=Text= | =Text= | ||
{{#Wiki_filter:Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee | {{#Wiki_filter:Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 July 5, 2013 10 CFR 50.4 10 CFR 50.71(e) | ||
ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Sequoyah Nuclear Plant, Units 1 and 2 Facility Operating License Nos. DPR-77 and DPR-79 NRC Docket Nos. 50-327 and 50-328 | |||
==Subject:== | ==Subject:== | ||
Revisions to the Sequoyah Nuclear Plant Technical Requirements Manual and Units I and 2 Technical Specification Bases | Revisions to the Sequoyah Nuclear Plant Technical Requirements Manual and Units I and 2 Technical Specification Bases | ||
==References:== | ==References:== | ||
: 1. NRC Letter to TVA, "Issuance of Exemption to 10 CFR 71(e)(4) for | : 1. NRC Letter to TVA, "Issuance of Exemption to 10 CFR 71(e)(4) for the Sequoyah Nuclear Plant, Units 1 and 2 (TAC Nos. MA0646 and MA0647)," dated March 9, 1998 | ||
dated March 9, | : 2. TVA Letter to NRC, "Revisions to the Sequoyah Nuclear Plant Technical Requirements Manual and Units 1 and 2, Technical Specification Bases," | ||
The SQN Technical Requirements Manual (TRM) is incorporated | dated December 16, 2011 Pursuant to 10 CFR 50.71(e) and the Reference 1 letter, updates to the Sequoyah Nuclear Plant (SQN) Updated Final Safety Analysis Report (UFSAR) for both Units 1 and 2 are to be submitted within six months after each refueling outage, not to exceed 24 months between successive revisions. The SQN Technical Requirements Manual (TRM) is incorporated by reference into the SQN UFSAR. In addition, SQN Technical Specification 6.8.4.j, "Technical Specification (TS) Bases Control Program," requires changes to the SQN TS Bases to be submitted in accordance with 10 CFR 50.71(e). This letter provides the required updates to the SQN TRM and TS Bases since the previous update submitted via the Reference 2 Letter. The last Unit 2 refueling outage ended on January 6, 2013, and as such, these updates are required by July 5, 2013. The enclosure to this letter provides a description of the TRM and TS Bases revisions with attachments of the updated pages, respectively. | ||
requires changes to the SQN TS Bases to | Printed on recycled paper | ||
This letter provides the required updates | |||
Printed on recycled paper U.S. Nuclear Regulatory Commission Page | U.S. Nuclear Regulatory Commission Page 2 July 5, 2013 There are no commitments contained in this letter. If you have any questions, please contact Michael McBrearty at (423) 843-7170. | ||
I certify that I am duly authorized by TVA, and that, to the best of my knowledge and belief,the information contained herein accurately presents changes made since the | I certify that I am duly authorized by TVA, and that, to the best of my knowledge and belief, the information contained herein accurately presents changes made since the previous submittal, necessary to reflect information and analyses submitted to the Commission or prepared pursuant to Commission requirements. | ||
Respectf lly,eesident, Nuclear Licensing | Respectf lly, eesident, Nuclear Licensing | ||
==Enclosure:== | ==Enclosure:== | ||
Description of Revisions for the Sequoyah Nuclear Plant (SQN), Technical Requirements Manual and SQN, Units 1 and 2 Technical Specification Bases cc (Enclosure): | |||
NRC Regional Administrator-Region II NRC Senior Resident Inspector - Sequoyah Nuclear Plant | |||
ENCLOSURE DESCRIPTION OF REVISIONS FOR THE SEQUOYAH NUCLEAR PLANT (SQN), | |||
TECHNICAL REQUIREMENTS MANUAL AND SQN, UNITS I AND 2 TECHNICAL SPECIFICATION BASES Technical Requirements Manual Revisions Technical Requirements Manual (TRM) Revision 47 was approved on September 27, 2012, and implemented on October 5, 2012. A change was made to TR 3.1.2.2, "Flow Paths - Operating," | |||
and TR 3.1.2.4, "Charging Pumps - Operating," to allow an operational provision similar to the technical specifications (TSs) allowance for temporarily disabling one half of the boron injection function of the Chemical and Volume Control System (i.e., one charging pump and associated flow path) to support transition between Modes 3 and 4. Provisions are provided in the TSs that allow the Emergency Core Cooling System (ECCS) pumps to be made incapable of injecting, in Mode 3, for a limited amount of time or system conditions to support Low Temperature Over Pressure Protection (LTOP) System operations. This provision prevents TS non-compliance when entering into and out of Mode 3 when two charging pumps are required to be operable. | |||
This change aligns the TRM to be consistent with the TSs for support of LTOP System operations. | |||
On May 15, 2007, TRM Revision 37 was reported to NRC. TRM Revision 37 was in support of SQN TS Amendment Nos. 305 for Unit 1 and 295 for Unit 2. A typographical error has been identified involving symbol characters with the issued page for TR 3.3.3.2, "Moveble Incore Detectors." The corrected page is submitted herein without change to the revision bar. | |||
Technical Specification Bases Revisions Revision 38 to the SQN, Units 1 and 2 Technical Specification (TS) Bases was approved on March 24, 2012, and implemented on March 26, 2012. The revision was in light of TS Change 07-05, "Emergency Core Cooling Systems (ECCS)" for SQN, Units 1 and 2,and associated with TS Amendment Nos. 326 and 319 approved on January 28, 2010. TS Bases Section 3.5.3, "ECCS - Shutdown," was revised to support primary and secondary residual heat removal check valve testing during Mode 4 operation. The changes differentiated TS Bases Section 3.5.2, "ECCS - Operating," Mode 1 through 3 safety analysis conditions from Mode 4 conditions, defines the necessary ECCS operation and flow paths, and added a reference. | |||
Revision 39 to the SQN Unit 1 TS Bases was approved on October 5, 2012, and implemented on October 25, 2012. This revision was in concert with TS Amendment No. 330. Limiting Condition for Operation (LCO), 3.7.5 "Ultimate Heat Sink," was amended to support maintenance activities during the Unit 2 refueling outage No. 18. The TS Bases were changed to identify additional LCO restrictions with respect to maximum average Essential Raw Cooling Water (ERCW) system supply header water temperature during large heavy load lifts performed to support the refueling outage. | |||
Revision 40 to the Unit 1 and Revision 39 to the Unit 2 TS Bases were approved on October 10, 2012. Unit 2 was implemented on November 28, 2012 during its refueling outage. Unit 1 will implement this revision during its next refueling outage in the Fall of 2013; therefore is not provided in this update. These TS Bases revisions are associated with TS Amendment Nos. | |||
331 and 324 for approved TS Change 11-07, "Application to Modify Technical Specifications for Use of AREVA Advanced W17 HTP Fuel." This change affected TS Bases Section 2.1, "Safety E1-1 | |||
Limits," and Section 3/4.2.5, "DNB Parameters," as it provided clarifications associated with the evaluation methodology for the new fuel design. | |||
Revision 40 to the Unit 2 TS Bases was approved on October 5, 2012, and implemented on November 2, 2012. This TS Bases revision to Section 3/4.4.5, "Reactor Coolant System," and Section 3/4.4.6.2, "Operation Leakage," was associated with replacement of the Unit 2 steam generators. The revision is associated with TS Amendment No. 323, in which previously approved steam generator inspections, specific repair criteria and reporting requirements had been modified or removed. | |||
Revision 41 to the SQN, Units 1 and 2 Bases was approved on December 21, 2012, and implemented on December 27, 2012. This revision incorporated changes to the Bases for Specification 3.8.1, "A. C. Sources," to describe a new surveillance requirement approved under TS Amendment Nos. 332 and 325 for Units 1 and 2, respectively. Other changes to the TS Bases section include example descriptions of offsite power configurations that would meet the requirements of TS LCO 3.8.1.1.a. | |||
Revision 42 to the SQN, Units 1 and 2 Bases was approved on March 5, 2013, and implemented on March 25, 2013. TS Bases Section 3/4.3.3.7, "Accident Monitoring Instrumentation," was revised. Statements describing accident monitoring instrumentation, specifically the SQN hydrogen monitoring channels were deleted. This change was associated with TS Amendment Nos. 296 and 286 for Units 1 and 2, respectively, which eliminated the requirements for hydrogen recombiners and hydrogen monitoring. | |||
Also, enclosed is a typographical correction to TS Bases Table B 3/4.4-1, SQN Unit 1 Reactor Vessel Toughness Data with no indication of a revision bar. This change corrects the value of nickel in the weld material of the reactor vessel. | |||
Attachments: | |||
: 1. | |||
Sequoyah Nuclear Plant, Technical Requirements Manual - Changed Pages | |||
: 2. | |||
Sequoyah Nuclear Plant, Unit 1, Technical Specification Bases - Changed Pages | |||
: 3. | |||
Sequoyah Nuclear Plant, Unit 2, Technical Specification Bases - Changed Pages E1-2 | |||
,1 ATTACHMENT I SEQUOYAH NUCLEAR PLANT TECHNICAL REQUIREMENTS MANUAL CHANGED PAGES TRM Affected Pages EPL-1 EPL-2 EPL-5 EPL-8 Index Page III 3/4 1-3 through 3/4 1-13 3/4 3-2 B 3/4 1-2 B 3/4 1-3 | |||
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL REQUIREMENTS MANUAL EFFECTIVE PAGE LISTING Page Revision Index Page I 09/28/03 Index Page II 02/02/98 Index Page III 09/27/12 Index Page IV 01/20/06 Index Page V 01/20/06 Index Page VI 01/20/06 Index Page VII 02/02/98 Index Page VIII 02/02/98 1-1 02/02/98 1-2 05/18/09 1-3 09/28/03 1-4 07/19/02 1-5 07/25/02 1-6 02/02/98 1-7 02/02/98 1-8 02/02/98 3/4 0-1 05/27/05 3/4 0-2 05/27/05 3/4 0-3 07/25/06 3/4 0-4 07/25/06 3/4 1-1 01/04/01 3/4 1-2 10/12/05 EPL-1 September 27, 2012 | |||
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL REQUIREMENTS MANUAL EFFECTIVE PAGE LISTING Paqe Revision 3/4 1-3 09/27/12 3/4 1-4 09/27/12 3/4 1-5 09/27/12 3/4 1-6 09/27/12 3/4 1-7 09/27/12 3/4 1-9 09/27/12 3/4 1-10 09/27/12 3/4 1-11 09/27/12 3/4 1-12 09/27/12 3/4 1-13 09/27/12 3/4 3-1 01/20/06 3/4 3-2 01/20/06 3/4 3-3 01/20/06 3/4 3-4 01/20/06 3/4 3-5 01/20/06 3/4 3-6 10/17/06 3/4 3-7 04/26/06 3/4 3-8 04/26/06 3/4 3-9 01/20/06 3/4 3-10 01/20/06 3/44-1 01/20/06 3/4 4-2 01/20/06 3/4 4 01/20/06 EPL-2 September 27, 2012 | |||
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL REQUIREMENTS MANUAL EFFECTIVE PAGE LISTING Page Revision B 3/4 1-1 01/04/01 B 3/4 1-2 Through B 3/4 1-3 09/27/12 B 3/4 1-4 Through B 3/4 1-6 01/04/01 B 3/4 3-1 01/20/06 B 3/4 3-2 01/20/06 B 3/4 3-3 01/20/06 B 3/4 3-4 01/20/06 B 3/4 3-5 01/20/06 B 3/4 3-6 01/20/06 B 3/4 3-7 01/20/06 B 3/4 3-8 01/20/06 B 3/4 3-9 01/20/06 B 3/4 3-10 01/20/06 B 3/4 3-11 01/20/06 B 3/4 3-12 01/20/06 B 3/4 3-13 01/20/06 B 3/4 3-14 01/20/06 B 3/4 4-1 01/20/06 B 3/4 4-2 01/20/06 B 3/4 4-3 01/20/06 EPL-5 September 27, 2012 | |||
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL REQUIREMENTS MANUAL REVISION LISTING Revision Date Initial Issue, Revision 0 02/02/98 Revision 1 10/01/98 Revision 2 02/12/99 Revision 3 03/18/99 Revision 4 09/14/99 Revision 5 10/24/99 Revision 6 09/29/99 Revision 7 12/09/99 Revision 8 03/23/00 Revision 9 06/02/00 Revision 10 06/13/00 Revision 11 06/15/00 Revision 12 11/09/00 Revision 13 01/04/01 Revision 14 04/05/01 Revision 15 07/11/01 Revision 16 04/05/02 Revision 17 03/27/02 Revision 18 07/19/02 Revision 19 07/25/02 Revision 20 10/11/02 Revision 21 03/06/03 Revision 22 08/11/03 Revision 23 09/14/03 Revision 24 09/28/03 Revision 25 10/31/03 Revision 26 09/26/03 Revision 27 09/26/03 Revision 28 05/15/04 Revision 29 10/13/04 Revision 30 10/13/04 Revision 31 04/22/05 Revision 32 05/27/05 Revision 33 06/20/05 Revision 34 06/24/05 Revision 35 10/12/05 Revision 36 10/19/05 Revision 37 01/20/06 Revision 38 03/08/06 Revision 39 03/17/06 Revision 40 04/26/06 Revision 41 07/25/06 Revision 42 09/15/06 Revision 43 10/17/06 Revision 44 11/14/06 Revision 45 05/18/09 Revision 46 11/29110 Revision 47 09/27/12 EPL-8 September 27, 2012 | |||
INDEX TECHNICAL REQUIREMENTS SECTION PAGE T R 3/4.0 A P P LIC A B ILIT Y................................................................................................................. | |||
3/4 0-1 TR 3/4.1 REACTIVITY CONTROL SYSTEMS T R 3/4.1.1 (N o current requirem ents).................................................................................................. | |||
3/4 1-1 TR 3/4.1.2 BORATION SYSTEMS TR 3/4.1.2.1 FLOW PATHS - SHUTDOW N........................................................................... | |||
3/4 1-2 TR 3/4.1.2.2 FLOW PATHS - O PERATING........................................................................... | |||
3/4 1-3 TR 3/4.1.2.3 CHARGING PUMP - SHUTDOWN.................................................................... | |||
3/4 1-5 TR 3/4.1.2.4 CHARGING PUMPS - OPERATING................................................................. | |||
3/4 1-6 TR 3/4.1.2.5 BORATED WATER SOURCES - SHUTDOWN................................................ | |||
3/4 1-7 TR 3/4.1.2.6 BORATED WATER SOURCES - OPERATING................................................ | |||
3/4 1-9 TR 3/4.1.3.1 Through TR 3/4.1.3.2 (No current requirements)......................................................... | |||
3/4 1-12 TR 3/4.1.3.3 POSITION INDICATION SYSTEM - SHUTDOWN...................................................... | |||
3/4 1-13 TR 3/4.2 POWER DISTRIBUTION LIMITS No current requirements TR 3/4.3 INSTRUMENTATION TR 3/4.3.1 Through TR 3/4.3.3.1 (No current requirements).............................................................. | |||
3/4 3-1 TR 3/4.3.3 MONITORING INSTRUMENTATION TR 3/4.3.3.2 MOVABLE INCORE DETECTORS................................................................... | |||
3/4 3-2 TR 3/4.3.3.3 SEISMIC INSTRUMENTATION........................................................................ | |||
3/4 3-3 TR 3/4.3.3.4 METEOROLOGICAL INSTRUMENTATION..................................................... | |||
3/4 3-6 TR 3/4.3.3.5 Through TR 3/4.3.3.14 (No current requirements)........................................... | |||
3/4 3-9 TR 3/4.3.3.15 PLANT CALORIMETRIC MEASURMENT.................................................... | |||
Revision | 3/4 3-10 TR 3/4.4 REACTOR COOLANT SYSTEM TR 3/4.4.1 Through TR 3/4 4.6 (No current requirements)................................................................. | ||
3/4 4-1 T R 3/4 4.7 C H E M IS T R Y...................................................................................................................... | |||
3/4 4-2 TR 3/4.4.8 Through TR 3/4 4.9.1 (No current requirements).............................................................. | |||
3/4 4-5 TR 3/4 4.9.2 PRESSURIZER TEMPERATURE LIMITS..................................................................... | |||
3/4 4-6 T R 3/4.4.10 (N o current requirem ents)................................................................................................ | |||
3/4 4-7 TR 3/4 4.11 REACTOR COOLANT SYSTEM HEAD VENTS............................................................. | |||
3/4 4-8 TR 3/4.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) | |||
3/4 | No current requirements SEQUOYAH - UNITS 1 AND 2 III September 27, 2012 TECHNICAL REQUIREMENTS Revision Nos. 1, 3-5, 8-13, 16, 17, 20, 23, 29,30,31,37,47 | ||
REACTIVITY CONTROL SYSTEMS FLOW PATHS - OPERATING LIMITING CONDITION FOR OPERATION TR 3.1.2.2 At least two of the following three boron injection flow paths shall be OPERABLE: | |||
................................................................ | : a. | ||
3 | The flow path from the boric acid tanks via a boric acid transfer pump and a charging pump to the Reactor Coolant System. | ||
.................................................................... | : b. | ||
Two flow paths from the refueling water storage tank via charging pumps to the Reactor Coolant System. | |||
................................................................. | |||
................................................ | |||
................................................ | |||
3/4 | |||
......................................................... | |||
3/4 | |||
...................................................... | |||
.............................................................. | |||
................................... | |||
NNOT---------------- | NNOT---------------- | ||
In MODE 3, one charging pump may be made incapable of injecting to support transition into or from the APPLICABILITY of Technical Specification LCO 3.4.12, "Low Temperature Overpressure Protection (LTOP) System," for up to 4 hours or until the temperature of all RCS cold legs exceeds LTOP arming temperature (350°F) specified in the Pressure and Temperature Limits Report (PTLR) plus 250F, whichever comes first. | |||
APPLICABILITY: MODES 1, 2, and 3. | |||
ACTION: | |||
With only one of the above required boron injection flow paths to the Reactor Coolant System OPERABLE, restore at least two boron injection flow paths to the Reactor Coolant System to OPERABLE status within 72 hours or be in at least HOT STANDBY and borated to a SHUTDOWN MARGIN equivalent to at least 1% delta k/k at 200OF within the next 6 hours; restore at least two flow paths to OPERABLE status within the next 7 days or be in HOT SHUTDOWN within the next 30 hours. | |||
SURVEILLANCE REQUIREMENTS TR 4.1.2.2 At least two of the above required flow paths shall be demonstrated OPERABLE: | |||
: a. | |||
At least once per 7 days by verifying that the temperature of the areas containing flow path components from the boric acid tanks to the blending tee is greater than or equal to 630F when it is a required water source. | |||
: b. | |||
Whenever the area temperature(s) is(are) less than 63 0F and the boric acid tank is a required water source | |||
A508,C1.2 | A508,C1.2 | ||
+ 5 +36 +56* +5 125a | + 5 | ||
--- | +36 | ||
--- | +56* | ||
+5 125a Hd Flange 4842 A508,C1.2 | |||
-22 +16 +36* -22 118a | -40 | ||
-67 +9 +29* -31 94a | -24 | ||
-49 +21 +41* -19 948 | -4* | ||
-58 +30 +50* -10 79.5a | -40 131a Vessel Flange 4866 A508,C1.2 | ||
-58 +16 +36* -24 103a | -49 | ||
-49 0 +20 -40 126a | -47 | ||
-40 +43 +83 +23 83a 113'Inter Shell 4829 A508,C1.2 0.15 0.86 -4 +10 +100 +40 116 73b' | -27 | ||
-49 158a Inlet Nozzle 4846 A508,CI.2 | |||
-58 | |||
+25 | |||
--- | +45 | ||
-15 94.5a Inlet Nozzle 4949 A508,C1.2 | |||
-40 | |||
--- | +39 | ||
* Estimate based on USAEC Regulatory Standard Review Plan, Section 5.3. | +59* | ||
-1 93a Inlet Nozzle 4863 A508,C1.2 | |||
In MODE 4,the required ECCS train consists of two separate subsystems: | -22 | ||
centrifugal charging (high head) and residual heat removal (RHR) ( | +16 | ||
It is understood in | +36* | ||
In this MODE, sufficient time exists for manual .actuation of | -22 118a Inlet Nozzle 4865 A508,C1.2 | ||
One train of ECCS during the injection phase provides sufficient flow | -67 | ||
+9 | |||
ECCS trains | +29* | ||
-UNIT | -31 94a Outlet Nozzle 4845 A508,C1.2 | ||
In MODE 4, an ECCS train consists of a centrifugal charging subsystem and an RHR subsystem. | -49 | ||
Each train includes the piping, instruments, | +21 | ||
In the long term, this flow path may be switched | +41* | ||
This LCO is modified by a Note that allows an RHR train to be considered OPERABLE during alignment and operation for decay heat removal, | -19 948 Outlet Nozzle 4850 A508,C1.2 | ||
The manual | -58 | ||
In MODES 5 and 6, plant conditions are such that the probability of | +30 | ||
MODE 6 core cooling requirements | +50* | ||
-All Water Levels," | -10 79.5a Outlet Nozzle 4862 A508,C1.2 | ||
and LCO 3.9.8.2 "Residual Heat | -58 | ||
-Low Water Level."March 24, | +16 | ||
-UNIT 1 B 3/4 5-13 BR35, BR36, BR38 ECCS - | +36* | ||
A second Note allows the required ECCS RHR subsystem to | -24 103a Outlet Nozzle 4864 A508,C1.2 | ||
This allows testing while | -49 0 | ||
The condition requiring manual realignment capability, FCV-74-1 and FCV-74-2 can be | +20 | ||
-40 126a Upper Shell 4841 A508,C1.2 | |||
-40 | |||
The action time of immediately | +43 | ||
+83 | |||
The alternate means | +23 83a 113' Inter Shell 4829 A508,C1.2 0.15 0.86 | ||
With both RHR pumps and heat exchangers inoperable, it would | -4 | ||
-UNIT 1 B 3/4 5-14 BR35 | +10 | ||
Action b.With no ECCS high head subsystem | +100 | ||
+40 116 73b'c Lower Shell 4836 A508,C1.2 0.13 0.76 | |||
When Action b cannot be completed within the required action time,within one hour, a controlled shutdown should be initiated. | +5 | ||
Twenty | +28 | ||
SURVEILLANCE SR 4.5. | +133 | ||
: 1. The applicable references from Bases 3.5.2 apply.2. NRC Safety Evaluation Report, NUREG-001 1, Section 1.1,"Introduction," | +73 109 70b Trans. Ring 4879 A508,CI.2 | ||
regarding Amendment 49 dated January 6, 1978.March 24, | +5 | ||
-UNIT | +27 | ||
These assumptions | +47* | ||
+ 5 98a Bot. Hd. Rim 52703/2-1 A533B,C1.1 | |||
-31 | |||
+23 | |||
+43* | |||
-17 104a Bot. Hd. Rim 52703/2-2 A533B,C1.1 | |||
-13 | |||
+36 | |||
+56* | |||
-4 638 Bot. Hd. Rim 52704/2 A533B,C1.1 | |||
-49 | |||
-24 | |||
-4* | |||
-49 114a Bot. Hd. Rim 52703/2-2 A533B,C1.1 | |||
-31 | |||
+43 | |||
+63* | |||
+3 86a Bot. Hd. Rim 52704/2 A533B,C1.1 | |||
-58 | |||
-13 | |||
+4 | |||
-53 120a Bot. Hd. | |||
52704/11 A533B,C1.1 | |||
-58 | |||
-47 | |||
-27* | |||
-58 139a Weld Weld 0.33 0.17 | |||
-40 | |||
-4 | |||
-40 116b HAZ Weld | |||
-22 | |||
+41 | |||
-19 86b 1-Paralled to Major Working Direction 2-Normal to Major Working Direction a-%Shear Not reported b-Minimum upper shelf energies c-Minimum upper shelf energy decreased to 51 at a test temperature of 3000F. This anomaly will be reevaluted when the results of Generic task A-i 1 are available. | |||
* Estimate based on USAEC Regulatory Standard Review Plan, Section 5.3.2 MTEB November 9, 2004 Amendment No. 158, 294, 297 SEQUOYAH UNIT 1 B 3/4 4-12 | |||
ECCS - Shutdown B 3/4.5.3 B 3/4.5 EMERGENCY CORE COOLING SYSTEM (ECCS) | |||
B 3/4.5.3 ECCS - Shutdown BASES BACKGROUND The Background section for Bases 3.5.2, "ECCS - Operating," is applicable to these Bases, with the following modifications. In MODE 4, the required ECCS train consists of two separate subsystems: centrifugal charging (high head) and residual heat removal (RHR) (low head). For the RHR subsystem during the injection phase, water is taken from the refueling storage tank (RWST) and injected in the Reactor Coolant System (RCS) through at least two cold legs. | |||
The ECCS flow paths consist of piping, valves, heat exchangers, and pumps such that water from the refueling water storage tank (RWST) can be injected into the Reactor Coolant System (RCS) following the accidents described in Bases 3.5.2. | |||
APPLICABLE SAFETY ANALYSES The Applicable Safety Analyses section of Bases 3.5.2 also applies to this Bases section. | |||
Due to the stable conditions associated with operation in MODE 4 and the reduced probability of occurrence of a Design Basis Accident (DBA), the ECCS operational requirements are reduced. It is understood in these reductions that certain automatic safety injection (SI) actuation is not available. In this MODE, sufficient time exists for manual.actuation of the required ECCS to mitigate the consequences of a DBA. | |||
Only one train of ECCS is required for MODE 4. This requirement dictates that single failures are not considered during this MODE of operation. | |||
One train of ECCS during the injection phase provides sufficient flow for core cooling, by the centrifugal charging subsystem supplying each of the four cold legs and the RHR subsystem supplying at least two cold legs, to meet the analysis requirements for a credible Mode 4 Loss of Coolant Accident (LOCA.) | |||
The ECCS trains satisfy Criterion 3 of 10 CFR 50.36(c)(2)(ii). | |||
LCO In MODE 4, one of the two independent (and redundant) ECCS trains is required to be OPERABLE to ensure that sufficient ECCS flow is available to the core following a DBA. | |||
SEQUOYAH - UNIT 1 March 24, 2012 BR35, BR38 B 3/4 5-12 | |||
ECCS - Shutdown B 3/4.5.3 BASES LCO (continued) | |||
In MODE 4, an ECCS train consists of a centrifugal charging subsystem and an RHR subsystem. Each train includes the piping, instruments, and controls to ensure an OPERABLE flow path capable of taking suction from the RWST and transferring suction to the containment sump During an event requiring ECCS actuation, a flow path is required to provide an abundant supply of water from the RWST to the RCS via the ECCS pumps and their respective supply headers to the cold leg injection nozzles. In the long term, this flow path may be switched to take its supply from the containment sump and to deliver its flow to the RCS hot and cold legs. | |||
Either RHR cold leg injection valve FCV-63-93 or FCV-63-94 may be closed when in Mode 4, for testing of the primary/secondary check valves in the injection lines. Closing one of the two cold leg injection flow paths does not make ECCS RHR subsystem inoperable. | |||
This LCO is modified by a Note that allows an RHR train to be considered OPERABLE during alignment and operation for decay heat removal, if capable of being manually realigned (remote or local) to the ECCS mode of operation and not otherwise inoperable. The manual actions necessary to realign the RHR subsystem may include actions to cool the RHR system piping due to the potential for steam voiding in piping or for inadequate NPSH available at the RHR pumps. This allows operation in the RHR mode during MODE 4. | |||
APPLICABILITY In MODES 1, 2, and 3, the OPERABILITY requirements for ECCS are covered by LCO 3.5.2. | |||
In MODE 4 with RCS temperature below 350°F, one OPERABLE ECCS train is acceptable without single failure consideration, on the basis of the stable reactivity of the reactor and the limited core cooling requirements. | |||
In MODES 5 and 6, plant conditions are such that the probability of an event requiring ECCS injection is extremely low. Core cooling requirements in MODE 5 are addressed by LCO 3.4.1.4, "Reactor Coolant System Cold Shutdown." MODE 6 core cooling requirements are addressed by LCO 3.9.8.1 "Residual Heat Removal and Coolant Circulation - All Water Levels," and LCO 3.9.8.2 "Residual Heat Removal and Coolant Circulation - Low Water Level." | |||
March 24, 2012 SEQUOYAH - UNIT 1 B 3/4 5-13 BR35, BR36, BR38 | |||
ECCS - Shutdown B 3/4.5.3 BASES ACTIONS A Note prohibits the application of LCO 3.0.4b to an inoperable ECCS high head subsystem when entering MODE 4. There is an increased risk associated with entering MODE 4 from MODE 5 with an inoperable ECCS high head subsystem and the provisions of LCO 3.0.4b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance. | |||
A second Note allows the required ECCS RHR subsystem to be inoperable because of surveillance testing of RCS pressure isolation valve leakage (FCV-74-1 and FCV-74-2). This allows testing while RCS pressure is high enough to obtain valid leakage data and following valve closure for RHR decay heat removal path. The condition requiring alternate heat removal methods ensures that the RCS heatup rate can be controlled to prevent MODE 3 entry and thereby ensure that the reduced ECCS operational requirements are maintained. The condition requiring manual realignment capability, FCV-74-1 and FCV-74-2 can be opened from the main control room ensures that in the unlikely event of a DBA during the one hour of surveillance testing, the RHR subsystem can be placed in ECCS recirculation mode when required to mitigate the event. | |||
Action a. | |||
With no ECCS RHR subsystem OPERABLE, the plant is not prepared to respond to a loss of coolant accident or to continue a cooldown using the RHR pumps and heat exchangers. The action time of immediately to initiate actions that would restore at least one ECCS RHR subsystem to OPERABLE status ensures that prompt action is taken to restore the required cooling capacity. Normally, in MODE 4, reactor decay heat is removed from the RCS by an RHR loop. If no RHR loop is OPERABLE for this function, reactor decay heat must be removed by some alternate method, such as use of the steam generators. The alternate means of heat removal must continue until the inoperable RHR loop components can be restored to operation so that decay heat removal is continuous. | |||
With both RHR pumps and heat exchangers inoperable, it would be unwise to require the plant to go to MODE 5, where the only available heat removal system is the RHR. Therefore, the appropriate action is to initiate measures to restore one ECCS RHR subsystem and to continue the actions until the subsystem is restored to OPERABLE status. | |||
March 24, 2012 SEQUOYAH - UNIT 1 B 3/4 5-14 BR35 | |||
BASES ACTIONS (continued) | |||
Action b. | |||
With no ECCS high head subsystem OPERABLE, due to the inoperability of the centrifugal charging pump or flow path from the RWST, the plant is not prepared to provide high pressure response to Design Basis Events requiring SI. The 1 hour action time to restore at least one ECCS high head subsystem to OPERABLE status ensures that prompt action is taken to provide the required cooling capacity or to initiate actions to place the plant in MODE 5, where an ECCS train is not required. | |||
When Action b cannot be completed within the required action time, within one hour, a controlled shutdown should be initiated. Twenty four hours is a reasonable time, based on operating experience, to reach MODE 5 in an orderly manner and without challenging plant systems or operators. | |||
SURVEILLANCE SR 4.5.3 REQUIREMENTS The applicable Surveillance descriptions from Bases 3.5.2 apply. | |||
REFERENCES | |||
: 1. The applicable references from Bases 3.5.2 apply. | |||
: 2. NRC Safety Evaluation Report, NUREG-001 1, Section 1.1, "Introduction," regarding Amendment 49 dated January 6, 1978. | |||
March 24, 2012 BR35, BR38 SEQUOYAH - UNIT 1 B 3/4 5-15 | |||
EMERGENCY CORE COOLING SYSTEMS BASES 3/4.5.4 BORON INJECTION SYSTEM This specification was deleted. | |||
3/4.5.5 REFUELING WATER STORAGE TANK The OPERABILITY of the RWST as part of the ECCS ensures that a sufficient supply of borated water is available for injection by the ECCS in the event of a LOCA. The limits on RWST minimum volume and boron concentration ensure that 1) sufficient water is available within containment to permit recirculation cooling flow to the core, and 2) the reactor will remain subcritical in the cold condition following mixing of the RWST and the RCS water volumes with all control rods inserted except for the most reactive control assembly. These assumptions are consistent with the LOCA analyses. | |||
Additionally, the OPERABILITY of the RWST as part of the ECCS ensures that sufficient negative reactivity is injected into the core to counteract any positive increase in reactivity caused by RCS cooldown. | Additionally, the OPERABILITY of the RWST as part of the ECCS ensures that sufficient negative reactivity is injected into the core to counteract any positive increase in reactivity caused by RCS cooldown. | ||
The contained water volume limit includes an allowance for water not usable because of tank discharge line location or other physical characteristics. | |||
The limits on contained water volume and boron concentration of the RWST also ensure a pH value of between 7.5 and 9.5 for the solution recirculated within containment after a LOCA. | |||
This pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion on mechanical systems and components. | |||
March 24, 2012 SEQUOYAH - UNIT 1 B 3/4 5-16 Amendment No. 140, 301 | |||
EMERGENCY CORE COOLING SYSTEM BASES 3/4.5.6 SEAL INJECTION FLOW BACKGROUND The function of the seal injection throttle valves during an accident is similar to the function of the ECCS throttle valves in that each restricts flow from the centrifugal charging pump header to the Reactor Coolant System (RCS). | |||
The restriction on reactor coolant pump (RCP | |||
==References:== | ==References:== | ||
ASTM Standards D4057-1988, "Practice for manual sampling of petroleum and petroleum Products." | |||
D975-1990, "Standard Specifications for Diesel Fuel oils." | |||
D4176-1986, "Free Water and Particulate Contamination in Distillate Fuels." | |||
D1552-1990, "Standard Test Method for Sulfur in Petroleum Products (High Temperature Method)." | |||
December 21, 2012 SEQUOYAH - UNIT 1 B 3/4 8-8 Amendment No.12, 137, 250, 261 | |||
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued) | |||
D2622-1987, "Standard Test Method for Sulfur in Petroleum Products (X-Ray Spectrographic Method)." | D2622-1987, "Standard Test Method for Sulfur in Petroleum Products (X-Ray Spectrographic Method)." | ||
D2276-1994, "Standard Test Method for Particulate Containment in Aviation Turbine Fuels." | |||
D1298-1985, "Standard Test Method for Density, Specific Gravity, or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method." | |||
3/4.8.3 ELECTRICAL EQUIPMENT PROTECTIVE DEVICES This specification is deleted. | |||
December 21, 2012 Amendment No.12, 137, 250, 261 SEQUOYAH - UNIT 1 B 3/4 8-9 | |||
ATTACHMENT 3 SEQUOYAH NUCLEAR PLANT, UNIT 2 TECHNICAL SPECIFICATION BASES CHANGED PAGES TS Bases Affected Pages EPL Page 2 EPL Page 3 EPL Page 16 EPL Page 17 EPL Page 19 EPL Page 20 EPL Page 21 EPL Page 22 EPL Page 31 EPL Page 32 Index Page III Index Page XIV B 2-1 | |||
On decreasing power, the opposite function is performed at reset setpoints. | On decreasing power, the opposite function is performed at reset setpoints. | ||
P-4 Reactor-tripped | P-4 Reactor-tripped - Actuates turbine trip, closes main feedwater valves on Tav, below setpoint, prevents the opening of the main feedwater valves which were closed by a safety injection or high steam generator water level signal, allows manual block of the automatic reactuation of safety injection. | ||
-Actuates turbine trip, closes main feedwater valves on Tav, below setpoint, prevents the opening of the | Reactor not tripped - defeats manual block preventing automatic reactuation of safety injection. | ||
Reactor not tripped -defeats manual block preventing automatic reactuation of safety injection. | October 10, 2012 SEQUOYAH - UNIT 2 B 2-11 Amendment No. 132 | ||
October 10, | |||
-UNIT 2 B 2-11 Amendment No. 132 POWER DISTRIBUTION | POWER DISTRIBUTION LIMITS BASES 3/4.2.4 QUADRANT POWER TILT RATIO The QUADRANT POWER TILT RATIO limit assures that no anomaly exists such that the radial power distribution satisfies the design values used in the power capability analysis. Radial power distribution measurements are made during startup testing and periodically during power operation. | ||
Radial | The QUADRANT POWER TILT RATIO limit at which corrective action is required provides DNB and linear heat generation protection with x-y plane power tilts. The QUADRANT POWER TILT RATIO limit is reflected by a corresponding peaking augmentation factor which is included in the generation of the AFD limits. | ||
The QUADRANT POWER TILT RATIO limit at which corrective action is required provides | The 2-hour time allowance for operation with the tilt condition greater than 1.02 but less than 1.09, is provided to allow identification and correction of a dropped or misaligned control rod. In the event such action does not correct the tilt, the margin for uncertainty on FQ(X,Y,Z) is reinstated by reducing the allowable THERMAL POWER by 3 percent for each percent of tilt in excess of 1.02. | ||
The limits are consistent with the initial FSAR assumptions and have been analytically demonstrated adequate to maintain a minimum DNBR of greater than or equal to the safety analysis DNBR | 3/4.2.5 DNB PARAMETERS The limits on the DNB related parameters assure that each of the parameters are maintained within the normal steady state envelope of operation assumed in the transient and accident analyses. | ||
The 12 hour periodic surveillance of these parameters through instrument readout is sufficient | The limits are consistent with the initial FSAR assumptions and have been analytically demonstrated adequate to maintain a minimum DNBR of greater than or equal to the safety analysis DNBR limit throughout each analyzed transient. | ||
October 10, | The 12 hour periodic surveillance of these parameters through instrument readout is sufficient to ensure that the parameters are restored within their limits following load changes and other expected transient operation. | ||
-UNIT 2 B 3/4 2-4 Amendment 21, 130, 146, 214, 324 INSTRUMENTATION | October 10, 2012 SEQUOYAH - UNIT 2 B 3/4 2-4 Amendment 21, 130, 146, 214, 324 | ||
INSTRUMENTATION BASES ACCIDENT MONITORING INSTRUMENTATION (Continued) | |||
Determine whether systems important to safety are performing their intended functions. | Determine whether systems important to safety are performing their intended functions. | ||
Provide information to the operators that will enable them to determine the likelihood of a | Provide information to the operators that will enable them to determine the likelihood of a gross breach of the barriers to radioactivity release and to determine if a gross breach of a barrier has occurred. | ||
For Sequoyah, the redundant channel capability for Auxiliary Feedwater (AFW) flow consists of | For Sequoyah, the redundant channel capability for Auxiliary Feedwater (AFW) flow consists of a single AFW flow channel for each Steam Generator with the second channel consisting of three AFW valve position indicators (two level control valves for the motor driven AFW flowpath and one level control valve for the turbine drive AFW flowpath) for each steam generator. | ||
March 5, | March 5, 2013 SEQUOYAH - UNIT 2 B 3/4 3-3a Amendment Nos. 135, 149 | ||
-UNIT 2 B 3/4 3-3a Amendment Nos. 135, 149 RCS Leakage Detection Instrumentation B 3/4.4. | |||
The analysis of an SGTR event assumes a | RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES APPLICABLE SAFETY ANALYSES The steam generator tube rupture (SGTR) accident is the limiting design basis event for SG tubes and avoiding an SGTR is the basis for this specification. The analysis of an SGTR event assumes a bounding primary to secondary leakage rate equal to the operational leakage rate limits in LCO 3.4.6.2 "Operational Leakage," plus the leakage rate associated with a double-ended rupture of a single tube. The accident analysis for a SGTR assumes the contaminated secondary fluid is released to the atmosphere via safety valves. The main condenser isolates based on an assumed concurrent loss of off-site power. | ||
plus the leakage | The analysis for design basis accidents and transients other than a SGTR assume the SG tubes retain their structural integrity (i.e., they are assumed not to rupture). In these analyses, the steam discharge to the atmosphere depends on the accident and whether there are faulted SGs associated with the accident. For a steamline break (SLB), the maximum primary to secondary leakage under accident conditions is limited to 3.7 gpm from the faulted SG and 0.1 gpm from each of the non-faulted SGs. | ||
In these analyses, the steam discharge to | For other accidents that assume a faulted SG (e.g., feedwater line break), the maximum primary to secondary leakage under accident conditions is limited to 1.0 gpm from the faulted SG and 0.1 gpm from each of the non-faulted SGs. For accidents in which there are no faulted SGs, the primary to secondary leakage is limited to 0.1 gpm from each SG. For accidents that do not involve fuel damage, the primary coolant activity level of DOSE EQUIVALENT 1-131 is assumed to be equal to the LCO 3.4.8, "Specific Activity," limits. For accidents that assume fuel damage, the primary coolant activity is a function of the amount of activity released from the damaged fuel. The dose consequences of these events are within the limits of GDC 19 (Ref. 2), and 10 CFR 100 (Ref. 3). | ||
For a steamline break (SLB), the | Steam generator tube integrity satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii). | ||
limits. For accidents that assume | LCO The LCO requires that SG tube integrity be maintained. The LCO also requires that all SG tubes that satisfy the repair criteria be plugged in accordance with the Steam Generator Program. | ||
LCO The LCO requires that SG tube integrity be maintained. | During an SG inspection, any inspected tube that satisfies the Steam Generator Program repair criteria is removed from service by plugging. If a tube was determined to satisfy the repair criteria but was not plugged, the tube may still have tube integrity. | ||
The LCO | SEQUOYAH - UNIT 2 B 3/4 4-3a October 5, 2012 Amendment No. 181, 211, 213, 243, 267, 291,305, 309, 318, 323 | ||
SEQUOYAH | RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES LCO (continued) | ||
-UNIT | In the context of this specification, a SG tube is defined as the entire length of the tube, including the tube wall, between the tube-to-tubesheet weld at the tube inlet and the tube-to-tubesheet weld at the tube outlet. | ||
In the context of this specification, a SG tube is defined as the | The tube-to-tubesheet weld is not considered part of the tube. | ||
The SG performance criteria are defined in Specification 6.8.4.k " | A SG tube has tube integrity when it satisfies the SG performance criteria. | ||
and describe acceptable SG tube performance. | The SG performance criteria are defined in Specification 6.8.4.k "Steam Generator Program," and describe acceptable SG tube performance. | ||
The Steam Generator Program also provides the evaluation process | The Steam Generator Program also provides the evaluation process for determining conformance with the SG performance criteria. | ||
There are three SG performance criteria: | There are three SG performance criteria: structural integrity, accident induced leakage, and operational leakage. Failure to meet any one of these criteria is considered failure to meet the LCO. | ||
structural integrity, | The structural integrity performance criterion provides a margin of safety against tube burst or collapse under normal and accident conditions, and ensures structural integrity of the SG tubes under all anticipated transients included in the design specification. Tube burst is defined as, "The gross structural failure of the tube wall. The condition typically corresponds to an unstable opening displacement (e.g., opening area increased in response to constant pressure) accompanied by ductile (plastic) tearing of the tube material at the ends of the degradation.' Tube collapse is defined as, "For the load displacement curve for a given structure, collapse occurs at the top of the load versus displacement curve where the slope of the curve becomes zero." The structural integrity performance criterion provides guidance on assessing loads that have a significant effect on burst or collapse. In that context, the term "significant" is defined as "An accident loading condition other than differential pressure is considered significant when the addition of such loads in the assessment of the structural integrity performance criterion could cause a lower structural limit or limiting burst/collapse condition to be established." For tube integrity evaluations, except for circumferential degradation, axial thermal loads are classified as secondary loads. For circumferential degradation, the classification of axial thermal loads as primary or secondary loads will be evaluated on a case-by-case basis. | ||
Failure to meet any one | The division between primary and secondary classifications will be based on detailed analysis and/or testing. | ||
Tube burst is defined as,"The gross structural failure of the tube wall. The condition typically corresponds to an unstable opening displacement (e.g., opening | October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3b Amendment No. 181, 211, 213, 243, 267, 291,305 | ||
In that context, the term"significant" is defined as "An accident loading condition other | RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES LCO (continued) | ||
For tube integrity evaluations, except for circumferential degradation, axial thermal loads are classified as secondary loads. | Structural integrity requires that the primary membrane stress intensity in a tube not exceed the yield strength for all American Society of Mechanical Engineers (ASME) Code, Section III, Service Level A (normal operating conditions), and Service Level B (upset or abnormal conditions) transients included in the design specification. This includes safety factors and applicable design basis loads based on ASME Code, Section III, Subsection NB (Ref. 4) and Draft Regulatory Guide 1.121 (Ref. 5). | ||
-UNIT 2 B 3/4 4-3b Amendment No. 181, 211, 213, 243,267, 291,305 RCS Leakage Detection Instrumentation B 3/4.4. | The accident induced leakage performance criterion ensures that the primary to secondary leakage caused by a design basis accident, other than a SGTR, is within the accident analysis assumptions. The accident analyses assumptions are discussed in the Applicable Safety Analyses section. The accident induced leakage rate includes any primary to secondary leakage existing prior to the accident in addition to primary to secondary leakage induced during the accident. | ||
Structural integrity requires that the primary membrane stress intensity | The operational leakage performance criterion provides an observable indication of SG tube conditions during plant operation. The limit on operational leakage is contained in LCO 3.4.6.2, "Operational Leakage," | ||
and Service Level B (upset or abnormal conditions) transients included in the design specification. | and limits primary to secondary leakage through any one SG to 150 gallons per day. This limit is based on the assumption that a single crack leaking this amount would not propagate to a SGTR under the stress conditions of a loss-of-coolant accident (LOCA) or a SLB. If this amount of leakage is due to more than one crack, the cracks are very small, and the above assumption is conservative. | ||
This includes | APPLICABILITY Steam generator tube integrity is challenged when the pressure differential across the tubes is large. Large differential pressures across SG tubes can only be experienced in MODES 1, 2, 3, or 4. | ||
The | Reactor coolant system (RCS) conditions are far less challenging in MODES 5 and 6 than during MODES 1, 2, 3, and 4. In MODES 5 and 6, primary to secondary differential pressure is low, resulting in lower stresses and reduced potential for leakage. | ||
The accident induced leakage rate includes any primary | October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3c Amendment No. 181, 211, 213, 243, 267, 291,305, 323 | ||
The operational leakage performance criterion provides an observable indication of SG tube conditions during plant operation. | |||
The limit | RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES ACTIONS The ACTIONs are modified by a clarifying footnote that Action (a) may be entered independently for each SG tube. This is acceptable because the actions provide appropriate compensatory measures for each affected SG tube. Complying with the actions may allow for continued operation, and subsequent affected SG tubes are governed by subsequent action entry, and application of associated actions. | ||
and limits primary to secondary leakage through any one SG to | Actions (a) and (b) | ||
APPLICABILITY Steam generator tube integrity is challenged when the | Action (a) applies if it is discovered that one or more SG tubes examined in an inservice inspection satisfy the tube repair criteria but were not plugged in accordance with the Steam Generator Program as required by SR 4.4.5.1. An evaluation of SG tube integrity of the affected tube(s) must be made. Steam generator tube integrity is based on meeting the SG performance criteria described in the Steam Generator Program. The SG repair criteria define limits on SG tube degradation that allow for flaw growth between inspections while still providing assurance that the SG performance criteria will continue to be met. In order to determine if a SG tube that should have been plugged has tube integrity, an evaluation must be completed that demonstrates that the SG performance criteria will continue to be met until the next refueling outage or SG tube inspection. | ||
-UNIT 2 B 3/4 4-3c Amendment No. 181, 211, 213, 243,267, 291,305, 323 RCS Leakage Detection Instrumentation B 3/4.4. | The tube integrity determination is based on the estimated condition of the tube at the time the situation is discovered and the estimated growth of the degradation prior to the next SG tube inspection. If it is determined that tube integrity is not being maintained until the next refueling outage or SG inspection, Action (a) requires unit shutdown and Action (b) requires the affected tube(s) be plugged. | ||
An evaluation of SG tube integrity of the affected tube(s) must | An allowed time of 7 days is sufficient to complete the evaluation while minimizing the risk of plant operation with a SG tube that may not have tube integrity. | ||
The | If the evaluation determines that the affected tube(s) have tube integrity, Action (a) allows plant operation to continue until the next refueling outage or SG inspection provided the inspection interval continues to be supported by an operational assessment that reflects the affected tubes. | ||
The tube integrity determination is based on the estimated condition of | However, the affected tube(s) must be plugged prior to startup following the next refueling outage or SG inspection. This allowed time is acceptable since operation until the next inspection is supported by the operational assessment. | ||
If it is determined | October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3d Amendment No. 181, 211, 213, 243, 267, 291,305 | ||
If the evaluation determines that the affected tube(s) have tube integrity, Action (a) allows plant operation to continue until the next refueling | |||
This allowed time | RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES ACTIONS (continued) | ||
October 5, | If SG tube integrity is not being maintained, the reactor must be brought to HOT STANDBY within 6 hours and COLD SHUTDOWN within the next 30 hours and the affected tube(s) plugged prior to restart (Mode 4). | ||
-UNIT 2 B 3/4 4-3d Amendment No. 181, 211, 213, 243,267, 291,305 RCS Leakage Detection Instrumentation B 3/4.4. | The action times are reasonable, based on operating experience, to reach the desired plant condition from full power in an orderly manner and without challenging plant systems. | ||
If SG tube integrity is not being maintained, the reactor must be brought | SURVEILLANCE SR 4.4.5.0 REQUIREMENTS During shutdown periods the SGs are inspected as required by this SR and the Steam Generator Program. NEI 97-06, Steam Generator Program Guidelines (Ref. 1), and its referenced EPRI Guidelines, establish the content of the Steam Generator Program. Use of the Steam Generator Program ensures that the inspection is appropriate and consistent with accepted industry practices. | ||
NEI 97-06, Steam Generator | During SG inspections a condition monitoring assessment of the SG tubes is performed. The condition monitoring assessment determines the "as found" condition of the SG tubes. The purpose of the condition monitoring assessment is to ensure that the SG performance criteria have been met for the previous operating period. | ||
Use of the Steam Generator Program ensures that the inspection is appropriate and consistent | The Steam Generator Program determines the scope of the inspection and ihe methods used to determine whether the tubes contain flaws satisfying the tube repair criteria. Inspection scope (i.e., which tubes or areas of tubing within the SG are to be inspected) is a function of existing and potential degradation locations. The Steam Generator Program also specifies the inspection methods to be used to find potential degradation. | ||
During SG inspections a condition monitoring assessment of the SG | |||
The condition monitoring assessment determines the " | |||
Inspection scope (i.e., which tubes or areas | |||
The Steam Generator Program | |||
Inspection methods are a function of degradation morphology, nondestructive examination (NDE) technique capabilities, and inspection locations. | Inspection methods are a function of degradation morphology, nondestructive examination (NDE) technique capabilities, and inspection locations. | ||
October 5, | October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3e Amendment No. 181, 211, 213, 243, 267, 291,305, 323 | ||
-UNIT 2 B 3/4 4-3e Amendment No. 181, 211, 213, 243,267, 291,305, 323 RCS Leakage Detection Instrumentation B 3/4.4. | |||
The Steam Generator Program defines the frequency of SR 4.4.5.0. | RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES SURVEILLANCE REQUIREMENTS (continued) | ||
The Steam Generator Program defines the frequency of SR 4.4.5.0. The frequency is determined by the operational assessment and other limits in the SG examination guidelines (Ref. 6). The Steam Generator Program uses information on existing degradations and growth rates to determine an inspection frequency that provides reasonable assurance that the tubing will meet the SG performance criteria at the next scheduled inspection. In addition, Specification 6.8.4.k contains prescriptive requirements concerning inspection intervals to provide added assurance that the SG performance criteria will be met between scheduled inspections. | |||
In addition, Specification 6.8.4.k contains prescriptive requirements concerning inspection intervals to provide added assurance that the SG performance criteria will be met between scheduled inspections. | SR 4.4.5.1 During an SG inspection, any inspected tube that satisfies the Steam Generator Program repair criteria is removed from service by plugging. | ||
SR 4.4.5. | The tube repair criteria delineated in Specification 6.8.4.k are intended to ensure that tubes accepted for continued service satisfy the SG performance criteria with allowance for error in the flaw size measurement and for future flaw growth. In addition, the tube repair criteria, in conjunction with other elements of the Steam Generator Program, ensure that the SG performance criteria will continue to be met until the next inspection of the subject tube(s). Reference 1 provides guidance for performing operational assessments to verify that the tubes remaining in service will continue to meet the SG performance criteria. | ||
The tube repair criteria delineated in Specification 6.8.4.k are intended | The frequency of this surveillance ensures that the surveillance has been completed and all tubes meeting the repair criteria are plugged prior to subjecting the SG tubes to significant primary to secondary pressure differential (i.e., prior to HOT SHUTDOWN following a SG tube inspection). | ||
October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3f Amendment No. 181, 211, 213, 243, 267, 291,305 | |||
Reference 1 provides guidance | |||
The frequency of this surveillance ensures that the surveillance has | RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES REFERENCES | ||
October 5, | : 1. | ||
-UNIT 2 B 3/4 4-3f Amendment No. 181, 211, 213, 243,267, 291,305 RCS Leakage Detection Instrumentation B 3/4.4. | NEI 97-06, "Steam Generator Program Guidelines." | ||
: 1. NEI 97-06, "Steam Generator Program Guidelines." | : 2. | ||
: 2. 10 CFR 50 Appendix A, GDC 19.3. 10CFR100. | 10 CFR 50 Appendix A, GDC 19. | ||
: 4. ASME Boiler and Pressure Vessel Code, Section III, Subsection NB.5. Draft Regulatory Guide 1.121, "Basis for Plugging Degraded | : 3. | ||
SEQUOYAH | 10CFR100. | ||
-UNIT | : 4. | ||
To a lesser extent, other accidents or transients also | ASME Boiler and Pressure Vessel Code, Section III, Subsection NB. | ||
The leakage contaminates | : 5. | ||
Operator action is taken to isolate the affected steam generator within this time period. The 0.4 gpm operational primary to secondary | Draft Regulatory Guide 1.121, "Basis for Plugging Degraded Steam Generator Tubes," August 1976. | ||
The SLB is more limiting for site radiation releases. | : 6. | ||
The safety analysis for | EPRI, "Pressurized Water Reactor Steam Generator Examination Guidelines." | ||
The dose consequences resulting from the SLB accident are | SEQUOYAH - UNIT 2 B 3/4 4-3g October 5, 2012 Amendment No. 181, 211, 213, 243, 267, 291,305, 323 | ||
The expected leak rate following a steam | |||
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES Primary to secondary leakage is a factor in the dose releases outside containment resulting from a steam generator tube rupture or a steam line break (SLB) accident. To a lesser extent, other accidents or transients also involve secondary steam release to the atmosphere. The leakage contaminates the secondary fluid. | |||
The FSAR (Ref. 3) analysis for steam generator tube rupture (SGTR) assumes the contaminated secondary fluid is released via safety valves for up to 30 minutes. Operator action is taken to isolate the affected steam generator within this time period. The 0.4 gpm operational primary to secondary leakage safety analysis assumption is relatively inconsequential. | |||
The SLB is more limiting for site radiation releases. The safety analysis for the SLB accident assumes a 3.7 gpm primary to secondary leakage through the affected generator and 0.3 gpm through the non-affected generators as an initial condition. The dose consequences resulting from the SLB accident are well within the limits defined in 10 CFR 100 or the staff approved licensing basis (i.e., | |||
a small fraction of these limits). The expected leak rate following a steam line rupture is limited to below 3.7 gpm at atmospheric conditions and 70OF in the faulted loop, which will limit the calculated offsite doses to within 10 percent of the 10 CFR 100 guidelines. | |||
The RCS operational leakage satisfies Criterion 2 of the NRC Policy Statement. | The RCS operational leakage satisfies Criterion 2 of the NRC Policy Statement. | ||
LCO RCS operational leakage shall be limited to: | |||
: a. | |||
PRESSURE BOUNDARY LEAKAGE No PRESSURE BOUNDARY LEAKAGE is allowed, being indicative of material deterioration. Leakage of this type is unacceptable as the leak itself could cause further deterioration, resulting in higher leakage. | |||
Violation of this LCO could result in continued degradation of the RCPB. | |||
Leakage past seals and gaskets is not PRESSURE BOUNDARY LEAKAGE. | |||
: b. | |||
UNIDENTIFIED LEAKAGE One gpm of UNIDENTIFIED LEAKAGE is allowed as a reasonable minimum detectable amount that the containment air monitoring and containment pocket October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-4f Amendment No. 211, 213, 227, 250, 305, 323 | |||
ECCS - Shutdown B 3/4.5.3 B 3/4.5 EMERGENCY CORE COOLING SYSTEM (ECCS) | |||
B 3/4.5.3 ECCS - Shutdown BASES BACKGROUND The Background section for Bases 3.5.2, "ECCS - Operating," is applicable to these Bases, | |||
==References:== | ==References:== | ||
ASTM Standards D4057-1988, "Practice for manual sampling of petroleum and petroleum Products." | |||
D975-1990, "Standard Specifications for Diesel Fuel oils." | |||
D4176-1986, "Free Water and Particulate Contamination in Distillate Fuels." | |||
D1552-1990, "Standard Test Method for Sulfur in Petroleum Products (High Temperature Method)." | |||
December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-8 Amendment No. 123, 241, 252 | |||
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued) | |||
D2622-1987, "Standard Test Method for Sulfur in Petroleum Products (X-Ray Spectrographic Method)." | D2622-1987, "Standard Test Method for Sulfur in Petroleum Products (X-Ray Spectrographic Method)." | ||
D2276-1994, "Standard Test Method for Particulate Containment in Aviation Turbine Fuels."D1298-1985, "Standard Test Method for Density, Specific | D2276-1994, "Standard Test Method for Particulate Containment in Aviation Turbine Fuels." | ||
D1298-1985, "Standard Test Method for Density, Specific Gravity, or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method." | |||
-UNIT | 3/4.8.3 ELECTRICAL EQUIPMENT PROTECTIVE DEVICES This specification is deleted. | ||
SEQUOYAH - UNIT 2 December 21, 2012 Amendment No. 123, 241, 252 B 3/4 8-9}} | |||
Latest revision as of 07:03, 11 January 2025
| ML13193A039 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 07/05/2013 |
| From: | James Shea Tennessee Valley Authority |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML13193A039 (114) | |
Text
Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 July 5, 2013 10 CFR 50.4 10 CFR 50.71(e)
ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Sequoyah Nuclear Plant, Units 1 and 2 Facility Operating License Nos. DPR-77 and DPR-79 NRC Docket Nos. 50-327 and 50-328
Subject:
Revisions to the Sequoyah Nuclear Plant Technical Requirements Manual and Units I and 2 Technical Specification Bases
References:
- 1. NRC Letter to TVA, "Issuance of Exemption to 10 CFR 71(e)(4) for the Sequoyah Nuclear Plant, Units 1 and 2 (TAC Nos. MA0646 and MA0647)," dated March 9, 1998
- 2. TVA Letter to NRC, "Revisions to the Sequoyah Nuclear Plant Technical Requirements Manual and Units 1 and 2, Technical Specification Bases,"
dated December 16, 2011 Pursuant to 10 CFR 50.71(e) and the Reference 1 letter, updates to the Sequoyah Nuclear Plant (SQN) Updated Final Safety Analysis Report (UFSAR) for both Units 1 and 2 are to be submitted within six months after each refueling outage, not to exceed 24 months between successive revisions. The SQN Technical Requirements Manual (TRM) is incorporated by reference into the SQN UFSAR. In addition, SQN Technical Specification 6.8.4.j, "Technical Specification (TS) Bases Control Program," requires changes to the SQN TS Bases to be submitted in accordance with 10 CFR 50.71(e). This letter provides the required updates to the SQN TRM and TS Bases since the previous update submitted via the Reference 2 Letter. The last Unit 2 refueling outage ended on January 6, 2013, and as such, these updates are required by July 5, 2013. The enclosure to this letter provides a description of the TRM and TS Bases revisions with attachments of the updated pages, respectively.
Printed on recycled paper
U.S. Nuclear Regulatory Commission Page 2 July 5, 2013 There are no commitments contained in this letter. If you have any questions, please contact Michael McBrearty at (423) 843-7170.
I certify that I am duly authorized by TVA, and that, to the best of my knowledge and belief, the information contained herein accurately presents changes made since the previous submittal, necessary to reflect information and analyses submitted to the Commission or prepared pursuant to Commission requirements.
Respectf lly, eesident, Nuclear Licensing
Enclosure:
Description of Revisions for the Sequoyah Nuclear Plant (SQN), Technical Requirements Manual and SQN, Units 1 and 2 Technical Specification Bases cc (Enclosure):
NRC Regional Administrator-Region II NRC Senior Resident Inspector - Sequoyah Nuclear Plant
ENCLOSURE DESCRIPTION OF REVISIONS FOR THE SEQUOYAH NUCLEAR PLANT (SQN),
TECHNICAL REQUIREMENTS MANUAL AND SQN, UNITS I AND 2 TECHNICAL SPECIFICATION BASES Technical Requirements Manual Revisions Technical Requirements Manual (TRM) Revision 47 was approved on September 27, 2012, and implemented on October 5, 2012. A change was made to TR 3.1.2.2, "Flow Paths - Operating,"
and TR 3.1.2.4, "Charging Pumps - Operating," to allow an operational provision similar to the technical specifications (TSs) allowance for temporarily disabling one half of the boron injection function of the Chemical and Volume Control System (i.e., one charging pump and associated flow path) to support transition between Modes 3 and 4. Provisions are provided in the TSs that allow the Emergency Core Cooling System (ECCS) pumps to be made incapable of injecting, in Mode 3, for a limited amount of time or system conditions to support Low Temperature Over Pressure Protection (LTOP) System operations. This provision prevents TS non-compliance when entering into and out of Mode 3 when two charging pumps are required to be operable.
This change aligns the TRM to be consistent with the TSs for support of LTOP System operations.
On May 15, 2007, TRM Revision 37 was reported to NRC. TRM Revision 37 was in support of SQN TS Amendment Nos. 305 for Unit 1 and 295 for Unit 2. A typographical error has been identified involving symbol characters with the issued page for TR 3.3.3.2, "Moveble Incore Detectors." The corrected page is submitted herein without change to the revision bar.
Technical Specification Bases Revisions Revision 38 to the SQN, Units 1 and 2 Technical Specification (TS) Bases was approved on March 24, 2012, and implemented on March 26, 2012. The revision was in light of TS Change 07-05, "Emergency Core Cooling Systems (ECCS)" for SQN, Units 1 and 2,and associated with TS Amendment Nos. 326 and 319 approved on January 28, 2010. TS Bases Section 3.5.3, "ECCS - Shutdown," was revised to support primary and secondary residual heat removal check valve testing during Mode 4 operation. The changes differentiated TS Bases Section 3.5.2, "ECCS - Operating," Mode 1 through 3 safety analysis conditions from Mode 4 conditions, defines the necessary ECCS operation and flow paths, and added a reference.
Revision 39 to the SQN Unit 1 TS Bases was approved on October 5, 2012, and implemented on October 25, 2012. This revision was in concert with TS Amendment No. 330. Limiting Condition for Operation (LCO), 3.7.5 "Ultimate Heat Sink," was amended to support maintenance activities during the Unit 2 refueling outage No. 18. The TS Bases were changed to identify additional LCO restrictions with respect to maximum average Essential Raw Cooling Water (ERCW) system supply header water temperature during large heavy load lifts performed to support the refueling outage.
Revision 40 to the Unit 1 and Revision 39 to the Unit 2 TS Bases were approved on October 10, 2012. Unit 2 was implemented on November 28, 2012 during its refueling outage. Unit 1 will implement this revision during its next refueling outage in the Fall of 2013; therefore is not provided in this update. These TS Bases revisions are associated with TS Amendment Nos.
331 and 324 for approved TS Change 11-07, "Application to Modify Technical Specifications for Use of AREVA Advanced W17 HTP Fuel." This change affected TS Bases Section 2.1, "Safety E1-1
Limits," and Section 3/4.2.5, "DNB Parameters," as it provided clarifications associated with the evaluation methodology for the new fuel design.
Revision 40 to the Unit 2 TS Bases was approved on October 5, 2012, and implemented on November 2, 2012. This TS Bases revision to Section 3/4.4.5, "Reactor Coolant System," and Section 3/4.4.6.2, "Operation Leakage," was associated with replacement of the Unit 2 steam generators. The revision is associated with TS Amendment No. 323, in which previously approved steam generator inspections, specific repair criteria and reporting requirements had been modified or removed.
Revision 41 to the SQN, Units 1 and 2 Bases was approved on December 21, 2012, and implemented on December 27, 2012. This revision incorporated changes to the Bases for Specification 3.8.1, "A. C. Sources," to describe a new surveillance requirement approved under TS Amendment Nos. 332 and 325 for Units 1 and 2, respectively. Other changes to the TS Bases section include example descriptions of offsite power configurations that would meet the requirements of TS LCO 3.8.1.1.a.
Revision 42 to the SQN, Units 1 and 2 Bases was approved on March 5, 2013, and implemented on March 25, 2013. TS Bases Section 3/4.3.3.7, "Accident Monitoring Instrumentation," was revised. Statements describing accident monitoring instrumentation, specifically the SQN hydrogen monitoring channels were deleted. This change was associated with TS Amendment Nos. 296 and 286 for Units 1 and 2, respectively, which eliminated the requirements for hydrogen recombiners and hydrogen monitoring.
Also, enclosed is a typographical correction to TS Bases Table B 3/4.4-1, SQN Unit 1 Reactor Vessel Toughness Data with no indication of a revision bar. This change corrects the value of nickel in the weld material of the reactor vessel.
Attachments:
- 1.
Sequoyah Nuclear Plant, Technical Requirements Manual - Changed Pages
- 2.
Sequoyah Nuclear Plant, Unit 1, Technical Specification Bases - Changed Pages
- 3.
Sequoyah Nuclear Plant, Unit 2, Technical Specification Bases - Changed Pages E1-2
,1 ATTACHMENT I SEQUOYAH NUCLEAR PLANT TECHNICAL REQUIREMENTS MANUAL CHANGED PAGES TRM Affected Pages EPL-1 EPL-2 EPL-5 EPL-8 Index Page III 3/4 1-3 through 3/4 1-13 3/4 3-2 B 3/4 1-2 B 3/4 1-3
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL REQUIREMENTS MANUAL EFFECTIVE PAGE LISTING Page Revision Index Page I 09/28/03 Index Page II 02/02/98 Index Page III 09/27/12 Index Page IV 01/20/06 Index Page V 01/20/06 Index Page VI 01/20/06 Index Page VII 02/02/98 Index Page VIII 02/02/98 1-1 02/02/98 1-2 05/18/09 1-3 09/28/03 1-4 07/19/02 1-5 07/25/02 1-6 02/02/98 1-7 02/02/98 1-8 02/02/98 3/4 0-1 05/27/05 3/4 0-2 05/27/05 3/4 0-3 07/25/06 3/4 0-4 07/25/06 3/4 1-1 01/04/01 3/4 1-2 10/12/05 EPL-1 September 27, 2012
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL REQUIREMENTS MANUAL EFFECTIVE PAGE LISTING Paqe Revision 3/4 1-3 09/27/12 3/4 1-4 09/27/12 3/4 1-5 09/27/12 3/4 1-6 09/27/12 3/4 1-7 09/27/12 3/4 1-9 09/27/12 3/4 1-10 09/27/12 3/4 1-11 09/27/12 3/4 1-12 09/27/12 3/4 1-13 09/27/12 3/4 3-1 01/20/06 3/4 3-2 01/20/06 3/4 3-3 01/20/06 3/4 3-4 01/20/06 3/4 3-5 01/20/06 3/4 3-6 10/17/06 3/4 3-7 04/26/06 3/4 3-8 04/26/06 3/4 3-9 01/20/06 3/4 3-10 01/20/06 3/44-1 01/20/06 3/4 4-2 01/20/06 3/4 4 01/20/06 EPL-2 September 27, 2012
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL REQUIREMENTS MANUAL EFFECTIVE PAGE LISTING Page Revision B 3/4 1-1 01/04/01 B 3/4 1-2 Through B 3/4 1-3 09/27/12 B 3/4 1-4 Through B 3/4 1-6 01/04/01 B 3/4 3-1 01/20/06 B 3/4 3-2 01/20/06 B 3/4 3-3 01/20/06 B 3/4 3-4 01/20/06 B 3/4 3-5 01/20/06 B 3/4 3-6 01/20/06 B 3/4 3-7 01/20/06 B 3/4 3-8 01/20/06 B 3/4 3-9 01/20/06 B 3/4 3-10 01/20/06 B 3/4 3-11 01/20/06 B 3/4 3-12 01/20/06 B 3/4 3-13 01/20/06 B 3/4 3-14 01/20/06 B 3/4 4-1 01/20/06 B 3/4 4-2 01/20/06 B 3/4 4-3 01/20/06 EPL-5 September 27, 2012
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL REQUIREMENTS MANUAL REVISION LISTING Revision Date Initial Issue, Revision 0 02/02/98 Revision 1 10/01/98 Revision 2 02/12/99 Revision 3 03/18/99 Revision 4 09/14/99 Revision 5 10/24/99 Revision 6 09/29/99 Revision 7 12/09/99 Revision 8 03/23/00 Revision 9 06/02/00 Revision 10 06/13/00 Revision 11 06/15/00 Revision 12 11/09/00 Revision 13 01/04/01 Revision 14 04/05/01 Revision 15 07/11/01 Revision 16 04/05/02 Revision 17 03/27/02 Revision 18 07/19/02 Revision 19 07/25/02 Revision 20 10/11/02 Revision 21 03/06/03 Revision 22 08/11/03 Revision 23 09/14/03 Revision 24 09/28/03 Revision 25 10/31/03 Revision 26 09/26/03 Revision 27 09/26/03 Revision 28 05/15/04 Revision 29 10/13/04 Revision 30 10/13/04 Revision 31 04/22/05 Revision 32 05/27/05 Revision 33 06/20/05 Revision 34 06/24/05 Revision 35 10/12/05 Revision 36 10/19/05 Revision 37 01/20/06 Revision 38 03/08/06 Revision 39 03/17/06 Revision 40 04/26/06 Revision 41 07/25/06 Revision 42 09/15/06 Revision 43 10/17/06 Revision 44 11/14/06 Revision 45 05/18/09 Revision 46 11/29110 Revision 47 09/27/12 EPL-8 September 27, 2012
INDEX TECHNICAL REQUIREMENTS SECTION PAGE T R 3/4.0 A P P LIC A B ILIT Y.................................................................................................................
3/4 0-1 TR 3/4.1 REACTIVITY CONTROL SYSTEMS T R 3/4.1.1 (N o current requirem ents)..................................................................................................
3/4 1-1 TR 3/4.1.2 BORATION SYSTEMS TR 3/4.1.2.1 FLOW PATHS - SHUTDOW N...........................................................................
3/4 1-2 TR 3/4.1.2.2 FLOW PATHS - O PERATING...........................................................................
3/4 1-3 TR 3/4.1.2.3 CHARGING PUMP - SHUTDOWN....................................................................
3/4 1-5 TR 3/4.1.2.4 CHARGING PUMPS - OPERATING.................................................................
3/4 1-6 TR 3/4.1.2.5 BORATED WATER SOURCES - SHUTDOWN................................................
3/4 1-7 TR 3/4.1.2.6 BORATED WATER SOURCES - OPERATING................................................
3/4 1-9 TR 3/4.1.3.1 Through TR 3/4.1.3.2 (No current requirements).........................................................
3/4 1-12 TR 3/4.1.3.3 POSITION INDICATION SYSTEM - SHUTDOWN......................................................
3/4 1-13 TR 3/4.2 POWER DISTRIBUTION LIMITS No current requirements TR 3/4.3 INSTRUMENTATION TR 3/4.3.1 Through TR 3/4.3.3.1 (No current requirements)..............................................................
3/4 3-1 TR 3/4.3.3 MONITORING INSTRUMENTATION TR 3/4.3.3.2 MOVABLE INCORE DETECTORS...................................................................
3/4 3-2 TR 3/4.3.3.3 SEISMIC INSTRUMENTATION........................................................................
3/4 3-3 TR 3/4.3.3.4 METEOROLOGICAL INSTRUMENTATION.....................................................
3/4 3-6 TR 3/4.3.3.5 Through TR 3/4.3.3.14 (No current requirements)...........................................
3/4 3-9 TR 3/4.3.3.15 PLANT CALORIMETRIC MEASURMENT....................................................
3/4 3-10 TR 3/4.4 REACTOR COOLANT SYSTEM TR 3/4.4.1 Through TR 3/4 4.6 (No current requirements).................................................................
3/4 4-1 T R 3/4 4.7 C H E M IS T R Y......................................................................................................................
3/4 4-2 TR 3/4.4.8 Through TR 3/4 4.9.1 (No current requirements)..............................................................
3/4 4-5 TR 3/4 4.9.2 PRESSURIZER TEMPERATURE LIMITS.....................................................................
3/4 4-6 T R 3/4.4.10 (N o current requirem ents)................................................................................................
3/4 4-7 TR 3/4 4.11 REACTOR COOLANT SYSTEM HEAD VENTS.............................................................
3/4 4-8 TR 3/4.5 EMERGENCY CORE COOLING SYSTEMS (ECCS)
No current requirements SEQUOYAH - UNITS 1 AND 2 III September 27, 2012 TECHNICAL REQUIREMENTS Revision Nos. 1, 3-5, 8-13, 16, 17, 20, 23, 29,30,31,37,47
REACTIVITY CONTROL SYSTEMS FLOW PATHS - OPERATING LIMITING CONDITION FOR OPERATION TR 3.1.2.2 At least two of the following three boron injection flow paths shall be OPERABLE:
- a.
The flow path from the boric acid tanks via a boric acid transfer pump and a charging pump to the Reactor Coolant System.
- b.
Two flow paths from the refueling water storage tank via charging pumps to the Reactor Coolant System.
NNOT----------------
In MODE 3, one charging pump may be made incapable of injecting to support transition into or from the APPLICABILITY of Technical Specification LCO 3.4.12, "Low Temperature Overpressure Protection (LTOP) System," for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or until the temperature of all RCS cold legs exceeds LTOP arming temperature (350°F) specified in the Pressure and Temperature Limits Report (PTLR) plus 250F, whichever comes first.
APPLICABILITY: MODES 1, 2, and 3.
ACTION:
With only one of the above required boron injection flow paths to the Reactor Coolant System OPERABLE, restore at least two boron injection flow paths to the Reactor Coolant System to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY and borated to a SHUTDOWN MARGIN equivalent to at least 1% delta k/k at 200OF within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore at least two flow paths to OPERABLE status within the next 7 days or be in HOT SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
SURVEILLANCE REQUIREMENTS TR 4.1.2.2 At least two of the above required flow paths shall be demonstrated OPERABLE:
- a.
At least once per 7 days by verifying that the temperature of the areas containing flow path components from the boric acid tanks to the blending tee is greater than or equal to 630F when it is a required water source.
- b.
Whenever the area temperature(s) is(are) less than 63 0F and the boric acid tank is a required water source, the solution temperature in the flow path components from the boric acid tank must be measured to be greater than or equal to 630F within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter until the area temperature(s) has(have) returned to greater than or equal to 630F.
SEQUOYAH - UNITS 1 AND 2 3/4 1-3 September 27, 2012 TECHNICAL REQUIREMENTS Revision Nos. 13, 46, 47
REACTIVITY CONTROL SYSTEMS FLOW PATHS - OPERATING SURVEILLANCE REQUIREMENTS (continued)
- c.
At least once per 31 days by verifying that each valve (manual, power operated or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.
- d.
At least once per 18 months during shutdown by verifying that each automatic valve in the flow path actuates to its correct position on a safety injection test signal.
- e.
At least once per 18 months by verifying that the flow path required by TR 3.1.2.2a delivers at least 35 gpm to the Reactor Coolant System.
SEQUOYAH - UNITS 1 AND 2 TECHNICAL REQUIREMENTS 3/4 1-4 September 27, 2012 Revision Nos. 13, 46
REACTIVITY CONTROL SYSTEMS CHARGING PUMP - SHUTDOWN LIMITING CONDITION FOR OPERATION TR 3.1.2.3 One charging pump in the boron injection flow path required by TR 3.1.2.1 shall be OPERABLE and capable of being powered from an OPERABLE shutdown board.
APPLICABILITY: MODES 4, 5 and 6.
ACTION:
MODE 4 - With no charging pump OPERABLE, suspend operations that would cause introduction of coolant into the RCS with boron concentration less than required to meet SDM of Technical Specification LCO 3.1.1.1 and restore one changing pump as soon as possible.
MODE 5 - With no charging pump OPERABLE, suspend operations that would cause introduction of coolant into the RCS with boron concentration less than required to meet SDM of Technical Specification LCO 3.1.1.2.
MODE 6 - With no charging pump OPERABLE, suspend all operations involving CORE ALTERATIONS and suspend operations that would cause introduction of coolant into the RCS with boron concentration less than required to meet Technical Specification LCO 3.9.1.
SURVEILLANCE REQUIREMENTS TR 4.1.2.3 The above required charging pump shall be demonstrated OPERABLE by verifying, that on recirculation flow, the pump develops a discharge pressure of greater than or equal to 2400 psig when tested pursuant to TR 4.0.5.
SEQUOYAH - UNITS I AND 2 TECHNICAL REQUIREMENTS 3/4 1-5 September 27, 2012 Revision Nos. 13, 25, 35
REACTIVITY CONTROL SYSTEMS CHARGING PUMPS - OPERATING LIMITING CONDITION FOR OPERATION TR 3.1.2.4 At least two charging pumps shall be OPERABLE.
NOTE In MODE 3, one charging pump may be made incapable of injecting to support transition into or from the APPLICABILITY of Technical Specification LCO 3.4.12, "Low Temperature Overpressure Protection (LTOP) System," for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or until the temperature of all RCS cold legs exceeds LTOP arming temperature (3500 F) specified in the Pressure and Temperature Limits Report (PTLR) plus 25°F, whichever comes first.
APPLICABILITY: MODES 1, 2, and 3.
ACTION:
With only one charging pump OPERABLE, restore at least two charging pumps to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY and borated to a SHUTDOWN MARGIN equivalent to at least 1% delta k/k at 200OF within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore at least two charging pumps to OPERABLE status within the next 7 days or be in HOT SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
SURVEILLANCE REQUIREMENTS TR 4.1.2.4 At least two charging pumps shall be demonstrated OPERABLE by verifying, that on recirculation flow, each pump develops a discharge pressure of greater than or equal to 2400 psig when tested pursuant to TR 4.0.5.
SEQUOYAH - UNITS 1 AND 2 TECHNICAL REQUIREMENTS 3/4 1-6 September 27, 2012 Revision Nos. 13, 47
REACTIVITY CONTROL SYSTEMS BORATED WATER SOURCES - SHUTDOWN LIMITING CONDITION FOR OPERATION TR 3.1.2.5 As a minimum, one of the following borated water sources shall be OPERABLE:
- a.
A boric acid storage system with:
- 1.
A minimum contained borated water volume of 6400 gallons,
- 2.
Between 6120 and 6990 ppm of boron, and
- 3.
A minimum solution temperature of 630F.
- b.
The refueling water storage tank with:
- 1.
A minimum contained borated water volume of 55,000 gallons,
- 2.
A minimum boron concentration of 2500 ppm, and
- 3.
A minimum solution temperature of 600F.
APPLICABILITY: MODES 4, 5 and 6.
ACTION:
MODE 4 - With no borated water source OPERABLE, suspend operations that would cause introduction of coolant into the RCS with boron concentration less than required to meet SDM of Technical Specification LCO 3.1.1.1.
MODE 5 - With no borated water source OPERABLE, suspend operations that would, cause introduction of coolant into the RCS with boron concentration less than required to meet SDM of Technical Specification LCO 3.1.1.2.
MODE 6 - With no borated water source OPERABLE, suspend all operations involving CORE ALTERATIONS and suspend operations that would cause introduction of coolant into the RCS with boron concentration less than required to meet Technical Specification LCO 3.9.1.
SURVEILLANCE REQUIREMENTS TR 4.1.2.5 The above required borated water source shall be demonstrated OPERABLE:
- a.
For the boric acid storage system, when it is the source of borated water by:
- 1.
Verifying the boron concentration at least once per 7 days,
- 2.
Verifying the borated water volume at least once per 7 days, and SEQUOYAH - UNITS 1 AND 2 TECHNICAL REQUIREMENTS 3/4 1-7 September 27, 2012 Revision Nos. 13, 25, 35, 36
REACTIVITY CONTROL SYSTEMS SURVEILLANCE REQUIREMENTS (Continued)
- 3.
Verifying the boric acid storage tank solution temperature is greater than or equal to 630F at least once per 7 days by verifying the area temperature to be greater than or equal to 630F, or
- 4.
When the boric acid tank area temperature is less than 630 F and the boric acid storage system being used as the source of borated water, within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter, verify the boric acid tank solution temperature to be greater than or equal to 630F until the boric acid tank area temperature has returned to greater than or equal to 630 F.
- b.
For the refueling water storage tank by:
- 1.
Verifying the boron concentration at least once per 7 days,
- 2.
Verifying the borated water volume at least once per 7 days, and
- 3.
Verifying the solution temperature at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> while in Mode 4 or while in Modes 5 or 6 when it is the source of borated water.
SEQUOYAH - UNITS 1 AND 2 TECHNICAL REQUIREMENTS 3/4 1-8 September 27, 2012 Revision Nos. 13
REACTIVITY CONTROL SYSTEMS BORATED WATER SOURCES - OPERATING LIMITING CONDITION FOR OPERATION TR 3,1.2.6 As a minimum, the following borated water source(s) shall be OPERABLE as required by TR 3.1.2.2:
- a.
A boric acid storage system with:
- 1.
A contained volume of borated water in accordance with Figure 3.1.2.6,
- 2.
A boron concentration in accordance with Figure 3.1.2.6, and
- 3.
A minimum solution temperature of 630F.
- b.
The refueling water storage tank with:
- 1.
A contained borated water volume of between 370,000 and 375,000 gallons,
- 2.
Between 2500 and 2700 ppm of boron,
- 3.
A minimum solution temperature of 600 F, and
- 4.
A maximum solution temperature of 1050F.
APPLICABILITY: MODES 1, 2, and 3.
ACTION:
- a.
With the boric acid storage system inoperable and being used as one of the above required borated water sources, restore the storage system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and borated to a SHUTDOWN MARGIN equivalent to at least 1% delta k/k at 200°F; restore the boric acid storage system to OPERABLE status within the next 7 days or be in HOT SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
- b.
With the refueling water storage tank inoperable, restore the tank to OPERABLE status within one hour or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
SEQUOYAH - UNITS 1 AND 2 3/4 1-9 September 27, 2012 TECHNICAL REQUIREMENTS Revision Nos. 13
REACTIVITY CONTROL SYSTEMS SURVEILLANCE REQUIREMENTS TR 4.1.2.6 Each borated water source shall be demonstrated OPERABLE:
- a.
For the boric acid storage system, when it is the source of borated water by:
- 1.
Verifying the boron concentration at least once per 7 days,
- 2.
Verifying the borated water volume at least once per 7 days, and
- 3.
Verifying the boric acid storage tank solution temperature is greater than or equal to 630 F at least once per 7 days by verifying the area temperature to be greater than or equal to 630F, or
- 4.
Whenever the boric acid tank area temperature is less than 630F and the boric acid storage system being used as the source of borated water, within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter, verify the boric acid tank solution temperature to be greater than or equal to 630F until the boric acid tank area temperature has returned to greater than or equal to 630F.
- b.
For the refueling water storage tank by:
- 1.
Verifying the boron concentration at least once per 7 days,
- 2.
Verifying the borated water volume at least once per 7 days, and
- 3.
Verifying the solution temperature at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
SEQUOYAH - UNITS 1 AND 2 TECHNICAL REQUIREMENTS 3/4 1-10 September 27, 2012 Revision Nos; 13, 33
TRM FIGURE 3.1.2.6 (Units 1 & 2)
BORIC ACID TANK LIMITS BASED ON RWST BORON CONCENTRATION 11000 10500 10000 z0
-j
-j 0
w
..J 0
z I-l C..
0 0
w l-0 z
[REGION OF ACCEPTABLE OPERATION RWST 2500 ppmnB RWST = 2550 ppm B RWST = 2600 ppm B RWST 2650ppmB RWST 2700 ppmB 6120 ppm (Minimum) 6990 ppm (Maximum) 9500 9000 8500 7500-.
[REGION OF UNACCEPTABLE OPERATION 7000 -
I I I I I I I I i I I I I Indicated values include 1140 gal unusable volume and 800 gal for instrument error.
I I I I
I I I I I 650 t*
U
~fl*
6000 6100 6200 6300 6400 6500 6600 6700 6800 6900 7000 7100 BORIC ACID TANK CONCENTRATION - PPM BORON RWST Concentration
--4--2500 PPM
--4--2550 PPM
--,-2700 PPM SEQUOYAH - UNITS 1 AND 2
- TECHNICAL REQUIREMENTS 3/4E1-11 September 27, 2012 Revision Nos. 13, 26, 27
TR 3/4.1 REACTIVITY CONTROL SYSTEMS TR 3/4 1.3.1 No current requirements TR 3/4 1.3.2 No current reauirements SEQUOYAH - UNITS 1 AND 2 TECHNICAL REQUIREMENTS 3/4 1-12 September 27, 2012 Revision Nos. 13
REACTIVITY CONTROL SYSTEMS POSITION INDICATION SYSTEM - SHUTDOWN LIMITING CONDITION FOR OPERATION TR 3.1.3.3 The group demand position indicator shall be OPERABLE and capable of determining within
+/- 2 steps, the demand position for each shutdown or control rod not fully inserted.
APPLICABILITY: MODES 3*, 4* and 5*.
ACTION:
With less than the above required group demand position indicator(s) OPERABLE, immediately open the reactor trip system breakers.
SURVEILLANCE REQUIREMENTS TR 4.1.3.3 Each of the above required group demand position indicator(s) shall be determined to be OPERABLE by movement of the associated control rod at least 10 steps in any one direction at least once per 31 days.
- With the reactor trip system breakers in the closed position.
SEQUOYAH - UNITS 1 AND 2 TECHNICAL REQUIREMENTS 3/4 1-13 September 27, 2012 Revision Nos. 13
INSTRUMENTATION MOVABLE INCORE DETECTORS LIMITING CONDITION FOR OPERATION TR 3.3.3.2 The movable incore detection system shall be OPERABLE with:
- a.
At least 75% of the detector thimbles,
- b.
A minimum of 2 detector thimbles per core quadrant, and
- c.
Sufficient movable detectors, drive, and readout equipment to map these thimbles.
APPLICABILITY: When the movable incore detection system is used for:
- a.
Recalibration of the excore neutron flux detection system,
- b.
Monitoring the QUADRANT POWER TILT RATIO, or
- c.
Measurement of FN and FQ(Z).
FAH an Q()
ACTION:
With the movable incore detection system inoperable, do not use the system for the above applicable monitoring or calibration functions. The provisions of Specification TR 3.0.3 are not applicable.
SURVEILLANCE REQUIREMENTS TR 4.3.3.2 The movable incore detection system shall be demonstrated OPERABLE by normalizing each detector output when required for:
- a.
Recalibration of the excore neutron flux detection system, or
- b.
Monitoring the QUADRANT POWER TILT RATIO, or
- c.
Measurement of FN and FQ(Z).
FAH an Q()
SEQUOYAH - UNITS 1 AND 2 3/4 3-2 January 20, 2006 TECHNICAL REQUIREMENTS Revision Nos. 37
REACTIVITY CONTROL SYSTEMS BASES TRB 3/4.1.2 BORATION SYSTEMS The boron injection system ensures that negative reactivity control is available during each mode of facility operation. The components required to perform this function include 1) borated water sources,
- 2) charging pumps, 3) separate flow paths, 4) boric acid transfer pumps, and 5) an emergency power supply from OPERABLE diesel generators.
With the RCS average temperature above 350 0F, a minimum of two boron injection flow paths are required to ensure single functional capability in the event an assumed failure renders one of the flow paths inoperable. The boration capability of either flow path is sufficient to provide a SHUTDOWN MARGIN from expected operating conditions of 1.6% delta k/k after xenon decay and cooldown to 2000F.
The maximum expected boration capability requirement occurs at near EOL from full power peak xenon conditions and requires borated water from a boric acid tank in accordance with Figure 3.1.2.6, and additional makeup from either: (1) the common boric acid tank and/or batching, or (2) a minimum of 26,000 gallons of 2500 ppm borated water from the refueling water storage tank. With the refueling water storage tank as the only borated water source, a minimum of 57,000 gallons of 2500 ppm borated water is required.
TR 3.1.2.4 and TR 3.1.2.2 are modified by a Note. Operation in MODE 3 with one charging pump made incapable of injecting, in order to facilitate entry into or exit from the Applicability of Technical Specification LCO 3.4.12, "Low Temperature Overpressure Protection (LTOP) System," is necessary for plants with an LTOP arming temperature at or near the MODE 3 boundary temperature of 3500 F.
Technical Specification LCO 3.4.12 requires that certain pumps be rendered incapable of injecting at and below the LTOP arming temperature. When this temperature is at or near the MODE 3 boundary temperature, time is needed to make a pump incapable of injecting prior to entering the LTOP Applicability, and provide time to restore the inoperable pump to OPERABLE status on exiting the LTOP Applicability.
The boric acid tanks, pumps, valves, and piping contain a boric acid solution concentration of between 3.5% and 4.0% by weight. To ensure that the boric acid remains in solution, the air temperature is monitored in strategic locations. By ensuring the air temperature remains at 630F or above, a 50F margin is provided to ensure the boron will not precipitate out. To provide operational flexibility, if the area temperature should fall below the required value, the solution temperature (as determined by the pipe or tank wall temperature) will be monitored at an increased frequency to compensate for the lack of solution temperature alarm in the main control room.
With the RCS temperature below 3500F, one injection system is acceptable without single failure consideration on the basis of the stable reactivity condition of the reactor and the additional restrictions prohibiting CORE ALTERATIONS and operations involving positive reactivity additions that could result in loss of required SDM (Modes 4 or 5) or boron concentration (Mode 6) in the event the single injection system becomes inoperable. Suspending positive reactivity additions that could result in failure to meet minimum SDM or boron concentration limit is required to assure continued safe operation. Introduction of coolant inventory must be from sources that have a boron concentration greater than or equal to that required in the RCS for minimum SDM or refueling boron concentration. This may result in an overall reduction in RCS boron concentration but provides acceptable margin to maintaining subcritical operation. Introduction of temperature changes including temperature increases when operating with a positive MTC must also be evaluated to ensure they do not result in a loss of required SDM.
SEQUOYAH - UNITS 1 AND 2 B 3/4 1-2 September 27, 2012 TECHNICAL REQUIREMENTS Revision Nos. 13, 25, 35, 36, 47
REACTIVITY CONTROL SYSTEMS BASES The boron capability required below 3500 F, is sufficient to provide a SHUTDOWN MARGIN of 1.6% delta k/k after xenon decay and cooldown from 350OF to 2000, and a SHUTDOWN MARGIN of 1%
delta k/k after xenon decay and cooldown from 200OF to 140 0F. This condition requires either 6400 gallons of 6120 ppm borated water from the boric acid storage tanks or 13,400 gallons of 2500 ppm borated water from the refueling water storage tank.
The contained water volume limits include allowance for water not available because of discharge line location and other physical characteristics. The 6400 gallon limit in the boric acid tank for Modes 4, 5, and 6 is based on 4,431 gallons required for shutdown margin, 1,140 gallons for the unusable volume in the heel of the tank, 800 gallons for instrument error, and an additional 29 gallons due to rounding up.
The 55,000 gallon limit in the refueling water storage tank for modes 4, 5, and 6 is based upon 22,182 gallons that is undetectable due to lower tap location, 19,197 gallons for instrument error, 13,400 gallons required for shutdown margin, and an additional 221 gallons due to rounding up.
The limits on contained water volume and boron concentration of the RWST also ensure a pH value of between 7.5 and 9.5 for the solution recirculated within containment after a LOCA. This pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion on mechanical systems and components.
The OPERABILITY of one boron injection system during REFUELING ensures that this system is available for reactivity control while in MODE 6.
SEQUOYAH - UNITS 1 AND 2 TECHNICAL REQUIREMENTS B 3/4 1-3 September 27, 2012 Revision Nos. 13, 36
ATTACHMENT 2 SEQUOYAH NUCLEAR PLANT, UNIT I TECHNICAL SPECIFICATION BASES CHANGED PAGES TS Bases Affected Pages EPL Page 18 EPL Page 20 EPL Page 21 EPL Page 22 EPL Page 25 EPL Page 26 EPL Page 27 EPL Page 28 EPL Page 29 EPL Page 30 EPL Page 31 EPL Page 32 EPL Page 33 EPL Page 34 Index Page XIV B 3/4 3-3a B 3/4 4-12 B 3/4 5-12 B 3/4 5-13 B 3/4 5-14 B 3/4 5-15 B 3/4 5-16 B 3/4 5-17 B 3/4 5-18 B 3/4 5-19 B 3/4 5-20 B 3/4 7-4a B 3/4 7-4b B 3/4 8-1 B 3/4 8-2 B 3/4 8-3 B 3/4 8-4 B 3/4 8-5 B 3/4 8-6 B 3/4 8-7 B 3/4 8-8 B 3/4 8-9
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paqe Revision B3/4 3-3 12/28/05 B3/4 3-3a 03/05/13 B3/4 3-4 08/12/97 B3/4 3-5 through B3/4 3-9 09/14/06 B3/4 4-1 03/09/05 B3/4 4-2 06/16/06 B3/4 4-2a 02/23/06 B3/4 4-3 02/23/06 B3/4 4-3a 05/18/06 B3/4 4-3b 02/23/06 B3/4 4-3c through B3/4 4-3d 05/18/06 83/4 4-4 02/23/06 B3/4 4-4a 02/23/06 B3/4 4-4b 12/04/08 B3/4 4-4c 12/04/08 B3/4 4-4d 04/11/05 B3/4 4-4e 12/04/08 B3/4 4-4f 12/04/08 B3/4 4-4g 05/18/06 B3/4 4-4h 05/18/06 B3/4 4-4i 02/23/06 83/4 4-4j 02/23/06 B3/4 4-4k 02/23/06 B3/4 4-41 02/23/06 83/4 4-4m 08/04/00 B3/4 4-4n 08/04/00 EPL-18 March 5, 2013
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paqe Revision B3/4 4-23 11/09/04 B3/4 5-1 03/25/10 B3/4 5-2 03/25/10 B3/4 5-3 03/25/10 B3/4 5-4 03/25/10 B3/4 5-5 03/25/10 B3/4 5-6 03/25/10 B3/4 5-7 03/25/10 B3/4 5-8 through B3/4 5-11 03/25/10 B3/4 5-12 through 83/4 5-20 03/24/12 B3/4 6-1 through B3/4 6-2 04/13/09 B3/4 6-3 05/27/10 B3/4 6-4 through B3/4 6-6 04/13/09 B3/4 6-7 through B3/4 6-12 04/13/09 83/4 6-13 through 83/4 6-18 04/13/09 B3/4 6-19 through 83/4 6-20 04/13/09 B3/4 6-21 04/13/09 83/4 7-1 04/30/02 B3/4 7-2 08/14/01 83/4 7-2a 11/17/95 EPL-20 March 24, 2012
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paqe Revision B3/4 7-2b 04/11/05 B3/4 7-3 06/12/09 B3/4 7-3a 06/08/98 B3/4 7-4 09/28/07 B3/4 7-4a 10/05/12 B3/4 7-4b 10/05/12 B3/4 7-4c thru B3/4 7-4m 10/28/08 B3/4 7-5 08/18/05 B3/4 7-6 (DELETED) 08/28/98 B3/4 7-7 12/28/05 B3/4 7-8 08/12/97 B3/4 7-9 12/19/00 B3/4 7-10 12/19/00 B3/4 7-11 12/19/00 B3/4 7-12 12/19/00 B3/4 7-13 12/19/00 B3/4 7-14 12/19/00 B3/4 7-15 12/19/00 B3/4 7-16 01/31/05 B3/4 7-17 02/27/02 B3/4 7-18 02/27/02 B3/4 8-1 12/21/12 B3/4 8-2 12/21/12 B3/4 8-3 12/21/12 B3/4 8-4 12/21/12 B3/4 8-5 12/21/12
- Original pages are not dated (2/29/80).
EPL-21 December 21, 2012
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paqe Revision B3/4 8-6 12/21/12 B3/4 8-7 12/21/12 B3/4 8-8 12/21/12 B3/4 8-9 12/21/12 B3/4 9-1 09/20/04 B3/4 9-2 12/28/05 B3/4 9-3 04/19/04 B3/4 10-1 09/20/04 B3/4 11-1 12/09/93 B3/4 11-2 11/16/90 83/4 12-1 11/16/90 5-1 08/02/06 5-2 08/02/06 5-3 08/02/06 5-4 08/02/06 5-5 12/19/00 5-5a 12/19/00 5-5b 08/02/06 5-5c 12/19/00 5-5d 12/19/00 5-5e 12/19/00 EPL-22 December 21, 2012
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Appendix C Appendix C Cover Sheet 09/06/12 Table of Contents 09/06/12 C-1 09/06/12 C-2 09/06/12 EPL-25 September 6, 2012
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Lower Power License and Technical Specifications issued Amendment 1 issued by NRC Amendment 2 issued by NRC Amendment 3 issued by NRC Amendment 4 issued by NRC Full Power License and Technical Specifications issued NRC Order issued Amendment 1 issued by NRC Amendment 2 issued by NRC Amendment 3 issued by NRC Amendment 4 issued by NRC Amendment 5 issued by NRC Amendment 6 issued by NRC EPL Revised Amendment 7 issued by NRC Amendment 8 issued by NRC Amendment 9 issued by NRC Amendment 10 issued by NRC Amendment 11 issued by NRC Amendment 12 issued by NRC Amendment 13 issued by NRC Amendment 14 issued by NRC Amendment 15 issued by NRC Amendment 16 issued by NRC Amendment 17 issued by NRC Amendment 18 issued by NRC Amendment 19 issued by NRC Amendment 20 issued by NRC Amendment 21 issued by NRC Amendment 22 issued by NRC Amendment 23 issued by NRC Amendment 24 issued by NRC Amendment 25 issued by NRC Amendment 26 issued by NRC Amendment 27 issued by NRC Amendment 28 issued by NRC Amendment 29 issued by NRC
- Amendments to Full Power License 02/29/80 (Original) 04/22/80 (R1) 07/01/80 (R2) 07/01/80 (R2) 07/10/80 (R2) 09/17/80 (R3) 11/06/80 (R4) 12/22/80 (R5) 02/09/81 (R6) 02/13/81 (R6) 03/06/81 (R7) 04/15/81 (R8) 04/27/81 (R9) 06/01/81 (R10) 06/26/81 (R11) 07/15/81 (R12) 09/08/81 (R13) 12/31/81 (R14) 01/29/82 (R15) 03/25/82 (R16) 05/04/82 (R17) 06/18/82 (R18) 08/03/82 (R19) 10/21/82 (R20) 12/23/82 (R21) 12/23/82 (R22) 12/23/82 (R23) 12/23/82 (R24) 12/23/82 (R25) 12/27/82 (R26) 12/27/82 (R27) 12/29/82 (R28) 12/29/82 (R29) 03/14/83 (R30) 03/16/83 (R31) 05/03/83 (R32) 05/05/83 (R33)
EPL-26 September 6, 2012
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Amendment 30 issued by NRC Amendment 31 issued by NRC Amendment 32 issued by NRC Amendment 33 issued by NRC Amendment 34 issued by NRC Amendment 35 issued by NRC Amendment 36 issued by NRC Amendment 37 issued by NRC Amendment 38 issued by NRC Amendment 39 issued by NRC Amendment 40 issued by NRC Amendment 41 issued by NRC Amendment 42 issued by NRC Amendment 43 issued by NRC EPL Revised Amendment 44 issued by NRC Amendment 45 issued by NRC Amendment 46 issued by NRC Amendment 47 issued by NRC Amendment 48 issued by NRC Amendment 49 issued by NRC Amendment 50 issued by NRC Amendment 51 issued by NRC Special Amendment Authorized by NRC**
Amendment 52 issued by NRC Amendment 53 issued by NRC Amendment 54 issued by NRC Amendment 55 issued by NRC Amendment 56 issued by NRC Bases Revision issued by NRC Amendment 57 issued by NRC Amendment 58 issued by NRC Amendment 59 issued by NRC Amendment 60 issued by NRC Amendment 61 issued by NRC Amendment 62 issued by NRC Amendment 63 issued by NRC Amendment 64 issued by NRC Amendment 65 issued by NRC Amendment 66 issued by NRC Additional Exemptions issued by NRC Amendment 67 issued by NRC 05/05/83 (R34) 09/30/83 (R35) 11/10/83 (R36) 03/29/84 (R37) 04/12/84 (R38) 04/24/84 (R39) 11/23/84 (R40) 01/24/85 (R41) 06/11/85 (R42) 06/20/85 (R43) 06/25/85 (R44) 09/03/85 (R45) 01/14/86 (R46) 01/29/86 (R47) 07/17/86 07/28/86 (R48) 09/15/86 (R49) 09/16/86 (R50) 09/17/86 (R51) 10/02/86 (R52) 10/28/86 (R53) 12/01/86 (R54) 12/02/86 (R55) 01/05/87 (SR) 02/03/87 (R56) 02/12/87 (R57) 03/16/87 (R58) 05/12/87 (R59) 07/20/87 (R60) 08/18/87 (BR) 09/09/87 (R61) 09/10/87 (R62) 09/18/87 (R63) 10/19/87 (R64) 10/22/87 (R65) 10/30/87 (R66) 12/31/87 (R67) 01/07/88 (R68) 01/11/88 (R69) 01/25/88 (R70) 01/15/88 (AE) 02/11/88 (R71)
Special Revision authorized by 10 CFR Parts 50 and 51 Final Rule as noted in the Federal Register on November 6, 1986 and effective January 5, 1987.
EPL-27 September 6, 2012
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Amendment 68 issued by NRC Amendment 69 issued by NRC Amendment 70 issued by NRC Amendment 71 issued by NRC Amendment 72 issued by NRC Amendment 73 issued by NRC Amendment 74 issued by NRC Amendment 75 issued by NRC Amendment 76 issued by NRC Amendment 77 issued by NRC Amendment 78 issued by NRC Amendment 79 issued by NRC Amendment 80 issued by NRC Amendment 81 issued by NRC Amendment 82 issued by NRC Amendment 83 issued by NRC Amendment 84 issued by NRC Amendment 85 issued by NRC Amendment 86 issued by NRC Amendment 87 issued by NRC Amendment 88 issued by NRC Amendment 89 issued by NRC Amendment 90 issued by NRC Amendment 91 issued by NRC Amendment 92 issued by NRC Amendment 93 issued by NRC Amendment 94 issued by NRC Amendment 95 issued by NRC Amendment 96 issued by NRC Amendment 97 issued by NRC Amendment 98 issued by NRC Amendment 99 issued by NRC Amendment 100 issued by NRC Amendment 101 issued by NRC Amendment 102 issued by NRC Amendment 103 issued by NRC Amendment 104 issued by NRC Amendment 105 issued by NRC Amendment 106 issued by NRC Amendment 107 issued by NRC Amendment 108 issued by NRC Amendment 109 issued by NRC Amendment 110 issued by NRC Amendment 111 issued by NRC Amendment 112 issued by NRC 02/17/88 (R72) 04/04/88 (R73) 05/16/88 (R74) 05/18/88 (R75) 05/23/88 (R76) 06/24/88 (R77) 06/30/88 (R78) 07/06/88 (R79) 07/12/88 (R80) 08/05/88 (R81) 08/15/88 (R82) 08/15/88 (R83) 08/16/88 (R84) 09/01/88 (R85) 09/09/88 (R86) 09/21/88 (R87) 09/22/88 (R88) 09/22/88 (R89) 10/14/88 (R90) 10/14/88 (R91) 10/14/88 (R92) 10/14/88 (R93) 10/14/88 (R94) 12/05/88 (R95) 12/29/88 (R96) 12/29/88 (R97) 12/30/88 (R98) 01/23/89 (R99) 01/22/89 (R100) 01/22/89 (R101) 01/30/89 (R102) 01/30/89 (R103) 01/31/89 (R104) 02/28/89 (R105) 03/02/89 (R106) 03/06/89 (R107) 03/09/89 (R108) 03/09/89 (R109) 03/13/89 (R110) 03/15/89 (Rl11) 03/28/89 (RI 12) 04/03/89 (R113) 04/03/89 (Ri 14) 04/03/89 (Rl15) 04/28/89 (Ri 16)
September 6, 2012 EPL-28
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Amendment 113 issued by NRC Amendment 114 issued by NRC Amendment 115 issued by NRC Amendment 116 issued by NRC Amendment 117 issued by NRC Amendment 118 issued by NRC Amendment 119 issued by NRC Amendment 120 issued by NRC Amendment 121 issued by NRC Amendment 122 issued by NRC Amendment 123 issued by NRC Amendment 124 issued by NRC Amendment 125 issued by NRC Amendment 126 issued by NRC Amendment 127 issued by NRC Amendment 128 issued by NRC Amendment 129 issued by NRC Amendment 130 issued by NRC Amendment 131 issued by NRC Amendment 132 issued by NRC Amendment 133 issued by NRC Bases Revision Amendment 134 issued by NRC Amendment 135 issued by NRC Amendment 136 issued by NRC Amendment 137 issued by NRC Bases Revision Amendment 138 issued by NRC Amendment 139 issued by NRC Amendment 140 issued by NRC Amendment 141 issued by NRC Amendment 142 issued by NRC Amendment 143 issued by NRC Amendment 144 issued by NRC Amendment 145 issued by NRC Amendment 146 issued by NRC Amendment 147 issued by NRC Amendment 148 issued by NRC Amendment 149 issued by NRC Amendment 150 issued by NRC Amendment 151 issued by NRC Amendment 152 issued by NRC Amendment 153 issued by NRC Amendment 154 issued by NRC Amendment 155 issued by NRC Amendment 156 issued by NRC Amendment 157 issued by NRC Amendment 158 issued by NRC Amendment 159 issued by NRC Amendment 160 issued by NRC 05/04/89 (R117) 05/05/89 (R118) 05/11/89 (R119) 06/01/89 (R 120) 06/19/89 (R121) 06/23/89 (R122) 07/05/89 (R123) 07/05/89 (R124) 07/31/89 (R 125) 08/03/89 (RI126) 08/11/89 (R127) 08/11/89 (R128) 08/14/89 (R129) 09/19/89 (R130) 09/29/89 (R131) 11/01/89 (R132) 11/28/89 (R133) 02/16/90 (R134) 03/02/90 (R135) 03/19/90 (R136) 03/22/90 (R137) 03/23/90 (BR-1) 04/02/90 (R138) 04/27/90 (R139) 04/27/90 (R140) 04/27/90 (R141) 05/01/90 (BR-2) 05/08/90 (R142) 05/09/90 (R143) 05/11/90 (R144) 05/16/90 (R145) 07/27/90 (R146) 07/31/90 (R147) 08/31/90 (R148) 09/20/90 (R149) 09/21/90 (R150) 11/02/90 (R151) 11/16/90 (R152) 12/07/90 (R153) 03/18/91 (R154) 07/24/91 (R155) 08/22/91 (R156) 09/10/91 (R157) 10/18/91 (R158) 10/23/91 (R159) 12/16/91 (R160) 03/30/92 (R161) 03/31/92 (R162) 07/09/92 (R163) 07/24/92 (R164)
September 6, 2012 EPL-29
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Amendment 161 issued by NRC Amendment 162 issued by NRC Amendment 163 issued by NRC Amendment 164 issued by NRC Bases Revision Amendment 165 issued by NRC Bases Revision Amendment 166 issued by NRC Amendment 167 issued by NRC Amendment 168 issued by NRC Amendment 169 issued by NRC Amendment 170 issued by NRC Amendment 171 issued by NRC Amendment 172 issued by NRC Amendment 173 issued by NRC Amendment 174 issued by NRC Amendment 175 issued by NRC Amendment 176 issued by NRC Amendment 177 issued by NRC Amendment 178 issued by NRC Amendment 179 issued by NRC Amendment 180 issued by NRC Amendment 181 issued by NRC Amendment 182 issued by NRC Amendment 183 issued by NRC Amendment 184 issued by NRC Amendment 185 issued by NRC Amendment 186 issued by NRC Amendment 187 issued by NRC Amendment 188 issued by NRC Amendment 189 issued by NRC Amendment 190 issued by NRC Amendment 191 issued by NRC Amendment 192 issued by NRC Amendment 193 issued by NRC Amendment 194 issued by NRC Amendment 195 issued by NRC Bases Revision Amendment 196 issued by NRC Amendment 197 issued by NRC Amendment 198 issued by NRC Amendment 199 issued by NRC Amendment 200 issued by NRC Amendment 201 issued by NRC Amendment 202 issued by NRC Amendment 203 issued by NRC Amendment 204 issued by NRC Amendment 205 issued by NRC Amendment 206 issued by NRC Bases Revision 08/10/92 (R165) 08/13/92 (R166) 09/28/92 (R167) 11/06/92 (R168) 11/25/92 (BR-3) 12/08/92 (R169) 12/08/92 (BR-4) 01/12/93 (R170) 04/28/93 (R171) 06/25/93 (R172) 08/02/93 (R173) 08/27/93 (R174) 10/26/93 (R175) 11/26/93 (R176) 11/29/93 (R177) 12/09/93 (R178) 01/03/94 (R179) 02/10/94 (R180) 03/15/94 (R18 1) 03/31/94 (R 182) 04/18/94 (R183) 04/18/94 (R184) 05/23/94 (R185) 05/24/94 (R186) 05/27/94 (R187) 07/11/94 (R188) 07/26/94 (R189) 09/13/94 (R190) 10/17/94 (R191) 10/17/94 (R192) 10/20/94 (R193) 11/09/94 (R194) 11/22/94 (R195) 12/27/94 (R196) 01/03/95 (R197) 01/24/95 (R198) 02/09/95 (R199) 03/02/95 (BR-5) 04/04/95 (R200) 04/28/95 (R201) 05/10/95 (R202) 05/30/95 (R203) 05/30/95 (R204) 06/01/95 (R205) 06/13/95 (R206) 06/13/95 (R207) 06/14/95 (R208) 06/29/95 (R209) 08/02/95 (R210) 08/11/95 (BR-6)
September 6, 2012 EPL-30
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Amendment 207 issued by NRC Amendment 208 issued by NRC Amendment 209 issued by NRC Amendment 210 issued by NRC Amendment 211 issued by NRC Amendment 212 issued by NRC Amendment 213 issued by NRC Amendment 214 issued by NRC Bases Revision Bases Revision Amendment 215 issued by NRC Amendment 216 issued by NRC Amendment 217 issued by NRC Amendment 218 issued by NRC Bases Revision Amendment 219 issued by NRC Amendment 220 issued by NRC Amendment 221 issued by NRC Bases Revision Bases Revision Amendment 222 issued by NRC Amendment 223 issued by NRC Amendment 224 issued by NRC Amendment 225 issued by NRC Amendment 226 issued by NRC Amendment 227 issued by NRC Amendment 228 issued by NRC Amendment 229 issued by NRC Amendment 230 issued by NRC Amendment 231 issued by NRC Amendment 232 issued by NRC Amendment 233 issued by NRC Amendment 234 issued by NRC Amendment 235 issued by NRC Bases Revision Amendment 236 issued by NRC Amendment 237 issued by NRC Amendment 238 issued by NRC Amendment 239 issued by NRC Amendment 240 issued by NRC Amendment 241 issued by NRC Bases Revision Amendment 242 issued by NRC Amendment 243 issued by NRC Amendment 244 issued by NRC Amendment 245 issued by NRC Amendment 246 issued by NRC Amendment 247 issued by NRC 08/22/95 (R211) 08/22/95 (R212) 09/06/95 (R213) 09/13/95 (R214) 09/15/95 (R215) 10/02/95 (R216) 10/04/95 (R217) 10/11/95 (R218) 10/27/95 (BR-7) 11/17/95 (BR-8) 11/21/95 (R219) 12/11/95 (R220) 02/05/96 (R221) 02/07/96 (R222) 02/15/96 (BR-9) 03/01/96 (R223) 03/04/96 (R224) 04/26/96 (R225) 09/13/96 (BR-1 0) 01/02/97 (BR-11) 04/09/97 (R226) 04/21/97 (R227) 06/10/97 (R228) 07/01/97 (R229) 07/14/97 (R230) 08/12/97 (R231) 09/23/97 (R232) 09/29/97 (R233) 01/13/98 (R234) 02/20/98 (R235) 06/08/98 (R236) 07/01/98 (R237) 07/22/98 (R238) 08/28/98 (R239) 09/09/98 (BR-12) 11/17/98 (R240) 11/17/98 (R241) 11/19/98 (R242) 11/19/98 (R243) 12/07/98 (R244) 12/16/98 (R245) 01/25/99 (BR-13) 02/09/99 (R246) 03/16/99 (R247) 05/04/99 (R248) 09/07/99 (R249) 09/23/99 (R250) 10/06/99 (R251)
EPL-31 September 6, 2012
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Amendment 248 issued by NRC Amendment 249 issued by NRC Amendment 250 issued by NRC Amendment 251 issued by NRC Amendment 252 issued by NRC Amendment 253 issued by NRC Amendment 254 issued by NRC Amendment 255 issued by NRC Bases Revision Bases Revision Amendment 256 issued by NRC Amendment 257 issued by NRC Amendment 258 issued by NRC Amendment 259 issued by NRC Amendment 260 issued by NRC Amendment 261 issued by NRC Amendment 262 issued by NRC Amendment 263 issued by NRC Amendment 264 issued by NRC Amendment 265 issued by NRC Amendment 266 issued by NRC Amendment 267 issued by NRC Amendment 268 issued by NRC Bases Revision Bases Revision Amendment 269 issued by NRC Amendment 270 issued by NRC Bases Revision Bases Revision Amendment 271 issued by NRC Amendment 272 issued by NRC Bases Revision Amendment 273 issued by NRC Amendment 274 issued by NRC Amendment 275 issued by NRC Bases Revision Amendment 276 issued by NRC Amendment 277 issued by NRC Amendment 279 issued by NRC Amendment 280 issued by NRC Amendment 281 issued by NRC Amendment 282 issued by NRC Amendment 283 issued by NRC Amendment 284 issued by NRC Amendment 285 issued by NRC Bases Revision Amendment 286 issued by NRC Amendment 287 issued by NRC Bases Revision 10/12/99 (R252) 02/11/00 (R253) 02/22/00 (R254) 02/29/00 (R255) 03/08/00 (R256) 03/29/00 (R257) 03/29/00 (R258) 04/14/00 (R259) 05/25/00 (BR-14) 05/25/00 (BR-15) 05/31/00 (R260) 07/18/00 (R261) 07/31/00 (R262) 08/04/00 (R263) 08/28/00 (R264) 10/02/00 (R265) 10/06/00 (R266) 11/02/00 (R267) 12/18/00 (R268) 12/19/00 (R269) 02/16/01 (R270) 03/22/01 (R271) 05/09/01 (R272) 06/28/01 (BR-16) 07/11/01 (BR-17) 07/12/01 (R273) 07/18/01 (R274) 07/20/01 (BR-18) 08/14/01 (BR-19) 10/24/01 (R275) 01/14/02 (R276) 02/14/02 (BR-20) 02/27/02 (R277) 03/08/02 (R278) 04/30/02 (R279) 05/17/02 (BR-21) 05/24/02 (R280) 09/05/02 (R281) 09/30/02 (R283) 02/05/03 (R284) 02/11/03 (R285) 03/04/03 (R286) 04/24/03 (R287) 04/25/03 (R288) 05/22/03 (R289) 05/22/03 (BR-22) 05/27/03 (R290) 05/29/03 (R291) 06/26/03 (BR-23)
September 6, 2012 EPL-32
SEQUOYAH NUCLEAR PLANT UNIT I TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Amendment 288 issued by NRC Bases Revision Bases Revision Amendment 290 issued by NRC Amendment 291 issued by NRC Amendment 292 issued by NRC Amendment 293 issued by NRC Amendment 294 issued by NRC Amendment 295 issued by NRC Amendment 296 issued by NRC License Condition Issued by NRC Amendment 297 issued by NRC Bases Revision Amendment 298 issued by NRC Bases Revision Bases Revision Amendment 299 issued by NRC Amendment 300 issued by NRC Amendment 301 issued by NRC Amendment 302 issued by NRC Amendment 303 issued by NRC Amendment 304 issued by NRC Amendment 305 issued by NRC Amendment 306 issued by NRC Amendment 307 issued by NRC Bases Revision Amendment 308 issued by NRC Amendment 309 issued by NRC Amendment 310 issued by NRC Amendment 311 issued by NRC Amendment 312 issued by NRC Amendment 313 issued by NRC Amendment 314 issued by NRC Amendment 315 issued by NRC License Condition Issued by NRC Bases Revision License Condition Issued by NRC Amendment 316 issued by NRC Amendment 317 issued by NRC Bases Revision Amendment 318 issued by NRC Bases Revision Amendment 319 issued by NRC Bases Revision Amendment 320 issued by NRC Amendment 321 issued by NRC Amendment 322 issued by NRC Amendment 323 issued by NRC Amendment 324 issued by NRC Bases Revision Amendment 325 issued by NRC Amendment 326 issued by NRC Amendment 327 issued by NRC 10/28/03 (R292) 12/22/03 (BR-24) 04/19/04 (BR-25) 04/21/04 (R294) 06/18/04 (R295) 05/21/04 (R296) 07/08/04 (R297) 09/15/04 (R298) 09/20/04 (R299) 09/20/04 (R300) 10/28/04 11/09/04 (R301) 10/13/04 (BR-26) 01/31/05 (R302) 02/25/05 (BR-27) 03/04/05 (BR-28) 03/09/05 (R303) 04/05/05 (R304) 04/11/05 (R305) 05/24/05 (R306) 08/18/05 (R307) 09/02/05 (R308) 12/28/05 (R309) 02/23/06 (R310) 04/06/06 (R31 1) 05/18/06 (BR-29) 06/16/06 (R312) 08/02/06 (R313) 09/13/06 (R314) 09/14/06 (R315) 10/04/06 (R316) 11/07/06 (R317) 11/16/06 (R318) 12/11/06 (R319) 02/08/07 03/07/07 (BR-30) 08/09/07 (B.5.b) 09/20/07 (R320) 09/28/07 (R321) 12/12/07 (BR-31) 04/02/08 (R322) 08/29/08 (BR-32) 08/29/08 (R323) 08/28/08 (BR-33) 09/24/08 10/28/08 12/04/08 04/13/09 06/12/09 06/12/09 (BR-34) 08/14/09 01/28/10 02/02/10 September 6, 2012 EPL-33
SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Revisions Bases Revision Bases Revision Amendment 328 issued by NRC Bases Revision Amendment 330 issued by NRC Bases Revision Amendment 332 issued by NRC Bases Revision Bases Revision 03/25/10 (BR-35) 05/27/10 (BR-36) 12/21/10 03/24/12 (BR-38) 09/06/12 10/05/12 (BR-39) 10/31/12 12/21/12 (BR-41) 03/05/13 (BR-42)
EPL-34 March 5, 2013
INDEX BASES SECTION PAGE 3/4.7.4 ESSENTIAL RAW COOLING WATER SYSTEM...........................................................
B 3/4 7-3a 3/4.7.5 U LTIM ATE H EAT SIN K (U HS).........................................................................................
B 3/4 7-4 3/4.7.6 FLO O D P R O T EC T IO N.....................................................................................................
B 3/4 7-4 3/4.7.7 CONTROL ROOM EMERGENCY VENTILATION SYSTEM...........................................
B 3/4 7-4 3/4.7.8 AUXILIARY BUILDING GAS TREATMENT SYSTEM.....................................................
B 3/4 7-5 3/4.7.9 S N U B B E R S (D eleted)....................................................................................................
B 3/4 7-5 3/4.7.10 SEALED SOURCE CONTAMINATION (Deleted)...........................................................
B 3/4 7-7 3/4.7.11 FIRE SUPPRESSION SYSTEMS (Deleted)...................................................................
B 3/4 7-7 3/4.7.12 FIRE BARRIER PENETRATIONS (Deleted)...................................................................
B 3/4 7-8 3/4.7.13 SPENT FUEL POOL MINIMUM BORON CONCENTRATION.........................................
B 3/4 7-9 3/4.7.14 CASK PIT POOL MINIMUM BORON CONCENTRATION............................................
B 3/4 7-13 3/4.7.15 CONTROL ROOM AIR-CONDITIONING SYSTEM (CRACS).......................................
B 3/4 7-16 3/4.8 ELECTRICAL POWER SYSTEMS 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER D IST R IBU T IO N SY ST EM S..............................................................................................
B 3/4 8-1 3/4.8.3 ELECTRICAL EQUIPMENT PROTECTIVE DEVICES (Deleted)...................................
B 3/4 8-9 3/4.9 REFUELING OPERATIONS 3/4.9.1 BO RO N C O NC ENTRATIO N............................................................................................
B 3/4 9-1 3/4.9.2 IN ST R U M E N TA T IO N.......................................................................................................
B 3/4 9-1 3/4.9.3 D E C A Y T IM E....................................................................................................................
B 3/4 9-1 3/4.9.4 CONTAINMENT BUILDING PENETRATIONS................................................................
B 3/4 9-1 3/4.9.5 COMMUNICATIONS (Deleted).......................................................................................
B 3/4 9-2 3/4.9.6 MANIPULATOR CRANE (Deleted).................................................................................
B 3/4 9-2 3/4.9.7 CRANE TRAVEL - SPENT FUEL PIT AREA (Deleted)..................................................
B 3/4 9-2 3/4.9.8 RESIDUAL HEAT REMOVAL AND COOLANT CIRCULATION......................................
B 3/4 9-2 3/4.9.9 CONTAINMENT VENTILATION SYSTEM.......................................................................
B 3/4 9-3 December 21, 2012 SEQUOYAH - UNIT 1 XIV Amendment No. 157, 204, 227, 235, 265, 273, 305, 332
INSTRUMENTATION BASES ACCIDENT MONITORING INSTRUMENTATION (Continued)
Provide information to the operators that will enable them to determine the likelihood of a gross breach of the barriers to radioactivity release and to determine if a gross breach of a barrier has occurred.
For Sequoyah, the redundant channel capability for Auxiliary Feedwater (AFW) flow consists of a single AFW flow channel for each Steam Generator with the second channel consisting of three AFW valve position indicators (two level control valves for the motor driven AFW flowpath and one level control valve for the turbine driven AFW flowpath) for each steam generator.
March 5, 2013 SEQUOYAH - UNIT 1 B3/4 3-3a Amendment No. 149, 159
RCS Pressure and Temperature (PIT) Limits B 3/4.4.9 TABLE B 3/4.4-1 SEQUOYAH-UNIT 1 REACTOR VESSEL TOUGHNESS DATA MATERIAL Cu Ni NDT MINIMUM RTNDT AVERAGE UPPER COMPONENT HEAT NO.
GRADE
(%)
(%)
(OF) 50 ft-lb/35 mil temp.
(OF)
SHELF ENERGY TEMP.(0F)
(ft-lb)
PMWD1 NMWD2 PMWD1 NMWD2 Clos Hd. Dome 52841-1 A533B,C1.1
-40
+14
+34
-26 104a Clos Hd. Ring (D75600)
A508,C1.2
+ 5
+36
+56*
+5 125a Hd Flange 4842 A508,C1.2
-40
-24
-4*
-40 131a Vessel Flange 4866 A508,C1.2
-49
-47
-27
-49 158a Inlet Nozzle 4846 A508,CI.2
-58
+25
+45
-15 94.5a Inlet Nozzle 4949 A508,C1.2
-40
+39
+59*
-1 93a Inlet Nozzle 4863 A508,C1.2
-22
+16
+36*
-22 118a Inlet Nozzle 4865 A508,C1.2
-67
+9
+29*
-31 94a Outlet Nozzle 4845 A508,C1.2
-49
+21
+41*
-19 948 Outlet Nozzle 4850 A508,C1.2
-58
+30
+50*
-10 79.5a Outlet Nozzle 4862 A508,C1.2
-58
+16
+36*
-24 103a Outlet Nozzle 4864 A508,C1.2
-49 0
+20
-40 126a Upper Shell 4841 A508,C1.2
-40
+43
+83
+23 83a 113' Inter Shell 4829 A508,C1.2 0.15 0.86
-4
+10
+100
+40 116 73b'c Lower Shell 4836 A508,C1.2 0.13 0.76
+5
+28
+133
+73 109 70b Trans. Ring 4879 A508,CI.2
+5
+27
+47*
+ 5 98a Bot. Hd. Rim 52703/2-1 A533B,C1.1
-31
+23
+43*
-17 104a Bot. Hd. Rim 52703/2-2 A533B,C1.1
-13
+36
+56*
-4 638 Bot. Hd. Rim 52704/2 A533B,C1.1
-49
-24
-4*
-49 114a Bot. Hd. Rim 52703/2-2 A533B,C1.1
-31
+43
+63*
+3 86a Bot. Hd. Rim 52704/2 A533B,C1.1
-58
-13
+4
-53 120a Bot. Hd.
52704/11 A533B,C1.1
-58
-47
-27*
-58 139a Weld Weld 0.33 0.17
-40
-4
-22
+41
-19 86b 1-Paralled to Major Working Direction 2-Normal to Major Working Direction a-%Shear Not reported b-Minimum upper shelf energies c-Minimum upper shelf energy decreased to 51 at a test temperature of 3000F. This anomaly will be reevaluted when the results of Generic task A-i 1 are available.
- Estimate based on USAEC Regulatory Standard Review Plan, Section 5.3.2 MTEB November 9, 2004 Amendment No. 158, 294, 297 SEQUOYAH UNIT 1 B 3/4 4-12
ECCS - Shutdown B 3/4.5.3 B 3/4.5 EMERGENCY CORE COOLING SYSTEM (ECCS)
B 3/4.5.3 ECCS - Shutdown BASES BACKGROUND The Background section for Bases 3.5.2, "ECCS - Operating," is applicable to these Bases, with the following modifications. In MODE 4, the required ECCS train consists of two separate subsystems: centrifugal charging (high head) and residual heat removal (RHR) (low head). For the RHR subsystem during the injection phase, water is taken from the refueling storage tank (RWST) and injected in the Reactor Coolant System (RCS) through at least two cold legs.
The ECCS flow paths consist of piping, valves, heat exchangers, and pumps such that water from the refueling water storage tank (RWST) can be injected into the Reactor Coolant System (RCS) following the accidents described in Bases 3.5.2.
APPLICABLE SAFETY ANALYSES The Applicable Safety Analyses section of Bases 3.5.2 also applies to this Bases section.
Due to the stable conditions associated with operation in MODE 4 and the reduced probability of occurrence of a Design Basis Accident (DBA), the ECCS operational requirements are reduced. It is understood in these reductions that certain automatic safety injection (SI) actuation is not available. In this MODE, sufficient time exists for manual.actuation of the required ECCS to mitigate the consequences of a DBA.
Only one train of ECCS is required for MODE 4. This requirement dictates that single failures are not considered during this MODE of operation.
One train of ECCS during the injection phase provides sufficient flow for core cooling, by the centrifugal charging subsystem supplying each of the four cold legs and the RHR subsystem supplying at least two cold legs, to meet the analysis requirements for a credible Mode 4 Loss of Coolant Accident (LOCA.)
The ECCS trains satisfy Criterion 3 of 10 CFR 50.36(c)(2)(ii).
LCO In MODE 4, one of the two independent (and redundant) ECCS trains is required to be OPERABLE to ensure that sufficient ECCS flow is available to the core following a DBA.
SEQUOYAH - UNIT 1 March 24, 2012 BR35, BR38 B 3/4 5-12
ECCS - Shutdown B 3/4.5.3 BASES LCO (continued)
In MODE 4, an ECCS train consists of a centrifugal charging subsystem and an RHR subsystem. Each train includes the piping, instruments, and controls to ensure an OPERABLE flow path capable of taking suction from the RWST and transferring suction to the containment sump During an event requiring ECCS actuation, a flow path is required to provide an abundant supply of water from the RWST to the RCS via the ECCS pumps and their respective supply headers to the cold leg injection nozzles. In the long term, this flow path may be switched to take its supply from the containment sump and to deliver its flow to the RCS hot and cold legs.
Either RHR cold leg injection valve FCV-63-93 or FCV-63-94 may be closed when in Mode 4, for testing of the primary/secondary check valves in the injection lines. Closing one of the two cold leg injection flow paths does not make ECCS RHR subsystem inoperable.
This LCO is modified by a Note that allows an RHR train to be considered OPERABLE during alignment and operation for decay heat removal, if capable of being manually realigned (remote or local) to the ECCS mode of operation and not otherwise inoperable. The manual actions necessary to realign the RHR subsystem may include actions to cool the RHR system piping due to the potential for steam voiding in piping or for inadequate NPSH available at the RHR pumps. This allows operation in the RHR mode during MODE 4.
APPLICABILITY In MODES 1, 2, and 3, the OPERABILITY requirements for ECCS are covered by LCO 3.5.2.
In MODE 4 with RCS temperature below 350°F, one OPERABLE ECCS train is acceptable without single failure consideration, on the basis of the stable reactivity of the reactor and the limited core cooling requirements.
In MODES 5 and 6, plant conditions are such that the probability of an event requiring ECCS injection is extremely low. Core cooling requirements in MODE 5 are addressed by LCO 3.4.1.4, "Reactor Coolant System Cold Shutdown." MODE 6 core cooling requirements are addressed by LCO 3.9.8.1 "Residual Heat Removal and Coolant Circulation - All Water Levels," and LCO 3.9.8.2 "Residual Heat Removal and Coolant Circulation - Low Water Level."
March 24, 2012 SEQUOYAH - UNIT 1 B 3/4 5-13 BR35, BR36, BR38
ECCS - Shutdown B 3/4.5.3 BASES ACTIONS A Note prohibits the application of LCO 3.0.4b to an inoperable ECCS high head subsystem when entering MODE 4. There is an increased risk associated with entering MODE 4 from MODE 5 with an inoperable ECCS high head subsystem and the provisions of LCO 3.0.4b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
A second Note allows the required ECCS RHR subsystem to be inoperable because of surveillance testing of RCS pressure isolation valve leakage (FCV-74-1 and FCV-74-2). This allows testing while RCS pressure is high enough to obtain valid leakage data and following valve closure for RHR decay heat removal path. The condition requiring alternate heat removal methods ensures that the RCS heatup rate can be controlled to prevent MODE 3 entry and thereby ensure that the reduced ECCS operational requirements are maintained. The condition requiring manual realignment capability, FCV-74-1 and FCV-74-2 can be opened from the main control room ensures that in the unlikely event of a DBA during the one hour of surveillance testing, the RHR subsystem can be placed in ECCS recirculation mode when required to mitigate the event.
Action a.
With no ECCS RHR subsystem OPERABLE, the plant is not prepared to respond to a loss of coolant accident or to continue a cooldown using the RHR pumps and heat exchangers. The action time of immediately to initiate actions that would restore at least one ECCS RHR subsystem to OPERABLE status ensures that prompt action is taken to restore the required cooling capacity. Normally, in MODE 4, reactor decay heat is removed from the RCS by an RHR loop. If no RHR loop is OPERABLE for this function, reactor decay heat must be removed by some alternate method, such as use of the steam generators. The alternate means of heat removal must continue until the inoperable RHR loop components can be restored to operation so that decay heat removal is continuous.
With both RHR pumps and heat exchangers inoperable, it would be unwise to require the plant to go to MODE 5, where the only available heat removal system is the RHR. Therefore, the appropriate action is to initiate measures to restore one ECCS RHR subsystem and to continue the actions until the subsystem is restored to OPERABLE status.
March 24, 2012 SEQUOYAH - UNIT 1 B 3/4 5-14 BR35
BASES ACTIONS (continued)
Action b.
With no ECCS high head subsystem OPERABLE, due to the inoperability of the centrifugal charging pump or flow path from the RWST, the plant is not prepared to provide high pressure response to Design Basis Events requiring SI. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> action time to restore at least one ECCS high head subsystem to OPERABLE status ensures that prompt action is taken to provide the required cooling capacity or to initiate actions to place the plant in MODE 5, where an ECCS train is not required.
When Action b cannot be completed within the required action time, within one hour, a controlled shutdown should be initiated. Twenty four hours is a reasonable time, based on operating experience, to reach MODE 5 in an orderly manner and without challenging plant systems or operators.
SURVEILLANCE SR 4.5.3 REQUIREMENTS The applicable Surveillance descriptions from Bases 3.5.2 apply.
REFERENCES
- 1. The applicable references from Bases 3.5.2 apply.
- 2. NRC Safety Evaluation Report, NUREG-001 1, Section 1.1, "Introduction," regarding Amendment 49 dated January 6, 1978.
March 24, 2012 BR35, BR38 SEQUOYAH - UNIT 1 B 3/4 5-15
EMERGENCY CORE COOLING SYSTEMS BASES 3/4.5.4 BORON INJECTION SYSTEM This specification was deleted.
3/4.5.5 REFUELING WATER STORAGE TANK The OPERABILITY of the RWST as part of the ECCS ensures that a sufficient supply of borated water is available for injection by the ECCS in the event of a LOCA. The limits on RWST minimum volume and boron concentration ensure that 1) sufficient water is available within containment to permit recirculation cooling flow to the core, and 2) the reactor will remain subcritical in the cold condition following mixing of the RWST and the RCS water volumes with all control rods inserted except for the most reactive control assembly. These assumptions are consistent with the LOCA analyses.
Additionally, the OPERABILITY of the RWST as part of the ECCS ensures that sufficient negative reactivity is injected into the core to counteract any positive increase in reactivity caused by RCS cooldown.
The contained water volume limit includes an allowance for water not usable because of tank discharge line location or other physical characteristics.
The limits on contained water volume and boron concentration of the RWST also ensure a pH value of between 7.5 and 9.5 for the solution recirculated within containment after a LOCA.
This pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion on mechanical systems and components.
March 24, 2012 SEQUOYAH - UNIT 1 B 3/4 5-16 Amendment No. 140, 301
EMERGENCY CORE COOLING SYSTEM BASES 3/4.5.6 SEAL INJECTION FLOW BACKGROUND The function of the seal injection throttle valves during an accident is similar to the function of the ECCS throttle valves in that each restricts flow from the centrifugal charging pump header to the Reactor Coolant System (RCS).
The restriction on reactor coolant pump (RCP) seal injection flow limits the amount of ECCS flow that would be diverted from the injection path following an accident. This limit is based on safety analysis assumptions that are required because RCP seal injection flow is not isolated during safety injection.
APPLICABLE All ECCS subsystems are taken credit for in the large break loss of SAFETY ANALYSES coolant accident (LOCA) at full power (Ref. 1). The LOCA analysis establishes the minimum flow for the ECCS pumps. The centrifugal charging pumps are also credited in the small break LOCA analysis. This analysis establishes the flow and discharge head at the design point for the centrifugal charging pumps. The steam generator tube rupture and main steam line break event analyses also credit the centrifugal charging pumps, but are not limiting in their design. Reference to these analyses is made in assessing changes to the Seal Injection System for evaluation of their effects in relation to the acceptance limits in these analyses.
This LCO ensures that seal injection flow will be sufficient for RCP seal integrity but limited so that the ECCS trains will be capable of delivering sufficient water to match boiloff rates soon enough to minimize uncovering of the core following a large LOCA. It also ensures that the centrifugal charging pumps will deliver sufficient water for a small LOCA and sufficient boron to maintain the core subcritical. For smaller LOCAs, the charging pumps alone deliver sufficient fluid to overcome the loss and maintain RCS inventory. Seal injection flow satisfies Criterion 2 of the NRC Policy Statement.
LCO The intent of the LCO limit on seal injection flow is to make sure that flow through the RCP seal water injection line is low enough to ensure that sufficient centrifugal charging pump injection flow is directed to the RCS via the injection points (Ref. 2).
March 24, 2012 Amendment No. 259 SEQUOYAH - UNIT 1 B 3/4 5-17
EMERGENCY CORE COOLING SYSTEM BASES LCO (continued)
The LCO is not strictly a flow limit, but rather a flow limit based on a flow line resistance. In order to establish the proper flow line resistance, a pressure and flow must be known. The flow line resistance is established by adjusting the RCP seal injection needle valves to provide a total seal injection flow in the acceptable region of Technical Specification Figure 3.5.6-1. The centrifugal charging pump discharge header pressure remains essentially constant through all the applicable MODES of this LCO. A reduction in RCS pressure would result in more flow being diverted to the RCP seal injection line than at normal operating pressure.
The valve settings established at the prescribed centrifugal charging pump discharge header pressure result in a conservative valve position should RCS pressure decrease. The flow limits established by Technical Specification Figure 3.5.6-1 are consistent with the accident analysis.
The limits on seal injection flow must be met to render the ECCS OPERABLE. If these conditions are not met, the ECCS flow will not be as assumed in the accident analyses.
APPLICABILITY In MODES 1, 2, and 3, the seal injection flow limit is dictated by ECCS flow requirements, which are specified for MODES 1, 2, 3, and 4. The seal injection flow limit is not applicable for MODE 4 and lower, however, because high seal injection flow is less critical as a result of the lower initial RCS pressure and decay heat removal requirements in these MODES. Therefore, RCP seal injection flow must be limited in MODES 1, 2, and 3 to ensure adequate ECCS performance.
ACTION With the seal injection flow exceeding its limit, the amount of charging flow available to the RCS may be reduced. Under this condition, action must be taken to restore the flow to below its limit. The operator has 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> from the time the flow is known to be above the limit to correctly position the manual valves and thus be in compliance with the accident analysis. The completion time minimizes the potential exposure of the plant to a LOCA with insufficient injection flow and provides a reasonable time to restore seal injection flow within limits. This time is conservative with respect to the completion times of other ECCS LCOs; it is based on operating experience and is sufficient for taking corrective actions by operations personnel.
March 24, 2012 Amendment No. 259 SEQUOYAH - UNIT 1 B 3/4 5-18
EMERGENCY CORE COOLING SYSTEM BASES ACTIONS(continued)
When the actions cannot be completed within the required completion time, a controlled shutdown must be initiated. The completion time of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> for reaching MODE 3 from MODE 1 is a reasonable time for a controlled shutdown, based on operating experience and normal cooldown rates, and does not challenge plant safety systems or operators. Continuing the plant shutdown from MODE 3, an additional 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is a reasonable time, based on operating experience and normal cooldown rates, to reach MODE 4, where this LCO is no longer applicable.
SURVEILLANCE Surveillance 4.5.6 REQUIREMENTS Verification every 31 days that the manual seal injection throttle valves are adjusted to give a flow within the limit ensures that proper manual seal injection throttle valve position, and hence, proper seal injection flow, is maintained. The differential pressure that is above the reference minimum value is established between the charging header (PT 62-92) and the RCS, and total seal injection flow is verified to be within the limits determined in accordance with the ECCS safety analysis (Ref. 3). The seal water injection flow limits are shown in Technical Specification Figure 3.5.6-1. The frequency of 31 days is based on engineering judgment and is consistent with other ECCS valve surveillance frequencies. The frequency has proven to be acceptable through operating experience.
The requirements for charging flow vary widely according to plant status and configuration. When charging flow is adjusted, the positions of the air-operated valves, which control charging flow, are adjusted to balance the flows through the charging header and through the seal injection header to ensure that the seal injection flow to the RCPs is maintained between 8 and 13 gpm per pump. The reference minimum differential pressure across the seal injection needle valves ensures that regardless of the varied settings of the charging flow control valves that are required to support optimum charging flow, a reference test condition can be established to ensure that flows across the needle valves are within the safety analysis. The values in the safety analysis for this reference set of conditions are calculated based on conditions during power operation and they are correlated to the minimum ECCS flow to be maintained under the most limiting accident conditions.
March 24, 2012 SEQUOYAH - UNIT 1 B 3/4 5-19 Amendment No. 259
EMERGENCY CORE COOLING SYSTEM BASES As noted, the surveillance is not required to be performed until 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> after the RCS pressure has stabilized within a +/- 20 psig range of normal operating pressure. The RCS pressure requirement is specified since this configuration will produce the required pressure conditions necessary to assure that the manual valves are set correctly. The exception is limited to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> to ensure that the surveillance is timely. Performance of this surveillance within the 4-hour allowance is required to maintain compliance with the provisions of Specification 4.0.3.
REFERENCES 1. FSAR, Chapter 6.3 "Emergency Core Cooling System" and Chapter 15.0 "Accident Analysis."
- 2. 10 CFR 50.46.
- 3. Westinghouse Electric Company Calculation CN-FSE-99-48 March 24, 2012 Amendment No. 259 SEQUOYAH - UNIT 1 B 3/4 5-20
UHS B 3/4.7.5 BASES LCO (continued) head (NPSH), and without exceeding the maximum design temperature of the equipment served by the ERCW. To meet this condition, the UHS temperature should not exceed 87°F, when the ERCW System is not in the alignment to support large heavy load lifts associated with the Unit 2 refueling outage 18 steam generator replacement project, and the level should not fall below the 674 feet mean sea level during normal unit operation. When the ERCW System is in the alignment to support large heavy load lifts associated with the Unit 2 refueling outage 18 steam generator replacement project, the UHS temperature should not exceed 74 0F. The alignment to support these large heavy load lifts, which maintains the ERCW System OPERABLE in the event of large heavy load drop, is described in Appendix C, "Additional Conditions," of the Operating License.
APPLICABILITY In MODES 1, 2, 3, and 4, the UHS is required to support the OPERABILITY of the equipment serviced by the UHS and required to be OPERABLE in these MODES.
In MODE 5 or 6, the OPERABILITY requirements of the UHS are determined by the systems it supports.
ACTIONS The maximum allowed UHS temperature value is based on temperature limitations of the equipment that is relied upon for accident mitigation and safe shutdown of the unit and the configuration of the ERCW System.
Measurement of this temperature is in accordance with NUREG/CR-3659 methodology which includes measurement uncertainties (Ref: 5).
With average water temperature of the UHS < 870F (when the ERCW System is not in the alignment to support large heavy load lifts) or 5 74 0F (when the ERCW System is in the alignment to support large heavy load lifts), the associated design basis assumptions remain bounded for all accidents, transients, and shutdown. Long-term cooling capability is provided to the Emergency Core Cooling System (ECCS) and Emergency Diesel Generator loads.
If the water temperature of the UHS exceeds the limits of the LCO, the unit must be placed in a MODE in which the LCO does not apply. To achieve this status, the unit must be placed in at least MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in MODE 5 within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.
SEQUOYAH - UNIT 1 B 3/4 7-4a October 5, 2012 Amendment No. 8, 79, 247, 273, 317, 330
UHS B 3/4.7.5 BASES SURVEILLANCE REQUIREMENTS SR 4.7.5.1 This SR verifies that the ERCW is available to cool the CCS to at least its maximum design temperature with the maximum accident or normal design heat loads for 30 days following a Design Basis Accident.
This SR also verifies that adequate long-term (30 day) cooling can be maintained. The specified level ensures that sufficient reservoir volume exists at the initiation of a LBLOCA concurrent with loss of downstream dam to meet the short-term recovery. NPSH of the ERCW pumps are not challenged with loss of downstream dam. The 24-hour Frequency is based on operating experience related to trending of the parameter variations during the applicable MODES.
SR verifies that the average water temperature of the UHS is < 870F (when the ERCW Sysem is not in the alignment to support large heavy load lifts) and < 74°F (when the ERCW System is in the alignment to support large heavy load lifts) and that the UHS water level is > 674 feet mean sea level.
REFERENCES
- 1.
UFSAR, Section 9.2.5, Ultimate Heat Sink
- 2.
UFSAR, Section 6.2.1, Containment Functional Design
- 3.
UFSAR, Section 9.2.2, Essential Raw Cooling Water (ERCW)
- 4.
Regulatory Guide 1.27 RO, "Ultimate Heat Sink For Nuclear Power Plants," 1972
- 5.
NUREG/CR-3659, "A Mathematical Model For Assessing The Uncertainties Of Instrumentation Measurements For Power And Flow Of PWR Reactors," February 1985.
SEQUOYAH - UNIT 1 October 5, 2012 B 3/4 7-4b Amendment No. 8, 79, 247, 273, 317, 330
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS The OPERABILITY of the A.C. and D.C power sources and associated distribution systems during operation ensures that sufficient power will be available to supply the safety related equipment required for 1) the safe shutdown of the facility and 2) the mitigation and control of accident conditions within the facility. The minimum specified independent and redundant A.C. and D.C. power sources and distribution systems satisfy the requirements of General Design Criteria 17 of Appendix "A" to 10 CFR 50.
The electrically powered AC safety loads are separated into redundant load groups such that loss of any one load group will not prevent the minimum safety functions from being performed. Specification 3.8.1.1 requires two physically independent circuits between the offsite transmission network and the onsite Class 1 E Distribution System and four separate and independent diesel generator sets to be OPERABLE in MODES 1, 2, 3, and 4. These requirements ensure availability of the required power to shut down the reactor and maintain it in a safe shutdown condition after an abnormal operational transient or a postulated design basis accident.
Each offsite circuit must be capable of maintaining rated frequency and voltage, and accepting required loads during an accident. Minimum required switchyard voltages are determined by evaluation of plant accident loading and the associated voltage drops between the transmission network and these loads. These minimum voltage values are provided to TVA's Transmission Operations for use in system studies to support operation of the transmission network in a manner that will maintain the necessary voltages. Transmission Operations is required to notify SQN Operations if it is determined that the transmission network may not be able to support accident loading or shutdown operations as required by 10 CFR 50, Appendix A, GDC-17. Any offsite power circuits supplied by that transmission network that are not able to support accident loading or shutdown operations are inoperable.
The unit station service transformers (USSTs) utilize auto load tap changers to provide the required voltage response for accident loading. The load tap changer associated with a USST is required to be functional and in "automatic" for the USST to supply power to a 6.9 kV Unit Board.
The inability to supply offsite power to a 6.9 kV Shutdown Board constitutes the failure of only one offsite circuit, as long as offsite power is available to the other load group's Shutdown Boards. Thus, if one or both 6.9 kV Shutdown Boards in a load group do not have an offsite circuit available, then only one offsite circuit would be inoperable. If one or more Shutdown Boards in each load group, or all four Shutdown Boards, do not have an offsite circuit available, then both offsite circuits would be inoperable.
An "available" offsite circuit meets the requirements of GDC-17, and is either connected to the 6.9 kV Shutdown Boards or can be connected to the 6.9 kV Shutdown Boards within a few seconds.
An offsite circuit consists of all breakers, transformers, switches, interrupting devices, cabling, and controls required to transmit power from the offsite transmission network (beginning at the switchyard) to one load group of Class 1 E 6.9 kV Shutdown Boards (ending at the supply side of the normal or alternate supply circuit breaker). Each required offsite circuit is that combination of power sources described below that are normally connected to the Class 1 E distribution system, or can be connected to the Class 1 E distribution system through automatic transfer at the 6.9 kV Unit Boards.
The following offsite power configurations meet the requirements of LCO 3.8.1.1.a:
(Note that common station service transformer (CSST) B is a spare transformer with two sets of secondary windings that can be used to supply a total of two Start Buses for CSST A and/or CSST C, with each supplied Start Bus on a separate CSST B secondary winding.)
December 21, 2012 SEQUOYAH - UNIT 1 B 3/4 8-1 Amendment No. 12, 137, 173, 205, 241, 281,332
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
- 1.
Two offsite circuits consisting of a AND b (no board transfers required; a loss of either circuit will not prevent the minimum safety functions from being performed):
- a.
From the 161 kV transmission network, through CSST A (winding X) to Start Bus 1A to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board 1C), and CSST A (winding Y) to Start Bus 2A to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C); AND
- b.
From the 161 kV transmission network, through CSST C (winding X) to Start Bus 2B to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B), and CSST C (winding Y) to Start Bus 1B to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board IB).
- 2.
Two offsite circuits consisting of a AND b (relies on automatic transfer from alignment a.1) to b.2)(b),
or a.2) to b.1)(a) on a loss of USSTs 1A and 11B, OR relies on automatic transfer from alignment a.3) to b.2)(a), or a.4) to b.1)(b) on a loss of USSTs 2A and 2B):
- a.
Normal power source alignments
- 1) From the 500 kV switchyard through USST 1A to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B);
- 2)
From the 500 kV switchyard through USST 1 B to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board lC);
- 3)
From the 161 kV switchyard through USST 2A to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B); AND
- 4) From the 161 kV switchyard through USST 2B to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C).
- b.
Alternate power source alignments
- 1) From the 161 kV transmission network, through:
(a) CSST A (winding X) to Start Bus 1A to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board 1C); AND (b) CSST A (winding Y) to Start Bus 2A to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C); OR
- 2)
From the 161 kV transmission network, through:
(a) CSST C (winding X) to Start Bus 2B to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B), AND (b) CSST C (winding Y) to Start Bus 1B to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B).
December 21, 2012 SEQUOYAH - UNIT I B 3/4 8-2 Amendment No. 12, 137, 173, 205, 234, 241,261,285, 301,332
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
- 3.
Two offsite circuits consisting of a AND b (relies on automatic transfer from alignment a.1) to b.1) and b.2) on a loss of the Unit 2 USSTs; a loss of alignment a.2) or a.3) will not prevent the minimum safety functions from being performed):
- a.
Normal power source alignments
- 1) From the 161 kV switchyard through USST 2A to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B), and USST 2B to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C);
- 2)
From the 161 kV transmission network, through CSST A (winding X) to Start Bus 1A to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board 1 C); AND
- 3)
From the 161 kV transmission network, through CSST C (winding Y) to Start Bus 1 B to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B).
- b.
Alternate power source alignments
- 1) From the 161 kV transmission network, through CSST A (winding Y) to Start Bus 2A to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C); AND
- 2)
From the 161 kV transmission network, through CSST C (winding X) to Start Bus 2B to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B).
- 4.
Two offsite circuits consisting of a AND b (relies on automatic transfer from alignment a.1) to b.1) and b.2) on a loss of the Unit 1 USSTs; a loss of alignment a.2) or a.3) will not prevent the minimum safety functions from being performed):
- a.
Normal power source alignments
- 1) From the 500 kV switchyard through USST 1A to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B), and USST 1B to 6.9 kV Shutdown Board 1B-B (through 6.9 kV Unit Board 1C);
- 2)
From the 161 kV transmission network, through CSST A (winding Y) to Start Bus 2A to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C); AND
- 3)
From the 161 kV transmission network, through CSST C (winding X) to Start Bus 2B to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B).
- b.
Alternate power source alignments
- 1) From the 161 kV transmission network, through CSST A (winding X) to Start Bus 1A to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board 1C); AND
- 2)
From the 161 kV transmission network, through CSST C (winding Y) to Start Bus 1 B to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B).
December 21, 2012 SEQUOYAH - UNIT 1 B 3/4 8-3 Amendment No. 12, 137, 173, 205, 234, 261,285, 332
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
Other offsite power configurations are possible using different combinations of available USSTs and CSSTs, as long as the alignments are consistent with the analyzed configurations, and the alignments otherwise comply with the requirements of GDC 17.
For example, to support breaker testing, offsite power to the 6.9 kV Shutdown Boards can be realigned from normal feed to alternate feed. This would result in Shutdown Boards 1A-A and 2A-A being fed from Unit Boards 1A and 2A, respectively, and Shutdown Boards 1B-B and 2B-B being fed from Unit Boards 1 D and 2D, respectively. The CSST being utilized as the alternate power source to one load group of Shutdown Boards would also be realigned (normally CSST A available to Shutdown Boards 1 B-B and 2B-B or CSST C available to Shutdown Boards 1A-A and 2A-A, would be realigned to CSST A available to Shutdown Boards 1A-A and 2A-A or CSST C available to Shutdown Boards 1 B-B and 2B-B).
LCO 3.8.1.1 is modified by Note @ that specifies CSST A and CSST C are required to be available via automatic transfer at the associated 6.9 KV Unit Boards, when USST 2A and USST 2B are being utilized as normal power sources to the offsite circuits. (Note that CSST B can be substituted for CSST A or CSST C.) This offsite power alignment is consistent with Configuration 3, as stated above.
Note @ remains in effect until November 30, 2013, or until the USST modifications are implemented on Units 1 and 2, whichever occurs first. (The scheduled startup from the Unit 1 fall 2013 refueling outage is November 2013.) Following expiration of Note @, Configuration 3 can continue to be used.
The ACTION requirements specified for the levels of degradation of the power sources provide restriction upon continued facility operation commensurate with the level of degradation. The OPERABILITY of the power sources are consistent with the initial condition assumptions of the accident analyses and are based upon maintaining at least one redundant set of onsite A.C. and D.C. power sources and associated distribution systems OPERABLE during accident conditions coincident with an assumed loss of offsite power and single failure of the other onsite A.C. source.
The footnote for Action b of LCO 3.8.1.1 requires completion of a determination that the OPERABLE diesel generators are not inoperable due to common cause failure or performance of Surveillance 4.8.1.1.2.a.4 if Action b is entered. The intent is that all diesel generator inoperabilities must be investigated for common cause failures regardless of how long the diesel generator inoperability persists.
Action b of LCO 3.8.1.1 is further modified by a second note which precludes making more than one diesel generator inoperable on a pre-planned basis for maintenance, modifications, or surveillance testing. The intent of this footnote is to explicitly exclude the flexibility of removing a diesel generator set from service as a part of a pre-planned activity. While the removal of a diesel generator set (A or B train) is consistent with the initial condition assumptions of the accident analysis, this configuration is judged as imprudent. The term pre-planned is to be taken in the context of those activities which are routinely scheduled and is not relative to conditions which arise as a result of emergent or unforeseen events. As an example, this footnote is not intended to preclude the actions necessary to perform the common mode testing requirements required by Action b. As another example, this footnote is not intended to prevent the required surveillance testing of the diesel generators should one diesel generator maintenance be unexpectedly extended and a second diesel generator fall within its required testing frequency. Thus, application of the note is intended for pre-planned activities.
December 21, 2012 SEQUOYAH - UNIT 1 B 3/4 8-4 Amendment No. 12, 137, 173, 205, 241, 281,332
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
In addition, this footnote is intended to apply only to those actions taken directly on the diesel generator. For those actions taken relative to common support systems (e.g. ERCW), the support function must be evaluated for impact on the diesel generator.
The action to determine that the OPERABLE diesel generators are not inoperable due to common cause failure provides an allowance to avoid unnecessary testing of OPERABLE diesel generators. If it can be determined that the cause of the inoperable diesel generator does not exist on the OPERABLE diesel generators, Surveillance Requirement 4.8.1.1.2.a.4 does not have to be performed. If the cause of inoperability exists on other diesel generator(s), the other diesel generator(s) would be declared inoperable upon discovery and Action e of LCO 3.8.1.1 would be entered as applicable. Once the common failure is repaired, the common cause no longer exists, and the action to determine inoperability due to common cause failure is satisfied. If the cause of the initial inoperable diesel generator cannot be confirmed not to exist on the remaining diesel generators, performance of Surveillance 4.8.1.1.2.a.4 suffices to provide assurance to continued OPERABILITY of the other diesel generators.
According to Generic Letter 84-15, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is reasonable to confirm that the OPERABLE diesel generators are not affected by the same problem as the inoperable diesel generator.
Action f prohibits the application of LCO 3.0.4.b to an inoperable diesel generator. There is an increased risk associated with entering a MODE or other specified condition in the Applicability with an inoperable diesel generator and the provisions of LCO 3.0.4.b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
The OPERABILITY of the minimum specified A.C. and D.C. power sources and associated distribution systems during shutdown and refueling ensures that 1) the facility can be maintained in the shutdown or refueling condition for extended time periods and 2) sufficient instrumentation and control capability is available for monitoring and maintaining the unit status.
With the minimum required AC power sources not available, it is required to suspend CORE ALTERATIONS and operations involving positive reactivity additions that could result in loss of required SDM (Mode 5) or boron concentration (Mode 6). Suspending positive reactivity additions that could result in failure to meet minimum SDM or boron concentration limit is required to assure continued safe operation. Introduction of coolant inventory must be from sources that have a boron concentration greater than or equal to that required in the RCS for minimum SDM or refueling boron concentration.
This may result in an overall reduction in RCS boron concentration but provides acceptable margin to maintaining subcritical operation. Introduction of temperature changes including temperature increases when operating with a positive MTC must also be evaluated to ensure they do not result in a loss of required SDM.
The requirements of Specification 3.8.2.1 provide those actions to be taken for the inoperability of A.C. Distribution Systems. Action a of this specification provides an 8-hour action for the inoperability of one or more A.C. boards. Action b of this specification provides a relaxation of the 8-hour action to 24-hours provided the Vital Instrument Power Board is inoperable solely as a result of one inoperable inverter and the board has been energized within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. In this condition the requirements of Action a do not have to be applied. Action b is not intended to provide actions for inoperable inverters, which is December 21, 2012 SEQUOYAH - UNIT 1 B 3/4 8-5 Amendment No. 12, 137, 173, 205, 234, 241, 261,285, 301
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued) addressed by the operability requirements for the boards, and is included only for relief from the 8-hour action of Action a when only one inverter is affected. More than one inverter inoperable will result in the inoperability of the associated 120 Volt A.C. Vital Instrument Power Board(s) in accordance with Action a.
With more than one inverter inoperable entry into the actions of TS 3.0.3 is not applicable because Action a includes provisions for multiple inoperable inverters as attendant equipment to the boards.
The Surveillance Requirements for demonstrating the OPERABILITY of the diesel generators are in accordance with the recommendations of Regulatory Guides 1.9 "Selection of Diesel Generator Set Capacity for Standby Power Supplies," March 10, 1971, and 1.108 "Periodic Testing of Diesel Generator Units Used as Onsite Electric Power Systems at Nuclear Power Plants," Revision 1, August 1977, and 1.137 "Fuel-Oil Systems for Standby Diesel Generators," Revision 1, October 1979. The Surveillance Requirements for the diesel generator load-run test and the 24-hour endurance and margin test are in accordance with Regulatory Guide 1.9, Revision 3, July 1993, "Selection, Design, Qualification, and Testing of Emergency Diesel Generator Units Used as Class 1 E Onsite Electric Power Systems at Nuclear Power Plants." During the diesel generator endurance and margin surveillance test, momentary transients outside the kw and kvar load ranges do not invalidate the test results. Similarly, during the diesel generator load-run test, momentary transients outside the kw load range do not invalidate the test results.
Where the SRs discussed herein specify voltage and frequency tolerances, the following is applicable. 6800 volts is the minimum steady state output voltage and the 10 second transient value.
6800 volts is 98.6% of nominal bus voltage of 6900 volts and is based on the minimum voltage required for the diesel generator supply breaker to close on the 6.9 kV Shutdown Board. The specified maximum steady state output voltage of 7260 volts is based on the degraded over voltage relay setpoint and is equivalent to 110% of the nameplate rating of the 6600 volt motors. The specified minimum and maximum frequencies of the diesel generator are 58.8 Hz and 61.2 Hz, respectively. These values are equal to +/- 2% of the 60 Hz nominal frequency and are derived from the recommendations given in regulatory Guide 1.9.
Where the SRs discuss maximum transient voltages during load rejection testing, the following is applicable. The maximum transient voltage of 8880 volts represents a conservative limit to ensure the resulting voltage will not exceed a level that will cause component damage. It is based on the manufacturer's recommended high potential test voltage of 60% of the original factory high potential test voltage (14.8 kV). The diesel generator manufacturer has determined that the engine and/or generator controls would not experience detrimental effects for transient voltages < 9000 volts. The maximum transient voltage of 8276 volts is retained from the original technical specifications to ensure that the voltage transient following rejection of the single largest load is within the limits originally considered acceptable. It was based on 114% of 7260 volts, which is the Range B service voltage per ANSI-C84.1.
The Surveillance Requirement (SR) to transfer the power supply to each 6.9 kV Unit Board from the normal supply to the alternate supply demonstrates the OPERABILITY of the alternate supply to power the shutdown loads. The 18 month Frequency of the Surveillance is based on engineering judgment, taking into consideration the unit conditions required to perform the Surveillance, and is intended to be consistent with expected fuel cycle lengths. Operating experience has shown that these components usually pass the SR when performed at the 18 month Frequency. Therefore, the Frequency was concluded to be acceptable from a reliability standpoint. This SR is modified by two Notes. The reason for Note # is that, during operation with the reactor critical, performance of this SR for the Unit 1 Unit Boards could cause perturbations to the electrical distribution systems that could challenge continued steady state operation and, as a result, unit safety systems. Note ## specifies that transfer December 21, 2012 SEQUOYAH - UNIT 1 B 3/4 8-6 Amendment No. 12, 137,173, 205, 234, 261,285, 332
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued) capability is only required to be met for 6.9 kV Unit Boards that require normal and alternate power supplies. When both load groups are being supplied power by the USSTs, only the 6.9 kV Unit Boards associated with one load group are required to have normal and alternate power supplies. Therefore, only one CSST is required to be OPERABLE and available as an alternate power supply. Additionally, manual transfers between the normal supply and the alternate supply are not relied upon to meet the accident analysis. Manual transfer capability is verified to ensure the availability of a backup to the automatic transfer feature.
The Surveillance Requirement for demonstrating the OPERABILITY of the Station batteries are based on the recommendations of Regulatory Guide 1.129 "Maintenance Testing and Replacement of Large Lead Storage Batteries for Nuclear Power Plants," February 1978, and IEEE Std 450-1980, "IEEE Recommended Practice for Maintenance, Testing, and Replacement of Large Lead Storage batteries for Generating Stations and Substations."
Verifying average electrolyte temperature above the minimum for which the battery was sized, total battery terminal voltage onfloat charge, connection resistance values and the performance of battery service and discharge tests ensures the effectiveness of the charging system, the ability to handle high discharge rates and compares the battery capacity at that time with the rated capacity.
Table 4.8-2 specifies the normal limits for each designated pilot cell and each connected cell for electrolyte level, float voltage and specific gravity. The limits for the designated pilot cells float voltage and specific gravity, greater than 2.13 volts and.015 below the manufacturer's full charge specific gravity or a battery charger current that had stabilized at a low value, is characteristic of a charged cell with adequate capacity. The normal limits for each connected cell for float voltage and specific gravity, greater than 2.13 volts and not more than.020 below the manufacturer's full charge specific gravity with an average specific gravity of all the connected cells not more than.010 below the manufacture's full charge specific gravity, ensures the OPERABILITY and capability of the battery.
Operation with a battery cell's parameter outside the normal limit but within the allowable value specified in Table 4.8-2 is permitted for up to 7 days. During this 7 day period: (1) the allowable values for electrolyte level ensures no physical damage to the plates with an adequate electron transfer capability; (2) the allowable value for the average specific gravity of all the cells, not more than.020 below the manufacturer's recommended full charge specific gravity, ensures that the decrease in rating will be less than the safety margin provided in sizing; (3) the allowable value for an individual cell's specific gravity, ensures that an individual cell's specific gravity will not be more than.040 below the manufacturer's full charge specific gravity and that the overall capability of the battery will be maintained within an acceptable limit; and (4) the allowable value for an individual cell's float voltage, greater than 2.07 volts, ensures the battery's capability to perform its design function.
The tests listed below are a means of determining whether new fuel oil is of the appropriate grade and has not been contaminated with substances that would have an immediate, detrimental impact on diesel engine combustion. If the results from these tests are within acceptable limits, the fuel oil may be added to the storage tanks without concern for contaminating the entire volume of fuel oil in the storage tanks. These tests are to be conducted prior to adding the new fuel to the storage tank(s), but in no case is the time between receipt of new fuel and conducting the tests to exceed 31 days. The test, limits, and applicable ASTM Standards are as follows:
December 21, 2012 SEQUOYAH - UNIT 1 B 3/4 8-7 Amendment No. 12, 137, 173, 205, 234, 250, 261,332
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
- a.
Sample the new fuel in accordance with D4057-1988 (ref.);
- b.
Verify in accordance with the test specified in ASTM D975-1990 (Ref.) that the sample has an absolute specific gravity at 60/60 degrees F of __ 0.83 and _< 0.89 or an API gravity at 60 degrees F of
> 27 degrees and < 39 degrees, a kinematic viscosity at 40 degrees C of >_ 1.9 centistokes and < 4.1 centistokes, and a flash point of _> 125 degrees F; and
- c.
Verify that the new fuel oil has a clear and bright appearance with proper color when tested in accordance with ASTM D4176-1986 (Ref.).
Failure to meet any of the above limits is cause for rejecting the new fuel oil, but does not represent a failure to meet LCO concern since the fuel oil is not added to the storage tanks.
Within 31 days following the initial new fuel oil sample, the fuel oil is analyzed to establish that the other properties specified in Table 1 of ASTM D975-1990 (Ref.) are met, except that the analysis for sulfur may be performed in accordance with ASTM D1552-1990 (Ref.) or ASTM D2622-1987 (Ref.). The 31 day period is acceptable because the fuel oil properties of interest, even if they were not within stated limits, would not have an immediate effect on DIG operation. This surveillance ensures availability of high quality fuel oil for the D/Gs.
Fuel oil degradation during long-term storage shows up as an increase in particulate, due mostly to oxidation. The presence of particulate does not mean the fuel oil will not burn properly in a diesel engine.
The particulate can cause fouling of filters and fuel oil injection equipment, however, which can cause engine failure.
Particulate concentrations should be determined in accordance with ASTM D2276-94, Method A (Ref.). This method involves a gravimetric determination of total particulate concentration in the fuel oil and has a limit of 10 mg/l. It is acceptable to obtain a field sample for subsequent laboratory testing in lieu of field testing. Each of the four interconnected tanks which comprise a 7-day tank must be considered and tested separately.
The frequency of this test takes into consideration fuel oil degradation trends that indicate that particulate concentration is unlikely to change significantly between frequency intervals.
References:
ASTM Standards D4057-1988, "Practice for manual sampling of petroleum and petroleum Products."
D975-1990, "Standard Specifications for Diesel Fuel oils."
D4176-1986, "Free Water and Particulate Contamination in Distillate Fuels."
D1552-1990, "Standard Test Method for Sulfur in Petroleum Products (High Temperature Method)."
December 21, 2012 SEQUOYAH - UNIT 1 B 3/4 8-8 Amendment No.12, 137, 250, 261
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
D2622-1987, "Standard Test Method for Sulfur in Petroleum Products (X-Ray Spectrographic Method)."
D2276-1994, "Standard Test Method for Particulate Containment in Aviation Turbine Fuels."
D1298-1985, "Standard Test Method for Density, Specific Gravity, or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method."
3/4.8.3 ELECTRICAL EQUIPMENT PROTECTIVE DEVICES This specification is deleted.
December 21, 2012 Amendment No.12, 137, 250, 261 SEQUOYAH - UNIT 1 B 3/4 8-9
ATTACHMENT 3 SEQUOYAH NUCLEAR PLANT, UNIT 2 TECHNICAL SPECIFICATION BASES CHANGED PAGES TS Bases Affected Pages EPL Page 2 EPL Page 3 EPL Page 16 EPL Page 17 EPL Page 19 EPL Page 20 EPL Page 21 EPL Page 22 EPL Page 31 EPL Page 32 Index Page III Index Page XIV B 2-1 B 2-2 B 2-3 B 2-4 B 2-5 B 2-6 B 2-7 B 2-8 B 2-9 B 2-10 B 2-11 B 3/4 2-4 B 3/4 3-3a B 3/4 4-3a B 3/4 4-3b B 3/4 4-3c B 3/4 4-3d B 3/4 4-3e B 3/4 4-3f B 3/4 4-3g Removed B 3/4 4-3h through B 3/4 4-3k B 3/4 4-4f B 3/4 5-12 B 3/4 5-13 B 3/4 5-14 B 3/4 5-15 B 3/4 5-16 B 3/4 5-17 B 3/4 5-18 B 3/4 5-19 B 3/4 5-20 B 3/4 8-1 B 3/4 8-2 B 3/4 8-3 B 3/4 8-4 B 3/4 8-5 B 3/4 8-6 B 3/4 8-7 B 3/4 8-8 B 3/4 8-9
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paqe Revision Index Page VII 01/28/10 Index Page VIII 12/28/05 Index Page IX 12/28/05 Index Page X 12/28/05 Index Page XI 12/18/00
-Index Page XII 03/09/05 Index Page XIII 01/28/10 Index Page XIV 12/21/12 Index Page XV 12/18/00 Index Page XVI 08/02/06 Index Page XVII 05/24/02 1-1 05/18/88 1-2 04/13/09 1-3 02/29/00 1-4 05/22/07 1-5 05/22/07 1-6 08/02/06 1-7 09/15/04 1-8 09/15/04 1-9 05/18/88 1-10 05/18/88 2-1 09/26/12 2-2 09/26/12 2-3 (DELETED) 09/03/85 EPL-2 December 21, 2012
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paqe Revision 2-4 09/13/06 2-5 09/26/12 2-6 09/13/06 2-7 09/20/07 2-8 09/13/06 2-9 09/13/06 2-10 09/13/06 2-11 09/13/06 2-12 09/13/06 B(Note)
Original B2-1 10/10/12 B2-2 10/10/12 B2-3 10/10/12 B2-4 10/10/12 B2-5 10/10/12 B2-6 10/10/12 B2-7 10/10/12 B2-8 10/10/12 B2-9 10/10/12 B2-10 10/10/12 B2-11 10/10/12 3/4 0-1 10/04/06 3/4 0-2 10/04/06 3/4 0-3 10/04/06 3/4 0-4 10/04/06 3/4 1-1 11/26/93 3/4 1-2 Original 3/4 1-3 11/26/93 EPL-3 October 10, 2012
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paae Revision B3/4 0-4 02/05/03 B3/4 0-5 06/16/06 B3/4 0-6 06/16/06 B3/4 1-1 10/26/93 B3/4 1-2 12/18/00 B3/4 1-3 12/18/00 B3/4 1-3a 03/07/07 B3/4 1-4 04/21/97 B3/4 1-4a 11/21/95 B3/4 2-1 04/21/97 B3/4 2-2 04/21/97 B3/4 2-3 (Figure B3/4 2-1 DELETED) 09/29/83 B3/4 2-4 10/10/12 B3/4 3-1 09/13/06 B3/4 3-2 09/13/06 B3/4 3-2a 08/29/08 B3/4 3-3 12/28/05 B3/4 3-3a 03/05/13 B3/4 3-4 08/12/97 B3/4 3-5 through B3/4 3-9 09/14/06 B3/4 4-1 03/30/92 B3/4 4-2 06/16/06 B3/4 4-2a 05/25/00 B3/4 4-3 05/22/07 EPL-16 March 5, 2013
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Page Revision B3/4 4-3a 10/05/12 B3/4 4-3b 10/05/12 B3/4 4-3c 10/05/12 B3/4 4-3d 10/05/12 B3/4 4-3e 10/05/12 B3/4 4-3f 10/05/12 B3/4 4-3g 10/05/12 B3/4 4-3h (Deleted) 10/05/12 B3/4 4-3i (Deleted) 10/05/12 B3/4 4-3j (Deleted) 10/05/12 B3/4 4-3k (Deleted) 10/05/12 B3/4 4-4 12/04/08 B3/4 4-4a 12/04/08 B3/4 4-4b 04/11/05 B3/4 4-4c 12/04/08 B3/4 4-4d 12/04/08 B3/4 4-4e 05/22/07 B3/4 4-4f 10/05/12 B3/4 4-4g 05/22/07 B3/4 4-4h 05/22/07 B3/4 4-4i 05/22/07 B3/4 4-4j 05/22/07 B3/4 4-4k 08/04/00 B3/4 4-41 08/04/00 EPL-17 October 5, 2012
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Pa_qe Revision B3/4 5-1 03/25/10 83/4 5-2 03/25/10 B3/4 5-3 03/25/10 83/4 5-4 03/25/10 B3/4 5-5 03/25/10 B3/4 5-6 03/25/10 B3/4 5-7 03/25/10 B3/4 5-8 through B3/4 5-11 03/25/10 B3/4 5-12 through B3/4 5-20 03/24/12 B3/4 6-1 through 83/4 6-2 04/13/09 B3/4 6-3 05/27/10 B3/4 6-4 through B3/4 6-6 04/13/09 B3/4 6-7 through B3/4 6-12 04/13/09 B3/4 6-13 through B3/4 6-18 04/13/09 B3/4 6-19 through B3/4 6-20 04/13/09 83/4 6-21 04/13/09 83/4 7-1 04/30/02 83/4 7-2 08/14/01 B3/4 7-2a 11/17/95 B3/4 7-2b 04/11/05 83/4 7-3 06/12/09 EPL-1 9 March 24, 2012
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Page Revision B3/4 7-3a 06/08/98 B3/4 7-4 09/28/07 B3/4 7-4a 09/28/07 B3/4 7-4b 09/28/07 B3/4 7-4c thru B3/4 7-4m 10/28/08 B3/4 7-5 08/18/05 B3/4 7-6 (DELETED) 08/28/98 B3/4 7-6a 12/28/05 B3/4 7-7 through B3/4 7-8 (DELETED) 08/12/97 B3/4 7-9 12/19/00 B3/4 7-10 12/19/00 B3/4 7-11 12/19/00 B3/4 7-12 12/19/00 B3/4 7-13 12/19/00 B3/4 7-14 12/19/00 B3/4 7-15 12/19/00 B3/4 7-16 01/31/05 B3/4 7-17 02/27/02 B3/4 7-18 02/27/02 B3/4 8-1 12/21/12 B3/4 8-2 12/21/12 B3/4 8-3 12/21/12 B3/4 8-4 12/21/12 B3/4 8-5 12/21/12 B3/4 8-6 12/21/12 B3/4 8-7 12/21/12 B3/4 8-8 12/21/12 B3/4 8-9 12/21/12 EPL-20 December 21, 2012
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paqe Revision B3/4 9-1 09/20/04 B3/4 9-2 12/28/05 B3/4 9-3 04/19/04 B3/4 10-1 09/20/04 B3/4 11-1 12/09/93 B3/4 11-2 11/16/90 83/4 12-1 11/16/90 5-1 08/02/06 5-2 08/02/06 5-3 08/02/06 5-4 08/02/06 5-5 12/19/00 5-5a 12/19/00 5-5b 08/02/06 5-5c 12/19/00 5-5d 12/19/00 5-5e 12/19/00 5-5f 12/19/00 5-5g 12/19/00 5-5h 12/19/00 5-5i 12/19/00 5-5j 12/19/00 5-6 08/02/06 EPL-21 December 21, 2012
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS EFFECTIVE PAGE LISTING Paqe Revision 6-1 02/16/01 6-2 02/02/10 6-3 through 6-4 (DELETED) 02/16/01 6-5 02/11/03 6-6 05/24/02 6-7 02/11/03 6-8 02/11/03 6-9 04/13/09 6-10 04/13/09 6-10a 07/10/12 6-1Ob 07/10/12 6-1 Oc (Deleted) 07/10/12 6-10d (Deleted) 07/10/12
.6-11 04/13/09 6-12 08/02/93 6-13 09/26/12 6-14 09/26/12 6-14a 09/26/12 6-15 07/10/12 6-16 02/11/03 6-16a 02/11/03 6-16b 02/11/03 6-17 07/01/98 6-18 02/11/03 6-19 10/28/08 6-20 10/28/08 EPL-22 September 26, 2012
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Amendment 288 Issued by NRC Amendment 289 Issued by NRC Amendment 290 Issued by NRC Amendment 291 Issued by NRC Amendment 292 Issued by NRC Amendment 293 Issued by NRC Amendment 294 Issued by NRC Bases Revision Amendment 295 Issued by NRC Amendment 296 Issued by NRC Amendment 297 Issued by NRC Amendment 298 Issued by NRC Amendment 299 Issued by NRC Amendment 300 Issued by NRC Amendment 301 Issued by NRC Amendment 302 Issued by NRC Amendment 303 Issued by NRC Amendment 304 Issued by NRC License Condition Issued by NRC Bases Revision Amendment 305 Issued by NRC EPL Revised License Condition Issued by NRC Amendment 306 Issued by NRC Amendment 307 Issued by NRC Amendment 308 Issued by NRC Bases Revision Amendment 309 Issued by NRC Amendment 310 Issued by NRC Amendment 311 Issued by NRC Amendment 312 Issued by NRC Bases Revision Bases Revision Amendment 313 Issued by NRC Amendment 314 Issued by NRC Amendment 315 Issued by NRC Amendment 316 Issued by NRC Bases Revision Amendment 317 Issued by NRC Amendment 318 Issued by NRC Bases Revision Amendment 319 Issued by NRC Amendment 320 Issued by NRC Bases Revision Bases Revision Amendment 321 Issued by NRC Bases Revision Amendment 323 Issued by NRC Bases Revision Amendment 324 Issued by NRC Bases Revision Date and Revision 03/09/05 (R288) 04/05/05 (R289) 04/11/05 (R290) 05/03/05 (R291) 05/24/05 (R292) 08/18/05 (R293) 09/02/05 (R294) 09/11/03 (BR-28) 12/28/05 (R295) 04/06/06 (R296) 06/16/06 (R297) 08/02/06 (R298) 09/13/06 (R299) 09/14/06 (R300) 10/04/06 (R301) 11/07/06 (R302) 11/16/06 (R303) 12/11/06 (R304) 02/08/07 03/07/07 (BR-29) 05/22/07 (R305) 05/22/07 08/09/07 (B.5.b) 09/20/07 (R306) 09/28/07 (R307) 10/11/07 (R308) 12/12/07 (BR-30) 03/24/08 (R309) 04/02/08 (R310) 04/04/08 (R31 1) 08/29/08 (R312) 08/29/08 (BR-31) 08/28/08 (BR-32) 10/28/08 12/04/08 04/13/09 06/12/09 06/12/09 (BR-33) 08/14/09 10/19/09 10/19/09 (BR-34) 01/28/10 02/02/10 03/25/10 (BR-35) 05/27/10 (BR-36) 12/21/10 03/24/12 (BR-38) 07/10/12 10/05/12 (BR-40) 09/26/12 10/10/12 (BR-39)
EPL-31 October 10, 2012
SEQUOYAH NUCLEAR PLANT UNIT 2 TECHNICAL SPECIFICATIONS AMENDMENT LISTING Amendments Amendment 325 Issued by NRC Bases Revision Bases Revision Date and Revision 10/31/12 12/21/12 (BR-41) 03/05/13 (BR-42)
EPL-32 March 5, 2013
INDEX SAFETY LIMITS AND LIMITING SAFETY SYSTEM SETTINGS SECTION PAGE 2.1 SAFETY LIMITS R e a c to r C o re...................................................................................................................................
2 -1 R eactor C oolant S ystem Pressure.................................................................................................
2-1 2.2 LIMITING SAFETY SYSTEM SETTINGS Reactor Trip System Instrumentation Setpoints.............................................................................
2-4 BASES SECTION PAGE 2.1 SAFETY LIMITS R e a c to r C o re..............................................................................................................................
B 2 -1 Reactor Coolant System Pressure.............................................................................................
B 2-2 2.2 LIMITING SAFETY SYSTEM SETTINGS Reactor Trip System Instrum entation Setpoints........................................................................
B 2-3 SEQUOYAH - UNIT 2 III October 10, 2012 Amendment No. 324
INDEX BASES SECTION PAGE 3/4.7.4 ESSENTIAL RAW COOLING WATER SYSTEM.............................................................
B 3/4 7-3a 3/4.7.5 U LT IM A T E H EA T S IN K......................................................................................................
B 3/4 7-4 3/4.7.6 FLO O D P R O T EC T IO N.......................................................................................................
B 3/4 7-4 3/4.7.7 CONTROL ROOM EMERGENCY VENTILATION SYSTEM.............................................
B 3/4 7-4 3/4.7.8 AUXILIARY BUILDING GAS TREATMENT SYSTEM.......................................................
B 3/4 7-5 3/4.7.9 S N U B B E R S........................................................................................................................
B 3/4 7 -5 3/4.7.10 SEALED SOURCE CONTAMINATION (DELETED)........................................................
B 3/4 7-6a 3/4.7.11 FIRE SUPPRESSION SYSTEMS (DELETED)..................................................................
B 3/4 7-7 3/4.7.12 FIRE BARRIER PENETRATIONS (DELETED).................................................................
B 3/4 7-8 3/4.7.13 SPENT FUEL POOL MINIMUM BORON CONCENTRATION..........................................
B 3/4 7-9 3/4.7.14 CASK PIT POOL MINIMUM BORON CONCENTRATION..............................................
B 3/4 7-13 3/4.7.15 CONTROL ROOM AIR-CONDITIONING SYSTEM (CRACS).........................................
B 3/4 7-16 3/4.8 ELECTRICAL POWER SYSTEMS 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION S Y S T E M S...........................................................................................................................
B 3 /4 8 -1 3/4.8.3 ELECTRICAL EQUIPMENT PROTECTIVE DEVICES (DELETED)..................................
B 3/4 8-9 3/4.9 REFUELING OPERATIONS 3/4.9.1 BO RO N C O NC ENTRATIO N..............................................................................................
B 3/4 9-1 3/4.9.2 IN ST R U M E N TA T IO N.........................................................................................................
B 3/4 9-1 3/4.9.3 D E C A Y T IM E......................................................................................................................
B 3/4 9-1 3/4.9.4 CONTAINMENT BUILDING PENETRATIONS..................................................................
B 3/4 9-1 3/4.9.5 CO M M UN ICATIO NS (Deleted)..........................................................................................
B 3/4 9-2 3/4.9.6 M ANIPULATO R C RANE (Deleted)....................................................................................
B 3/4 9-2 3/4.9.7 CRANE TRAVEL - SPENT FUEL PIT AREA (DELETED).................................................
B 3/4 9-2 3/4.9.8 RESIDUAL HEAT REMOVAL AND COOLANT CIRCULATION........................................
B 3/4 9-2 3/4.9.9 CONTAINMENT VENTILATION SYSTEM.........................................................................
B 3/4 9-3 December 21, 2012 SEQUOYAH - UNIT 2 XIV Amendment No. 194, 218, 225, 256, 262, 295,325
2.1 SAFETY LIMITS BASES 2.1.1 REACTOR CORE The restrictions of this Safety Limit prevent overheating of the fuel cladding (due to departure from nucleate boiling) and overheating of the fuel pellet (centerline fuel melt), either of which could result in cladding perforation that would result in the release of fission products to the reactor coolant.
Overheating of the fuel cladding is prevented by restricting fuel operation to within the nucleate boiling regime where the heat transfer coefficient is large and the cladding surface temperature is slightly above the coolant saturation temperature. Overheating of the fuel is prevented by maintaining the steady state peak linear heat rate (LHR) below the level at which fuel centerline melting occurs.
Operation above the upper boundary of the nucleate boiling regime could result in excessive temperatures because of the onset of departure from nucleate boiling (DNB) and the corresponding significant reduction in heat transfer coefficient from the outer surface of the cladding to the reactor coolant water. Inside the steam film, high cladding temperatures are reached, and a cladding water (zirconium water) reaction may take place. This chemical reaction results in oxidation of the fuel cladding to a structurally weaker form. This weaker form may lose its integrity, resulting in an uncontrolled release of activity to the reactor coolant. DNB is not a directly measurable parameter during operation and; therefore, THERMAL POWER and Reactor Coolant Temperature and Pressure have been related to DNB. The DNB correlations have been developed to predict the DNB flux and the location of DNB for axially uniform and non-uniform heat flux distributions. The local DNB heat flux ratio, DNBR, defined as the ratio of the heat flux that would cause DNB at a particular core location to the local heat flux, is indicative of the margin to DNB.
The DNB design basis is that there must be at least a 95 percent probability with 95 percent confidence that DNB will not occur when the minimum DNBR is at the design DNBR limit.
To meet the DNB Design Basis, a statistical core design (SCD) process has been used to develop an appropriate statistical DNBR design limit. Uncertainties in plant operating parameters, nuclear and thermal parameters, and fuel fabrication parameters are considered statistically such that there is at least a 95 percent probability at a 95 percent confidence level that the minimum DNBR for the limiting rod is greater than or equal to the DNBR limit. This DNBR uncertainty derived from the SCD analysis, combined with the applicable DNB critical heat flux correlation limit, establishes the statistical DNBR design limit which must be met in plant safety analysis using values of input parameters without adjustment for uncertainty.
The curves of Figure 2.1-1 show the loci of points of THERMAL POWER, Reactor Coolant System pressure and average temperature for which the minimum DNBR is no less than the safety analysis DNBR limit, or the average enthalpy at the vessel exit is equal to the enthalpy of saturated liquid.
These lines are bounding for all fuel types. The curves in Figure 2.1-1 are based upon enthalpy rise hot channel factors that result in acceptable DNBR performance of each fuel type. Acceptable DNBR performance is assured by operation within the DNB-based Limiting Safety Limit System Settings (RPS trip limits). The plant trip setpoints are verified to be less than the limits defined by the safety limit lines in Figure 2.1-1 converted from power to delta-temperature and adjusted for uncertainty.
October 10, 2012 SEQUOYAH - UNIT 2 B 2-1 Amendment No. 21, 104,130, 146, 214, 324
2.1 SAFETY LIMITS BASES Operation above the maximum local linear heat generation rate for fuel melting could result in excessive fuel pellet temperature and cause melting of the fuel at its centerline. Fuel centerline melting occurs when the local LHR, or power peaking, in a region of the fuel is high enough to cause the fuel centerline temperature to reach the melting point of the fuel. Expansion of the pellet upon centerline melting may cause the pellet to stress the cladding to the point of failure, allowing an uncontrolled release of activity to the reactor coolant. The melting point of uranium dioxide varies slightly with burnup. As uranium is depleted and fission products produced, the net effect is a decrease in the melting point. Fuel centerline temperature is not a directly measurable parameter during operation. The maximum local fuel pin centerline temperature is maintained by limiting the local linear heat generation rate in the fuel. The local linear heat generation rate in the fuel is limited so that the maximum fuel centerline temperature will not exceed the acceptance criteria in the safety analysis.
The limiting heat flux conditions for DNB are higher than those calculated for the range of all control rods fully withdrawn to the maximum allowable control rod insertion assuming the axial power imbalance, or Delta-I (Al), is within the limits of the f, (Al) function of the Overtemperature Delta-Temperature trip. When the axial power imbalance exceeds the tolerance (or deadband) of the f, (AI) trip reset function, the Overtemperature Delta-Temperature trip setpoint is reduced by the values in the CORE OPERATING LIMITS REPORT to provide protection required by the core safety limits.
Similarly, the limiting linear heat generation rate conditions for centerline fuel melt are higher than those calculated for the range of all control rods from the fully withdrawn to the maximum allowable control rod insertion assuming the axial power imbalance, or Delta-I (Al), is within the limits of the f2 (Al) function of the Overpower Delta-Temperature trip. When the axial power imbalance exceeds the tolerance (or deadband) of the f2 (AI) trip resent function, the Overpower Delta-Temperature trip setpoint is reduced by the values specified in the CORE OPERATING LIMITS REPORT to provide protection required by the core safety limits.
2.1.2 REACTOR COOLANT SYSTEM PRESSURE The restriction of this Safety Limit protects the integrity of the Reactor Coolant System from overpressurization and thereby prevents the release of radionuclides contained in the reactor coolant from reaching the containment atmosphere.
The reactor pressure vessel and pressurizer are designed to Section III of the ASME Code for Nuclear Power Plant which permits a maximum transient pressure of 110% (2735 psig) of design pressure. The Reactor Coolant System piping, valves and fittings, are designed to ANSI B 31.1 1967 Edition, which permits a maximum transient pressure of 120% (2985 psig) of component design pressure.
The Safety Limit of 2735 psig is therefore consistent with the design criteria and associated code requirements.,
The entire Reactor Coolant System is hydrotested at 3107 psig, 125% of design pressure, to demonstrate integrity prior to initial operation.
October 10, 2012 SEQUOYAH - UNIT 2 B 2-2 Amendment No. 324
SAFETY LIMITS BASES 2.2.1 REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS The Reactor Nominal Trip Setpoint Limits specified in Table 2.2-1 are the values at which the Reactor Trips are set for each functional unit. The Nominal Trip Setpoints have been selected to ensure that the reactor core and reactor coolant system are prevented from exceeding their safety limits during normal operation and design basis anticipated operational occurrences and to assist the Engineered Safety Features Actuation System in mitigating the consequences of accidents. Operation with a trip set less conservative than its Nominal Trip Setpoint but within its specified Allowable Value is acceptable on the basis that the difference between each Nominal Trip Setpoint and the Allowable Value is equal to or less than the rack allowance assumed for each trip in the safety analyses.
Technical specifications are required by 10 CFR 50.36 to contain Limiting Safety System Settings (LSSS) defined by the regulation as "... settings for automatic protective devices... so chosen that automatic protective action will correct the abnormal situation before a Safety Limit (SL) is exceeded."
The analytic limit is the limit of the process variable at which a safety action is initiated, as established by the safety analysis, to ensure that a SL is not exceeded. Any automatic protection action that occurs on reaching the analytic limit therefore ensures that the SL is not exceeded. However, in practice, the actual settings for automatic protective devices must be chosen to be more conservative than the analytic limit to account for instrument loop uncertainties related to the setting at which the automatic protective action would actually occur.
The Nominal Trip Setpoint is a predetermined setting for a protective device chosen to ensure automatic actuation prior to the process variable reaching the analytic limit and thus ensuring that the SL would not be exceeded. As such, the Nominal Trip Setpoint accounts for uncertainties in setting the device (e.g., calibration), uncertainties in how the device might actually perform (e.g., repeatability),
changes in the point of action of the device over time (e.g., drift during surveillance intervals), and any other factors which may influence its actual performance (e.g., harsh accident environments). In this manner, the Nominal Trip Setpoint plays an important role in ensuring that SLs are not exceeded. As such, the Nominal Trip Setpoint meets the definition of an LSSS in accordance with Regulatory Guide 1.105, Revision 3, "Setpoints for Safety-Related Instrumentation," and could be used to meet the requirements that they be contained in the technical specifications.
October 10, 2012 SEQUOYAH - UNIT 2 B 2-3 Amendment No. 130, 146, 299, 324
SAFETY LIMITS BASES 2.2.1 REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued)
Technical specifications contain values related to the OPERABILITY of equipment required for safe operation of the facility. OPERABLE is defined in the technical specifications as "... being capable of performing its safety function(s)." For automatic protective devices, the required safety function is to ensure that a SL is not exceeded and therefore the LSSS as defined by 10 CFR 50.36 is the same as the OPERABILITY limit for these devices. However, use of the Nominal Trip Setpoint to define OPERABILITY in technical specifications and its corresponding designation as the LSSS required by 10 CFR 50.36 would be an overly restrictive requirement if it were applied as an OPERABILITY limit for the "as found" value of a protective device setting during a surveillance. This would result in technical specification compliance problems, as well as reports and corrective actions required by the rule which are not necessary to ensure safety. For example, an automatic protective device with a setting that has been found to be different from the Nominal Trip Setpoint due to some drift of the setting may still be OPERABLE since drift is to be expected. This expected drift would have been specifically accounted for in the setpoint methodology for calculating the Nominal Trip Setpoint and thus the automatic protective action would still have ensured that the SL would not be exceeded with the "as found" setting of the protective device. Therefore, the device would still be OPERABLE since it would have performed its safety function and the only corrective action required would be to reset the device to the Nominal Trip Setpoint to account for further drift during the next surveillance interval.
Use of the Nominal Trip Setpoint to define "as found" OPERABILITY and its designation as the LSSS under the expected circumstances described above would result in actions required by both the rule and technical specifications that are clearly not warranted. However, there is also some point beyond which the device would have not been able to perform its function due, for example, to greater than expected drift. This value needs. to be specified in the technical specifications in order to define OPERABILITY of the devices and is designated as the Allowable Value, which as stated above, is the same as the LSSS.
The Allowable Value specified in Table 2.2-1 serves as the LSSS such that a channel is OPERABLE if the trip setpoint is found not to exceed the Allowable Value during the CHANNEL FUNCTIONAL TEST (CFT). As such, the Allowable Value differs from the Nominal Trip Setpoint by an amount primarily equal to the expected instrument loop uncertainties, such as drift, during the surveillance interval. In this manner, the actual setting of the device will still meet the LSSS definition and ensure that a Safety Limit is not exceeded at any given point of time as long as the device has not drifted beyond that expected during the surveillance interval. Note that, although the channel is "OPERABLE" under these circumstances, the trip setpoint should be left adjusted to a value within the established trip setpoint calibration tolerance band, in accordance with uncertainty assumptions stated in the setpoint methodology (as-left criteria), and confirmed to be operating within the statistical allowances of the uncertainty terms assigned. If the actual setting of the device is found to have exceeded the Allowable Value, the device would be considered inoperable from a technical specification perspective. This requires corrective action including those actions required by 10 CFR 50.36 when automatic protective devices do not function as required.
A channel is OPERABLE with a trip setpoint value outside its calibration tolerance band provided the trip setpoint "as-found" value does not exceed its associated Allowable Value and provided the trip setpoint "as-left" value is adjusted to a value within the "as-left" calibration tolerance band of the Nominal Trip Setpoint. A trip setpoint may be set more conservative than the Nominal Trip Setpoint as necessary in response to plant conditions. The conservative direction is established by the direction of the inequality applied to the Allowable Value.
A detailed description of the methodology used to calculate the Allowable Value and trip setpoints, including their explicit uncertainties, is provided in the Westinghouse Electric Company setpoint methodology study which incorporates all of the known uncertainties applicable to each channel. The magnitudes of these uncertainties are factored into the determination of each trip setpoint and October 10, 2012 SEQUOYAH - UNIT 2 B 2-4 Amendment No. 299
SAFETY LIMITS BASES 2.2.1 REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued) corresponding Allowable Value. The trip setpoint entered into the channel is more conservative than that specified by the Allowable Value (LSSS) to account for measurement errors detectable by the CFT. The Allowable Value serves as the Technical Specification OPERABILITY limit for the purpose of the CFT.
One example of such a change in measurement error is drift during the surveillance interval. If the measured setpoint does not exceed the Allowable Value, the channel is considered OPERABLE.
The trip setpoint is the value at which the channels are set and is the expected value to be achieved during calibration. The trip setpoint value ensures the LSSS and safety analysis limits are met for the surveillance interval selected when a channel is adjusted based on the stated channel uncertainties. Any channel is considered to be properly adjusted when the "as-left" setpoint value is within the band for CHANNEL CALIBRATION uncertainty allowance (i.e. +/- rack calibration + comparator setting uncertainties). The trip setpoint value is therefore, considered a "nominal" value (i.e., expressed as a value without inequalities) for the purposes of the CFT and CHANNEL CALIBRATION.
October 10, 2012 SEQUOYAH - UNIT 2 B 2-5 Amendment No. 299
2.2 LIMITING SAFETY SYSTEM SETTINGS BASES Manual Reactor Trip The Manual Reactor Trip is a redundant channel to the automatic protective instrumentation channels and provides a manual reactor trip capability.
Power Range, Neutron Flux The Power Range, Neutron Flux channel high setpoint provides reactor core protection against reactivity excursions which are too rapid to be protected by temperature and pressure protective circuitry.
The low set point provides redundant protection in the power range for a power excursion beginning from low power. The trip associated with the low setpoint may be manually bypassed when P-10 is active (two of the four power range channels indicate a power level of above approximately 10 percent of RATED THERMAL POWER) and is automatically reinstated when P-10 becomes inactive (three of the four channels indicate a power level below approximately 9 percent of RATED THERMAL POWER).
Power Range, Neutron Flux, High Rates The Power Range Positive Rate trip provides protection against rapid flux increases which are characteristic of rod ejection events from any power level. Specifically, this trip complements the Power Range Neutron Flux High and Low trips to ensure that the criteria are met for rod ejection from partial power.
The Power Range Negative Rate trip provides protection to ensure that the minimum DNBR is maintained above the safety analysis DNBR limit for control rod drop accidents. At high power a single or multiple rod drop accident could cause local flux peaking which, when in conjunction with nuclear power being maintained equivalent to turbine power by action of the automatic rod control system, could cause an unconservative local DNBR to exist. The Power Range Negative Rate trip will prevent this from occurring by tripping the reactor for all single dropped rods with a reactivity insertion of greater than 500 pcm or multiple dropped rods.
Intermediate and Source Range, Nuclear Flux The Intermediate and Source Range, Nuclear Flux trips provide reactor core protection during reactor startup. These trips provide redundant protection to the low setpoint trip of the Power Range, Neutron Flux channels. The Source Range Channels will initiate a reactor trip at about 10÷5 counts per second unless manually blocked when P-6 becomes active. The Intermediate October 10, 2012 SEQUOYAH - UNIT 2 B 2-6 Amendment No. 129, 130
LIMITING SAFETY SYSTEM SETTINGS BASES Intermediate and Source Range, Nuclear Flux (Continued)
Range Channels will initiate a reactor trip at approximately 25 percent of RATED THERMAL POWER unless manually blocked when P-10 becomes active. No credit was taken for operation of the trips associated with either the Intermediate or Source Range Channels in the accident analyses; however, their functional capability at the specified trip settings is required by this specification to enhance the overall reliability of the Reactor Protection System.
Overtemperature AT The Overtemperature Delta T trip provides core protection to prevent DNB for all combinations of pressure, power, coolant temperature, and axial power distribution, provided that the transient is slow with respect to transit, thermowell, and RTD response time delays from the core to the temperature detectors (about 8 seconds), and pressure is within the range between the High and Low Pressure reactor trips.
This setpoint includes corrections for axial power distribution, changes in density and heat capacity of water with temperature and dynamic compensation for transport, thermowell, and RTD response time delays from the core to the RTD output indication. With normal axial power distribution, this reactor trip limit is always below the core safety limit as shown in Figure 2.1-1. If axial peaks are greater than design, as indicated by the difference between top and bottom power range nuclear detectors, the reactor trip is automatically reduced according to the notations in Table 2.2-1.
The f1(AI) trip reset term in the Overtemperature Delta T trip function precludes power distributions that cause the DNB limit to be exceeded during a limiting Condition II event. The negative and positive Al limits at which the f1(AI) term begins to reduce the trip setpoint and the dependence of f1(AI) on THERMAL POWER are determined on a cycle-specific basis using approved methodology and are specified in the COLR per Specification 6.9.1.14.
Operation with a reactor coolant loop out of service below the 4 loop P-8 setpoint does not require reactor protection system setpoint modification because the P-8 setpoint and associated trip will prevent DNB during 3 loop operation exclusive of the Overtemperature Delta T setpoint.
Delta-To, used in the Overtemperature and Overpower AT trips, represents the 100 percent RTP value as measured by the plant for each loop. This normalizes each loop's AT trips to the actual operating conditions existing at the time of measurement, thus forcing the trip to reflect the equivalent full power conditions as assumed in the accident analyses. These differences in RCS loop AT can be due to several factors, e.g., measured RCS loop flows greater than thermal design flow, and slightly asymmetric power distributions between quadrants. While RCS loop flows are not expected to change with cycle life, radial power redistribution between quadrants may occur, resulting in small changes in loop specific AT values. Accurate determination of the loop specific AT value should be made quarterly and under steady state conditions (i.e., power distributions not affected by xenon or other transient conditions.).
October 10, 2012 SEQUOYAH - UNIT 2 B 2-7 Amendment No. 129, 132, 214
LIMITING SAFETY SYSTEM SETTINGS BASES Overpower AT The Overpower Delta T reactor trip provides assurance of fuel integrity, e.g., no melting, under all possible overpower conditions, limits the required range for Overtemperature Delta T protection, and provides a backup to the High Neutron Flux trip. The setpoint includes corrections for changes in axial power distribution, density and heat capacity of water with temperature, and dynamic compensation for transport, thermowell, and RTD response time delays from the core to the RTD output indication. The setpoint is automatically reduced according to the notations in Table 2.2-1 to account for adverse axial flux differences.
The f2(AI) trip reset term in the Overpower Delta T trip function precludes power distributions that cause the fuel melt limit to be exceeded during a limiting Condition II event. The negative and positive Al limits at which the f2(AI) term begins to reduce the trip setpoint and the dependence of f2(AI) on THERMAL POWER are determined on a cycle-specific basis using approved methodology and are specified in the COLR per Specification 6.9.1.14.
The Overpower Delta T trip provides protection to mitigate the consequences of various size steam breaks as reported in WCAP-9226, "Reactor Core Response to Excessive Secondary Steam Releases."
Delta-To, as used in the Overtemperature and Overpower AT trips, represents the 100 percent RTP value as measured by the plant for each loop. This normalizes each loop's AT trips to the actual operating conditions existing at the time of measurement, thus forcing the trip to reflect the equivalent full power conditions as assumed in the accident analyses. These differences in RCS loop AT can be due to several factors, e.g., measured RCS loop flows greater than thermal design flow, and slightly asymmetric power distributions between quadrants. While RCS loop flows are not expected to change with cycle life, radial power redistribution between quadrants may occur, resulting in small changes in loop specific AT values. Accurate determination of the loop specific AT value should be made quarterly and under steady state conditions (i.e., power distributions not affected by xenon or other transient conditions.).
Pressurizer Pressure The Pressurizer High and Low Pressure trips are provided to limit the pressure range in which reactor operation is permitted. The High Pressure trip is backed up by the pressurizer code safety valves for RCS overpressure protection, and is therefore set lower than the set pressure for these valves (2485 psig). The Low Pressure trip provides protection by tripping the reactor in the event of a loss of reactor coolant pressure.
Pressurizer Water Level The Pressurizer High Water Level trip ensures protection against Reactor Coolant System overpressurization by limiting the water level to a volume sufficient to retain a steam bubble and prevent water relief through the pressurizer safety valves. No credit was taken for operation of this trip in the accident analyses; however, its functional capability at the specified trip setting is required by this specification to enhance the overall reliability of the Reactor Protection System.
October 10, 2012 SEQUOYAH-UNIT 2 B 2-8 Amendment No. 132, 214
LIMITING SAFETY SYSTEM SETTINGS BASES Loss of Flow The Loss of Flow trips provide core protection to prevent DNB in the event of a loss of one or more reactor coolant pumps.
Above 11 percent of RATED THERMAL POWER, an automatic reactor trip will occur if the flow in any two loops drops below 90 percent of nominal full loop flow. Above the P-8 interlock, automatic reactor trip will occur if the flow in any single loop drops below 90 percent of nominal full loop flow. This latter trip will prevent the minimum value of the DNBR from going below 1.30 during normal operational transients and anticipated transients when 3 loops are in operation and the Overtemperature Delta T trip setpoint is adjusted to the value specified for all loops in operation.
Steam Generator Water Level The Steam Generator Water Level Low-Low trip protects the reactor from loss of heat sink in the event of a sustained steam/feedwater flow mismatch resulting from loss of normal feedwater or a feedwater system pipe break, outside of containment. This function also provides input to the steam generator level control system. IEEE 279 requirements are satisfied by 2/3 logic for protection function actuation, thus allowing for a single failure of a channel and still performing the protection function. Control/protection interaction is addressed by the use of the Median Signal Selector which prevents a single failure of a channel providing input to the control system requiring protection function action. That is, a single failure of a channel providing input to the control system does not result in the control system initiating a condition requiring protection function action. The Median Signal Selector performs this by not selecting the channels indicating the highest or lowest steam generator levels as input to the control system.
With the transmitters located inside containment and thus possibly experiencing adverse environmental conditions (due to a feedline break), the Environmental Allowance Modifier (EAM) was devised. The EAM function (Containment Pressure (EAM) with a setpoint of _< 0.5 psig) senses the presence of adverse containment conditions (elevated pressure) and enables the Steam Generator Water Level -
Low-Low trip setpoint (Adverse) which reflects the increased transmitter uncertainties due to this environment. The EAM allows the use of a lower Steam Generator Water Level - Low-Low (EAM) trip setpoint when these conditions are not present, thus allowing more margin to trip for normal operating conditions.
The Trip Time Delay (TTD) creates additional operational margin when the plant needs it most, during early escalation to power, by allowing the operator time to recover level when the primary side load is sufficiently small to allow such action. The TTD is based on continuous monitoring of primary side power through the use of RCS loop AT. Two time delays are calculated, based on the number of steam generators indicating less than the Low-Low Level trip setpoint and the primary side power level. The magnitude of the delays decreases with increasing October 10, 2012 SEQUOYAH - UNIT 2 B 2-9 Amendment Nos. 130, 132
LIMITING SAFETY SYSTEM SETTINGS BASES Steam Generator Water Level (Cont'd) primary side power level, up to 50 percent RTP. Above 50 percent RTP there are no time delays for the Low-Low level trips.
In the event of failure of a Steam Generator Water Level channel, it is placed in the trip condition as input to the Solid State Protection System and does not affect either the EAM or TTD setpoint calculations for the remaining operable channels. It is then necessary for the operator to force the use of the shorter TTD time delay by adjustment of the single steam generator time delay calculation (Ts) to match the multiple steam generator time delay calculation (TM) for the affected protection set, through the MMI. Failure of the Containment Pressure (EAM) channel to a protection set also does not affect the EAM setpoint calculations. This results in the requirement that the operator adjust the affected Steam Generator Water Level - Low-Low (EAM) trip setpoints to the same value as the Steam Generator Water Level - Low-Low (Adverse). Failure of the RCS loop AT channel input (failure of more than one TH RTD or failure of a Tc RTD) does not affect the TTD calculation for a protection set. This results in the requirement that the operator adjust the threshold power level for zero seconds time delay from 50 percent RTP to 0 percent RTP, through the MMI.
The High Containment Pressure ESF trip that generates a safety injection signal and subsequent reactor trip protects the reactor from loss of heat sink in the event of a sustained steam/feedwater flow mismatch resulting from a feedwater system pipe break inside of containment. IEEE 279 requirements are satisfied by 2/3 logic for protection function actuation, thus allowing for a single failure of a channel and still performing the protection function.
Undervoltape and Underfrequency - Reactor Coolant Pump Busses The Undervoltage and Underfrequency Reactor Coolant Pump bus trips provide reactor core protection against DNB as a result of loss of voltage or underfrequency to more than one reactor coolant pump. The specified setpoints assure a reactor trip signal is generated before the low flow trip setpoint is reached.
Time delays are incorporated in the underfrequency and undervoltage trips to prevent spurious reactor trips from momentary electrical power transients. For undervoltage, the delay is set so that the time required for a signal to reach the reactor trip breakers following the simultaneous trip of two or more reactor coolant pump bus circuit breakers shall not exceed 1.2 seconds. For underfrequency, the delay is set so that the time required for a signal to reach the reactor trip breakers after the underfrequency trip setpoint is reached shall not exceed 0.6 seconds.
Turbine Trip A Turbine Trip causes a direct reactor trip when operating above P-9. Each of the turbine trips provide turbine protection and reduce the severity of the ensuing transient. No credit was taken in the accident analyses for operation of these trips. Their functional capability at the specified trip settings is required to enhance the overall reliability of the Reactor Protection System.
October 10, 2012 SEQUOYAH - UNIT 2 B 2-10 Amendment No. 132
LIMITING SAFETY SYSTEM SETTINGS BASES Safety Iniection Input from ESF If a reactor trip has not already been generated by the reactor protective instrumentation, the ESF automatic actuation logic channels will initiate a reactor trip upon any signal which initiates a safety injection. This trip is provided to protect the core in the event of a LOCA. The ESF instrumentation channels which initiate a safety injection signal are shown in Table 3.3-3.
Reactor Trip System Interlocks The Reactor Trip System Interlocks perform the following functions on increasing power:
P-6 Enables the manual block of the source range reactor trip (i.e.,
prevents premature block of source range trip).
P-7 Defeats the automatic block of reactor trip on: Low flow in more P-13 than one primary coolant loop, reactor coolant pump undervoltage and underfrequency, pressurizer low pressure, and pressurizer high level.
P-8 Defeats the automatic block of reactor trip on low RCS coolant flow in a single loop.
P-9 Defeats the automatic block of reactor trip on turbine trip.
P-1 0 Enables the manual block of reactor trip on power range (low setpoint), intermediate range, as a backup block for source range, and intermediate range rod stops (i.e., prevents premature block of the noted functions).
On decreasing power, the opposite function is performed at reset setpoints.
P-4 Reactor-tripped - Actuates turbine trip, closes main feedwater valves on Tav, below setpoint, prevents the opening of the main feedwater valves which were closed by a safety injection or high steam generator water level signal, allows manual block of the automatic reactuation of safety injection.
Reactor not tripped - defeats manual block preventing automatic reactuation of safety injection.
October 10, 2012 SEQUOYAH - UNIT 2 B 2-11 Amendment No. 132
POWER DISTRIBUTION LIMITS BASES 3/4.2.4 QUADRANT POWER TILT RATIO The QUADRANT POWER TILT RATIO limit assures that no anomaly exists such that the radial power distribution satisfies the design values used in the power capability analysis. Radial power distribution measurements are made during startup testing and periodically during power operation.
The QUADRANT POWER TILT RATIO limit at which corrective action is required provides DNB and linear heat generation protection with x-y plane power tilts. The QUADRANT POWER TILT RATIO limit is reflected by a corresponding peaking augmentation factor which is included in the generation of the AFD limits.
The 2-hour time allowance for operation with the tilt condition greater than 1.02 but less than 1.09, is provided to allow identification and correction of a dropped or misaligned control rod. In the event such action does not correct the tilt, the margin for uncertainty on FQ(X,Y,Z) is reinstated by reducing the allowable THERMAL POWER by 3 percent for each percent of tilt in excess of 1.02.
3/4.2.5 DNB PARAMETERS The limits on the DNB related parameters assure that each of the parameters are maintained within the normal steady state envelope of operation assumed in the transient and accident analyses.
The limits are consistent with the initial FSAR assumptions and have been analytically demonstrated adequate to maintain a minimum DNBR of greater than or equal to the safety analysis DNBR limit throughout each analyzed transient.
The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> periodic surveillance of these parameters through instrument readout is sufficient to ensure that the parameters are restored within their limits following load changes and other expected transient operation.
October 10, 2012 SEQUOYAH - UNIT 2 B 3/4 2-4 Amendment 21, 130, 146, 214, 324
INSTRUMENTATION BASES ACCIDENT MONITORING INSTRUMENTATION (Continued)
Determine whether systems important to safety are performing their intended functions.
Provide information to the operators that will enable them to determine the likelihood of a gross breach of the barriers to radioactivity release and to determine if a gross breach of a barrier has occurred.
For Sequoyah, the redundant channel capability for Auxiliary Feedwater (AFW) flow consists of a single AFW flow channel for each Steam Generator with the second channel consisting of three AFW valve position indicators (two level control valves for the motor driven AFW flowpath and one level control valve for the turbine drive AFW flowpath) for each steam generator.
March 5, 2013 SEQUOYAH - UNIT 2 B 3/4 3-3a Amendment Nos. 135, 149
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES APPLICABLE SAFETY ANALYSES The steam generator tube rupture (SGTR) accident is the limiting design basis event for SG tubes and avoiding an SGTR is the basis for this specification. The analysis of an SGTR event assumes a bounding primary to secondary leakage rate equal to the operational leakage rate limits in LCO 3.4.6.2 "Operational Leakage," plus the leakage rate associated with a double-ended rupture of a single tube. The accident analysis for a SGTR assumes the contaminated secondary fluid is released to the atmosphere via safety valves. The main condenser isolates based on an assumed concurrent loss of off-site power.
The analysis for design basis accidents and transients other than a SGTR assume the SG tubes retain their structural integrity (i.e., they are assumed not to rupture). In these analyses, the steam discharge to the atmosphere depends on the accident and whether there are faulted SGs associated with the accident. For a steamline break (SLB), the maximum primary to secondary leakage under accident conditions is limited to 3.7 gpm from the faulted SG and 0.1 gpm from each of the non-faulted SGs.
For other accidents that assume a faulted SG (e.g., feedwater line break), the maximum primary to secondary leakage under accident conditions is limited to 1.0 gpm from the faulted SG and 0.1 gpm from each of the non-faulted SGs. For accidents in which there are no faulted SGs, the primary to secondary leakage is limited to 0.1 gpm from each SG. For accidents that do not involve fuel damage, the primary coolant activity level of DOSE EQUIVALENT 1-131 is assumed to be equal to the LCO 3.4.8, "Specific Activity," limits. For accidents that assume fuel damage, the primary coolant activity is a function of the amount of activity released from the damaged fuel. The dose consequences of these events are within the limits of GDC 19 (Ref. 2), and 10 CFR 100 (Ref. 3).
Steam generator tube integrity satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii).
LCO The LCO requires that SG tube integrity be maintained. The LCO also requires that all SG tubes that satisfy the repair criteria be plugged in accordance with the Steam Generator Program.
During an SG inspection, any inspected tube that satisfies the Steam Generator Program repair criteria is removed from service by plugging. If a tube was determined to satisfy the repair criteria but was not plugged, the tube may still have tube integrity.
SEQUOYAH - UNIT 2 B 3/4 4-3a October 5, 2012 Amendment No. 181, 211, 213, 243, 267, 291,305, 309, 318, 323
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES LCO (continued)
In the context of this specification, a SG tube is defined as the entire length of the tube, including the tube wall, between the tube-to-tubesheet weld at the tube inlet and the tube-to-tubesheet weld at the tube outlet.
The tube-to-tubesheet weld is not considered part of the tube.
A SG tube has tube integrity when it satisfies the SG performance criteria.
The SG performance criteria are defined in Specification 6.8.4.k "Steam Generator Program," and describe acceptable SG tube performance.
The Steam Generator Program also provides the evaluation process for determining conformance with the SG performance criteria.
There are three SG performance criteria: structural integrity, accident induced leakage, and operational leakage. Failure to meet any one of these criteria is considered failure to meet the LCO.
The structural integrity performance criterion provides a margin of safety against tube burst or collapse under normal and accident conditions, and ensures structural integrity of the SG tubes under all anticipated transients included in the design specification. Tube burst is defined as, "The gross structural failure of the tube wall. The condition typically corresponds to an unstable opening displacement (e.g., opening area increased in response to constant pressure) accompanied by ductile (plastic) tearing of the tube material at the ends of the degradation.' Tube collapse is defined as, "For the load displacement curve for a given structure, collapse occurs at the top of the load versus displacement curve where the slope of the curve becomes zero." The structural integrity performance criterion provides guidance on assessing loads that have a significant effect on burst or collapse. In that context, the term "significant" is defined as "An accident loading condition other than differential pressure is considered significant when the addition of such loads in the assessment of the structural integrity performance criterion could cause a lower structural limit or limiting burst/collapse condition to be established." For tube integrity evaluations, except for circumferential degradation, axial thermal loads are classified as secondary loads. For circumferential degradation, the classification of axial thermal loads as primary or secondary loads will be evaluated on a case-by-case basis.
The division between primary and secondary classifications will be based on detailed analysis and/or testing.
October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3b Amendment No. 181, 211, 213, 243, 267, 291,305
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES LCO (continued)
Structural integrity requires that the primary membrane stress intensity in a tube not exceed the yield strength for all American Society of Mechanical Engineers (ASME) Code,Section III, Service Level A (normal operating conditions), and Service Level B (upset or abnormal conditions) transients included in the design specification. This includes safety factors and applicable design basis loads based on ASME Code,Section III, Subsection NB (Ref. 4) and Draft Regulatory Guide 1.121 (Ref. 5).
The accident induced leakage performance criterion ensures that the primary to secondary leakage caused by a design basis accident, other than a SGTR, is within the accident analysis assumptions. The accident analyses assumptions are discussed in the Applicable Safety Analyses section. The accident induced leakage rate includes any primary to secondary leakage existing prior to the accident in addition to primary to secondary leakage induced during the accident.
The operational leakage performance criterion provides an observable indication of SG tube conditions during plant operation. The limit on operational leakage is contained in LCO 3.4.6.2, "Operational Leakage,"
and limits primary to secondary leakage through any one SG to 150 gallons per day. This limit is based on the assumption that a single crack leaking this amount would not propagate to a SGTR under the stress conditions of a loss-of-coolant accident (LOCA) or a SLB. If this amount of leakage is due to more than one crack, the cracks are very small, and the above assumption is conservative.
APPLICABILITY Steam generator tube integrity is challenged when the pressure differential across the tubes is large. Large differential pressures across SG tubes can only be experienced in MODES 1, 2, 3, or 4.
Reactor coolant system (RCS) conditions are far less challenging in MODES 5 and 6 than during MODES 1, 2, 3, and 4. In MODES 5 and 6, primary to secondary differential pressure is low, resulting in lower stresses and reduced potential for leakage.
October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3c Amendment No. 181, 211, 213, 243, 267, 291,305, 323
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES ACTIONS The ACTIONs are modified by a clarifying footnote that Action (a) may be entered independently for each SG tube. This is acceptable because the actions provide appropriate compensatory measures for each affected SG tube. Complying with the actions may allow for continued operation, and subsequent affected SG tubes are governed by subsequent action entry, and application of associated actions.
Actions (a) and (b)
Action (a) applies if it is discovered that one or more SG tubes examined in an inservice inspection satisfy the tube repair criteria but were not plugged in accordance with the Steam Generator Program as required by SR 4.4.5.1. An evaluation of SG tube integrity of the affected tube(s) must be made. Steam generator tube integrity is based on meeting the SG performance criteria described in the Steam Generator Program. The SG repair criteria define limits on SG tube degradation that allow for flaw growth between inspections while still providing assurance that the SG performance criteria will continue to be met. In order to determine if a SG tube that should have been plugged has tube integrity, an evaluation must be completed that demonstrates that the SG performance criteria will continue to be met until the next refueling outage or SG tube inspection.
The tube integrity determination is based on the estimated condition of the tube at the time the situation is discovered and the estimated growth of the degradation prior to the next SG tube inspection. If it is determined that tube integrity is not being maintained until the next refueling outage or SG inspection, Action (a) requires unit shutdown and Action (b) requires the affected tube(s) be plugged.
An allowed time of 7 days is sufficient to complete the evaluation while minimizing the risk of plant operation with a SG tube that may not have tube integrity.
If the evaluation determines that the affected tube(s) have tube integrity, Action (a) allows plant operation to continue until the next refueling outage or SG inspection provided the inspection interval continues to be supported by an operational assessment that reflects the affected tubes.
However, the affected tube(s) must be plugged prior to startup following the next refueling outage or SG inspection. This allowed time is acceptable since operation until the next inspection is supported by the operational assessment.
October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3d Amendment No. 181, 211, 213, 243, 267, 291,305
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES ACTIONS (continued)
If SG tube integrity is not being maintained, the reactor must be brought to HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> and the affected tube(s) plugged prior to restart (Mode 4).
The action times are reasonable, based on operating experience, to reach the desired plant condition from full power in an orderly manner and without challenging plant systems.
SURVEILLANCE SR 4.4.5.0 REQUIREMENTS During shutdown periods the SGs are inspected as required by this SR and the Steam Generator Program. NEI 97-06, Steam Generator Program Guidelines (Ref. 1), and its referenced EPRI Guidelines, establish the content of the Steam Generator Program. Use of the Steam Generator Program ensures that the inspection is appropriate and consistent with accepted industry practices.
During SG inspections a condition monitoring assessment of the SG tubes is performed. The condition monitoring assessment determines the "as found" condition of the SG tubes. The purpose of the condition monitoring assessment is to ensure that the SG performance criteria have been met for the previous operating period.
The Steam Generator Program determines the scope of the inspection and ihe methods used to determine whether the tubes contain flaws satisfying the tube repair criteria. Inspection scope (i.e., which tubes or areas of tubing within the SG are to be inspected) is a function of existing and potential degradation locations. The Steam Generator Program also specifies the inspection methods to be used to find potential degradation.
Inspection methods are a function of degradation morphology, nondestructive examination (NDE) technique capabilities, and inspection locations.
October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3e Amendment No. 181, 211, 213, 243, 267, 291,305, 323
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES SURVEILLANCE REQUIREMENTS (continued)
The Steam Generator Program defines the frequency of SR 4.4.5.0. The frequency is determined by the operational assessment and other limits in the SG examination guidelines (Ref. 6). The Steam Generator Program uses information on existing degradations and growth rates to determine an inspection frequency that provides reasonable assurance that the tubing will meet the SG performance criteria at the next scheduled inspection. In addition, Specification 6.8.4.k contains prescriptive requirements concerning inspection intervals to provide added assurance that the SG performance criteria will be met between scheduled inspections.
SR 4.4.5.1 During an SG inspection, any inspected tube that satisfies the Steam Generator Program repair criteria is removed from service by plugging.
The tube repair criteria delineated in Specification 6.8.4.k are intended to ensure that tubes accepted for continued service satisfy the SG performance criteria with allowance for error in the flaw size measurement and for future flaw growth. In addition, the tube repair criteria, in conjunction with other elements of the Steam Generator Program, ensure that the SG performance criteria will continue to be met until the next inspection of the subject tube(s). Reference 1 provides guidance for performing operational assessments to verify that the tubes remaining in service will continue to meet the SG performance criteria.
The frequency of this surveillance ensures that the surveillance has been completed and all tubes meeting the repair criteria are plugged prior to subjecting the SG tubes to significant primary to secondary pressure differential (i.e., prior to HOT SHUTDOWN following a SG tube inspection).
October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-3f Amendment No. 181, 211, 213, 243, 267, 291,305
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES REFERENCES
- 1.
NEI 97-06, "Steam Generator Program Guidelines."
- 2.
- 3.
- 4.
ASME Boiler and Pressure Vessel Code,Section III, Subsection NB.
- 5.
Draft Regulatory Guide 1.121, "Basis for Plugging Degraded Steam Generator Tubes," August 1976.
- 6.
EPRI, "Pressurized Water Reactor Steam Generator Examination Guidelines."
SEQUOYAH - UNIT 2 B 3/4 4-3g October 5, 2012 Amendment No. 181, 211, 213, 243, 267, 291,305, 323
RCS Leakage Detection Instrumentation B 3/4.4.6 REACTOR COOLANT SYSTEM BASES Primary to secondary leakage is a factor in the dose releases outside containment resulting from a steam generator tube rupture or a steam line break (SLB) accident. To a lesser extent, other accidents or transients also involve secondary steam release to the atmosphere. The leakage contaminates the secondary fluid.
The FSAR (Ref. 3) analysis for steam generator tube rupture (SGTR) assumes the contaminated secondary fluid is released via safety valves for up to 30 minutes. Operator action is taken to isolate the affected steam generator within this time period. The 0.4 gpm operational primary to secondary leakage safety analysis assumption is relatively inconsequential.
The SLB is more limiting for site radiation releases. The safety analysis for the SLB accident assumes a 3.7 gpm primary to secondary leakage through the affected generator and 0.3 gpm through the non-affected generators as an initial condition. The dose consequences resulting from the SLB accident are well within the limits defined in 10 CFR 100 or the staff approved licensing basis (i.e.,
a small fraction of these limits). The expected leak rate following a steam line rupture is limited to below 3.7 gpm at atmospheric conditions and 70OF in the faulted loop, which will limit the calculated offsite doses to within 10 percent of the 10 CFR 100 guidelines.
The RCS operational leakage satisfies Criterion 2 of the NRC Policy Statement.
LCO RCS operational leakage shall be limited to:
- a.
PRESSURE BOUNDARY LEAKAGE No PRESSURE BOUNDARY LEAKAGE is allowed, being indicative of material deterioration. Leakage of this type is unacceptable as the leak itself could cause further deterioration, resulting in higher leakage.
Violation of this LCO could result in continued degradation of the RCPB.
Leakage past seals and gaskets is not PRESSURE BOUNDARY LEAKAGE.
- b.
UNIDENTIFIED LEAKAGE One gpm of UNIDENTIFIED LEAKAGE is allowed as a reasonable minimum detectable amount that the containment air monitoring and containment pocket October 5, 2012 SEQUOYAH - UNIT 2 B 3/4 4-4f Amendment No. 211, 213, 227, 250, 305, 323
ECCS - Shutdown B 3/4.5.3 B 3/4.5 EMERGENCY CORE COOLING SYSTEM (ECCS)
B 3/4.5.3 ECCS - Shutdown BASES BACKGROUND The Background section for Bases 3.5.2, "ECCS - Operating," is applicable to these Bases, with the following modifications. In MODE 4, the required ECCS train consists of two separate subsystems: centrifugal charging (high head) and residual heat removal (RHR) (low head). For the RHR subsystem during the injection phase, water is taken from the refueling storage tank (RWST) and injected in the Reactor Coolant System (RCS) through at least two cold legs.
The ECCS flow paths consist of piping, valves, heat exchangers, and pumps such that water from the refueling water storage tank (RWST) can be injected into the Reactor Coolant System (RCS) following the accidents described in Bases 3.5.2.
APPLICABLE SAFETY ANALYSES The Applicable Safety Analyses section of Bases 3.5.2 also applies to this Bases section.
Due to the stable conditions associated with operation in MODE 4 and the reduced probability of occurrence of a Design Basis Accident (DBA), the ECCS operational requirements are reduced. It is understood in these reductions that certain automatic safety injection (SI) actuation is not available. In this MODE, sufficient time exists for manual actuation of the required ECCS to mitigate the consequences of a DBA.
Only one train of ECCS is required for MODE 4. This requirement dictates that single failures are not considered during this MODE of operation.
One train of ECCS during the injection phase provides sufficient flow for core cooling, by the centrifugal charging subsystem supplying each of the four cold legs and the RHR subsystem supplying at least two cold legs, to meet the analysis requirements for a credible MODE 4 Loss of Coolant Accident (LOCA.)
The ECCS trains satisfy Criterion 3 of 10 CFR 50.36(c)(2)(ii).
LCO In MODE 4, one of the two independent (and redundant)
ECCS trains is required to be OPERABLE to ensure that sufficient ECCS flow is available to the core following a DBA.
SEQUOYAH - UNIT 2 March 24, 2012 BR35, BR38 B 3/4 5-12
ECCS - Shutdown B 3/4.5.3 BASES LCO (continued)
In MODE 4, an ECCS train consists of a centrifugal charging subsystem and an RHR subsystem. Each train includes the piping, instruments, and controls to ensure an OPERABLE flow path capable of taking suction from the RWST and transferring suction to the containment sump.
During an event requiring ECCS actuation, a flow path is required to provide an abundant supply of water from the RWST to the RCS via the ECCS pumps and their respective supply headers to the cold leg injection nozzles. In the long term, this flow path may be switched to take its supply from the containment sump and to deliver its flow to the RCS hot and cold legs.
Either RHR cold leg injection valve FCV-63-93 or FCV-63-94 may be closed when in MODE 4, for testing of the primary/secondary check valves in the injection lines. Closing one of the two cold leg injection flow paths does not make ECCS RHR subsystem inoperable.
This LCO is modified by a Note that allows an RHR train to be considered OPERABLE during alignment and operation for.decay heat removal, if capable of being manually realigned (remote or local) to the ECCS mode of operation and not otherwise inoperable. The manual actions necessary to realign the RHR subsystem may include actions to cool the RHR system piping due to the potential for steam voiding in piping or for inadequate NPSH available at the RHR pumps. This allows operation in the RHR mode during MODE 4.
APPLICABILITY In MODES 1, 2, and 3, the OPERABILITY requirements for ECCS are covered by LCO 3.5.2.
In MODE 4 with RCS temperature below 350 0F, one OPERABLE ECCS train is acceptable without single failure consideration, on the basis of the stable reactivity of the reactor and the limited core cooling requirements.
In MODES 5 and 6, plant conditions are such that the probability of an event requiring ECCS injection is extremely low. Core cooling requirements in MODE 5 are addressed by LCO 3.4.1.4, "Reactor Coolant System Cold Shutdown." MODE 6 core cooling requirements are addressed by LCO 3.9.8.1 "Residual Heat Removal and Coolant Circulation - All Water Levels," and LCO 3.9.8.2 "Residual Heat Removal and Coolant Circulation - Low Water Level."
March 24, 2012 SEQUOYAH - UNIT 2 B 3/4 5-13 BR35, BR36, BR38
ECCS - Shutdown B 3/4.5.3 BASES ACTIONS A Note prohibits the application of LCO 3.0.4b to an inoperable ECCS high head subsystem when entering MODE 4. There is an increased risk associated with entering MODE 4 from MODE 5 with an inoperable ECCS high head subsystem and the provisions of LCO 3.0.4b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
A second Note allows the required ECCS RHR subsystem to be inoperable because of surveillance testing of RCS pressure isolation valve leakage (FCV-74-1 and FCV-74-2). This allows testing while RCS pressure is high enough to obtain valid leakage data and following valve closure for RHR decay heat removal path. The condition requiring alternate heat removal methods ensures that the RCS heatup rate can be controlled to prevent MODE 3 entry and thereby ensure that the reduced ECCS operational requirements are maintained. The condition requiring manual realignment capability, FCV-74-1 and FCV-74-2 can be opened from the main control room ensures that in the unlikely event of a design basis accident during the one hour of surveillance testing, the RHR subsystem can be placed in ECCS recirculation mode when required to mitigate the event.
Action a.
With no ECCS RHR subsystem OPERABLE, the plant is not prepared to respond to a loss of coolant accident or to continue a cooldown using the RHR pumps and heat exchangers. The action time of immediately to initiate actions that would restore at least one ECCS RHR subsystem to OPERABLE status ensures that prompt action is taken to restore the required cooling capacity. Normally, in MODE 4, reactor decay heat is removed from the RCS by an RHR loop. If no RHR loop is OPERABLE for this function, reactor decay heat must be removed by some alternate method, such as use of the steam generators. The alternate means of heat removal must continue until the inoperable RHR loop components can be restored to operation so that decay heat removal is continuous.
With both RHR pumps and heat exchangers inoperable, it would be unwise to require the plant to go to MODE 5, where the only available heat removal system is the RHR. Therefore, the appropriate action is to initiate measures to restore one ECCS RHR subsystem and to continue the actions until the subsystem is restored to OPERABLE status.
March 24, 2012 SEQUOYAH - UNIT 2 B 3/4 5-14 BR35
ECCS - Shutdown B 3/4.5.3 BASES ACTIONS (continued)
Action b.
With no ECCS high head subsystem OPERABLE, due to the inoperability of the centrifugal charging pump or flow path from the RWST, the plant is not prepared to provide high pressure response to Design Basis Events requiring SI. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> action time to restore at least one ECCS high head subsystem to OPERABLE status ensures that prompt action is taken to provide the required cooling capacity or to initiate actions to place the plant in MODE 5, where an ECCS train is not required.
When Action b cannot be completed within the required action time, within one hour, a controlled shutdown should be initiated. Twenty four hours is a reasonable time, based on operating experience, to reach MODE 5 in an orderly manner and without challenging plant systems or operators.
SURVEILLANCE SR 4.5.3 REQUIREMENTS The applicable Surveillance descriptions from Bases 3.5.2 apply.
REFERENCES
- 1. The applicable references from Bases 3.5.2 apply.
- 2. NRC Safety Evaluation Report, NUREG-001 1, Section 1.1, "Introduction," regarding Amendment 49 dated January 6, 1978.
March 24, 2012 BR35, BR38 SEQUOYAH - UNIT 2 B 3/4 5-15
EMERGENCY CORE COOLING SYSTEMS BASES 3/4.5.4 BORON INJECTION SYSTEM This Specification was deleted.
3/4.5.5 REFUELING WATER STORAGE TANK The OPERABILITY of the refueling water storage tank (RWST), as part of the ECCS, ensures that a sufficient supply of borated water is available for injection by the ECCS in the event of a LOCA. The limits on RWST minimum volume and boron concentration ensure that 1) sufficient water is available within containment to permit recirculation-cooling flow to the core, and 2) the reactor will remain subcritical in the cold condition following mixing of the RWST and the RCS water volumes with all control rods inserted except for the most reactive control assembly. These assumptions are consistent with the LOCA analyses. Additionally, the OPERABILITY of the RWST, as part of the ECCS, ensures that sufficient negative reactivity is injected into the core to counteract any positive increase in reactivity caused by RCS cooldown.
The contained water volume limit includes an allowance for water not usable because of tank discharge line location or other physical characteristics.
The limits on contained water volume and boron concentration of the RWST also ensure a pH value of between 7.5 and 9.5 for the solution recirculated within containment after a LOCA. This pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion on mechanical systems and components.
March 24, 2012 SEQUOYAH - UNIT 2 B 3/4 5-16 Amendment No. 131, 288, 290
EMERGENCY CORE COOLING SYSTEM BASES 3/4.5.6 SEAL INJECTION FLOW BACKGROUND The function of the seal injection throttle valves during an accident is similar to the function of the ECCS throttle valves in that each restricts flow from the centrifugal charging pump header to the Reactor Coolant System (RCS).
The restriction on reactor coolant pump (RCP) seal injection flow limits the amount of ECCS flow that would be diverted from the injection path following an accident. This limit is based on safety analysis assumptions that are required because RCP seal injection flow is not isolated during safety injection.
APPLICABLE SAFETY ANALYSES All ECCS subsystems are taken credit for in the large break loss of coolant accident (LOCA) at full power (Ref. 1). The LOCA analysis establishes the minimum flow for the ECCS pumps. The centrifugal charging pumps are also credited in the small break LOCA analysis. This analysis establishes the flow and discharge head at the design point for the centrifugal charging pumps. The steam generator tube rupture and main steam line break event analyses also credit the centrifugal charging pumps, but are not limiting in their design. Reference to these analyses is made in assessing changes to the Seal Injection System for evaluation of their effects in relation to the acceptance limits in these analyses.
This LCO ensures that seal injection flow will be sufficient for RCP seal integrity but limited so that the ECCS trains will be capable of delivering sufficient water to match boiloff rates soon enough to minimize uncovering of the core following a large LOCA. It also ensures that the centrifugal charging pumps will deliver sufficient water for a small LOCA and sufficient boron to maintain the core subcritical. For smaller LOCAs, the charging pumps alone deliver sufficient fluid to overcome the loss and maintain RCS inventory.
Seal injection flow satisfies Criterion 2 of the NRC Policy Statement.
SEQUOYAH - UNIT 2 B 3/4 5-17 March 24, 2012 Amendment No. 131, 250
EMERGENCY CORE COOLING SYSTEM BASES LCO The intent of the LCO limit on seal injection flow is to make sure that flow through the RCP seal water injection line is low enough to ensure that sufficient centrifugal charging pump injection flow is directed to the RCS via the injection points (Ref. 2).
The LCO is not strictly a flow limit, but rather a flow limit based on a flow line resistance. In order to establish the proper flow line resistance, a pressure and flow must be known. The flow line resistance is established by adjusting the RCP seal injection needle valves to provide a total seal injection flow in the acceptable region of Technical Specification Figure 3.5.6-1. The centrifugal charging pump discharge header pressure remains essentially constant through all the applicable MODES of this LCO. A reduction in RCS pressure would result in more flow being diverted to the RCP seal injection line than at normal operating pressure. The valve settings established at the prescribed centrifugal charging pump discharge header pressure result in a conservative valve position should RCS pressure decrease. The flow limits established by Technical Specification Figure 3.5.6-1 are consistent with the accident analysis.
The limits on seal injection flow must be met to render the ECCS OPERABLE. If these conditions are not met, the ECCS flow will not be as assumed in the accident analyses.
APPLICABILITY In MODES. 1, 2, and 3, the seal injection flow limit is dictated by ECCS flow requirements, which are specified for MODES 1, 2, 3, and 4. The seal injection flow limit is not applicable for MODE 4 and lower, however, because high seal injection flow is less critical as a result of the lower initial RCS pressure and decay heat removal requirements in these MODES. Therefore, RCP seal injection flow must be limited in MODES 1, 2, and 3 to ensure adequate ECCS performance.
March 24, 2012 Amendment No. 250 SEQUOYAH - UNIT 2 B 3/4 5-18
EMERGENCY CORE COOLING SYSTEM BASES ACTION With the seal injection flow exceeding its limit, the amount of charging flow available to the RCS may be reduced. Under this condition, action must be taken to restore the flow to below its limit. The operator has 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> from the time the flow is known to be above the limit to correctly position the manual valves and thus be in compliance with the accident analysis. The completion time minimizes the potential exposure of the plant to a LOCA with insufficient injection flow and provides a reasonable time to restore seal injection flow within limits. This time is conservative with respect to the completion times of other ECCS LCOs; it is based on operating experience and is sufficient for taking corrective actions by operations personnel.
When the actions cannot be completed within the required completion time, a controlled shutdown must be initiated. The completion time of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> for reaching MODE 3 from MODE 1 is a reasonable time for a controlled shutdown, based on operating experience and normal cooldown rates, and does not challenge plant safety systems or operators. Continuing the plant shutdown from MODE 3, an additional 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is a reasonable time, based on operating experience and normal cooldown rates, to reach MODE 4, where this LCO is no longer applicable.
SURVEILLANCE Surveillance 4.5.6 REQUIREMENTS Verification every 31 days that the manual seal injection throttle valves are adjusted to give a flow within the limit ensures that proper manual seal injection throttle valve position, and hence, proper seal injection flow, is maintained. The differential pressure that is abode the reference minimum value is established between the charging header (PT 62-92) and the RCS, and total seal injection flow is verified to be within the limits determined in accordance with the ECCS safety analysis (Ref. 3). The seal water injection flow limits are shown in Technical Specification Figure 3.5.6-1. The frequency of 31 days is based on engineering judgment and is consistent with other ECCS valve surveillance frequencies. The frequency has proven to be acceptable through operating experience.
The requirements for charging flow vary widely according to plant status and configuration. When charging flow is adjusted, the positions of the air-operated valves, which control charging flow, March 24, 2012 SEQUOYAH - UNIT 2 B 3/4 5-19 Amendment No. 250
EMERGENCY CORE COOLING SYSTEM BASES are adjusted to balance the flows through the charging header and through the seal injection header to ensure that the seal injection flow to the RCPs is maintained between 8 and 13 gpm per pump.
The reference minimum differential pressure across the seal injection needle valves ensures that regardless of the varied settings of the charging flow control valves that are required to support optimum charging flow, a reference test condition can be established to ensure that flows across the needle valves are within the safety analysis. The values in the safety analysis for this reference set of conditions are calculated based on conditions during power operation and they are correlated to the minimum ECCS flow to be maintained under the most limiting accident conditions.
As noted, the surveillance is not required to be performed until 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> after the RCS pressure has stabilized within a +/- 20 psig range of normal operating pressure. The RCS pressure requirement is specified since this configuration will produce the required pressure conditions necessary to assure that the manual valves are set correctly. The exception is limited to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> to ensure that the surveillance is timely. Performance of this surveillance within the 4-hour allowance is required to maintain compliance with the provisions of Specification 4.0.3.
REFERENCES
- 1. FSAR, Chapter 6.3 "Emergency Core Cooling System" and Chapter 15.0 "Accident Analysis."
- 2.
- 3.
Westinghouse Electric Company Calculation CN-FSE-99-48 March 24, 2012 Amendment No. 250 SEQUOYAH - UNIT 2 B 3/4 5-20
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 AND 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS The OPERABILITY of the A.C. and D.C power sources and associated distribution systems during operation ensures that sufficient power will be available to supply the safety related equipment required for
- 1) the safe shutdown of the facility and 2) the mitigation and control of accident conditions within the facility. The minimum specified independent and redundant A.C. and D.C. power sources and distribution systems satisfy the requirements of General Design Criterion 17 of Appendix "A" to 10 CFR 50.
The electrically powered AC safety loads are separated into redundant load groups such that loss of any one load group will not prevent the minimum safety functions from being performed. Specification 3.8.1.1 requires two physically independent circuits between the offsite transmission network and the onsite Class 1 E Distribution System and four separate and independent diesel generator sets to be OPERABLE in MODES 1, 2, 3, and 4. These requirements ensure availability of the required power to shut down the reactor and maintain it in a safe shutdown condition after an abnormal operational transient or a postulated design basis accident.
Each offsite circuit must be capable of maintaining rated frequency and voltage, and accepting required loads during an accident. Minimum required switchyard voltages are determined by evaluation of plant accident loading and the associated voltage drops between the transmission network and these loads. These minimum voltage values are provided to TVA's Transmission Operations for use in system studies to support operation of the transmission network in a manner that will maintain the necessary voltages. Transmission Operations is required to notify SQN Operations if it is determined that the transmission network may not be able to support accident loading or shutdown operations as required by 10 CFR 50, Appendix A, GDC-17. Any offsite power circuits supplied by that transmission network that are not able to support accident loading or shutdown operations are inoperable.
The unit station service transformers (USSTs) utilize auto load tap changers to provide the required voltage response for accident loading. The load tap changer associated with a USST is required to be functional and in "automatic" for the USST to supply power to a 6.9 kV Unit Board.
The inability to supply offsite power to a 6.9 kV Shutdown Board constitutes the failure of only one offsite circuit, as long as offsite power is available to the other load group's Shutdown Boards. Thus, if one or both 6.9 kV Shutdown Boards in a load group do not have an offsite circuit available, then only one offsite circuit would be inoperable. If one or more Shutdown Boards in each load group, or all four Shutdown Boards, do not have an offsite circuit available, then both offsite circuits would be inoperable.
An "available" offsite circuit meets the requirements of GDC-1 7, and is either connected to the 6.9 kV Shutdown Boards or can be connected to the 6.9 kV Shutdown Boards within a few seconds.
An offsite circuit consists of all breakers, transformers, switches, interrupting devices, cabling, and controls required to transmit power from the offsite transmission network (beginning at the switchyard) to one load group of Class 1 E 6.9 kV Shutdown Boards (ending at the supply side of the normal or alternate supply circuit breaker). Each required offsite circuit is that combination of power sources described below that are normally connected to the Class 1 E distribution system, or can be connected to the Class 1 E distribution system through automatic transfer at the 6.9 kV Unit Boards.
The following offsite power configurations meet the requirements of LCO 3.8.1.1.a:
(Note that common station service transformer (CSST) B is a spare transformer with two sets of secondary windings that can be used to supply a total of two Start Buses for CSST A and/or CSST C, with each supplied Start Bus on a separate CSST B secondary winding.)
December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-1 Amendment No. 123, 164, 195, 231, 272, 325
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
- 1. Two offsite circuits consisting of a AND b (no board transfers required; a loss of either circuit will not prevent the minimum safety functions from being performed):
- a.
From the 161 kV transmission network, through CSST A (winding X) to Start Bus 1A to 6.9 kV Shutdown Board 1B-B (through 6.9 kV Unit Board lC), and CSST A (winding Y) to Start Bus 2A to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C); AND
- b.
From the 161 kV transmission network, through CSST C (winding X) to Start Bus 2B to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B), and CSST C (winding Y) to Start Bus 1B to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B).
- 2. Two offsite circuits consisting of a AND b (relies on automatic transfer from alignment a.1) to b.2)(b),
or a.2) to b.1)(a) on a loss of (USSTs) 1A and 1B, OR relies on automatic transfer from alignment a.3) to b.2)(a), or a.4) to b. 1)(b) on a loss of USSTs 2A and 2B):
- a.
Normal power source alignments
- 1) From the 500 kV switchyard through USST 1A to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B);
- 2) From the 500 kV switchyard through USST 1 B to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board lC);
- 3) From the 161 kV switchyard through USST 2A to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B); AND
- 4)
From the 161 kV switchyard through USST 2B to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C).
- b.
Alternate power source alignments
- 1) From the 161 kV transmission network, through:
(a) CSST A (winding X) to Start Bus 1A to 6.9 kV Shutdown Board 1B-B (through 6.9 kV Unit Board 1C); AND (b) CSST A (winding Y) to Start Bus 2A to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C); OR
- 2)
From the 161 kV transmission network, through:
(a) CSST C (winding X) to Start Bus 2B to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B), AND (b) CSST C (winding Y) to Start Bus 1B to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B).
December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-2 Amendment No. 123, 164, 195, 224, 231,274, 290, 325
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
- 3.
Two offsite circuits consisting of a AND b (relies on automatic transfer from alignment a. 1) to b. 1) and b.2) on a loss of the Unit 2 USSTs; a loss of alignment a.2) or a.3) will not prevent the minimum safety functions from being performed):
- a.
Normal power source alignments
- 1) From the 161 kV switchyard through USST 2A to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B), and USST 2B to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C);
- 2)
From the 161 kV transmission network, through CSST A (winding X) to Start Bus 1A to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board 1 C); AND
- 3)
From the 161 kV transmission network, through CSST C (winding Y) to Start Bus 1B to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B).
- b.
Alternate power. source alignments
- 1) From the 161 kV transmission network, through CSST A (winding Y) to Start Bus 2A to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C); AND
- 2)
From the 161 kV transmission network, through CSST C (winding X) to Start Bus 2B to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B).
- 4.
Two offsite circuits consisting of a AND b (relies on automatic transfer from alignment a.1) to b. 1) and b.2) on a loss of the Unit 1 USSTs; a loss of alignment a.2) or a.3) will not prevent the minimum safety functions from being performed):
- a.
Normal power source alignments
- 1) From the 500 kV switchyard through USST 1A to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1 B), and USST 1 B to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board 1C);
- 2) From the 161 kV transmission network, through CSST A (winding Y) to Start Bus 2A to 6.9 kV Shutdown Board 2B-B (through 6.9 kV Unit Board 2C); AND
- 3)
From the 161 kV transmission network, through CSST C (winding X) to Start Bus 2B to 6.9 kV Shutdown Board 2A-A (through 6.9 kV Unit Board 2B).
- b.
Alternate power source alignments
- 1) From the 161 kV transmission network, through CSST A (winding X) to Start Bus 1A to 6.9 kV Shutdown Board 1 B-B (through 6.9 kV Unit Board lC); AND
- 2)
From the 161 kV transmission network, through CSST C (winding Y) to Start Bus 1 B to 6.9 kV Shutdown Board 1A-A (through 6.9 kV Unit Board 1B).
December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-3 Amendment No 123, 164, 195, 224, 274, 325
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
Other offsite configurations are possible using different combinations of available USSTs and CSSTs, as long as the alignments are consistent with the analyzed configurations, and the alignments otherwise comply with the requirements of GDC 17.
For example, to support breaker testing, offsite power to the 6.9 kV Shutdown Boards can be realigned from normal feed to alternate feed. This would result in Shutdown Boards 1A-A and 2A-A being fed from Unit Boards 1A and 2A, respectively, and Shutdown Boards 1B-B and 2B-B being fed from Unit Boards 1D and 2D, respectively. The CSST being utilized as the alternate power source to one load group of Shutdown Boards would also be realigned (normally CSST A available to Shutdown Boards 1 B-B and 2B-B or CSST C available to Shutdown Boards 1A-A and 2A-A, would be realigned to CSST A available to Shutdown Boards 1A-A and 2A-A or CSST C available to Shutdown Boards 1 B-B and 2B-B).
LCO 3.8.1.1 is modified by Note @ that specifies CSST A and CSST C are required to be available via automatic transfer at the associated 6.9 KV Unit Boards, when USST 2A and USST 2B are being utilized as normal power sources to the offsite circuits. (Note that CSST B can be substituted for CSST A or CSST C.) This offsite power alignment is consistent with Configuration 3, as stated above.
Note @ remains in effect until November 30, 2013, or until the USST modifications are implemented on Units 1 and 2, whichever occurs first. (The scheduled startup from the Unit 1 fall 2013 refueling outage is November 2013.) Following expiration of Note @, Configuration 3 can continue to be used.
The ACTION requirements specified for the levels of degradation of the power sources provide restriction upon continued facility operation commensurate with the level of degradation. The OPERABILITY of the power sources are consistent with the initial condition assumptions of the safety analyses and are based upon maintaining at least one redundant set of onsite A.C. and D.C. power sources and associated distribution systems OPERABLE during accident conditions coincident with an assumed loss of offsite power and single failure of the other onsite A.C. source.
The footnote for Action b of LCO 3.8.1.1 requires completion of a determination that the OPERABLE diesel generators are not inoperable due to common cause failure or performance of Surveillance 4.8.1.1.2.a.4 if Action b is entered. The intent is that all diesel generator inoperabilities must be investigated for common cause failures regardless of how long the diesel generator inoperability persists.
Action b of LCO 3.8.1.1 is further modified by a second note which precludes making more than one diesel generator inoperable on a pre-planned basis for maintenance, modifications, or surveillance testing. The intent of this footnote is to explicitly exclude the flexibility of removing a diesel generator set from service as a part of a pre-planned activity. While the removal of a diesel generator set (A or B train) is consistent with the initial condition assumptions of the accident analysis, this configuration is judged as imprudent. The term pre-planned is to be taken in the context of those activities which are routinely scheduled and is not relative to conditions which arise as a result of emergent or unforeseen events. As an example, this footnote is not intended to preclude the actions necessary to perform the common mode testing requirements required by Action b. As another example, this footnote is not intended to prevent the required surveillance testing of the diesel generators should one diesel generator maintenance be unexpectedly extended and a second diesel generator fall within its required testing frequency. Thus, application of the note is intended for pre-planned activities.
December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-4 Amendment No. 123, 164, 195, 231, 272, 325
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
In addition, this footnote is intended to apply only to those actions taken directly on the diesel generator. For those actions taken relative to common support systems (e.g. ERCW), the support function must be evaluated for impact on the diesel generator.
The action to determine that the OPERABLE diesel generators are not inoperable due to common cause failures provides an allowance to avoid unnecessary testing of OPERABLE diesel generators. If it can be determined that the cause of the inoperable diesel generator does not exist on the OPERABLE diesel generators, Surveillance Requirement 4.8.1.1.2.a.4 does not have to be performed. If the cause of inoperability exists on other diesel generator(s), the other diesel generator(s) would be declared inoperable upon discovery and Action e of LCO 3.8.1.1 would be entered as applicable. Once the common failure is repaired, the common cause no longer exists, and the action to determine inoperability due to common cause failure is satisfied. If the cause of the initial inoperable diesel generator cannot be confirmed not to exist on the remaining diesel generators, performance of Surveillance 4.8.1.1.2.a.4 suffices to provide assurance of continued OPERABILITY of the other diesel generators.
According to Generic Letter 84-15, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is reasonable to confirm that the OPERABLE diesel generators are not affected by the same problem as the inoperable diesel generator.
Action f prohibits the application of LCO 3.0.4.b to an inoperable diesel generator. There is an increased risk associated with entering a MODE or other specified condition in the Applicability with an inoperable diesel generator and the provisions of LCO 3.0.4.b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
The OPERABILITY of the minimum specified A.C. and D.C. power sources and associated distribution systems during shutdown and refueling ensures that 1) the facility can be maintained in the shutdown or refueling condition for extended time periods and 2) sufficient instrumentation and control capability is available for monitoring and maintaining the unit status.
With the minimum required AC power sources not available, it is required to suspend CORE ALTERATIONS and operations involving positive reactivity additions that could result in loss of required SDM (Mode 5) or boron concentration (Mode 6). Suspending positive reactivity additions that could result in failure to meet minimum SDM or boron concentration limit is required to assure continued safe operation. Introduction of coolant inventory must be from sources that have a boron concentration greater than or equal to that required in the RCS for minimum SDM or refueling boron concentration. This may result in an overall reduction in RCS boron concentration but provides acceptable margin to maintaining subcritical operation. Introduction of temperature changes including temperature increases when operating with a positive MTC must also be evaluated to ensure they do not result in a loss of required SDM.
The requirements of Specification 3.8.2.1 provide those actions to be taken for the inoperability of A.C. Distribution Systems. Action a of this specification provides an 8-hour action for the inoperability of one or more A.C. boards. Action b of this specification provides a relaxation of the 8-hour action to 24-hours provided the Vital Instrument Power Board is inoperable solely as a result of one inoperable inverter and the board has been energized within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. In this condition the requirements of Action a do not have to be applied. Action b is not intended to provide actions for inoperable inverters, which is addressed by the operability requirements for the boards, and is included only for relief from the 8-hour December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-5 Amendment No.123, 164, 195, 224, 231,274, 290
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued) action of Action a when only one inverter is affected. More than one inverter inoperable will result in the inoperability of the associated 120 Volt A.C. Vital Instrument Power Board(s) in accordance with Action a.
With more than one inverter inoperable entry into the actions of TS 3.0.3 is not applicable because Action a includes provisions for multiple inoperable inverters as attendant equipment to the boards.
The Surveillance Requirements for demonstrating the OPERABILITY of the diesel generators are in accordance with the recommendations of Regulatory Guides 1.9 "Selection of Diesel Generator Set Capacity for Standby Power Supplies", March 10, 1971, 1.108 "Periodic Testing of Diesel Generator Units Used as Onsite Electric Power Systems at Nuclear Power Plants," Revision 1, August 1977, and 1.137 "Fuel-Oil Systems for Standby Diesel Generators," Revision 1, October 1979. The surveillance requirements for the diesel generator load-run test and the 24-hour endurance and margin test are in accordance with Regulatory Guide 1.9, Revision 3, July 1993, "Selection, Design, Qualification, and Testing of Emergency Diesel Generator Units Used as Class 1 E Onsite Electric Power Systems at Nuclear Power Plant." During the diesel generator endurance and margin surveillance test, momentary transients outside the kw and kvar load ranges do not invalidate the test results. Similarly, during the diesel generator load-run test, momentary transients outside the kw load range do not invalidate the test results.
Where the SRs discussed herein specify voltage and frequency tolerances, the following is applicable. 6800 volts is the minimum steady state output voltage and the 10 second transient value.
6800 volts is 98.6% of nominal bus voltage of 6900 volts and is based on the minimum voltage required for the diesel generator supply breaker to close on the 6.9 kV Shutdown Board. The specified maximum steady state output voltage of 7260 volts is based on the degraded over voltage relay setpoint and is equivalent to 110% of the nameplate rating of the 6600 volt motors. The specified minimum and maximum frequencies of the diesel generator are 58.8 Hz and 61.2 Hz, respectively. These values are equal to +/- 2% of the 60 Hz nominal frequency and are derived from the recommendations given in regulatory Guide 1.9.
Where the SRs discuss maximum transient voltages during load rejection testing, the following is applicable. The maximum transient voltage of 8880 volts represents a conservative limit to ensure the resulting voltage will not exceed a level that will cause component damage. It is based on the manufacturer's recommended high potential test voltage of 60% of the original factory high potential test voltage (14.8 kV). The diesel generator manufacturer has determined that the engine and/or generator controls would not experience detrimental effects for transient voltages < 9000 volts. The maximum transient voltage of 8276 volts is retained from the original technical specifications to ensure that the voltage transient following rejection of the single largest load is within the limits originally considered acceptable. It was based on 114% of 7260 volts, which is the Range B service voltage per ANSI-C84.1.
The Surveillance Requirement (SR) to transfer the power supply to each 6.9 kV Unit Board from the normal supply to the alternate supply demonstrates the OPERABILITY of the alternate supply to power the shutdown loads. The 18 month Frequency of the Surveillance is based on engineering judgment, taking into consideration the unit conditions required to perform the Surveillance, and is intended to be consistent with expected fuel cycle lengths. Operating experience has shown that these components usually pass the SR when performed at the 18 month Frequency. Therefore, the Frequency was concluded to be acceptable from a reliability standpoint. This SR is modified by two Notes. The reason for Note # is that, during operation with the reactor critical, performance of this SR for the Unit 2 December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-6 Amendment No. 123, 164, 195, 224, 231,274, 290, 325
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
Unit Boards could cause perturbations to the electrical distribution systems that could challenge continued steady state operation and, as a result, unit safety systems. Note ## specifies that transfer capability is only required to be met for 6.9 kV Unit Boards that require normal and alternate power supplies. When both load groups are being supplied power by the USSTs, only the 6.9 kV Unit Boards associated with one load group are required to have normal and alternate power supplies. Therefore, only one CSST is required to be OPERABLE and available as an alternate power supply. Additionally, manual transfers between the normal supply and the alternate supply are not relied upon to meet the accident analysis. Manual transfer capability is verified to ensure the availability of a backup to the automatic transfer feature.
The Surveillance Requirement for demonstrating the OPERABILITY of the Station batteries are based on the recommendations of Regulatory Guide 1.129 "Maintenance Testing and Replacement of Large Lead Storage Batteries for Nuclear Power Plants," February 1978, and IEEE Std 450-1980, "IEEE Recommended Practice for Maintenance, Testing and Replacement of Large Lead Storage Batteries for Generating Stations and Substations."
Verifying average electrolyte temperature above the minimum for which the battery was sized, total battery terminal voltage onfloat charge, connection resistance values and the performance of battery service and discharge tests ensures the effectiveness of the charging system, the ability to handle high discharge rates and compares the battery capacity at that time with the rated capacity.
Table 4.8-2 specifies the normal limits for each designated pilot cell and each connected cell for electrolyte level, float voltage and specific gravity. The limits for the designated pilot cells float voltage and specific gravity, greater than 2.13 volts and.015 below the manufacturer's full charge specific gravity or a battery charger current that had stabilized at a low value, is characteristic of a charged cell with adequate capacity. The normal limits for each connected cell for float voltage and specific gravity, greater than 2.13 volts and not more than.020 below the manufacturer's full charge specific gravity with an average specific gravity of all the connected cells not more than.010 below the manufacturer's full charge specific gravity, ensures the OPERABILITY and capability of the battery.
Operation with a battery cell's parameter outside the normal limit but within the allowable value specified in Table 4.8-2 is permitted for up to 7 days. During this 7 day period: (1) the allowable values for electrolyte level ensures no physical damage to the plates with an adequate electron transfer capability; (2) the allowable value for the average specific gravity of all the cells, not more than.020 below the manufacturer's recommended full charge specific gravity, ensures that the decrease in rating will be less than the safety margin provided in sizing; (3) the allowable value for an individual cell's specific gravity, ensures that an individual cell's specific gravity will not be more than.040 below the manufacturer's full charge specific gravity and that the overall capability of the battery will be maintained within an acceptable limit; and (4) the allowable value for an individual cell's float voltage, greater than 2.07 volts, ensures the battery's capability to perform its design function.
The test listed below is a means of determining whether new fuel oil is of the appropriate grade and has not been contaminated with substances that would have an immediate, detrimental impact on diesel engine combustion. If the results from this test is within acceptable limits, the fuel oil may be added to the storage tanks without concern for contaminating the entire volume of fuel oil in the storage December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-7 Amendment No. 12, 137, 250, 252, 325
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued) tanks. This test is to be conducted prior to adding the new fuel to the storage tank(s), but in no case is the time between receipt of new fuel and conducting the test to exceed 31 days. The test, limits, and applicable ASTM Standards are as follows:
- a.
Sample the new fuel in accordance with D4057-1988 (ref.);
- b.
Verify in accordance with the test specified in ASTM D975-1990 (Ref.) that the sample has an absolute specific gravity at 60/60 degrees F of _> 0.83 and _< 0.89 or an API gravity at 60 degrees F of
>_ 27 degrees and < 39 degrees, a kinematic viscosity at 40 degrees C of > 1.9 centistokes and < 4.1 centistokes, and a flash point of >_ 125 degrees F; and
- c.
Verify that the new fuel oil has a clear and bright appearance with proper color when tested in accordance with ASTM D4176-1986 (Ref.).
Failure to meet any of the above limits is cause for rejecting the new fuel oil, but does not represent a failure to meet LCO concern since the fuel oil is not added to the storage tanks.
Within 31 days following the initial new fuel oil sample, the fuel oil is analyzed to establish that the other properties specified in Table 1 of ASTM D975-1990 (Ref.) are met, except that the analysis for sulfur may be performed in accordance with ASTM D1 552-1990 (Ref.) or ASTM D2622-1987 (Ref.). The 31 day period is acceptable because the fuel oil properties of interest, even if they were not within stated limits, would not have an immediate effect on DIG operation. This surveillance ensures availability of high quality fuel oil for the D/Gs.
Fuel oil degradation during long term storage shows up as an increase in particulate, due mostly to oxidation. The presence of particulate does not mean the fuel oil will not burn properly in a diesel engine.
The particulate can cause fouling of filters and fuel oil injection equipment, however, which can cause engine failure.
Particulate concentrations should be determined in accordance with ASTM D2276-94, Method A (Ref.). This method involves a gravimetric determination of total particulate concentration in the fuel oil and has a limit of 10 mg/I. It is acceptable to obtain a field sample for subsequent laboratory testing in lieu of field testing. Each of the four interconnected tanks which comprise a 7-day tank must be considered and tested separately.
The frequency of this test takes into consideration fuel oil degradation trends that indicate that particulate concentration is unlikely to change significantly between frequency intervals.
References:
ASTM Standards D4057-1988, "Practice for manual sampling of petroleum and petroleum Products."
D975-1990, "Standard Specifications for Diesel Fuel oils."
D4176-1986, "Free Water and Particulate Contamination in Distillate Fuels."
D1552-1990, "Standard Test Method for Sulfur in Petroleum Products (High Temperature Method)."
December 21, 2012 SEQUOYAH - UNIT 2 B 3/4 8-8 Amendment No. 123, 241, 252
3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1 and 3/4.8.2 A.C. SOURCES AND ONSITE POWER DISTRIBUTION SYSTEMS (Continued)
D2622-1987, "Standard Test Method for Sulfur in Petroleum Products (X-Ray Spectrographic Method)."
D2276-1994, "Standard Test Method for Particulate Containment in Aviation Turbine Fuels."
D1298-1985, "Standard Test Method for Density, Specific Gravity, or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method."
3/4.8.3 ELECTRICAL EQUIPMENT PROTECTIVE DEVICES This specification is deleted.
SEQUOYAH - UNIT 2 December 21, 2012 Amendment No. 123, 241, 252 B 3/4 8-9