosion detected to date, mostly limited to coating degradation. That operating experience has been incorporated into the guidance on inspections and acceptance criteria contained in this AMP.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-14 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-39

ATTACHMENT 1 TO HOLTEC LETTER 5014923 165 of 186 Future Operating Experience As the transfer cask inspections are performed, sites will upload information into the INPO AMID database to be shared with other users HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-15 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-40

ATTACHMENT 1 TO HOLTEC LETTER 5014923 166 of 186 Table 9.A.1-4 High Burnup Fuel Assembly AMP Element Description

1. Scope of Program The scope of the program covers the components identified in Table 3.3-4 of [9.A.1] which require the High Burnup Fuel Assembly AMP, to operate into the extended storage period.

This program is not applicable at sites that do not have high burnup fuel stored.

Fuel stored in the HI-STORM 100 MPCs is limited to a burnup of 68,200 MWD/MTU (PWR) and 65,000 MWD/MTU (BWR). The cladding materials for the high burnup fuel are zirconium based and the fuel is stored in a dry helium environment.

The program relies on the joint EPRI and DOE High Burnup Dry Storage Cask Research and Development Project (HDRP) conducted in accordance with the guidance in Appendix D of NUREG-1927, Rev 1, as a surrogate demonstration program that monitors the performance of high burnup fuel in dry storage.

The HDRP is a program designed to collect data from an SNF storage system containing high burnup fuel in a dry helium environment. The program entails loading and storing a bolted lid cask (the Research Project Cask), with intact high burnup fuel of nominal burnups between 53 GWd/MTU and 58 GWD/MTU. The fuel to be used in the program includes four kinds of zirconium based cladding. The Research Project Cask is to be licensed to the temperature limits contained in ISG-11 Rev 3, and is loaded to reach temperatures as close to the limit as practicable.

The parameters of the surrogate demonstration program are applicable to the HI-STORM 100 high burnup fuel, since the system burnup limits are approximately those being tested, the cladding is of the same type as those being tested, and the temperature limits of the fuel are the same as those being tested.

2. Preventative During the initial loading operations of the HI-STORM 100 system, the Actions technical specifications require that the fuel be stored in a dry, inert environment. These requirements ensure that the high burnup fuel is stored in an inert environment, preventing cladding degradation due to oxidation mechanisms. The canisters are also loaded in accordance with HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-16 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-41

ATTACHMENT 1 TO HOLTEC LETTER 5014923 167 of 186 the temperature criteria of ISG-11, which minimizes the impacts of degradation mechanisms on the fuel. There are no additional specific preventative actions included as part of the AMP.

3. Parameters The surrogate demonstration program monitors and inspects fuel Monitored / Inspected parameters as described in the HDRP.
4. Detection of Aging The surrogate demonstration program detects aging effects as described Effects in the HDRP.
5. Monitoring and As information / data from the HDRP become available, the site will Trending monitor, evaluate, and trend the information via its operating experience program and /or corrective action program to determine what actions should be taken.

The site will evaluate the information / data from the HDRP to determine whether the acceptance criteria in Element 6 of this AMP are met.

  • If all of the acceptance criteria are met, no further assessment is needed.
  • If any of the acceptance criteria are not met, the licensee must conduct additional assessments and implement appropriate corrective actions (see Element 7 of this AMP).

Note that the site may use evaluations/assessments provided by Holtec to determine whether the acceptance criteria are met.

Formal evaluations of the aggregate information from the HDRP, available operating experience, NRC-generated communications, and other information will be performed at specific points as described in Chapter 4 of the renewal application [9.A.1].

6. Acceptance The HDRP acceptance criteria are:

Criteria

  • Hydrogen content - Maximum hydrogen content of the cover gas over the approved storage period should be extrapolated from the gas measurements to be less than the design-bases limit for hydrogen content
  • Moisture content - The moisture content in the canister (accounting for measurement uncertainty) should be less than the expected upper-moisture content per the design-bases drying process (with appropriate consideration for the differences in design/acceptance criteria between the demo cask and the HI-STORM 100). The drying criteria for the MPC is provided in HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-17 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-42

ATTACHMENT 1 TO HOLTEC LETTER 5014923 168 of 186 Table 2.0.1 and Section 8.1 of this FSAR.

  • Fuel condition / performance - nondestructive and destructive examinations should confirm the design-bases fuel condition (i.e., no changes to the analyzed fuel configuration considered in the safety analyses of the approved design bases Note that because the cask design to be used in the HDRP is different from the HI-STORM 100, the acceptance criteria will be based on the Research Cask design bases. If the fuel in the Research Cask meets the applicable design bases, the fuel in the HI-STORM 100 should also meet its design bases, as described in Element 1.
7. Corrective Actions If the acceptance criteria described above are not met, the issue will be entered into the corrective action process.

The corrective action program will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable, as applicable.

The corrective actions will also identify actions needed for increased scope or frequency of inspections, as necessary, based on any detected aging effects.

8. Confirmation The confirmation process will be commensurate with the site QA Process program. The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the program.
9. Administrative The QA program and implementing procedures for this AMP will Controls address record retention requirements and document control.

This AMP will be updated, as necessary, based on the toll gate assessments described in Section 4 of the renewal application [9.A.1].

Inspection results will be documented and made available for NRC inspection as necessary.

10. Operating Future Operating Experience Experience As the HDRP continues information will be uploaded into the INPO AMID database HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-18 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-43

ATTACHMENT 1 TO HOLTEC LETTER 5014923 169 of 186 Table 9.A.1-5 100U Concrete AMP Element Description

1. Scope of The program covers the 100U concrete identified in Table 3.3-2 of [9.A.1]

Program which require the 100U Concrete AMP. The scope covers inspections of the above-grade areas of the ISFSI pad which are readily accessible and monitoring for the below grade portions exposed to sub grade (soil),

backfill, or groundwater per the requirements described in ACI 349.3R-02.

Groundwater chemistry program is utilized to identify conditions conducive to aging of below-grade portions. Radiation surveys shall be done to monitor the shielding performance of the HI-STORM 100U system.

2. Preventive This AMP uses condition monitoring to manage aging effects. The design Actions of the system is intended to minimize aging effects, but this AMP focuses on condition monitoring. No new preventive actions are included in this AMP.
3. Parameters The accessible and exposed surfaces are visually examined for indication Monitored / of surface deterioration. Degradation could affect the ability of the Inspected concrete to provide support to the VVMs, to provide radiation shielding, to provide missile shielding, or to provide a path for heat transfer. The inlet and outlet vents are monitored by visual inspection to ensure they are not obstructed.

Below-grade concrete portions exposed to soil environments are monitored in accordance with ACI 349.3R-02.

The external soil/groundwater environment in contact with the concrete may possess and develop aging mechanisms that can expose the concrete to an environment that could precipitate the aging mechanisms listed in Table 3.3.2. To help monitor the condition of below-grade concrete by sampling its surrounding environment, a groundwater chemistry program to include groundwater chemistry sampling shall be performed every 5 years. This groundwater chemistry examination shall be used to characterize environmental exposure conditions and their potential effects to evaluate their propensity to cause concrete degradation. For inaccessible areas, groundwater monitoring is performed every 5 years to determine if any degradation from the inaccessible portions is occurring. The Groundwater chemistry program is utilized to identify conditions conducive to the following below-grade aging mechanisms:

  • Corrosion of embedded steel
  • Chemical attack (chloride and sulfate-induced degradation)

Any surface geometries that may support water ponding may potentially increase the rate of degradation. For groundwater chemistry program, the HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-19 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-44

ATTACHMENT 1 TO HOLTEC LETTER 5014923 170 of 186 parameters monitored or inspected include:

  • pH of water
  • Concentration of chlorides and sulfates in the water For radiation surveys, the parameters monitored include the gamma dose rate and neutron fluence.
4. Detection of The AMP is a visual inspection of readily accessible surfaces of the ISFSI Aging Effects pad in order to detect any aging effects. These visual inspections cover all of the readily accessible surfaces of the ISFSI pad and are conducted every 5 years. The visual survey will identify the source of any staining or corrosion-related activity and the degree of damage. This visual inspection identifies the current condition of the structure and can identify the extent and cause of any aging effect noted. This visual inspection is conducted every 5 yearsannually by an individual meeting the qualification requirements of per ACI-349.3R-02, and includes all accessible areas on the pad. Settlement of the pad will be confirmed to be within the design basis using methodology from ACI349.3R-02. Visual inspections of the below-grade areas are performed on an opportunistic basis, only when excavations in the area occur.

Groundwater chemistry monitoring shall be performed every 5 years to determine if any degradation of the system from inaccessible areas is occurringdetect any potential corrosive environment that might cause concrete degradation. Radiation surveys shall be done every five years to monitor the dose rates HI-STORM 100U system.

Data from all inspection and monitoring activities, including evidence of degradation and its extent and location, shall be documented on a checklist or inspection form. The results for the inspection will be documented, including descriptions of observed aging effects and supporting sketches, photographs or video.

5. Monitoring and Monitoring and trending methods are commensurate with consensus defect Trending evaluation guides and standards. These may include standards such as ACI 201.1R, ACI 207.3R, ACI 364.1R, ACI 562, or ACI 224.1R, as applicable.

The inspections and surveillances described for reinforced concrete are performed periodically in order to identify areas of degradation. The results will be evaluated by a qualified individual, and areas of degradation not meeting established criteria will be entered into the sites CAP for resolution or more detailed evaluation. The results from the visual inspection, radiation survey, and groundwater monitoring will be compared against previous inspections in order to monitor and trend the progression of the aging effects over time.

6. Acceptance American Concrete Institute Standard 349.3R-02 includes quantitative HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-20 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-45

ATTACHMENT 1 TO HOLTEC LETTER 5014923 171 of 186 Criteria three-tier acceptance criteria for visual inspections of concrete surfaces, namely (1) acceptance without further evaluation, (2) acceptance after review, and (3) acceptance requiring further evaluation. Acceptable signifies that a component is free of significant deficiencies or degradation that could lead to the loss of structural integrity. Acceptable after review signifies that a component contains deficiencies or degradation but will remain able to perform its design basis function until the next inspection or repair. Acceptance requiring further evaluation signifies that a component contains deficiencies or degradation that could prevent (or could prevent prior to the next inspection) the ability to perform its design basis function.

Degradations or conditions meeting the ACI349.3R-02 Tier 2 and 3 criteria will be entered into the sites CAP for evaluation and resolution.

The loss of material due to age-related degradation of ISFSI pad subcomponents will be evaluated by a qualified person in accordance with ACI 349.3R-02. A technical basis will be provided for any deviation from ACI349.3R-02 acceptance criteria.

The acceptance criteria for the groundwater chemistry program are commensurate with ASME Code Section XI, Subsection IWL, which states that an aggressive below-grade environment is defined as pH < 5.5, chlorides > 500 ppm, or sulfates > 1500 ppm. Failure to meet the acceptance criteria for the groundwater chemistry program will need further evaluation to determine condition of the neighboring below-grade structures. Any groundwater indications of concrete degradation will be entered into the corrective action program.

The acceptance criteria for radiation surveys are dose rates that are less than a 10% increase from the previously measured dose rates.

The radiation survey is to be taken 1 m from the VVM inlet vent (see dose point location 1 that is1 meter adjacent to the VVM inlet vent for the reference in Figure 5.I.1 of the HI-STORM 100 FSAR). The first inspection in the period of extended operation shall be considered as the baseline measurement. The acceptance criteria for the radiation surveys are:

1. Baseline radiation survey measurements shall be lower than the dose measurements taken at the time of cask loading.
2. Dose measurements for all subsequent radiation surveys shall be less than the baseline radiation survey dose rate measurement.
7. Corrective Corrective actions performed based on unacceptable effects will be in Actions accordance with the ISFSI Quality Assurance (QA) program. The QA HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-21 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-46

ATTACHMENT 1 TO HOLTEC LETTER 5014923 172 of 186 Program ensures that corrective actions are completed within the ISFSI Corrective Action Program (CAP).

As applicable per the CAP program, ISFSI staff will determine any necessary actions, identify any changes to the existing AMP, and determine if the condition is reportable.

Corrective actions will also identify the actions needed for increased scope or frequency of inspections, as necessary, based on any detected aging effects.

8. Confirmation The confirmation process will be commensurate with the ISFSI QA Process Program. The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the ISFSI CAP.
9. Administrative The ISFSI QA program and implementing procedures for this AMP will Controls address instrument calibration and maintenance, inspector requirements, record retention requirements (commensurate with ACI 349.3R-02), and document control.

This AMP will be updated periodically, as necessary, based on the tollgate assessments described in Chapter 4 of the renewal application [9.A.1].

Inspection results will be documented and made available for NRC inspectors to view upon request.

10. Operating The ISFSI pad will be inspected before the CEC is placed in accordance Experience with existing operating procedures. The overall effectiveness of these inspections in maintaining the condition and functionality of the ISFSI Pad.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-22 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-47

ATTACHMENT 1 TO HOLTEC LETTER 5014923 173 of 186 9.A.2 Tollgates Tollgates are established as requirements in the renewed CoC, and implemented by ISFSI generic licensees to evaluate aging management feedback and perform a safety assessment that confirms the safe storage of spent nuclear fuel. The impact of the aggregate feedback will be assessed by the site as it pertains to components at the sites ISFSI and actions taken as necessary, such as:

  • Adjustment of aging-related degradation monitoring and inspection programs in AMPs
  • Performance of mitigation activities Each tollgate assessment will address the following elements as applicable:
  • Summary of research findings, operating experience, monitoring data, and inspection results made available since last assessment
  • Aggregate impact of findings, including any trends
  • Consistency of data with the assumptions and inputs in the TLAAs
  • Effectiveness of AMPs
  • Corrective actions, including any changes to AMPs
  • Summary and conclusions A schedule for these tollgate assessments is shown in Table 9.A.2-1.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-23 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-48

ATTACHMENT 1 TO HOLTEC LETTER 5014923 174 of 186 Table 9.A.2-1: Tollgate Assessments for General Licensees Tollgate Year Assessment 1 Year of first Evaluate information from the following sources (as available) and canister loading + perform a written assessment of the aggregate impact of the information, 25 years including but not limited to trends, corrective actions required, and the effectiveness of the AMPs with which they are associated:

  • Results, if any, of research and development programs focused specifically on aging-related degradation mechanisms identified as potentially affecting the storage system and ISFSI site. One example of such research and development would be EPRI Chloride-Induced Stress Corrosion Cracking (CISCC) research.
  • Relevant results of other domestic and international research, which may include non-nuclear research
  • Relevant domestic and international operating experience, which may include non-nuclear operating experience
  • Relevant results of domestic and international ISFSI and dry storage system performance monitoring Much of this information can be gathered from the Aging Management INPO Database (AMID).

2 Year of first Evaluate additional information gained from the sources listed in canister loading + Tollgate 1 along with any new relevant sources and perform a written 30 years assessment of the aggregate impact of the information. This evaluation should be informed by the results of Tollgate 1. The aging effects and mechanisms evaluated at this tollgate and the time at which it is conducted may be adjusted based on the results of the Tollgate 1 assessment.

3 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1 and 2 canister loading +

35 years 4 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, and 3 canister loading +

40 years 5 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, and 4 canister loading +

45 years 6 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, and canister loading + 5 50 years 7 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, 5, canister loading + and 6 55 years 8 Year of first Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, 5, 6, canister loading + and 7 60 years HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-24 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-49

ATTACHMENT 1 TO HOLTEC LETTER 5014923 175 of 186 9.A.3 References

[9.A.1] HI-2188877, HI-STORM 100 License Renewal Application, Latest RevisionRevision 1.

[9.A.2] HI-2146300, MPC Surface Inspection at Hope Creek Nuclear Generating Station, Revision 1, May 8, 2015.

[9.A.3] HI-2146301, MPC Surface Inspection at Diablo Canyon Power Plant, Revision 09-2, May 8, 2015.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-STORM 100 FSAR Proposed Rev. 197 REPORT HI-2002444 9.AIII-25 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 D-50

ATTACHMENT 1 TO HOLTEC LETTER 5014923 176 of 186 APPENDIX E: AGING MANAGEMENT CoC CHANGES The proposed changes to the HI-STORM 100 CoC as a result of the renewal are shown in the attached. Note that they are only applied to the Amendment 15 CoC for convenience, but the same changes will be applied to all amendments being renewed.

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188877 Rev. 10A E-1

NRC FORM 651 ATTACHMENT 1 TO HOLTEC LETTER 5014923 177 of 186 U.S. NUCLEAR REGULATORY COMMISSION (10-2004) 10 CFR 72 CERTIFICATE OF COMPLIANCE FOR SPENT FUEL STORAGE CASKS Page 1 of 5 The U.S. Nuclear Regulatory Commission is issuing this Certificate of Compliance pursuant to Title 10 of the Code of Federal Regulations, Part 72, "Licensing Requirements for Independent Storage of Spent Nuclear Fuel and High-Level Radioactive Waste" (10 CFR Part 72). This certificate is issued in accordance with 10 CFR 72.238, certifying that the storage design and contents described below meet the applicable safety standards set forth in 10 CFR Part 72, Subpart L, and on the basis of the Final Safety Analysis Report (FSAR) of the cask design. This certificate is conditional upon fulfilling the requirements of 10 CFR Part 72, as applicable, and the conditions specified below.

Certificate No. Effective Expiration Docket No. Amendment No. Amendment Effective Date Package Identification No.

Date Date 1014 05/31/00 05/31/20 72-1014 15 TBD USA/72-1014 Renewed Renewed Revision No. Revision Effective Date Effective Expiration Date Date 0 NA TBD TBD Issued To: (Name/Address)

Holtec International Holtec Technology Campus One Holtec Blvd Camden, NJ 081074 Safety Analysis Report Title Holtec International Inc.,

Final Safety Analysis Report for the HI-STORM 100 Cask System CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 72, as applicable, the attached Appendix A (Technical Specifications) and Appendix B (Approved Contents and Design Features) for aboveground systems except Version E, HI-TRAC MS, MPC-32M, and Version 1 of MPC-32 and MPC-68; the attached Appendix C (Technical Specifications) and Appendix D (Approved Contents and Design Features) for the HI-STORM 100S Version E, HI-TRAC MS, MPC-32M, and Version 1 of MPC-32 and MPC-68M; or the attached Appendix A-100U (Technical Specifications) and Appendix B-100U (Approved Contents and Design Features) for underground systems, and the conditions specified below:

1. CASK
a. Model No.: HI-STORM 100 Cask System The HI-STORM 100 Cask System (the cask) consists of the following components: (1) interchangeable multi-purpose canisters (MPCs), which contain the fuel; (2) a storage overpack (HI-STORM), which contains the MPC during storage; and (3) a transfer cask (HI-TRAC), which contains the MPC during loading, unloading and transfer operations. The cask stores up to 32 pressurized water reactor fuel assemblies or 68 boiling water reactor fuel assemblies.
b. Description The HI-STORM 100 Cask System is certified as described in the Final Safety Analysis Report (FSAR) and in the U.S. Nuclear Regulatory Commissions (NRC) Safety Evaluation Report (SER) accompanying the Certificate of Compliance (CoC). The cask comprises three discrete components: the MPC, the HI-TRAC transfer cask, and the HI-STORM storage overpack.

The MPC is the confinement system for the stored fuel. It is a welded, cylindrical canister with a honeycombed fuel basket, a baseplate, a lid, a closure ring, and the canister shell. All MPC components that may come into contact with spent fuel pool water or the ambient environment are made entirely of stainless steel or passivated aluminum/aluminum alloys such as the neutron absorbers. The canister shell, baseplate, lid, vent and drain port cover plates, and closure ring are the main confinement boundary components. All confinement boundary components are made entirely of stainless steel. The honeycombed basket, which contains neutron absorbing material, provides criticality control.

HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-2

ATTACHMENT 1 TO HOLTEC LETTER 5014923 178 of 186 NRC FORM 651 U.S. NUCLEAR REGULATORY COMMISSION (3-1999) 10 CFR 72 CERTIFICATE OF COMPLIANCE Certificate No. 1014 FOR SPENT FUEL STORAGE CASKS Amendment No. 15 Supplemental Sheet Page 2 of 5

1. b. Description (continued)

There are twelve types of MPCs: the MPC-24, MPC-24E, MPC-24EF, MPC-32, MPC-32F, MPC-32 Version 1, MPC-32M, MPC-68, MPC-68 Version 1, MPC-68F, MPC-68FF, and MPC-68M. The number suffix indicates the maximum number of fuel assemblies permitted to be loaded in the MPC. All nine MPC models have the same external diameter.

The HI-TRAC transfer cask provides shielding and structural protection of the MPC during loading, unloading, and movement of the MPC from the spent fuel pool to the storage overpack. The transfer cask is a multi-walled (carbon steel/lead/carbon steel) cylindrical vessel with a neutron shield jacket attached to the exterior.

All transfer cask sizes have identical cavity diameters. The higher weight HI-TRAC transfer casks have thicker shielding and larger outer dimensions than the lighter HI-TRAC transfer casks.

Above Ground Systems The HI-STORM 100 or 100S storage overpack provides shielding and structural protection of the MPC during storage. The HI-STORM 100S is a variation of the HI-STORM 100 overpack design. The overpack is a heavy-walled steel and concrete, cylindrical vessel. Its side wall consists of plain (un-reinforced) concrete that is enclosed between inner and outer carbon steel shells. The overpack has air vents at the bottom and at the top to allow air to circulate naturally through the cavity to cool the MPC inside. A loaded MPC is stored within the HI-STORM 100 or 100S storage overpack in a vertical orientation. The HI-STORM 100A and 100SA are variants of the HI-STORM 100 family and are outfitted with an extended baseplate and gussets to enable the overpack to be anchored to the concrete storage pad in high seismic applications. The Version E can be arrayed in a free standing or anchored configuration Underground Systems The HI-STORM 100U System is an underground storage system identified with the HI-STORM 100 Cask System. The HI-STORM 100U storage Vertical Ventilated Module (VVM) utilizes a storage design identified as an air-cooled vault or caisson. The HI-STORM 100U storage VVM relies on vertical ventilation instead of conduction through the soil, as it is essentially a below-grade storage cavity. Air inlets and outlets allow air to circulate naturally through the cavity to cool the MPC inside. The subterranean steel structure is seal welded to prevent ingress of any groundwater from the surrounding subgrade, and it is mounted on a stiff foundation.

The surrounding subgrade and a top surface pad provide significant radiation shielding. A loaded MPC is stored within the HI-STORM 100U storage VVM in the vertical orientation.

2. OPERATING PROCEDURES Written operating procedures shall be prepared for cask handling, loading, movement, surveillance, and maintenance. The users site-specific written operating procedures shall be consistent with the technical basis described in Chapter 8 of the FSAR.
3. ACCEPTANCE TESTS AND MAINTENANCE PROGRAM Written cask acceptance tests and maintenance program shall be prepared consistent with the technical basis described in Chapter 9 of the FSAR. At completion of welding the MPC shell to baseplate, an MPC confinement weld helium leak test shall be performed using a helium mass spectrometer. This test shall include the base metals of the MPC shell and baseplate. A helium leak test shall also be performed on the base metal of the fabricated MPC lid. In the field, a helium leak test shall be performed on the vent and drain port confinement welds and cover plate base metal. The confinement boundary leakage rate tests shall be performed in accordance with ANSI N14.5 to leaktight criteria. If a leakage rate exceeding the acceptance criteria is detected, then the area of leakage shall be determined and the area repaired per ASME Code Section III, Subsection NB requirements. Re-testing shall be performed until the leakage rate acceptance criterion is met.

Casks loaded prior to July 1, 2009, to Amendment Nos. 2 through 7 are grandfathered and therefore not required to comply with the above helium leak test requirements. For these casks the following applies:

  • For tests of the lid base metal, the casks must meet the requirements of the amendment to which they were initially loaded.
  • Casks fabricated before July 1, 2009, do not require a leak test after shell to baseplate welding
  • For casks fabricated after July 1, 2009, a helium leak test at completion of welding the MPC shell HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-3

ATTACHMENT 1 TO HOLTEC LETTER 5014923 179 of 186 NRC FORM 651 U.S. NUCLEAR REGULATORY COMMISSION (3-1999) 10 CFR 72 CERTIFICATE OF COMPLIANCE Certificate No. 1014 FOR SPENT FUEL STORAGE CASKS Amendment No. 15 Supplemental Sheet Page 3 of 5 baseplate must be performed in accordance with the above requirements.

4. QUALITY ASSURANCE Activities in the areas of design, purchase, fabrication, assembly, inspection, testing, operation, maintenance, repair, modification of structures, systems and components, and decommissioning that are important to safety shall be conducted in accordance with a Commission-approved quality assurance program which satisfies the applicable requirements of 10 CFR Part 72, Subpart G, and which is established, maintained, and executed with regard to the cask system.
5. HEAVY LOADS REQUIREMENTS Each lift of an MPC, a HI-TRAC transfer cask, or any HI-STORM overpack must be made in accordance to the existing heavy loads requirements and procedures of the licensed facility at which the lift is made. A plant-specific review (under 10 CFR 50.59 or 10 CFR 72.48, if applicable) is required to show operational compliance with existing plant specific heavy loads requirements. Lifting operations outside of structures governed by 10 CFR Part 50 must be in accordance with Section 5.5 of Appendix A or Section 5.2 of Appendix C and Sections 3.4.6 and 3.5 (if applicable) of Appendix B or D, for above ground systems, section 5.5 of Appendix A-100U for the underground systems.
6. APPROVED CONTENTS Contents of the HI-STORM 100 Cask System must meet the fuel specifications given in Appendices B or D as applicable for aboveground systems or B-100U for underground systems to this certificate.
7. DESIGN FEATURES Features or characteristics for the site, cask or ancillary equipment must be in accordance with Appendices B or D, as applicable, for aboveground systems or B-100U for underground systems to this certificate.
8. CHANGES TO THE CERTIFICATE OF COMPLIANCE The holder of this certificate who desires to make changes to the certificate, which includes Appendices A, C, and A-100U (Technical Specifications) and Appendices B, D, and B-100U (Approved Contents and Design Features), shall submit an application for amendment of the certificate.
9. SPECIAL REQUIREMENTS FOR FIRST SYSTEMS IN PLACE
a. For the storage configuration, each user of a HI-STORM 100 Cask and HI-STORM 100U Cask with a heat load equal to or greater than 20 kW shall perform a thermal validation test in which the user measures the total air mass flow rate through the cask system using direct measurements of air velocity in the inlet vents. The user shall then perform an analysis of the cask with the taken measurements to demonstrate that the measurements validate the analytic methods described in Chapter 4 of the FSAR. The thermal validation test and analysis results shall be submitted in a letter report to the NRC pursuant to 10 CFR 72.4 within 180 days of the users loading of the first cask with heat load equal to or greater than 20 kW. To satisfy condition 9(a) for casks of the same system type (i.e., HI-STORM 100 casks, HI-STORM 100U casks), in lieu of additional submittals pursuant to 10 CFR 72.4, users may document in their 72.212 report a previously performed test and analysis submitted by letter report to the NRC that demonstrates validation of the analytic methods described in Chapter 4 of the FSAR.
b. For transfer configuration, each user of the HI-STORM 100 Cask and HI-STORM 100U Cask shall procure, if necessary, a Supplemental Cooling System (SCS) capable of providing the thermal-hydraulic characteristics (coolant temperature at the annulus inlet, coolant temperature located at the annulus outlet, and coolant flow rate) that will ensure that thermal limits (described in Appendix 2.C of the FSAR) are not exceeded during transfer operations. The thermal-hydraulic characteristics of the SCS shall be determined using the analytical methods described in Chapter 4 for the transfer configuration. For the transfer configuration, each first time user shall measure the SCS thermal-hydraulic characteristics to validate the performance of the SCS. The SCS analysis and validation shall be documented in an update to the 72.212 report within 180 days of the users first transfer operation with the SCS. Condition 9(b) does not apply to the MPC-68M or the MPC-32M.

HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-4

ATTACHMENT 1 TO HOLTEC LETTER 5014923 180 of 186 NRC FORM 651 U.S. NUCLEAR REGULATORY COMMISSION (3-1999) 10 CFR 72 CERTIFICATE OF COMPLIANCE Certificate No. 1014 FOR SPENT FUEL STORAGE CASKS Amendment No. 15 Supplemental Sheet Page 4 of 5

10. PRE-OPERATIONAL TESTING AND TRAINING EXERCISE A dry run training exercise of the loading, closure, handling, unloading, and transfer of the HI-STORM 100 Cask System shall be conducted by the licensee prior to the first use of the system to load spent fuel assemblies. The training exercise shall not be conducted with spent fuel in the MPC. The dry run may be performed in an alternate step sequence from the actual procedures, but all steps must be performed.

The dry run shall include, but is not limited to the following:

a. Moving the MPC and the transfer cask into the spent fuel pool or cask loading pool.
b. Preparation of the HI-STORM 100 Cask System for fuel loading.
c. Selection and verification of specific fuel assemblies to ensure type conformance.
d. Loading specific assemblies and placing assemblies into the MPC (using a dummy fuel assembly),

including appropriate independent verification.

e. Remote installation of the MPC lid and removal of the MPC and transfer cask from the spent fuel pool or cask loading pool.
f. MPC welding, NDE inspections, pressure testing, draining, moisture removal (by vacuum drying or forced helium dehydration, as applicable), and helium backfilling. (A mockup may be used for this dry-run exercise.)
g. Operation of the HI-STORM 100 SCS or equivalent system, if applicable.
h. Transfer cask upending/downending on the horizontal transfer trailer or other transfer device, as applicable to the sites cask handling arrangement.
i. Transfer of the MPC from the transfer cask to the overpack/VVM.
j. Placement of the HI-STORM 100 Cask System at the ISFSI, for aboveground systems only.
k. HI-STORM 100 Cask System unloading, including flooding MPC cavity, removing MPC lid welds. (A mockup may be used for this dry-run exercise.)
11. The NRC has approved an exemption request by the CoC applicant from the requirements of 10 CFR 72.236(f), to allow a Supplemental Cooling System to provide for decay heat removal in accordance with Section 3.1.4 of Appendices A, C, and A-100U.

HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-5

ATTACHMENT 1 TO HOLTEC LETTER 5014923 181 of 186 NRC FORM 651 U.S. NUCLEAR REGULATORY COMMISSION (3-1999) 10 CFR 72 CERTIFICATE OF COMPLIANCE Certificate No. 1014 FOR SPENT FUEL STORAGE CASKS Amendment No. 15 Supplemental Sheet Page 5 of 5

12. AUTHORIZATION The HI-STORM 100 Cask System, which is authorized by this certificate, is hereby approved for general use by holders of 10 CFR Part 50 licenses for nuclear reactors at reactor sites under the general license issued pursuant to 10 CFR 72.210, subject to the conditions specified by 10 CFR 72.212, this certificate, and the attached Appendices A, B, A-100U, B-100U, C, and D as applicable. The HI-STORM 100 Cask System may be fabricated and used in accordance with any approved amendment to CoC No. 1014 listed in 10 CFR 72.214. Each of the licensed HI-STORM 100 System components (i.e., the MPC, overpack, and transfer cask), if fabricated in accordance with any of the approved CoC Amendments, may be used with one another provided an assessment is performed by the CoC holder that demonstrates design compatibility.
13. FSAR UPDATE FOR RENEWED COC The CoC holder shall submit an updated FSAR to the Commission, in accordance with 10 CFR 72.4, within 90 days after the effective date of the renewal. The updated FSAR shall reflect the changes and CoC holder commitments resulting from the review and approval of the renewal of the CoC.
14. 72.212 EVALUATIONS FOR RENEWED COC USE Any general licensee that initiates spent fuel dry storage operations with the HI-STORM 100 system after the effective date of the renewal of the CoC and any general licensee operating a HI-STORM 100 system as of the effective date of the renewal of the CoC, including those that put additional storage systems into service after that date, shall:
a. As part of the evaluations required by 10CFR72.212(b)(5), include the evaluations related to the terms, conditions, and specifications of this CoC amendment as modified (i.e., changed or added) as a result of the renewal of the CoC.
b. As part of the document review required by 10CFR72.212(b)(6), include a review of the FSAR changes resulting from the renewal of the CoC; and
c. Ensure that the evaluations required by 10CFR72.212(b)(7) and (8) capture the evaluations and review described in (a) and (b) of this CoC condition.
d. Complete this condition prior to entering the period of extended operation or no later than 365 days after the effective date of the CoC renewal, whichever is later.
15. AMENDMENTS AND REVISIONS FOR RENEWED COC All future amendments and revisions to this CoC shall include evaluations of the impacts to aging management activities (i.e., time limited aging analyses and aging management programs) to assure they remain adequate for any changes to SSCs within the scope of renewal.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION TBD, Chief Licensing Branch Division of Spent Fuel Storage and TransportationFuel HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-6

ATTACHMENT 1 TO HOLTEC LETTER 5014923 182 of 186 Management Office of Nuclear Material Safety and Safeguards Washington, DC 20555 Dated TBD Attachments:

1. Appendix A
2. Appendix B
3. Appendix A-100U
4. Appendix B-100U
5. Appendix C
6. Appendix D HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-7

ATTACHMENT 1 TO HOLTEC LETTER 5014923 183 of 186 TABLE OF CONTENTS 1.0 USE AND APPLICATION ............................................................................... 1.1-1 1.1 Definitions ............................................................................................ 1.1-1 1.2 Logical Connectors .............................................................................. 1.2-1 1.3 Completion Times ................................................................................ 1.3-1 1.4 Frequency ............................................................................................ 1.4-1 2.0 NOT USED ..................................................................................................... 2.0-1 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY ............... 3.0-1 3.0 SURVEILLANCE REQUIREMENT (SR) APPLICABILITY ............................. 3.0-2 3.1 SFSC INTEGRITY ............................................................................ 3.1.1-1 3.1.1 Multi-Purpose Canister (MPC) ............................................... 3.1.1-1 3.1.2 SFSC Heat Removal System ................................................. 3.1.2-1 3.1.3 MPC Cavity Reflooding .......................................................... 3.1.3-1 3.1.4 Supplemental Cooling System ............................................... 3.1.4-1 3.2 SFSC RADIATION PROTECTION ................................................... 3.2.1-1 3.2.1 Deleted................................................................................... 3.2.1-1 3.2.2 TRANSFER CASK Surface Contamination ............................ 3.2.2-2 3.2.3 Deleted................................................................................... 3.2.3-1 3.3 SFSC CRITICALITY CONTROL ....................................................... 3.3.1-1 3.3.1 Boron Concentration .............................................................. 3.3.1-1 Table 3-1 MPC Cavity Drying Limits .................................................................... 3.4-1 Table 3-2 MPC Helium Backfill Limits .................................................................. 3.4-2 Table 3-3 Regionalized Storage Cell Heat Load Limits ....................... ..3.4-3 Table 3-4 Uniform Storage Cell Heat Load Limits.......3.4-3 Table 3-5 Completion Time for Actions to Restore SFSC Heat Removal System Operable.........3.4-4 4.0 NOT USED ....................................................................... 4.0-1 5.0 ADMINISTRATIVE CONTROLS.................................................................... 5.0-1 5.1 Deleted ................................................................................................ 5.0-1 5.2 Deleted ................................................................................................ 5.0-1 5.3 Deleted ................................................................................................ 5.0-1 5.4 Radioactive Effluent Control Program .................................................. 5.0-1 5.5 Cask Transport Evaluation Program .................................................... 5.0-2 5.6 Deleted ................................................................................................ 5.0-4 5.7 Radiation Protection Program .............................................................. 5.0-5 5.8 Aging Management Program .............................................................. 5.0-5 Certificate of Compliance No. 1014 Amendment No. 15 Appendix A i HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-8

ATTACHMENT 1 TO HOLTEC LETTER 5014923 184 of 186 Programs 5.0 ADMINISTRATIVE CONTROLS AND PROGRAMS 5.7 Radiation Protection Program (contd)

d. A minimum of five (5) dose rate measurements shall be taken on the top of the OVERPACK. One dose rate measurement shall be taken at approximately the center of the lid and four measurements shall be taken at locations on the top concrete shield, approximately half way between the center and the edge of the top concrete shield, 90 degrees apart around the circumference of the lid.
e. A dose rate measurement shall be taken on contact at the surface of each inlet and outlet vent duct screen of the OVERPACK.

5.8 Aging Management Program Each general licensee shall have a program to establish, implement, and maintain written procedures for each AMP described in the FSAR. The program shall include provisions for changing AMP elements, as necessary, and within the limitations of the approved licensing bases to address new information on aging effects based on inspection findings and/or industry operating experience provided to the general licensee during the renewal period.

The general licensee shall establish and implement these written procedures prior to entering the period of extended operation or no later thanwithin 365 days after the effective date of the renewal of the CoC or 365 days of the 20th anniversary of the loading of the first dry storage system at its site, whichever is later.

Each general licensee shall perform tollgate assessments as described in Chapter 9 of the FSAR.

Certificate of Compliance No. 1014 Amendment No. 15 Appendix A 5.0-7 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-9

ATTACHMENT 1 TO HOLTEC LETTER 5014923 185 of 186 TABLE OF CONTENTS 1.0 USE AND APPLICATION ............................................................................... 1.1-1 1.1 Definitions ............................................................................................ 1.1-1 1.2 Logical Connectors .............................................................................. 1.2-1 1.3 Completion Times ................................................................................ 1.3-1 1.4 Frequency ............................................................................................ 1.4-1 2.0 NOT USED ..................................................................................................... 2.0-1 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY ............... 3.0-1 3.0 SURVEILLANCE REQUIREMENT (SR) APPLICABILITY ............................. 3.0-2 3.1 SFSC INTEGRITY ............................................................................ 3.1.1-1 3.1.1 Multi-Purpose Canister........................................................... 3.1.1-1 3.1.2 HI-STORM 100S Version E SFSC Heat Removal System .... 3.1.2-1 3.1.3 MPC Cavity Reflooding ......................................................... 3.1.3-1 3.1.4 Supplemental Cooling System ............................................... 3.1.4-1 3.2 SFSC RADIATION PROTECTION ................................................... 3.2.1-1 3.2.1 TRANSFER CASK Surface Contamination ............................ 3.2.1-1 3.3 SFSC CRITICALITY CONTROL ....................................................... 3.3.1-1 3.3.1 Boron Concentration ............................................................. 3.3.1-1 Table 3-1 MPC Cavity Drying Limits .................................................................... 3.4-1 Table 3-2 MPC Helium Backfill Limits .................................................................. 3.4-3 Table 3-3 Completion Time for Actions to Restore HI-STORM 100S Version E SFSC Heat Removal System to Operable ..........3.4-4 Table 3-4 MPC-32M with up to Sixteen DFIs Soluble Boron Requirements .3.4-5 Table 3-5 MPC-32M with up to Twelve DFCs Soluble Boron Requirements ...3.4-6 Table 3-6 MPC-32M with Thirteen to Sixteen DFCs Soluble Boron Requirements .....3.4-7 Table 3-7 MPC-32/32F and Version 1 Soluble Boron Requirements ..3.4-8 4.0 NOT USED ....................................................................... 4.0-1 5.0 ADMINISTRATIVE CONTROLS.................................................................... 5.1-1 5.1 Radioactive Effluent Control Program for HI-STORM 100S Version E ................................................................. 5.1-1 5.2 Cask Transport Evaluation Program for HI-TRAC MS and HI-STORM 100S Version E .................................... 5.2-1 5.3 Radiation Protection Program .............................................................. 5.3-1 5.4 Aging Management Program ............................................................... 5.4-1 Certificate of Compliance No. 1014 Amendment No. 15 Appendix C i HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-10

ATTACHMENT 1 TO HOLTEC LETTER 5014923 186 of 186 Aging Management Program 5.4 ADMINISTRATIVE CONTROLS AND PROGRAMS 5.4 Aging Management Program Each general licensee shall have a program to establish, implement, and maintain written procedures for each AMP described in the FSAR. The program shall include provisions for changing AMP elements, as necessary, and within the limitations of the approved licensing bases to address new information on aging effects based on inspection findings and/or industry operating experience provided to the general licensee during the renewal period.

The general licensee shall establish and implement these written procedures prior to entering the period of extended operation or no later thanwithin 365 days after the effective date of the renewal of the CoC or 365 days of the 20th anniversary of the loading of the first dry storage system at its site, whichever is later.

Each general licensee shall perform tollgate assessments as described in Chapter 9 of the FSAR.

Certificate of Compliance No. 1014 Amendment No. 15 Appendix C 5.4-1 HI-2188877 HOLTEC INTERNATIONAL COPYRIGHT INFORMATION Rev. 1 E-11