ML18219B309: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(2 intermediate revisions by the same user not shown)
Line 3: Line 3:
| issue date = 08/07/2018
| issue date = 08/07/2018
| title = Registration of Use of Casks to Store Spent Fuel
| title = Registration of Use of Casks to Store Spent Fuel
| author name = Libra R W
| author name = Libra R
| author affiliation = Exelon Generation Co, LLC
| author affiliation = Exelon Generation Co, LLC
| addressee name =  
| addressee name =  
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:Exelon Gene r atio n LG-18-089 August7,2018 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001  
{{#Wiki_filter:Exelon Generation                                                                  10 CFR 72.212 LG-18-089 August7,2018 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352. 50-353. and 72-065


==Subject:==
==Subject:==
Limerick Generating Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352. 50-353. and 72-065 Registration of Use of Casks to Store Spent Fuel 10 CFR 72.212 In accordance with 10 CFR 72.212, "Conditions of general license issued under §72.210," paragraph (b)(2), Exelon Generation Company, LLC (EGC) is registering, with the NRC, the use of three casks under the general license to store spent fuel at Limerick Generating Station (LGS). The casks were placed into service with stored spent fuel on July 13, 2018, July 19, 2018 and July 27, 2018. This registration is required to be submitted within 30 days of the cask in-service date. Accordingly, this submittal is due by August 12, 2018. The following information is provided in accordance with 10 CFR 72.212(b)(2). Licensee Name: Licensee Address: Exelon Generation Company, LLC Limerick Generating Station 3146 Sanatoga Road Pottstown, PA 19464 Renewed Reactor License Numbers: NPF-39 and NPF-85 Reactor Docket Numbers: 50-352, 50-353 Independent Spent Fuel Storage Installation Docket Number: 72-065 Contact Name and Title: Robert B. Dickinson Manager -Regulatory Assurance August7,2018 U.S. Nuclear Regulatory Commission Page2 Cask Certificate Number: Cask Model Number: HSM Model Number: Service Date: Cask Identification Number: HSM Identification Number: Service Date: Cask Identification Number: HSM Identification Number: Service Date: Cask Identification Number: HSM Identification Number: 1004, Amendment 10 NUHOMS-61 BTH HSM*H July 13, 2018 LGS-61 BTH1-D-2H-044 HSM-048 July 19, 2018 LGS-61 BTH1-D-2H-045 HSM-050 July 27, 2018 LGS-61 BTH1-D-2H-046 HSM-052 In addition, this letter provides information for each DSC that is required by Certificate of Compliance (CoC) No. 1004, Amendment No.10, Attachment A, "Technical Specifications" (TS) 1.1.7, "Special Requirements for First System in Place." Specifically, TS 1.1.7 requires the submittal of a thermal performance assessment for all DSCs that are loaded with higher heat loads than previously reported.
Registration of Use of Casks to Store Spent Fuel In accordance with 10 CFR 72.212, "Conditions of general license issued under §72.210," paragraph (b)(2), Exelon Generation Company, LLC (EGC) is registering, with the NRC, the use of three casks under the general license to store spent fuel at Limerick Generating Station (LGS). The casks were placed into service with stored spent fuel on July 13, 2018, July 19, 2018 and July 27, 2018. This registration is required to be submitted within 30 days of the cask in-service date. Accordingly, this submittal is due by August 12, 2018.
The attachment to this letter provides this information for the DSCs listed above. This information was obtained using LGS procedure ST-6-114-360-0, "Independent Spent Fuel Storage Installation (ISFSI) Technical Specification Testing." If you have any questions concerning this report, please contact Mr. Robert Dickinson at 610-718-3400.
The following information is provided in accordance with 10 CFR 72.212(b)(2) .
Respectfully, Richard W. Libra Vice President  
Licensee Name: Licensee Address:         Exelon Generation Company, LLC Limerick Generating Station 3146 Sanatoga Road Pottstown, PA 19464 Renewed Reactor License Numbers:         NPF-39 and NPF-85 Reactor Docket Numbers:                 50-352, 50-353 Independent Spent Fuel Storage Installation Docket Number:             72-065 Contact Name and
-Limerick Generating Station Exelon Generation Company, LLC  
 
==Title:==
Robert B. Dickinson Manager - Regulatory Assurance
 
August7,2018 U.S. Nuclear Regulatory Commission Page2 Cask Certificate Number:           1004, Amendment 10 Cask Model Number:                 NUHOMS-61 BTH HSM Model Number:                   HSM*H Service Date:                       July 13, 2018 Cask Identification Number:         LGS-61 BTH1-D-2H-044 HSM Identification Number:          HSM-048 Service Date:                      July 19, 2018 Cask Identification Number:          LGS-61 BTH1-D-2H-045 HSM Identification Number:          HSM-050 Service Date:                      July 27, 2018 Cask Identification Number:        LGS-61 BTH1-D-2H-046 HSM Identification Number:          HSM-052 In addition, this letter provides information for each DSC that is required by Certificate of Compliance (CoC) No. 1004, Amendment No.10, Attachment A, "Technical Specifications" (TS) 1.1.7, "Special Requirements for First System in Place." Specifically, TS 1.1.7 requires the submittal of a thermal performance assessment for all DSCs that are loaded with higher heat loads than previously reported.
The attachment to this letter provides this information for the DSCs listed above. This information was obtained using LGS procedure ST-6-114-360-0, "Independent Spent Fuel Storage Installation (ISFSI)
Technical Specification Testing."
If you have any questions concerning this report, please contact Mr. Robert Dickinson at 610-718-3400.
Respectfully,
    ~
Richard W. Libra Vice President - Limerick Generating Station Exelon Generation Company, LLC


==Attachment:==
==Attachment:==
Thermal Performance Assessment Data, Limerick Generating Station, Independent Spent Fuel Storage Installation, 2018 Dry Cask Storage Campaign cc:    Administrator Region 1 - USNRC USNRC Senior Resident Inspector, LGS NRC Project Manager, NRA - Limerick Generating Station (LGS)
Decommissioning Branch Chief - NAC Region I R.R. Janati, Commonwealth of Pennsylvania


Thermal Performance Assessment Data, Limerick Generating Station, Independent Spent Fuel Storage Installation, 2018 Dry Cask Storage Campaign cc: Administrator Region 1 -USNRC USNRC Senior Resident Inspector, LGS NRC Project Manager, NRA -Limerick Generating Station (LGS) Decommissioning Branch Chief -NAC Region I R.R. Janati, Commonwealth of Pennsylvania Attachment Thermal Performance Assessment Data Limerick Generating Station Independent Spent Fuel Storage Installation 2017 Dry Cask Storage Campaign Dry Storage Canister Number LGS-61 BTH-1-D-2H-044 Horizontal Storage Module Number HSM-048 Maximum Allowable Heat Load 19.40kW Actual Loaded Heat Load 14.25 kW Calculated Temperature Rise 45.0° F Measured Temperature Rise 17.1° F Dry Storage Canister Number LGS-61 BTH-1-D-2H-045 Horizontal Storage Module Number HSM-050 Maximum Allowable Heat Load 19.40kW Actual Loaded Heat Load 15.51 kW Calculated Temperature Rise 47.0° F Measured Temperature Rise 23.5° F Dry Storage Canister Number LGS-61 BTH-1-D-2H-046 Horizontal Storage Module Number HSM-052 Maximum Allowable Heat Load 19.40kW Actual Loaded Heat Load 14.99 kW Calculated Temperature Rise 45.0° F Measured Temperature Rise 30.6° F}}
Attachment Thermal Performance Assessment Data Limerick Generating Station Independent Spent Fuel Storage Installation 2017 Dry Cask Storage Campaign Dry Storage Canister Number       LGS-61 BTH-1-D-2H-044 Horizontal Storage Module Number             HSM-048 Maximum Allowable Heat Load                 19.40kW Actual Loaded Heat Load                 14.25 kW Calculated Temperature Rise                 45.0° F Measured Temperature Rise                 17.1 ° F Dry Storage Canister Number         LGS-61 BTH-1-D-2H-045 Horizontal Storage Module Number             HSM-050 Maximum Allowable Heat Load                 19.40kW Actual Loaded Heat Load                 15.51 kW Calculated Temperature Rise                 47.0° F Measured Temperature Rise                 23.5° F
~
Dry Storage Canister Number         LGS-61 BTH-1-D-2H-046 Horizontal Storage Module Number             HSM-052 Maximum Allowable Heat Load               19.40kW Actual Loaded Heat Load                 14.99 kW Calculated Temperature Rise               45.0° F Measured Temperature Rise                 30.6° F}}

Latest revision as of 10:53, 30 November 2019

Registration of Use of Casks to Store Spent Fuel
ML18219B309
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 08/07/2018
From: Libra R
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
LG-18-089
Download: ML18219B309 (3)


Text

Exelon Generation 10 CFR 72.212 LG-18-089 August7,2018 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352. 50-353. and 72-065

Subject:

Registration of Use of Casks to Store Spent Fuel In accordance with 10 CFR 72.212, "Conditions of general license issued under §72.210," paragraph (b)(2), Exelon Generation Company, LLC (EGC) is registering, with the NRC, the use of three casks under the general license to store spent fuel at Limerick Generating Station (LGS). The casks were placed into service with stored spent fuel on July 13, 2018, July 19, 2018 and July 27, 2018. This registration is required to be submitted within 30 days of the cask in-service date. Accordingly, this submittal is due by August 12, 2018.

The following information is provided in accordance with 10 CFR 72.212(b)(2) .

Licensee Name: Licensee Address: Exelon Generation Company, LLC Limerick Generating Station 3146 Sanatoga Road Pottstown, PA 19464 Renewed Reactor License Numbers: NPF-39 and NPF-85 Reactor Docket Numbers: 50-352, 50-353 Independent Spent Fuel Storage Installation Docket Number: 72-065 Contact Name and

Title:

Robert B. Dickinson Manager - Regulatory Assurance

August7,2018 U.S. Nuclear Regulatory Commission Page2 Cask Certificate Number: 1004, Amendment 10 Cask Model Number: NUHOMS-61 BTH HSM Model Number: HSM*H Service Date: July 13, 2018 Cask Identification Number: LGS-61 BTH1-D-2H-044 HSM Identification Number: HSM-048 Service Date: July 19, 2018 Cask Identification Number: LGS-61 BTH1-D-2H-045 HSM Identification Number: HSM-050 Service Date: July 27, 2018 Cask Identification Number: LGS-61 BTH1-D-2H-046 HSM Identification Number: HSM-052 In addition, this letter provides information for each DSC that is required by Certificate of Compliance (CoC) No. 1004, Amendment No.10, Attachment A, "Technical Specifications" (TS) 1.1.7, "Special Requirements for First System in Place." Specifically, TS 1.1.7 requires the submittal of a thermal performance assessment for all DSCs that are loaded with higher heat loads than previously reported.

The attachment to this letter provides this information for the DSCs listed above. This information was obtained using LGS procedure ST-6-114-360-0, "Independent Spent Fuel Storage Installation (ISFSI)

Technical Specification Testing."

If you have any questions concerning this report, please contact Mr. Robert Dickinson at 610-718-3400.

Respectfully,

~

Richard W. Libra Vice President - Limerick Generating Station Exelon Generation Company, LLC

Attachment:

Thermal Performance Assessment Data, Limerick Generating Station, Independent Spent Fuel Storage Installation, 2018 Dry Cask Storage Campaign cc: Administrator Region 1 - USNRC USNRC Senior Resident Inspector, LGS NRC Project Manager, NRA - Limerick Generating Station (LGS)

Decommissioning Branch Chief - NAC Region I R.R. Janati, Commonwealth of Pennsylvania

Attachment Thermal Performance Assessment Data Limerick Generating Station Independent Spent Fuel Storage Installation 2017 Dry Cask Storage Campaign Dry Storage Canister Number LGS-61 BTH-1-D-2H-044 Horizontal Storage Module Number HSM-048 Maximum Allowable Heat Load 19.40kW Actual Loaded Heat Load 14.25 kW Calculated Temperature Rise 45.0° F Measured Temperature Rise 17.1 ° F Dry Storage Canister Number LGS-61 BTH-1-D-2H-045 Horizontal Storage Module Number HSM-050 Maximum Allowable Heat Load 19.40kW Actual Loaded Heat Load 15.51 kW Calculated Temperature Rise 47.0° F Measured Temperature Rise 23.5° F

~

Dry Storage Canister Number LGS-61 BTH-1-D-2H-046 Horizontal Storage Module Number HSM-052 Maximum Allowable Heat Load 19.40kW Actual Loaded Heat Load 14.99 kW Calculated Temperature Rise 45.0° F Measured Temperature Rise 30.6° F