ML22028A383
| ML22028A383 | |
| Person / Time | |
|---|---|
| Site: | Holtec |
| Issue date: | 01/28/2022 |
| From: | Holtec |
| To: | Office of Nuclear Material Safety and Safeguards |
| Shared Package | |
| ML22028A371 | List: |
| References | |
| 5014939 | |
| Download: ML22028A383 (84) | |
Text
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 1 of 84 CoC Condition/TS Identifier: ___D-2.1_______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 2.1: Fuel Specifications and Loading Conditions 2.1.1: Fuel Specifications and Loading Conditions 2.1.2: Fuel Loading CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes A2 Yes A3 Yes Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes The fuel specification requirements in the tables referenced in this TS are key to safe storage.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
Yes The fuel specification requirements in the tables referenced in this TS are key to safe storage.
A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes The fuel specification requirements in the tables referenced in this TS are key to safe storage.
Evaluation Summary Keep in Appendix D Section 2. Applies generically to all three criteria (A1, A2, A3).
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 2 of 84 CoC Condition/TS Identifier: __D-2.2________
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 2.2: Violations If any Fuel Specifications or Loading Conditions of 2.1 are violated, the following actions shall be completed:
2.2.1 The affected fuel assemblies shall be placed in a safe condition.
2.2.2 Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, notify the NRC Operations Center.
2.2.3 Within 30 days, submit a special report which describes the cause of the violation, and actions taken to restore compliance and prevent recurrence.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls Yes Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes Placing the fuel in a safe condition is key to safe storage The possibility of a new or different kind of accident Yes
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 3 of 84 being created compared to those previously evaluated in the FSAR?
Placing the fuel in a safe condition is key to safe storage A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes Placing the fuel in a safe condition is key to safe storage Evaluation Summary Move toAppendix D Section 4 as these are procedural and record keeping administrative controls. 2.2.1 specifies what must be done if the Fuel Specifications or Loading Conditions of 2.1 are violated. 2.2.2 and 2.2.3 give the administrative notification requirements to the NRC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 4 of 84 CoC Condition/TS Identifier: __D-Table 2.1-1________
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.1-1: Fuel Assembly Limits CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes - The following items in Table 2.1-1 are required per Criterion A1 and shall be retained:
Fuel (Type of spent fuel)
Cladding type (Type of spent fuel)
Enrichment Cooling time Burn-up Decay heat (heat designed to be dissipated)
Damaged fuel assemblies or fuel debris allowed per MPC (condition of spent fuel)
Neutron source assemblies and burnable poison rod assemblies (type of fuel)
A2 No A3 Yes (see evaluation summary below)
Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
A1 Items - Yes Other Items - No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 5 of 84 The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
A1 Items - Yes Other Items - No A Significant reduction in the margin of safety for ISFSI or cask operation?
A1 Items - Yes Other Items - No Evaluation Summary Keep A1 items identified above in CoC Appendix D Section 2.
The following characteristics will be eliminated from this table in the CoC and already exist in the FSAR:
(Tables 2.1.17 through 2.1.24)
Fuel assembly length Fuel assembly width If the Licensee has fuel that does not meet these characteristics that already exist in the FSAR, acceptability will be determined per 10 CFR 72.48.
Fuel assembly weight is a characteristic that would also not meet the Criteria A1 and A2 above. However, other CoC reorganization efforts have resulted in this characteristic being retained in the final approved CoC. Therefore, this characteristic could be said to meet Criterion A3 and will be retained in CoC Appendix D Section 2 with the rest of the retained information in this Table.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 6 of 84 CoC Condition/TS Identifier: ___D-Table 2.1-2_______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.1-2: PWR Fuel Assembly Characteristics for MPC-32M CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes - The following items in Table 2.1-2 are required per Criterion A1 and shall be retained:
Number of fuel rod locations (Type of spent fuel)
Number of guide and/or instrument tubes (Type of spent fuel)
A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
A1 Items - Yes Other Items - No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
A1 Items - Yes Other Items - No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 7 of 84 A Significant reduction in the margin of safety for ISFSI or cask operation?
A1 Items - Yes Other Items - No Evaluation Summary Keep A1 items identified above in CoC Appendix D Section 2.
The following characteristics will be eliminated from this table in the CoC and already exist in the FSAR (Tables 2.1.3 and 2.1.4):
Fuel cladding inner and outer diameters Fuel pellet diameter Fuel rod pitch Active fuel length Guide and/or instrument tube thickness If the Licensee has fuel that does not meet these characteristics that already exist in the FSAR, acceptability will be determined per 10 CFR 72.48.
Table notes connected only to the removed characteristics were also removed (notes 1 and 3).
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 8 of 84 CoC Condition/TS Identifier: ___D-Table 2.1-3 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.1-3: MPC-32M Non-Fuel Hardware Cooling and Average Burnup CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes This Table provides information on maximum heat designed to be dissipated (10CFR72.236(a)).
A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident consequences - thermal overheating and possible
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 9 of 84 cladding rupture - would occur sooner than the limits currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Evaluation Summary Keep in Appendix D Section 2 as this Table provides cooling time and burnup limits for approved content.
(Criterion A2)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 10 of 84 CoC Condition/TS Identifier: __D-Table 2.1-4_ _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.1-4: Burnup and Cooling Time Fuel Qualification for MPC-32M CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes This table provides information on burnup (10CFR72.236(a)).
A2 Yes A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes The margin to criticality during an accident could be impacted if neither the minimum burnup requirements nor the soluble boron limits from LCO 3.3.1 are met.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 11 of 84 Evaluation Summary Keep in Appendix D Section 2 as this Table provides cooling time and burnup limits for approved content.
(Criterion A2)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 12 of 84 CoC Condition/TS Identifier: ___D-Fig. 2.1-1 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Figure 2.1-1: Cell Identification for MPC-32M CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 Yes The information in these figures is referenced in the Fuel Assembly Limits table to inform the reader of where damaged fuel assemblies or fuel debris stored in DFCs may be loaded in the MPC basket. The permitted locations of damaged and failed fuel assemblies inside MPCs are key features required to provide reasonable assurance that the cask safety functions of decay heat removal and shielding will be maintained.
A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes The possibility of a new or different kind of accident being created compared Yes
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 13 of 84 to those previously evaluated in the FSAR?
A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes Evaluation Summary Keep in Appendix D Section 2 as this figure illustrates fuel loading information necessary to understand the information in other tables in this section. (Criterion A2) Specifically, discussions in other parts of the CoC (i.e. Table 2.1-1) refer to these figures when identifying permitted locations for storing DFCs. The permitted locations of damaged and failed fuel assemblies inside DFCs are key features required to provide reasonable assurance that the cask safety functions of decay heat removal and shielding will be maintained. The figures are also referred to in order to illustrate heat loading regions through the MPC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 14 of 84 CoC Condition/TS Identifier: ___D-2.4 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 2.4: Decay Heat Limits 2.4.1 Regionalized Fuel Loading Decay Heat Limits for ZR-Clad Fuel FOR A VENTILATED OVERPACK 2.4.2 Discrete Loading Pattern Decay Heat Limits for ZR-Clad Fuel for a VENTILATED OVERPACK 2.4.3 When complying with the maximum fuel storage location decay heat limits, users must account for the decay heat from both the fuel assembly and any NON-FUEL HARDWARE, as applicable for the particular fuel storage location, to ensure the decay heat emitted by all contents in a storage location does not exceed the limit.
2.4.4 Variable Fuel Height for MPC-32M 2.4.5 Decay Heat Limits for MPC-32M for UNVENTILATE OVERPACK CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes This section provides information on maximum heat designed to be dissipated (10CFR72.236(a)).
A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 15 of 84 Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident consequences - thermal overheating and possible cladding rupture - would occur sooner than the limits currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Evaluation Summary Keep in Appendix D Section 2 as this Section provides information on heat load limits (72.236(a)). (Criterion A1)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 16 of 84 CoC Condition/TS Identifier: ___ D-Table 2.4-1_______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.4-1: Allowable Heat Loads and Soluble Boron Requirements for MPC-32M CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes This Table provides information on maximum heat designed to be dissipated (10CFR72.236(a)).
A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes The probability of a criticality accident would be increased if the minimum soluble boron requirements are not met.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident consequences - thermal overheating and possible
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 17 of 84 cladding rupture - would occur sooner than the limits currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Loss of criticality control caused by inadequate soluble boron content would cause a significant reduction in the margin of safety.
Evaluation Summary Keep in Appendix D Section 2 as this Table provides information related to heat load limits (72.236(a)).
(Criterion A1)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 18 of 84 CoC Condition/TS Identifier: ___D-Table 2.4-2 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.4-2: Maximum Allowable Decay Heat Loads for MPC-32M CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix C.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes This Table provides information on maximum heat designed to be dissipated (10CFR72.236(a)).
A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident consequences - thermal overheating and possible
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 19 of 84 cladding rupture - would occur sooner than the limits currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Evaluation Summary Keep in Appendix D Section 2 as this Table provides information related to heat load limits (72.236(a)).
(Criterion A1)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 20 of 84 CoC Condition/TS Identifier: ___D-Tables 2.4-3 and 2.4-4 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.4-3: MPC-32M Fuel Storage Regions Table 2.4-4: MPC-32M Fuel Storage Quadrants CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 Yes A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident consequences - thermal overheating and possible cladding rupture - would occur sooner than the limits
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 21 of 84 currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Evaluation Summary Keep in Appendix D Section 2 as these Tables provide information on acceptable loading patterns for an MPC. (Criterion A2)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 22 of 84 CoC Condition/TS Identifier: ___D-Tables 2.4-5a and 2.4-5b _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.4-5a: MPC-32M Heat Load Data Unventilated Overpack Table 2.4-5b: MPC-32M Requirements on Developing Regionalized Heat Load Patterns for Unventilated Overpack CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes These tables provide information on maximum heat designed to be dissipated (10CFR72.236(a)).
A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 23 of 84 A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident consequences - thermal overheating and possible cladding rupture - would occur sooner than the limits currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Evaluation Summary Keep in Appendix D Section 2 as these Tables provide information on heat load limits (72.236(a)). (Criterion A1)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 24 of 84 CoC Condition/TS Identifier: ___D-Table 2.4-6 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.4-6: Section Heat Load Calculations for MPC-32M for Unventilated Overpack CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes This provides information on maximum heat designed to be dissipated (10CFR72.236(a)).
A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident consequences - thermal overheating and possible
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 25 of 84 cladding rupture - would occur sooner than the limits currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Evaluation Summary Keep in Appendix D Section 2 as this Section provides information on heat load limits (72.236(a)). (Criterion A1)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 26 of 84 CoC Condition/TS Identifier: ___D-Table 2.4-7 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 2.4-7: DFC and DFI Storage Locations with Heat Load Penalties for MPC-32M for UNVENTILATED OVERPACK CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 Yes This provides information on maximum heat designed to be dissipated (10CFR72.236(a)).
A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 27 of 84 consequences - thermal overheating and possible cladding rupture - would occur sooner than the limits currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Evaluation Summary Keep in Appendix D Section 2 as this Section provides information on heat load limits (72.236(a)). (Criterion A1)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 28 of 84 CoC Condition/TS Identifier: __D-Fig. 2.4-1 through 2.4-2_ _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Figure 2.4-1: Discrete Pattern A per Cell Allowable Heat Loads (kW) - MPC-32M Figure 2.4-2: Discrete Pattern B per Cell Allowable Heat Loads (kW) - MPC-32M CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 Yes A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat value for a given MPC is higher than that analyzed in the design bases, then if a blockage of the vents were to occur, the accident
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 29 of 84 consequences - thermal overheating and possible cladding rupture - would occur sooner than the limits currently specify. In addition, the use of MPC/Overpack models with a limited heat load is necessary to limit the occupational dose.
Evaluation Summary Keep in Appendix D Section 2 as this table provides information on acceptable loading patterns for an MPC. (Criterion A2)
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 30 of 84 CoC Condition/TS Identifier: ___D-3.1 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.1: Site 3.1.1: Site Location The HI-STORM 100 Cask System is authorized for general use by 10 CFR Part 50 license holders at various site locations under the provisions of 10 CFR 72, Subpart K.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 31 of 84 A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Eliminate from CoC - not required as compliance with the QA provisions in 10 CFR 72 Subpart K is a regulatory requirement that must be met.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 32 of 84 CoC Condition/TS Identifier: ___D-3.2 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.2: Design Features Important for Criticality Control 3.2.1: MPC-24, 24E, 24EF, 32, 32F, 68, 68F, 68FF and 68M, in HI-STORM 100S Version E shall meet the specifications of Appendix B Section 3.2 3.2.2: MPC-32 versions 1 3.2.3: MPC-68 version 1 3.2.4: MPC-32M CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes Acceptance Testing for neutron absorber material is necessary for the cask to operate in conformance with the certified design and fulfill its required safety functions.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement A significant increase in the probability or consequences of an accident previously No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 33 of 84 from the CoC/TS result in evaluated in the cask FSAR?
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes The margin of safety would be reduced or eliminated if the Metamic HT B-10 weight % and total Metamic radially surrounding the fuel assemblies is less than the requirements used in the criticality analysis.
Evaluation Summary Move to Appendix C - These features are not general enough to incorporate into the CoC main body. They are only included in Appendix C as they are important to acceptance testing related to criticality control.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 34 of 84 CoC Condition/TS Identifier: ___D-3.2.6 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.2.6: Neutron Absorber Tests MPC-24, 24E, 24EF, 32, 32F, 68, 68F, 68FF and 68M MPCs listed in 3.2.1 shall meet the minimum requirements for 10B areal density or B4C content, as applicable in Appendix B, Section 3.2.9.
MPC-32 Version 1 and MPC-68 Version 1 - Metamic Classic Section 9.1.5.3 of the HI-STORM 100 FSAR is hereby incorporated by reference into the HI-STORM 100 CoC. For each MPC model specified in Sections 3.2.2 and 3.2.3 (MPC-32 version 1 and MPC-68 version 1) above, the neutron absorber shall meet the minimum requirements for 10B areal density or B4C content, as applicable.
MPC-32M - Metamic-HT
- 1.
The weight percentage of the boron carbide must be confirmed to be greater than or equal to 10% in each lot of Al/B4C powder.
- 2.
The areal density of the B-10 isotope corresponding to the 10% min. weight density in the manufactured Metamic-HT panels shall be independently confirmed by the neutron attenuation test method by testing at least one coupon from a randomly selected panel in each lot.
- 3.
If the B-10 areal density criterion in the tested panels fails to meet the specific minimum, then the manufacturer has the option to reject the entire lot or to test a statistically significant number of panels and perform statistical analysis for acceptance.
- 4.
All test procedures used in demonstrating compliance with the above requirements shall conform to the cask designers QA program which has been approved by the USNRC under docket number 71-0784.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 35 of 84 CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Items 1 Yes Acceptance Testing for neutron absorber material is necessary for the cask to operate in conformance with the certified design and fulfill its required safety functions.
Item 4 - No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Items 1 Yes The margin of safety would be reduced if these neutron poison acceptance tests were not met. The results of the criticality analyses would be subject to question since assumptions underlying the analysis may no longer be valid.
Item 4 - No Evaluation Summary Move items 1-3 to Appendix C as the described tests ensure the MPC has been manufactured and will operate in conformance with the certified design, and that the safety functions of confinement, sub-criticality and shielding will be performed.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 36 of 84 Delete item 4 as this statement merely refers to NRC acceptance of the Holtec QA program manual under docket 71-0784. The Holtec QA program satisfies the requirements of 10 CFR 72 Subpart G. This statement can be removed from the CoC as compliance with the QA provisions in 10 CFR 72 Subpart G is a regulatory requirement that must be met.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 37 of 84 CoC Condition/TS Identifier: ___D-3.3 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.3: Codes and Standards The American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code), 1995 Edition with Addenda through 1997, is the governing Code for the HI-STORM 100 System MPCs, OVERPACKs, and TRANSFER CASKs, as clarified in Specification 3.3.1 below, except for Code Sections V and IX. The latest effective editions of ASME Code Sections V and IX, including addenda, may be used for activities governed by those sections, provided a written reconciliation of the later edition against the 1995 Edition, including addenda, is performed by the certificate holder. American Concrete Institute (ACI) 349-85 is the governing Code for plain concrete as clarified in Appendix 1.D of the Final Safety Analysis Report for the HI-STORM 100 Cask System.
CoC Body Certified Design Section I. Technology No Section II. Design Features Yes Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing A significant increase in the probability or Yes - If the Dry Cask Storage System ITS SSCs are not built in accordance with these codes and standards,
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 38 of 84 this requirement from the CoC/TS result in consequences of an accident previously evaluated in the cask FSAR?
then the consequences of an accident might be significant increased.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to CoC Section II as this explains which Codes and Standards are applicable to the cask and canister designs.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 39 of 84 CoC Condition/TS Identifier: ___D-3.3.1 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section: Alternatives to Codes, Standards, and Criteria Table 3-1 lists approved alternatives to the ASME Code for the design of the MPCs, OVERPACKs, and TRANSFER CASKs of the HI-STORM 100 Cask System.
CoC Body Certified Design Section I. Technology No Section II. Design Features Yes Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 40 of 84 A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to CoC Section II as this explains which Codes and Standards are applicable to the cask and canister designs.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 41 of 84 CoC Condition/TS Identifier: ___D-3.3.2 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.3.2: Construction/Fabrication Alternatives to Codes, Standards, and Criteria Proposed alternatives to the ASME Code, Sections II and III, 1995 Edition with Addenda through 1997 including modifications to the alternatives allowed by Specification 3.3.1 may be used on a case-specific basis when authorized by the Director of the Office of Nuclear Material Safety and Safeguards or designee.
The request for such alternative should demonstrate that:
- 1.
The proposed alternatives would provide an acceptable level of quality and safety, or
- 2.
Compliance with the specified requirements of the ASME Code,Section III, 1995 Edition with Addenda through 1997, would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
Requests for alternatives shall be submitted in accordance with 10 CFR 72.4.
CoC Body Certified Design Section I. Technology No Section II. Design Features Yes Appendix C - Inspections, Tests, and Evaluations Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 42 of 84 Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to CoC Section II as this explains which Codes and Standards are applicable to the cask and canister designs. Delete the following statement as it is not required because compliance with 10 CFR 72.4 is a regulatory requirement that must be met: Requests for alternatives shall be submitted in accordance with 10 CFR 72.4.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 43 of 84 CoC Condition/TS Identifier: ___ D-Table 3-1_______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 3-1: List of ASME Code Alternatives for HI-STORM Multi-Purpose Canisters (MPCs)
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes (see evaluation summary below)
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
N/A The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
N/A A Significant reduction in the margin of safety for ISFSI or cask operation?
N/A Evaluation Summary While this Table could potentially be removed without any risk impact, the removal could increase the need for cumbersome alternative code use
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 44 of 84 approval requests. Therefore, this table will be moved to Appendix C.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 45 of 84 CoC Condition/TS Identifier: ___D-3.4(1) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 1. The temperature of 70°F is the maximum average yearly temperature. A sites yearly average ambient temperature may be used for site-specific analysis.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes This site-specific parameter of maximum ambient temperature will need to be validated against the key design criteria used and evaluated in the CoC cask design in the decay heat removal related FSAR sections.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The consequences of the accident event would likely be greater but not significantly greater.
The possibility of a new or different kind of accident No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 46 of 84 being created compared to those previously evaluated in the FSAR?
A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 47 of 84 CoC Condition/TS Identifier: ___D-3.4(2) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 2. The allowed temperature extremes, averaged over a 3-day period, shall be greater than
-40o F and less than 125o F.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes This site-specific parameter of maximum extreme ambient temperature used for accident analyses will need to be validated against the key design criteria used and evaluated in the CoC cask design in the decay heat removal related FSAR sections.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The consequences of the accident event would likely be greater but not significantly greater.
The possibility of a new or different kind of accident No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 48 of 84 being created compared to those previously evaluated in the FSAR?
A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 49 of 84 CoC Condition/TS Identifier: ___B-3.4(3) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix B Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 3.
- a. The resultant horizontal acceleration (vectorial sum of two horizontal Zero Period Accelerations (ZPAs) at a three-dimensional seismic site), aH, and vertical ZPA, aV, on the top surface of the ISFSI pad, expressed as fractions of a, shall satisfy the following inequalities:
aH f (1 - aV); and aH r (1 - aV) / h where f is the Coulomb friction coefficient for the cask/ISFSI pad interface, r is the radius of the cask, and h is the height of the cask center-of-gravity above the ISFSI pad surface. Unless demonstrated by appropriate testing that a higher coefficient of friction value is appropriate for a specific ISFSI, the value used shall be 0.53. If acceleration time-histories on the ISFSI pad surface are available, aH and aV may be the coincident values of the instantaneous net horizontal and vertical accelerations. If instantaneous accelerations are used, the inequalities shall be evaluated at each time step in the acceleration time history over the total duration of the seismic event.
If this static equilibrium based inequality cannot be met, a dynamic analysis of the cask/ISFSI pad assemblage with appropriate recognition of soil/structure interaction effects shall be performed to ensure that the casks will not tip over or undergo
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 50 of 84 excessive sliding under the sites Design Basis Earthquake.
- b. For a free-standing OVERPACK under environmental conditions that may degrade the pad/cask interface friction (such as due to icing) the response of the casks under the sites Design Basis Earthquake shall be established using the best estimate of the friction coefficient in an appropriate analysis model. The analysis should demonstrate that the earthquake will not result in cask tipover or cause excessive sliding such that impact between casks could occur. Any impact between casks should be considered an accident for which the maximum total deflection, d, in the active fuel region of the basket panels shall be limited by the following inequality: d 0.005 l, where I is the basket cell inside dimension.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes The general licensee must perform an assessment to confirm that the site-specific seismic accelerations meet the cask seismic criteria applicable.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes If the site-specific seismic parameters (ZPA levels) are greater than those analyzed for the cask design and no anchoring is used, this could result in a cask tip-over or sliding, which would be a significant increase in the consequences of a seismic accident.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 51 of 84 The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 52 of 84 CoC Condition/TS Identifier: ___D-3.4(4) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 4. The maximum permitted depth of submergence under water shall not exceed 125 feet.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes It must be verified that the site-specific conditions are bounded by the enveloping design basis flood condition of 125 feet water height.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 53 of 84 A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 54 of 84 CoC Condition/TS Identifier: ___D-3.4(5) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 5. The maximum permissible velocity of floodwater, V, for a flood of height, h, shall be the lesser of V1 or V2, where:
V1 = (1.876 W*)1/2 / h V2 = (1.876 f W*/ D h)1/2 and W* is the apparent (buoyant weight) of the loaded overpack (in pounds force), D is the diameter of the overpack (in feet), and f is the interface coefficient of friction between the ISFSI pad and the overpack, as used in step 3.a above. Use the height of the overpack, H, if h>H.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes It must be verified that the site-specific flood water velocities meet the cask flood water design criteria considered in the FSAR.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this A significant increase in the probability or consequences of an No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 55 of 84 requirement from the CoC/TS result in accident previously evaluated in the cask FSAR?
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 56 of 84 CoC Condition/TS Identifier: ___D-3.4(6) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 6. The potential for fire and explosion while handling a loaded OVERPACK or TRANSFER CASK shall be addressed, based on site-specific considerations. The user shall demonstrate that the site-specific potential for fire is bounded by the fire conditions analyzed by the Certificate Holder, or an analysis of the site-specific fire considerations shall be performed.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes It must be verified that the site-specific loadings resulting from potential fires and explosions meet the loadings resulting from potential fires and explosions considered in the FSAR.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement A significant increase in the probability or consequences of an accident previously No The consequences of the accident event would likely be greater but not significantly greater. 10 CFR 72 Subpart K requires Licensees to confirm that no
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 57 of 84 from the CoC/TS result in evaluated in the cask FSAR?
conditions exist near the ISFSI that would result in pressures due to off-site explosions which would exceed those postulated in the FSAR for tornadic missiles or wind effects.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 58 of 84 CoC Condition/TS Identifier: ___D-3.4(7) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 7. The ISFSI pad shall be verified by analysis to meet the structural acceptance criteria set forth in section 2.II.2.2 of the HI-STORM FSAR. A restriction on the lift and/or drop height is not required to be established if the cask is lifted with a device designed in accordance with applicable stress limits from ANSI N14.6, and/or NUREG-0612, and has redundant drop protection features.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes The general licensee must perform an assessment to confirm that the site-specific ISFSI pad parameters meet the parameters considered for the ISFSI pad design in the FSAR.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement A significant increase in the probability or consequences of an accident previously Yes If the site-specific parameters are not bound by those analyzed for the ISFSI design, this could result in a cask tip-over.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 59 of 84 from the CoC/TS result in evaluated in the cask FSAR?
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 60 of 84 CoC Condition/TS Identifier: ___D-3.4(8) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 8. In cases where engineered features (i.e.,
berms and shield walls) are used to ensure that the requirements of 10CFR72.104(a) are met, such features are to be considered important-to-safety and must be evaluated to determine the applicable quality assurance category.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes If supplemental site-specific shielding or engineered features are required to keep doses to any real individual located beyond the controlled area below the dose requirements in 10 CFR 72.104(a), then these features are considered ITS and must be designed and controlled accordingly.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement A significant increase in the probability or consequences of an accident previously No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 61 of 84 from the CoC/TS result in evaluated in the cask FSAR?
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes Since the site dose for an ISFSI is highly site specific, each licensee must perform a dose analysis in accordance with 10 CFR 72.212. The analysis should consider existing plant conditions, the site-specific arrangement of the ISFSI, the characteristics of the spent fuel to be placed in dry storage, and relevant empirical data as appropriate. The on-site dose analysis should demonstrate compliance with the 10 CFR 72.104(a) limits for normal conditions and 10 CFR 72.106 for accident conditions.
Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 62 of 84 CoC Condition/TS Identifier: ___D-3.4(9) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 9. LOADING OPERATIONS, OVERPACK TRANSPORT OPERATIONS, and UNLOADING OPERATIONS shall only be conducted with working area ambient temperatures 0ºF for all MPC heat loads, and
- a. 90ºF (averaged over a 3-day period) for operations subjected to direct solar heating
- b. 110ºF (averaged over a 3-day period) for operations not subjected to direct solar heating for all MPC heat loads.
If the reference ambient temperature exceeds the corresponding Threshold Temperature then a site specific analysis shall be performed using the actual heat load and reference ambient temperature equal to the three day average to demonstrate that the steady state peak fuel cladding temperature will remain below the 400°C limit.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes These site-specific parameters of ambient temperature will need to be validated against the key design criteria used and evaluated in the FSAR for the cask design.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
L1 No L2 No L3 No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 63 of 84 and Surveillance Requirements (SRs)
(Selection Criteria)
Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The consequences of the accident event would likely be greater but not significantly greater.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 64 of 84 CoC Condition/TS Identifier: ___D-3.4(10) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 10. For those users whose site-specific design basis includes an event or events (e.g., flood) that result in the blockage of any OVERPACK inlet or outlet air ducts for an extended period of time (i.e, longer than the total Completion Time of LCO 3.1.2), an analysis or evaluation may be performed to demonstrate adequate heat removal is available for the duration of the event.
Adequate heat removal is defined as fuel cladding temperatures remaining below the accident temperature limit. If the analysis or evaluation is not performed, or if fuel cladding temperature limits are unable to be demonstrated by analysis or evaluation to remain below the accident temperature limit for the duration of the event, provisions shall be established to provide alternate means of cooling to accomplish this objective.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes Possible site-specific events causing vent blockages for an extended period of time must be evaluated.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance L1 No L2 No L3 No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 65 of 84 Requirements (SRs)
(Selection Criteria)
Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes The consequences of the accident event could be significantly increased if site-specific analysis is not performed for events that may result in blocked vents for an extended period of time and alternative means of cooling is not provided where necessary based on these evaluations.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 66 of 84 CoC Condition/TS Identifier: ___D-3.4(11) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 11. Users shall establish procedural and/or mechanical barriers to ensure that during LOADING OPERATIONS and UNLOADING OPERATIONS, either the fuel cladding is covered by water, or the MPC is filled with an inert gas.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 67 of 84 to those previously evaluated in the FSAR?
A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Delete from CoC. The intent of this item is to limit possible oxidation of the fuel. It is mentioned elsewhere in the CoC (see LCO 3.1.1) that the dry MPC will be helium filled. Also, procedures in the FSAR already contain cautions that Inert gas must be used any time the fuel is not covered with water to prevent oxidation of the fuel cladding. The fuel cladding is not to be exposed to air at any time during loading operations. This caution applies to all sites and 10 CFR 72.150 requires that documented procedures be followed. Therefore, this item does not serve any safety purpose in the CoC and may be removed.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 68 of 84 CoC Condition/TS Identifier: ___D-3.4(12) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 12. The entire haul route shall be evaluated to ensure that the route can support the weight of the loaded system and its conveyance.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes The general licensee must perform an assessment to confirm that the site-specific haul route can support the equipment weights required for use of the HI-STORM System.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes If the haul route cannot be shown to adequately support the weights of the loading system and conveyance, there would be an increased probability of a drop or tipover of the cask.
The possibility of a new or different kind of accident being created compared No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 69 of 84 to those previously evaluated in the FSAR?
A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 70 of 84 CoC Condition/TS Identifier: ___D-3.4(13) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 13. The loaded system and its conveyance shall be evaluated to ensure under the site specific Design Basis Earthquake the system does not tipover or slide off the haul route.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes The general licensee must perform an assessment to confirm that the site-specific seismic accelerations meet the seismic criteria applicable to the design of the casks and their conveyance.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes If the site-specific seismic parameters (ZPA levels) are greater than those analyzed for the cask and conveyance designs, this could result in a cask tip-over or sliding off the haul route, which would be a significant increase in the consequences of a seismic accident.
The possibility of a new or different kind of accident No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 71 of 84 being created compared to those previously evaluated in the FSAR?
A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 72 of 84 CoC Condition/TS Identifier: ___D-3.4(14) _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.4: Site Specific Parameters and Analyses that will require verification by the system user are, as a minimum, as follows:
- 14. The HI-STORM 100S Version E /HI-TRAC stack which occurs during MPC TRANSFER shall be evaluated to ensure under the site specific Design Basis Earthquake the system does not tipover. A probabilistic risk assessment cannot be used to rule out the occurrence of the earthquake during MPC TRANSFER.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes The general licensee must perform an assessment to confirm that the site-specific seismic accelerations meet the seismic criteria applicable to the overpack/transfer cask stack-up configuration that occurs during transfer of the MPC.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement A significant increase in the probability or consequences of an accident previously Yes If the site-specific seismic parameters (ZPA levels) are greater than those analyzed for overpack/transfer cask stack-up configuration that occurs during transfer of the MPC, this could result in a cask tip-
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 73 of 84 from the CoC/TS result in evaluated in the cask FSAR?
over, which would be a significant increase in the consequences of a seismic accident.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 74 of 84 CoC Condition/TS Identifier: ___D-3.5 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.5: Cask Transfer Facility (CTF) 3.5.1: Transfer Cask and MPC Lifters 3.5.2: CTF Structure Requirements 3.5.2.1: Cask Transfer Station and Stationary Lifting Devices 3.5.2.2: Mobile Lift Devices CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes If the CTF and Lifting Devices cannot be shown to adequately support the weights of the loading system, there would be an increased probability of a drop or a tipover.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 75 of 84 Evaluation Summary Move to Appendix C as this includes design features for equipment that is only needed under specified circumstances, unlike the main equipment for the system described in CoC Sections I and II.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 76 of 84 CoC Condition/TS Identifier: ___D-Table 3-2 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Table 3-2: Load Combinations and Service Condition Definitions for the CTF Structure CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes If the CTF cannot be shown to adequately support the weights of the loading system, there would be an increased probability of a drop or a tipover.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix C as this includes design features for equipment that is only needed under specified circumstances, unlike the main equipment for the system described in CoC Sections I and II.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 77 of 84 CoC Condition/TS Identifier: ___D-3.6 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.6: Forced Helium Dehydration System 3.6.1: System Description 3.6.2: Design Criteria 3.6.3: Fuel Cladding Temperature 3.6.4: Pressure Monitoring During FHD Malfunction CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
Yes If the maximum heat or pressure values for a given MPC are higher than analyzed in the design bases,
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 78 of 84 then if an event such as a blockage of the vents were to occur, the accident consequences - thermal overheating and possible cladding rupture - would occur sooner than the limits currently specify.
Evaluation Summary Move to Appendix C as this includes design features for equipment that is only needed under specified circumstances, unlike the main equipment for the system described in CoC Sections I and II.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 79 of 84 CoC Condition/TS Identifier: ___D-3.7 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.7: Supplemental Cooling System 3.7.1: System Description 3.7.2: Design Criteria CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No - Failure of the Supplemental Cooling System is evaluated as an accident in the FSAR and it is concluded that the SCS failure does not affect the safe operation of the HI-STORM 100 System.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Delete from CoC as this discussion is merely overly prescriptive information about a supplementary
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 80 of 84 system that is fully discussed in the FSAR and this is not required to be in the CoC for safety per the evaluation above. Also, the CoC main body already addresses the approved exemption allowing for the use of the SCS and LCO is established to ensure its functionality.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 81 of 84 CoC Condition/TS Identifier: ___D-3.8 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.8: Combustible Gas Monitoring During MPC Lid Welding and Cutting During MPC lid-to-shell welding and cutting operations, combustible gas monitoring of the space under the MPC lid is required, to ensure that there is no combustible mixture present.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations No Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L1 No L2 No L3 No Section 4 Administrative Controls Yes Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
Yes Unnoticed buildup of combustible gas could increase the probability or severity of a fire.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
Yes A combustible gas explosion could result. This would be an accident threatening occupational workers as well as possible loss of confinement.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 82 of 84 A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Move to Appendix D Section 4, Administrative Controls, as these controls are necessary to assure that the operations involved in the storage of spent fuel and reactor-related GTCC waste in an ISFSI are performed in a safe manner. These controls prevent a potential explosion of combustible gas during establishment of the confinement boundary or purposeful breaching of the confinement boundary.
The explosion could affect confinement and shielding and functions and is a personnel safety item.
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 83 of 84 CoC Condition/TS Identifier: ___D-3.9 _______
- All LCOs also require an Applicability, Condition(s), Required Action(s), Completion Time(s),
Surveillance Requirement(s), and Frequency(ies). Refer to NUREG-1745 for additional guidance.
- In performing the risk insight evaluation above, the evaluator should think about subsequent changes to a relocated CoC requirement. Specifically, ask the question what is the likelihood and worst possible consequences of a future change to this requirement in the less conservative direction?
Requirement Appendix D Section 3.9: Environmental Temperature Requirements TRANSPORT OPERATIONS involving any version of the HI-TRAC transfer cask can be carried out if the reference ambient temperature (three day average around the cask) is ABOVE 0° F and below the Threshold Temperature of 110 deg. F ambient temperature, applicable during HI-TRAC MS transfer operations inside the 10 CFR Part 50 or 10 CFR Part 52 structural boundary and 90 deg. F outside of it.
The determination of the Threshold Temperature compliance shall be made based on the best available thermal data for the site.
If the reference ambient temperature exceeds the corresponding Threshold Temperature then a site specific analysis shall be performed using the actual heat load and reference ambient temperature equal to the three day average to ensure that the steady state peak fuel cladding temperature will remain below the ISG-11 Rev 3 limits. If the peak fuel cladding temperature exceeds ISG-11 Rev 3 limits, then the operation of a Supplemental Cooling System (SCS) in accordance with LCO 3.1.4 is mandatory.
CoC Body Certified Design Section I. Technology No Section II. Design Features No Appendix C - Inspections, Tests, and Evaluations Yes Site-specific ambient temperatures will need to be validated against the key design criteria used and evaluated in the FSAR for the cask design.
Appendix D.
Technical Specifications Section 1 Definitions, Use and Application No Section 2 Approved Contents (Selection Criteria)
A1 No A2 No A3 No L1 No
CoC Condition/Technical Specification Evaluation Form - CoC original Appendix D Page 84 of 84 Section 3 Limiting Conditions for Operation (LCOs)*
and Surveillance Requirements (SRs)
(Selection Criteria)
L2 No L3 No Section 4 Administrative Controls No Risk Insight**:
Will removing this requirement from the CoC/TS result in A significant increase in the probability or consequences of an accident previously evaluated in the cask FSAR?
No The consequences of the accident event would likely be greater but not significantly greater.
The possibility of a new or different kind of accident being created compared to those previously evaluated in the FSAR?
No A Significant reduction in the margin of safety for ISFSI or cask operation?
No Evaluation Summary Moved to Appendix C as this includes key generic design criteria used by the CoC holder in the cask design, which require general licensee evaluation. A 72.212 evaluation by the General Licensee will perform written evaluations confirming that the site meets the terms, conditions, and specifications of the approved cask CoC.