{{#Wiki_filter:0610312016 U.S. Nuclear Regulatory Commission Operations Center Event Report Part 21 (PAR) Rep Org: AMETEK SOLIDSTATE CONTROLS Supplier: | {{#Wiki_filter:0610312016 U.S. Nuclear Regulatory Commission Operations Center Event Report Part 21 (PAR) Rep Org: AMETEK SOLIDSTATE CONTROLS Supplier: | ||
SIGNAL TRANSFORMER Region: 3 Event# Notification Date I Time: 06/02/2016 16:30 Event Date I Time: 06/02/2016 Last Modification: | SIGNAL TRANSFORMER Region: 3 Event# Notification Date I Time: 06/02/2016 16:30 Event Date I Time: 06/02/2016 Last Modification: | ||
06/02/2016 Docket#: | 06/02/2016 Docket#: City: COLUMBUS County: Agreement State: Yes State: OH NRC Notified by: ETHAN SALSBURY HQ Ops Officer: DONG HWA PARK Emergency Class: NON EMERGENCY 10 CFR Section: 21.21 (d)(3)(i) | ||
City: COLUMBUS County: Agreement State: Yes State: OH NRC Notified by: ETHAN SALSBURY HQ Ops Officer: | |||
DONG HWA PARK Emergency Class: NON EMERGENCY 10 CFR Section: | |||
21.21 (d)(3)(i) | |||
DEFECTS AND NONCOMPLIANCE License#: | DEFECTS AND NONCOMPLIANCE License#: | ||
Notifications: | Notifications: | ||
Line 33: | Line 30: | ||
******************************************************************************************************************************** | ******************************************************************************************************************************** | ||
\. \ | \. \ | ||
***** SOLIDSTATE CONTROLS Quality Assurance 875 Dearborn Drive, Columbus, OH 43085 U.S.A. Telephone: | ***** SOLIDSTATE CONTROLS Quality Assurance 875 | ||
==Dearborn Drive,== | |||
Columbus, OH 43085 U.S.A. Telephone: | |||
614-846-7500, 1-800-635-7300 E-mail: ethan.salsbury@ametek.com June 2, 2016 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Attention: | 614-846-7500, 1-800-635-7300 E-mail: ethan.salsbury@ametek.com June 2, 2016 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Attention: | ||
Document Control Desk | Document Control Desk | ||
==Subject:== | ==Subject:== | ||
Notification of Potential Defect -1 OCFR Part 21 .\METEK Product: Ametek inverter manufactured with Signal Transformer R-10607, Ametek part number 80-310879-90 was inadvertently installed in several units from an unapproved supplier. | |||
Notification of Potential Defect -1 OCFR Part 21 .\METEK Product: | |||
Ametek inverter manufactured with Signal Transformer R-10607, Ametek part number 80-310879-90 was inadvertently installed in several units from an unapproved supplier. | |||
The potential for this situation to occur exists for new equipment delivered between July of 2015 and May of 2016. Affected utilities and equipment serial numbers are identified below. Dominion Nuclear Connecticut, Millstone 96000067-0411 96000067-0511 96000067-0611 96000067-0711 Krsko Nuclear Power Plant 96000068-0211 96000068-0311 | The potential for this situation to occur exists for new equipment delivered between July of 2015 and May of 2016. Affected utilities and equipment serial numbers are identified below. Dominion Nuclear Connecticut, Millstone 96000067-0411 96000067-0511 96000067-0611 96000067-0711 Krsko Nuclear Power Plant 96000068-0211 96000068-0311 | ||
96000068-0411 Exelon, Byron Station 96000075-0311 96000075-0411 96000075-0511 96000075-0611 Ametek Solidstate Controls is submitting the following Report of a Potential Defect in accordance with the requirements of 1 OCFR Part 21. Please contact me if you require any further information. | 96000068-0411 Exelon, Byron Station 96000075-0311 96000075-0411 96000075-0511 96000075-0611 Ametek Solidstate Controls is submitting the following Report of a Potential Defect in accordance with the requirements of 1 OCFR Part 21. Please contact me if you require any further information. | ||
Sincerely, c!!df-4? | Sincerely, c!!df-4? Ethan Salsbury Quality Supervisor Ametek Solidstate Controls SOLIDSTATE | ||
Ethan Salsbury Quality Supervisor Ametek Solidstate Controls SOLIDSTATE | |||
,. f CONTROLS | ,. f CONTROLS | ||
***** .AMETEK COMPONENT DESCRIPTION: | ***** .AMETEK COMPONENT DESCRIPTION: |
Revision as of 09:34, 8 July 2018
ML16162A680 | |
Person / Time | |
---|---|
Site: | Millstone, Byron ![]() |
Issue date: | 06/03/2016 |
From: | Salsbury E Ametek Solidstate Controls |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
51972 | |
Download: ML16162A680 (4) | |
Text
0610312016 U.S. Nuclear Regulatory Commission Operations Center Event Report Part 21 (PAR) Rep Org: AMETEK SOLIDSTATE CONTROLS Supplier:
SIGNAL TRANSFORMER Region: 3 Event# Notification Date I Time: 06/02/2016 16:30 Event Date I Time: 06/02/2016 Last Modification:
06/02/2016 Docket#: City: COLUMBUS County: Agreement State: Yes State: OH NRC Notified by: ETHAN SALSBURY HQ Ops Officer: DONG HWA PARK Emergency Class: NON EMERGENCY 10 CFR Section: 21.21 (d)(3)(i)
DEFECTS AND NONCOMPLIANCE License#:
Notifications:
DAN SCHROEDER DAVID HILLS PART 21/50.55 REACTORS Pagel 51972 (EDT) (EDT) R1DO R3DO EMAIL PART 21 -NOT APPROVED CURRENT TRANSFORMERS INSTALLED IN SAFETY RELATED EQUIPMENT The following was excerpted from the Ammeter Part 21 Report: "Ametek inverter manufactured with Signal Transformer R-10607, Ametek part number 80-310879-90 was inadvertently installed in several units from an unapproved supplier.
The potential for this situation to occur exists for new equipment delivered between July of 2015 and May of 2016. Affected utilities and equipment serial numbers are identified below. "Dominion Nuclear Connecticut, Millstone 96000067-0411, 96000067-0511, 96000067-0611, 96000067-0711 "Krsko Nuclear Power Plant 96000068-0211, 96000068-0311, 96000068-0411 "Exelon, Byron Station 96000075-0311, 96000075-0411, 96000075-0511,96000075-0611 "Ametek Solidstate Controls is submitting the following Report of a Potential Defect in accordance with the requirements of 1 OCFR Part 21. "To replace the transformers, Ametek Solidstate Controls will work with you to arrange replacements.
Please our Client Services group at 1-614-846-7500.
mailto: eric.phillips@ametek.com" The potential problems include:
0610312016 U.S. Nuclear Regulatory Commission Operations Center Event Report Page 2 -Mag wire terminated with improper lug and tooling which may cause loss of feedback to static transfer function.
-Spot welded band around the core which has not been adequately seismically evaluated.
-180 degree Celsius insulation system provided instead of the approved 200 degree Celsius and unapproved materials used which impacts the aging analysis.