{{#Wiki_filter:
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 2100 RENAISSANCE BLVD., SUITE 100 KING OF PRUSSIA, PA 19406
[[Issue date::November 17, 2015]]
-2713 November 17, 2015 Mr. Timothy President and Chief Nuclear Officer Susquehanna Nuclear, LLC 769 Salem Blvd  
 
- NUCSB3 Berwick, PA 18603
Mr. Timothy President and Chief Nuclear Officer Susquehanna Nuclear, LLC 769 Salem Blvd - NUCSB3 Berwick, PA 18603-0467
-0467


SUBJECT: SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 - MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT NO. 05000387/2015405 and 05000388/2015405
SUBJECT: SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 - MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT NO. 05000387/2015405 and 05000388/2015405


==Dear Mr. Rausch:==
==Dear Mr. Rausch:==
On October 23, 2015, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Susquehanna Steam Electric Station, Units 1 and 2. The inspection covered one of the key attributes of the security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on October 23, 2015, with you and other members of your staff. The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.
On October 23
, 2015, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Susquehanna Steam Electric Station, Units 1 and 2
. The inspection covered one of the key attributes of the security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on October 23, 2015, with you and other members of your staff. The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.


Based on the results of this inspection, no findings were identified.
Based on the results of this inspection, no findings were identified.


In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agency-wide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(3)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's document system (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html. If Security-Related Information is Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, the transmittal document is decontrolled. necessary to provide an acceptable response, please mark your entire response Security-Related Information in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your responses.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's "Rules of Practice,"
a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agency-wide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading
-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(3)(1)
and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's document system (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading
-rm/adams.html.
 
If Security-Related Information is Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, the transmittal document is decontrolled. necessary to provide an acceptable response, please mark your entire response Security-Related Information in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your responses.
 
Sincerely,/RA/ Mel Gray, Chief Engineering Branch 1 Division of Reactor Safety


Sincerely,/RA/ Mel Gray, Chief Engineering Branch 1 Division of Reactor Safety Docket Nos. 50-387, 50-388 License Nos. NPF-14, NPF-22 Nonpublic  
Docket Nos. 50
-387, 50-388 License Nos. NPF
-14, NPF-22 Nonpublic  


===Enclosure:===
===Enclosure:===
Line 38: Line 50:


===w/Attachment:===
===w/Attachment:===
Supplemental Information cc w/o encl; w/o OUO-SRI: Distribution via ListServ cc w/encl; w/OUO-SRI JGorman, Manager, Nuclear Security DAllard, Director, PA DEP  
Supplemental Information cc w/o encl; w/o OUO-SRI: Distribution via ListServ cc w/encl; w/OUO-SRI JGorman, Manager, Nuclear Security DAllard, Director, PA DEP


ML15321A032 (Cover letter) ADAMS ACCESSION NUMBER: ML15321A028 (Cover letter w/enclosure) Cover Letter: SUNSI Review Non-Sensitive Sensitive Publicly Available Non-Publicly Available Cover Letter w/  
ML15321A032 (Cover letter)
ADAMS ACCESSION NUMBER:
ML15321A028 (Cover letter w/enclosure)
Cover Letter:
SUNSI Review Non-Sensitive Sensitive Publicly Available Non-Publicly Available Cover Letter w/  


===Enclosure:===
===Enclosure:===
SUNSI Review Non-Sensitive Sensitive Publicly Available Non-Publicly Available OFFICE RI/DRS RI/DRP RI/DRS NAME SChaudhary DSchroeder MGray DATE 11/9/15 11/9/15 11/17/15 Letter to Mr. Timothy Rausch from Mel Gray SUBJECT: SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2-MATERIAL  CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT NO. 05000387/2015405 AND 05000388/2015405 Distribution w/o encl; w/o OUO-SRI: (via E-mail) DDorman, RA (R1ORAMAIL Res) DLew, DRA (R1ORAMAIL Res) MScott, DRP (R1DRPMAIL Res) JColaccino, DRP (R1DRPMAIL Res) RLorson, DRS (R1DRSMAIL Res) GSuber, DRS (R1DRSMAIL Res) DSchroeder, DRP SBarber, DRP ATurilin, DRP PMeier, DRP JGreives, DRP, SRI TDaun, DRP, RI AGould, DRP, AA JJessie, RI, OEDO RidsNrrPMSusquehanna Resource RidsNrrDorlLpl1-2 Resource ROPreports Resource Distribution w/encl; w/OUO-SRI CJohnson, NSIR NSimonian, NSIR EWharton, NSIR BDesai, DRS, RII SOrth, DRS, RIII MHaire, DRS, RIV DSchroeder, DRP J. Greives, DRP, SRI GTuttle, NMSS PHabighorst, NMSS
SUNSI Review Non-Sensitive Sensitive Publicly Available Non-Publicly Available OFFICE RI/DRS RI/DRP RI/DRS NAME SChaudhary DSchroeder MGray DATE 11/9/15 11/9/15 11/17/15 Letter to Mr.
 
Timothy Rausch from Mel Gray
 
SUBJECT:
SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2-MATERIAL  CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT NO.
 
05000387/
2015405 AND 05000388/2015405 Distribution w/o encl; w/o OUO-SRI: (via E-mail) DDorman, RA (R1ORAMAIL Res)
DLew, DRA (R1ORAMAIL Res)
MScott, DRP (R1DRPMAIL Res)
JColaccino, DRP (R1DRPMAIL Res) RLorson, DRS (R1DRSMAIL Res)
GSuber, DRS (R1DRSMAIL Res)
DSchroeder, DRP SBarber, DRP ATurilin, DRP PMeier, DRP JGreives, DRP, SRI TDaun, DRP, RI AGould, DRP, AA JJessie, RI, OEDO RidsNrrPMSusquehanna Resource RidsNrrDorlLpl1
-2 Resource ROPreports Resource Distribution w/encl; w/OUO-SRI CJohnson, NSIR NSimonian, NSIR EWharton, NSIR BDesai, DRS, RII SOrth, DRS, RIII MHaire, DRS, RIV DSchroeder, DRP J. Greives, DRP, SRI GTuttle, NMSS PHabighorst, NMSS
}}
}}

Revision as of 18:26, 30 June 2018

IR 05000387/2015405 and 05000388/2015405, Susquehanna Steam Electric Station, Units 1 and 2, Security Baseline Inspection (Letter Only)
ML15321A032
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 11/17/2015
From: Mel Gray
Engineering Region 1 Branch 1
To: Rausch T S
Susquehanna
References
IR 2015405
Download: ML15321A032 (4)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 2100 RENAISSANCE BLVD., SUITE 100 KING OF PRUSSIA, PA 19406

-2713 November 17, 2015 Mr. Timothy President and Chief Nuclear Officer Susquehanna Nuclear, LLC 769 Salem Blvd

- NUCSB3 Berwick, PA 18603

-0467

SUBJECT: SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 - MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT NO. 05000387/2015405 and 05000388/2015405

Dear Mr. Rausch:

On October 23

, 2015, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Susquehanna Steam Electric Station, Units 1 and 2

. The inspection covered one of the key attributes of the security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on October 23, 2015, with you and other members of your staff. The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, no findings were identified.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's "Rules of Practice,"

a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agency-wide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading

-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(3)(1)

and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's document system (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading

-rm/adams.html.

If Security-Related Information is Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, the transmittal document is decontrolled. necessary to provide an acceptable response, please mark your entire response Security-Related Information in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your responses.

Sincerely,/RA/ Mel Gray, Chief Engineering Branch 1 Division of Reactor Safety

Docket Nos. 50

-387, 50-388 License Nos. NPF

-14, NPF-22 Nonpublic

Enclosure:

NRC Inspection Report 05000387/2015405 and 05000388/2015405

w/Attachment:

Supplemental Information cc w/o encl; w/o OUO-SRI: Distribution via ListServ cc w/encl; w/OUO-SRI JGorman, Manager, Nuclear Security DAllard, Director, PA DEP

ML15321A032 (Cover letter)

ADAMS ACCESSION NUMBER:

ML15321A028 (Cover letter w/enclosure)

Cover Letter:

SUNSI Review Non-Sensitive Sensitive Publicly Available Non-Publicly Available Cover Letter w/

Enclosure:

SUNSI Review Non-Sensitive Sensitive Publicly Available Non-Publicly Available OFFICE RI/DRS RI/DRP RI/DRS NAME SChaudhary DSchroeder MGray DATE 11/9/15 11/9/15 11/17/15 Letter to Mr.

Timothy Rausch from Mel Gray

SUBJECT:

SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2-MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT NO.

05000387/

2015405 AND 05000388/2015405 Distribution w/o encl; w/o OUO-SRI: (via E-mail) DDorman, RA (R1ORAMAIL Res)

DLew, DRA (R1ORAMAIL Res)

MScott, DRP (R1DRPMAIL Res)

JColaccino, DRP (R1DRPMAIL Res) RLorson, DRS (R1DRSMAIL Res)

GSuber, DRS (R1DRSMAIL Res)

DSchroeder, DRP SBarber, DRP ATurilin, DRP PMeier, DRP JGreives, DRP, SRI TDaun, DRP, RI AGould, DRP, AA JJessie, RI, OEDO RidsNrrPMSusquehanna Resource RidsNrrDorlLpl1

-2 Resource ROPreports Resource Distribution w/encl; w/OUO-SRI CJohnson, NSIR NSimonian, NSIR EWharton, NSIR BDesai, DRS, RII SOrth, DRS, RIII MHaire, DRS, RIV DSchroeder, DRP J. Greives, DRP, SRI GTuttle, NMSS PHabighorst, NMSS