ML12269A650: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 2: Line 2:
| number = ML12269A650
| number = ML12269A650
| issue date = 07/03/2012
| issue date = 07/03/2012
| title = 2012/07/03 Davis-Besse Lr - FW: Draft RAI 4.2.4-1 - Pressure-Temperature (P-T) Limits (Revised RAI)
| title = Lr - FW: Draft RAI 4.2.4-1 - Pressure-Temperature (P-T) Limits (Revised RAI)
| author name =  
| author name =  
| author affiliation = - No Known Affiliation
| author affiliation = - No Known Affiliation

Latest revision as of 19:09, 5 December 2019

Lr - FW: Draft RAI 4.2.4-1 - Pressure-Temperature (P-T) Limits (Revised RAI)
ML12269A650
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 07/03/2012
From:
- No Known Affiliation
To:
Division of License Renewal
References
Download: ML12269A650 (5)


Text

Davis-BesseNPEm Resource From: custerc@firstenergycorp.com Sent: Tuesday, July 03, 2012 11:48 AM To: CuadradoDeJesus, Samuel Cc: dorts@firstenergycorp.com

Subject:

Re: FW: Draft RAI 4.2.4 Pressure-Temperature (P-T) Limits (REVISED RAI)

Attachments: DB Revised RAI 4.2.4-1 6 25 2012 Sydnor.docx After internal discussion, we will not need the additional teleconference on this issue. Thank you for the coordination.

Cliff Custer FENOC Project Manager License Renewal From: "CuadradoDeJesus, Samuel" <Samuel.CuadradoDeJesus@nrc.gov>

To: "custerc@firstenergycorp.com" <custerc@firstenergycorp.com>, "dorts@firstenergycorp.com" <dorts@firstenergycorp.com>

Cc: "Harris, Brian" <Brian.Harris2@nrc.gov>, Davis-BesseHearingFile Resource <Davis-BesseHearingFile.Resource@nrc.gov>

Date: 07/03/2012 11:00 AM

Subject:

FW: Draft RAI 4.2.4 Pressure-Temperature (P-T) Limits (REVISED RAI)

Cliff and Steve, Well have to schedule the teleconference sometime next week. Also itll be very helpful to the staff if you can send us in advance and in writing (by e-mail) a summary of whats the clarification you need from the staff related to the revised P-T RAI.

Regards, From: CuadradoDeJesus, Samuel Sent: Monday, June 25, 2012 2:43 PM To: custerc@firstenergycorp.com; 'dorts@firstenergycorp.com' Cc: Harris, Brian; Davis-BesseHearingFile Resource; Sydnor, Christopher

Subject:

Draft RAI 4.2.4 Pressure-Temperature (P-T) Limits (REVISED RAI)

Importance: High

Cliff, I believe I mentioned this to you last week. The staff revised the P-T limits RAI (see draft RAI 4.2.4-1 attached). The attached draft RAI 4.2.4-1 supersedes RAI 4.2.2-4 sent on May 31, 2012. Let me know if you need clarification and Ill schedule a telephone conference call.
Regards, Samuel Cuadrado de Jesús Project Manager Projects Branch 1 Division of License Renewal U.S. Nuclear Regulatory Commission Phone: 301-415-2946 Samuel.CuadradoDeJesus@nrc.gov

The information contained in this message is intended only for the personal 1

and confidential use of the recipient(s) named above. If the reader of this message is not the intended recipient or an agent responsible for delivering it to the intended recipient, you are hereby notified that you have received this document in error and that any review, dissemination, distribution, or copying of this message is strictly prohibited. If you have received this communication in error, please notify us immediately, and delete the original message.

2

Hearing Identifier: Davis_BesseLicenseRenewal_Saf_NonPublic Email Number: 3894 Mail Envelope Properties (OFC63457B4.78927F3C-ON85257A30.0052A2A5-85257A30.0056C213)

Subject:

Re: FW: Draft RAI 4.2.4 Pressure-Temperature (P-T) Limits (REVISED RAI)

Sent Date: 7/3/2012 11:47:37 AM Received Date: 7/3/2012 11:47:45 AM From: custerc@firstenergycorp.com Created By: custerc@firstenergycorp.com Recipients:

"dorts@firstenergycorp.com" <dorts@firstenergycorp.com>

Tracking Status: None "CuadradoDeJesus, Samuel" <Samuel.CuadradoDeJesus@nrc.gov>

Tracking Status: None Post Office: FirstEnergyCorp.com Files Size Date & Time MESSAGE 2409 7/3/2012 11:47:45 AM DB Revised RAI 4.2.4-1 6 25 2012 Sydnor.docx 27298 Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:

Recipients Received:

SUPPLEMENTAL REQUEST FOR ADDITIONAL INFORMATION LICENSE RENEWAL APPLICATION, SECTION 4.2 TIME-LIMITED AGING ANALYSES OF NEUTRON EMBRITTLEMENT DAVIS-BESSE NUCLEAR POWER STATION FIRST ENERGY NUCLEAR OPERATING COMPANY DOCKET NO. 50-346 Draft RAI 4.2.4 Pressure-Temperature (P-T) Limits

1.0 BACKGROUND

The Davis-Besse License Renewal Application (LRA), Section 4.2.4 describes the time-limited aging analysis for the pressure-temperature (P-T) limit curves at Davis-Besse. As stated in LRA Section 4.2.4, the Davis-Besse P-T limit curves are established in a P-T Limits Report (PTLR),

the contents of which are controlled in accordance with Technical Specification (TS) 5.6.4 requirements. The current Davis-Besse PTLR contains P-T limit curves that are valid through 32 effective full power years of facility operation. LRA Section 4.2.4 states that the P-T limit curves, as established in the PTLR, will be updated as necessary in accordance with TS 5.6.4 requirements and managed for the period of extended operation, as part of the Reactor Vessel Surveillance Program (LRA Appendix B, Section B.2.35), in accordance with the requirements of Title 10 of the Code of Federal Regulations (10 CFR) 54.21(c)(1)(iii).

10 CFR Part 50, Appendix G, Paragraph IV.A states that, the pressure-retaining components of the reactor coolant pressure boundary [RCPB] that are made of ferritic materials must meet the requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code [ASME Code, Section III], supplemented by the additional requirements set forth in

[paragraph IV.A.2, Pressure-Temperature (P-T) Limits and Minimum Temperature Requirements"] Therefore, 10 CFR Part 50, Appendix G requires that P-T limits be developed for the ferritic materials in the reactor vessel (RV) beltline (neutron fluence 1 x 1017 n/cm2, E > 1 MeV), as well as ferritic materials not in the RV beltline (neutron fluence < 1 x 1017 n/cm2, E > 1 MeV). Further, 10 CFR Part 50, Appendix G requires that all RCPB components must meet the American Society of Mechanical Engineers (ASME) Code,Section III requirements. The relevant ASME Code,Section III requirement that will affect the P-T limits is the lowest service temperature requirement for all RCPB components specified in Section III, NB-2332(b).

2.0 ISSUE P-T limit calculations for ferritic RCPB components that are not RV beltline shell materials may define P-T curves that are more limiting than those calculated for the RV beltline shell materials.

This may be due to the following factors:

1. RV nozzles, penetrations, and other discontinuities have complex geometries that may exhibit significantly higher stresses than those for the RV beltline shell region. These higher stresses can potentially result in more restrictive P-T limits, even if the reference temperature (RTNDT) for these components is not as high as that of RV beltline shell materials that have simpler geometries.
2. Ferritic RCPB components that are not part of the RV may have initial RTNDT values, which may define a more restrictive lowest operating temperature in the P -T limits than those for the RV beltline shell materials.

3.0 REQUEST Describe how the P-T limit curves to be developed for use in the period of extended operation, and the methodology used to develop these curves, consider all RV materials (beltline and non-beltline) and the lowest service temperature of all ferritic RCPB materials, consistent with the requirements of 10 CFR Part 50, Appendix G.