(8 intermediate revisions by the same user not shown) |
Line 2: |
Line 2: |
| | number = ML12321A357 | | | number = ML12321A357 |
| | issue date = 11/16/2012 | | | issue date = 11/16/2012 |
| | title = Palo Verde Nuclear Generating Station, Units 1,2, and 3 - Email. Request for Additional Information Relief Request No. RR48, Relief from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Sectio | | | title = Email. Request for Additional Information Relief Request No. RR48, Relief from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section Xi.. |
| | author name = Gibson L K | | | author name = Gibson L |
| | author affiliation = NRC/NRR/DORL | | | author affiliation = NRC/NRR/DORL |
| | addressee name = Roehler R | | | addressee name = Roehler R |
Line 9: |
Line 9: |
| | docket = 05000528, 05000529, 05000530 | | | docket = 05000528, 05000529, 05000530 |
| | license number = NPF-041, NPF-051, NPF-074 | | | license number = NPF-041, NPF-051, NPF-074 |
| | contact person = Gibson L K | | | contact person = Gibson L |
| | case reference number = TAC ME9171, TAC ME9172, TAC ME9173 | | | case reference number = TAC ME9171, TAC ME9172, TAC ME9173 |
| | document type = E-Mail, Request for Additional Information (RAI) | | | document type = E-Mail, Request for Additional Information (RAI) |
| | page count = 4 | | | page count = 4 |
| | | project = TAC:ME9171, TAC:ME9172, TAC:ME9173 |
| | | stage = RAI |
| }} | | }} |
| | |
| | =Text= |
| | {{#Wiki_filter:Lent, Susan From: Gibson, Lauren Sent: Friday, November 16, 2012 2:08 PM To: 'Robert. Roehler@aps.com' |
| | |
| | ==Subject:== |
| | Draft RAJ related to Relief Request 48 (TAC Nos. ME9171, ME9172, and ME9173) |
| | Attachments: Draft Request for Additional Information RR48 (TAC Nos. ME9171, ME9172, and ME9173).docx |
| | : Rob, By letter dated August 1, 2012 (Agencywide Documents Access & Management System (ADAMS) Accession No. ML12229A046), the Arizona Public Service Company (APS, the licensee) submitted Relief Request 48 (RR48), requesting relief from the requirements of the American SOciety of Mechanical Engineers (ASME) |
| | Boiler and Pressure Vessel Code (Code) Section XI, Paragraph IWA-4221. The 2001 Edition 2003 Addenda of ASME Section XI, paragraph IWA-4221 requires the use of the construction code for repair and replacement activities. The licensee is proposing to use phased array ultrasonic testing as an alternative to the required radiographic testing. The licensee presented further information at a public meeting on August 30, 2012 (ADAMS Accession No. ML12243A435). |
| | The Nuclear Regulatory Commission (NRC) staff has reviewed the submitted information and determined that the additional information identified in the enclosure is needed to complete its review. |
| | The NRC staff would like a response by December 31, 2012. Please contact me to let me know 1) if you would like to have a clarifying conference call and 2) if this date is acceptable. |
| | Thank you, Lauren Lauren K. Gibson Project Manager Columbia Generating Station Palo Verde Nuclear Generating Station Division of Operating Reactor Licensing U.S. Nuclear Regulatory Commission (301) 415-1056 1 |
| | |
| | DRAFT REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST (RR) 48 REGARDING PHASED ARRAY ULTRASONIC EXAMINATION TECHNIQUES IN LIEU OF RADIOGRAPHY ARIZONA PUBLIC SERVICE COMPANY PALO VERDE NUCLEAR GENERATING STATION UNITS 1, 2, AND 3 DOCKET NOS. 50-528, 50-529, AND 5-530 By letter dated August 1, 2012 (Agencywide Documents Access & Management System (ADAMS) Accession No. ML12229A046), the Arizona Public Service Company (APS, the licensee) submitted Relief Request 48 (RR48), requesting relief from the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (Code) |
| | Section XI, Paragraph IWA-4221. The 2001 Edition 2003 Addenda of ASME Section XI, paragraph IWA-4221 requires the IJse of the construction code for repair and replacement activities. The licensee is proposing to use phased array ultrasonic testing as an alternative to the required radiographic testing. The licensee presented further information at a public meeting on August 30,2012 (ADAMS Accession No. ML12243A435). |
| | The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the submitted information and determined that the following information is needed for the staff to complete its review: |
| | : 1. RR48 describes that, in the near term, the licensee would like to use UT in Lieu of RT for economizer feedwater piping in containment. Please provide a description of the components to be examined in the upcoming outage, including the identification of the components, the inner diameters, thicknesses, and geometries. |
| | : 2. Based on the submittal and the August 30, 2012, public meeting it appears that the specimens described in Attachment 1 have been examined extensively to develop the inspection procedures. Please provide flaw maps showing the true state for several examples of each type of flaw including those found by PT, the ultrasonic results including detection and characterization of flaws, and the radiographic results for these specimens. |
| | : 3. Radiographic testing provides an archival-quality record of the examination that can be stored and interpreted after several decades. Encoded electronic data requires backup and proprietary data formats may become obsolete in the future. How will the ultrasonic results be stored and protected from data loss and future changes in hardware and software that could render the data unreadable? |
| | |
| | -2 |
| | : 4. RR48 states that the proposed alternative will utilize ASME Section III (2001 Edition 2003 Addenda) NC-5300 for acceptance criteria. However. the RT or UT acceptance criteria to be applied is not specified. |
| | : a. Which acceptance standards. NC-5320 "Radiographic Acceptance Standards", |
| | or NC-5330 "Ultrasonic Acceptance Standards" will be used? |
| | : b. Both NC-5320 and NC-5330 require discrimination between defect types. Please describe how discrimination between defect types will be accomplished, including examples of various defects and the ultrasonic features that allow for discrim ination. |
| | : c. If NC-5320 is to be used, discuss and provide data that UT inspection procedures can detect internal root weld conditions (undercut, concavity, etc.) |
| | and characterize them using the acceptance standards in NC-5320. |
| | : d. If NC-5330 is to be used, the NC-5330 Ultrasonic Acceptance Standards require evaluation of responses greater than 20% of the reference level. Will procedures be held to the 20% of reference level standard, or will the procedures have freedom to evaluate indications with lower-amplitude responses? |
| | : 5. The qualification for the personnel who will acquire and analyze the ultrasonic data is described in RR 48, but some important details were not provided. Please answer the following questions about the personnel qualifications: |
| | : a. It was verbally stated at the August 30,2012, public meeting that the procedure demonstration will be open and the personnel tests will be conducted as blind tests. Discuss how the open procedure demonstration and the blind personnel tests will be conducted and why this provides an acceptable level of quality. |
| | : b. In RR48 it is stated: |
| | For detection, the minimum number of flawed and unflawed grading units and associated minimum detection criteria noted in ASME Section XI table VI/I-S2-1 will be met. |
| | Will the false call test acceptance criteria from ASME Code Section XI Appendix VIII Supplement 2 also be required? Please discuss how false calls and or missed calls will affect the qualification of the inspector. (Le., if the operator finds the 5 out of 5 flawed grading units in the mock-up but also has 2 false calls out of 10 unflawed grading units. does the operator receive his qualification?). |
| | : c. Will the blind personnel test require the inspector to correctly determine what types of flaws (porosity, slag, cracks. etc) have been detected? If not, why not? |
| | : d. During the blind personnel qualification, if an inspector detected a crack but misidentified the crack as porosity or slag. would this be considered a successful |
| | |
| | - 3 detection or count as a missed flaw? If it considered a successful detection, how could the NC-5300 acceptance criteria is applied? |
| | : 6. Page 2 of RR48 states that the proposed alternative will utilize ASME Section V, Article 4 (2001 Edition 2003 Addenda), and that the demonstration will document the requirements of Table T-421. There is no Table T-421 in the 2001 Edition 2003 Addenda. Please clarify. Do you mean Table T-422? |
| | : 7. Please provide Reference 14, "EPRI presentation, dated May 2010; Ultrasonic Capability study for reduction of weld repair during the construction-UT Technical Presentation. Jl}} |
Letter Sequence RAI |
---|
|
|
MONTHYEARML12229A0462012-08-0101 August 2012 Relief Request 48 - Proposed Alternative to American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section III - Phased Array Ultrasonic Examination Techniques in Lieu of Radiography Project stage: Request ML12227A8562012-08-17017 August 2012 Notice of Meeting with Arizona Public Service Company to Discuss Relief Request 48 - Alternative to ASME Section III, Phased Array Ultrasonic Examination Techniques for Palo Verde, Units 1, 2, and 3 Project stage: Meeting ML12243A4352012-08-30030 August 2012 8/30/2012 Meeting RR 48 - Phased Array Ultrasonic Examination in Lieu of Radiography Project stage: Request ML12243A4382012-08-30030 August 2012 8/30/2012 Meeting - RR 48 UT Vs Rt Discussion Project stage: Request ML12243A4662012-08-30030 August 2012 Acceptance Review Results Email - for Relief Request Related to Phased Array Ultrasonic Examination Techniques Project stage: Acceptance Review ML12244A2152012-09-20020 September 2012 8/30/2012 Summary of Meeting with Arizona Public Service Company to Discuss Relief Request 48 - Alternative to ASME Section III, Phased Array Ultrasonic Examination Techniques for Palo Verde, Units 1, 2, and 3 Project stage: Meeting ML12321A3572012-11-16016 November 2012 Email. Request for Additional Information Relief Request No. RR48, Relief from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section Xi.. Project stage: RAI ML12328A0482012-11-21021 November 2012 Email, Request for Additional Information Relief Request 48 - ASME, Boiler and Pressure Vessel Code, Section III - Phased Array Ultrasonic Examination Techniques in Lieu of Radiography Project stage: RAI ML13014A0402013-01-0404 January 2013 Response to Request for Additional Information, Relief Request 48 - Proposed Alternative to American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III - Phased Array Ultrasonic Examination.. Project stage: Response to RAI ML13091A1772013-04-12012 April 2013 Relief Request 48 - Alternative to ASME Section III, Phased Array Ultrasonic Exam Techniques in Lieu of Radiography for Remainder of Third 10-Year Inservice Inspection Interval Project stage: Other 2012-08-17
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML24297A6212024-10-22022 October 2024 Request for Additional Information Relief Request (RR) No. 72: Re-Submittal of RR-39/ASME Code X1 IWC-3420, IWA-3300 ML24267A2172024-09-23023 September 2024 (E-Mail) Palo Verde Nuclear Generating Station Units 1, 2, and 3 License Amendment Request to Revise the Technical Specifications 3.5.1 and 3.5.2 Safety Injection Tank Pressure Bands, and to Use GOTHIC Code ML24257A1012024-09-11011 September 2024 Request for Additional Information License Renewal Commitment for AMP of Alloy 600 Components ML24248A2632024-09-0404 September 2024 Acceptance Review of Palo Verde Nuclear Generating Station, Units 1, 2, and 3, Relief Request (RR) No. 71: Re?Submittal of RR?30 ML24242A2812024-08-26026 August 2024 RR72 Acceptance 08/27/24 - La Jr ML24221A2382024-08-0606 August 2024 Change in Estimated Review Schedule and Level of Effort for Palo Verde Units 1, 2, and 3 ML24143A1112024-05-20020 May 2024 Draft 2nd Round Request for RAIs Concerning LAR to Modify LCO for TS 3.5.2, LCO for TS 3.6.5, and Surveillance Requirements 3.5.1.2 and 3.5.2.2 for TS 3.5.1 and TS 3.5.2 ML24138A1112024-05-16016 May 2024 Draft 2nd Round Request for Additional Information (Rais) Concerning License Amendment Request (LAR) to Modify Limiting Condition for Operation (LCO) for Technical Specification (TS) 3.5.2 ML24123A2002024-05-0101 May 2024 (E-Mail) Draft 2nd Round Request for Additional Information Concerning License Amendment Request to Modify Limiting Condition for Operation (LCO) for Technical Specification (TS) 3.5.2, LCO for TS 3.6.5, 3.5.1.2 and 3.5.2.2 for TS 3.5.1, a ML24120A2612024-05-0101 May 2024 Email Acceptance Review of Requested Licensing Action License Renewal Commitment 23A, Alloy 600 Management Program Plan ML24114A2812024-04-19019 April 2024 Request for Additional Information (RAI-10150-R1) ML24103A1222024-04-11011 April 2024 – Acceptance of Requested Licensing Action Re_ License Amendment Request to Revise Technical Specifications 3 ML24011A1002024-01-10010 January 2024 March 2024 Emergency Preparedness Program Inspection - Request for Information ML23334A1612023-11-30030 November 2023 NRR E-mail Capture - Palo Verde 1, 2, and 3 - RAIs Associated with License Renewal Commitment for Pressurizer Surge Line Welds Inspection Program to Manage Environmentally Assisted Fatigue ML23334A0072023-11-29029 November 2023 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Official RAIs for LAR That Revises TSs 3.5.1, SITs - Operating; 3.5.2, SIT Shutdown; 3.6.5, Containment Air Temperature; and SRs for TS 3.5.1, SITs Operating ML23298A1232023-10-25025 October 2023 NRR E-mail Capture - Palo Verde, Unit 1 - RAIs for Relief Request 70, Proposed Alternatives for Pressurizer Lower Shell Temperature Nozzle ML23243B0082023-08-31031 August 2023 NRR E-mail Capture - Action: Opportunity to Review and Comment on a New NRC Information Collection, 10 CFR Part 50.55a, Codes and Standards (3150-XXXX) ML23233A0132023-08-18018 August 2023 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review of License Renewal Commitment for Pressurizer Surge Line Welds Inspection Program to Manage Environmentally Assisted Fatigue ML23220A0512023-08-0303 August 2023 NRR E-mail Capture - Re Palo Verde 1, 2, and 3 - SUNSI Review of UFSAR, Rev. 22 ML23202A0162023-07-20020 July 2023 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review of LAR to Revise TSs 3.5.1, SITs - Operating; 3.5.2, SIT Shutdown; 3.6.5, Containment Air Temperature; and SRs for TS 3.5.1, SITs Operating ML23143A1332023-05-23023 May 2023 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review of LAR Revising TS 3.3.11 to Adopt TSTF-266-A, Rev. 3, Eliminate the Remote Shutdown System Table of Instrumentation and Controls ML23130A0132023-05-10010 May 2023 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review for Authorized Use of Mururoa Supplied Air Suits (Models V4F1 and MTH2) Pursuant to 10 CFR 20.1703 and 10 CFR 20.1705 ML23017A0932023-01-17017 January 2023 NRR E-mail Capture - Palo Verde - Acceptance of License Amendment Request Regarding Adoption of TSTF-107, Separate Control Rods That Are Untrippable Versus Inoperable (L-2022-LLA-0181) ML23013A0632023-01-13013 January 2023 NRR E-mail Capture - Palo Verde Unit 1 -Request for Additional Information - U1R23 Inspection Summary Report for Steam Generator Tubing ML22348A1672022-12-14014 December 2022 March 2023 Emergency Preparedness Exercise Inspection - Request for Information ML22339A2372022-12-0505 December 2022 NRR E-mail Capture - Palo Verde Unit 1 – Request for Additional Information - U1R23 Inspection Summary Report for Steam Generator Tubing ML22173A0682022-06-17017 June 2022 Email Concurrence on SE Input for Columbia Pltr LAR ML22167A1872022-06-16016 June 2022 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Revised Acceptance Review of LAR to Adopt TSTF-567, Add Containment Sump TS to Address GSI-191 Issues ML22136A0922022-05-16016 May 2022 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review of LAR to Adopt TSTF-487-A, Revision 1, Relocate DNB Parameters to the COLR ML22075A1902022-03-16016 March 2022 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review of LAR to Adopt TSTF-567, Add Containment Sump TS to Address GSI-191 Issues ML22055A5842022-02-24024 February 2022 NRR E-mail Capture - Palo Verde, Unit 3 - Final RAIs for 22nd Refueling Outage (Spring 2021) Steam Generator Tube Inservice Inspection Report ML22034A0132022-02-0202 February 2022 NRR E-mail Capture - Palo Verde, Unit 2 - Verbal Approval of RR-69 to Extend Containment Tendon Inspection from 2/8/22 to 6/8/22 ML22032A0312022-01-31031 January 2022 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review for an Exemption Regarding Elimination of Dafas Using RIPE Process ML22025A4012022-01-0303 January 2022 March 2022 Emergency Preparedness Program Inspection - Request for Information ML21333A1982021-11-19019 November 2021 NRC Review of PVNGS Training Needs Analysis and Training Required by Condition I of the Confirmatory Order EA-20-054 ML21306A1882021-10-18018 October 2021 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Second Pre-submittal Meeting for the Proposed Exemption to Eliminate Dafas Using RIPE Process ML21272A0592021-09-28028 September 2021 NRR E-mail Capture - Palo Verde 1, 2, and 3 - SUNSI Review of UFSAR, Rev. 21 ML21264A1352021-09-17017 September 2021 NRR E-mail Capture - Palo Verde 1, 2 and 3 - Acceptance Review of LAR Associated with Permanent Extension of Containment ILRT Frequency to 15 Years (Type a) and CIV Leak Rate Test Frequency to 75 Months (Type C) ML21237A0762021-08-25025 August 2021 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review of RR-67, Request for Alternative Frequency to Containment Unbonded Post-Tensioning System Inservice Inspection ML21228A0082021-08-16016 August 2021 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review of an LAR for Administrative Changes to Technical Specifications ML21228A1042021-08-12012 August 2021 RR-67, Request for Alternative Frequency to Containment Unbonded Post-Tensioning System Inservice Inspection (EPID L-2021-LLR-0050) (Email) ML21237A5172021-08-10010 August 2021 Email to PV Licensee and Palo Verde Nuclear Generating Station, Units 1, 2 and 3 - Notification of Inspection of the Licensees Implementation Industry Initiative Associated with the Open Phase Condition (NRC Bulletin 2012-01) and Request Fo ML21160A1442021-06-0909 June 2021 NRR E-mail Capture - Palo Verde 1 and, 2 - Acceptance Review for Order Approving Transfers of Control of Licenses for Minority Interests Subject to Expiring Leases ML21154A0082021-05-26026 May 2021 NRR E-mail Capture - Palo Verde 1, 2 and 3 - Official RAIs for LAR Associated with Permanent Extension of Containment ILRT Frequency to 15 Years (Type a) and CIV Leak Rate Test Frequency to 75 Months (Type C) ML21146A3342021-05-14014 May 2021 ISFSI - Final Package for an Order Associated with Indirect Transfers of Control of Licenses from Pnm to Avangrid ML21132A2372021-05-12012 May 2021 NRR E-mail Capture - Palo Verde 1, 2, and 3, and ISFSI - Final Package for an Order Associated with Indirect Transfers of Control of Licenses from Pnm to Avangrid ML21103A3632021-04-13013 April 2021 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Acceptance Review for Indirect Transfer of Control of Licenses Pursuant to 10 CFR 50.80 and 10 CFR 72.50 ML21064A2372021-03-0303 March 2021 ISI Request for Information Rls ML21053A0262021-02-22022 February 2021 NRR E-mail Capture - Palo Verde 1, 2 and 3 - Acceptance Review of LAR Associated with Permanent Extension of Containment ILRT Frequency to 15 Years (Type a) and CIV Leak Rate Test Frequency to 75 Months (Type C) ML21043A1462021-02-11011 February 2021 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Official RAI for an Order Associated with Indirect License Transfer from Public Service Company of New Mexico to Avangrid, Inc 2024-09-04
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML24297A6212024-10-22022 October 2024 Request for Additional Information Relief Request (RR) No. 72: Re-Submittal of RR-39/ASME Code X1 IWC-3420, IWA-3300 ML24257A1012024-09-11011 September 2024 Request for Additional Information License Renewal Commitment for AMP of Alloy 600 Components ML24143A1112024-05-20020 May 2024 Draft 2nd Round Request for RAIs Concerning LAR to Modify LCO for TS 3.5.2, LCO for TS 3.6.5, and Surveillance Requirements 3.5.1.2 and 3.5.2.2 for TS 3.5.1 and TS 3.5.2 ML24123A2002024-05-0101 May 2024 (E-Mail) Draft 2nd Round Request for Additional Information Concerning License Amendment Request to Modify Limiting Condition for Operation (LCO) for Technical Specification (TS) 3.5.2, LCO for TS 3.6.5, 3.5.1.2 and 3.5.2.2 for TS 3.5.1, a ML24114A2812024-04-19019 April 2024 Request for Additional Information (RAI-10150-R1) ML24011A1002024-01-10010 January 2024 March 2024 Emergency Preparedness Program Inspection - Request for Information ML23334A1612023-11-30030 November 2023 NRR E-mail Capture - Palo Verde 1, 2, and 3 - RAIs Associated with License Renewal Commitment for Pressurizer Surge Line Welds Inspection Program to Manage Environmentally Assisted Fatigue ML23334A0072023-11-29029 November 2023 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Official RAIs for LAR That Revises TSs 3.5.1, SITs - Operating; 3.5.2, SIT Shutdown; 3.6.5, Containment Air Temperature; and SRs for TS 3.5.1, SITs Operating ML23298A1232023-10-25025 October 2023 NRR E-mail Capture - Palo Verde, Unit 1 - RAIs for Relief Request 70, Proposed Alternatives for Pressurizer Lower Shell Temperature Nozzle ML23031A3392023-01-31031 January 2023 In-service Inspection Request for Information ML23013A0632023-01-13013 January 2023 NRR E-mail Capture - Palo Verde Unit 1 -Request for Additional Information - U1R23 Inspection Summary Report for Steam Generator Tubing ML22348A1672022-12-14014 December 2022 March 2023 Emergency Preparedness Exercise Inspection - Request for Information ML22339A2372022-12-0505 December 2022 NRR E-mail Capture - Palo Verde Unit 1 – Request for Additional Information - U1R23 Inspection Summary Report for Steam Generator Tubing ML22272A3252022-09-29029 September 2022 Licensed Operator Positive Fitness-For-Duty Test Request for Additional Information ML22209A1752022-07-28028 July 2022 Inservice Inspection Request for Information ML22187A2632022-07-0606 July 2022 Notification of Inspection (NRC IR 05000528/2022004, 05000529/2022004 and 05000530/2022004) and Request for Information ML22067A2292022-03-0202 March 2022 Inservice Inspection Inspection PWR Request for Information ML22055A5842022-02-24024 February 2022 NRR E-mail Capture - Palo Verde, Unit 3 - Final RAIs for 22nd Refueling Outage (Spring 2021) Steam Generator Tube Inservice Inspection Report ML22035A3302022-02-10010 February 2022 Requests for Confirmation of Information for Exemption to Delete Diverse Auxiliary Feedwater Actuation System Based on Risk-Informed Process for Evaluations ML22025A4012022-01-0303 January 2022 March 2022 Emergency Preparedness Program Inspection - Request for Information ML21245A2222021-09-0101 September 2021 Request for Information ML21200A2392021-07-20020 July 2021 Docs Request AC - AA August 2021 ML21154A0082021-05-26026 May 2021 NRR E-mail Capture - Palo Verde 1, 2 and 3 - Official RAIs for LAR Associated with Permanent Extension of Containment ILRT Frequency to 15 Years (Type a) and CIV Leak Rate Test Frequency to 75 Months (Type C) ML21064A2372021-03-0303 March 2021 ISI Request for Information Rls ML21042B9692021-02-18018 February 2021 Notification of NRC Design Bases Assurance Inspection and Initial Request for Information ML21043A1462021-02-11011 February 2021 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Official RAI for an Order Associated with Indirect License Transfer from Public Service Company of New Mexico to Avangrid, Inc ML21023A0212021-01-13013 January 2021 PVNGS PI&R Request for Information RA ML21011A1972021-01-12012 January 2021 Unit 2, and Unit 3 - Notification of an NRC Fire Protection Baseline Inspection (NRC Inspection Report 05000528/2021012, 05000529/2021012 and 05000530/2021012) and Request for Information ML20227A0992020-08-14014 August 2020 Licensed Operator Positive Fitness-For-Duty Test Request for Additional Information ML20118D1362020-04-28028 April 2020 Licensed Operator Positive Fitness-For-Duty Test Request for Additional Information ML20049A0992020-02-14014 February 2020 Notification of Cyber Security Inspection (NRC Inspection Report 05000528/2020401; 05000529/2020401; and 05000530/2020401) and Request for Information ML20049A0252020-02-12012 February 2020 NRR E-mail Capture - Palo Verde Nuclear Generating Station, Unit 1 - Official RAIs for License Amendment Request Associated with Changes to Emergency Plan Staffing Requirements ML20021A3172020-01-21021 January 2020 NRR E-mail Capture - Palo Verde Nuclear Generating Station, Unit 1 - Official RAIs for Relief Request 64, Impractical Examinations for the Third 10-Year ISI Interval ML19317D0782019-11-13013 November 2019 NRR E-mail Capture - Palo Verde 1 - Requests for Additional Information on Unit 1 21st Refueling Outage Steam Generator Tube Inspection Report ML19234A3202019-08-29029 August 2019 Redacted - Request for Additional Information for Amendment and Exemption Request to Support the Implementation of Framatome High Thermal Performance Fuel (EPID L-2018-LLA-0194; EPID L-2018-LLE-0010) ML19155A1842019-05-30030 May 2019 NRR E-mail Capture - Palo Verde Nuclear Generating Station, Unit 3 - Mvib Official RAIs for RR-63, Impractical Examinations for the Third 10-Year ISI Interval ML19095A6552019-04-0404 April 2019 NRR E-mail Capture - Palo Verde Nuclear Generating Station, Unit 3 - Mphb Official RAIs for RR-63, Impractical Examinations for the Third 10-Year ISI Interval ML19044A7342019-02-13013 February 2019 NRR E-mail Capture - Palo Verde1, 2, and 3 - Official Requests for Additional Information for RR 62, Third and Fourth 10-Year ISI Intervals, Proposed Alternative - Pressurizer Heat Sleeve Repairs ML19008A3612019-01-0808 January 2019 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Official RAIs for LAR Associated with Response Time Testing of Pressure Transmitters ML18341A0252018-12-0303 December 2018 Notification of NRC Design Bases Assurance Inspection (Teams)(05000528/2019011, 05000529/2019011, and 05000530/2019011) and Initial Request for Information ML18271A0392018-10-0202 October 2018 Non Proprietary - Supplemental Information Needed for Acceptance of Requested License Amendments and Exemptions Implementation of Framatome High Thermal Performance Fuel (Epids L-2018-LLA-0194 and L-2018-LLE-0010) ML18221A5102018-08-23023 August 2018 Request for Additional Information License Amendment Request to Adopt Risk-Informed Completion Times (CAC Nos. MF6576, MF6577, and MF6578; EPID: L-2015-LLA-0001) ML18229A3132018-08-17017 August 2018 NRR E-mail Capture - Request for Additional Information Relief Request 58: Impractical Examinations for the Third 10-Year Inservice Inspection Interval Arizona Public Service Company Palo Verde Nuclear Generation Station, Unit 2 - Second Se ML18227A8672018-08-15015 August 2018 NRR E-mail Capture - Request for Additional Information Relief Request 58: Impractical Examinations for the Third 10-Year Inservice Inspection Interval Arizona Public Service Company Palo Verde Nuclear Generation Station, Unit 2 ML18124A0112018-05-0303 May 2018 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Official Eeob RAIs for TSTF-505 (4b) LAR (CAC Nos. MF6576, MF6577, and MF6578; EPID L-2015-LLA-0001) ML18099A0072018-04-0606 April 2018 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Official RAIs for 10 CFR 50.69 LAR (CAC Nos. MF9971, MF9972, and MF9973; EPID L-2017-LLA-0276) ML18094B1122018-04-0404 April 2018 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Final RAIs for TSTF-505 (Initiative 4b) LAR (CAC Nos. MF6576, MF6577, and MF6578: EPID L-2015-LLA-0001) ML18066A7032018-03-0707 March 2018 Notification of Nrc Design Bases Assurance Inspection (Programs) 05000528/2018011, 05000529/2018011, and 05000530/2018011 Initial Request for Information ML17248A0162017-08-31031 August 2017 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Final RAI for RRs PRR-03, PRR-04 and PRR-05, Pump Testing ML17107A0052017-04-14014 April 2017 NRR E-mail Capture - Palo Verde 1, 2, and 3 - Ngf LAR and Exemption RAIs (CAC Nos. MF8076 to MF8081) 2024-09-11
[Table view] |
Text
Lent, Susan From: Gibson, Lauren Sent: Friday, November 16, 2012 2:08 PM To: 'Robert. Roehler@aps.com'
Subject:
Draft RAJ related to Relief Request 48 (TAC Nos. ME9171, ME9172, and ME9173)
Attachments: Draft Request for Additional Information RR48 (TAC Nos. ME9171, ME9172, and ME9173).docx
- Rob, By letter dated August 1, 2012 (Agencywide Documents Access & Management System (ADAMS) Accession No. ML12229A046), the Arizona Public Service Company (APS, the licensee) submitted Relief Request 48 (RR48), requesting relief from the requirements of the American SOciety of Mechanical Engineers (ASME)
Boiler and Pressure Vessel Code (Code)Section XI, Paragraph IWA-4221. The 2001 Edition 2003 Addenda of ASME Section XI, paragraph IWA-4221 requires the use of the construction code for repair and replacement activities. The licensee is proposing to use phased array ultrasonic testing as an alternative to the required radiographic testing. The licensee presented further information at a public meeting on August 30, 2012 (ADAMS Accession No. ML12243A435).
The Nuclear Regulatory Commission (NRC) staff has reviewed the submitted information and determined that the additional information identified in the enclosure is needed to complete its review.
The NRC staff would like a response by December 31, 2012. Please contact me to let me know 1) if you would like to have a clarifying conference call and 2) if this date is acceptable.
Thank you, Lauren Lauren K. Gibson Project Manager Columbia Generating Station Palo Verde Nuclear Generating Station Division of Operating Reactor Licensing U.S. Nuclear Regulatory Commission (301) 415-1056 1
DRAFT REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST (RR) 48 REGARDING PHASED ARRAY ULTRASONIC EXAMINATION TECHNIQUES IN LIEU OF RADIOGRAPHY ARIZONA PUBLIC SERVICE COMPANY PALO VERDE NUCLEAR GENERATING STATION UNITS 1, 2, AND 3 DOCKET NOS. 50-528, 50-529, AND 5-530 By letter dated August 1, 2012 (Agencywide Documents Access & Management System (ADAMS) Accession No. ML12229A046), the Arizona Public Service Company (APS, the licensee) submitted Relief Request 48 (RR48), requesting relief from the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (Code)
Section XI, Paragraph IWA-4221. The 2001 Edition 2003 Addenda of ASME Section XI, paragraph IWA-4221 requires the IJse of the construction code for repair and replacement activities. The licensee is proposing to use phased array ultrasonic testing as an alternative to the required radiographic testing. The licensee presented further information at a public meeting on August 30,2012 (ADAMS Accession No. ML12243A435).
The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the submitted information and determined that the following information is needed for the staff to complete its review:
- 1. RR48 describes that, in the near term, the licensee would like to use UT in Lieu of RT for economizer feedwater piping in containment. Please provide a description of the components to be examined in the upcoming outage, including the identification of the components, the inner diameters, thicknesses, and geometries.
- 2. Based on the submittal and the August 30, 2012, public meeting it appears that the specimens described in Attachment 1 have been examined extensively to develop the inspection procedures. Please provide flaw maps showing the true state for several examples of each type of flaw including those found by PT, the ultrasonic results including detection and characterization of flaws, and the radiographic results for these specimens.
- 3. Radiographic testing provides an archival-quality record of the examination that can be stored and interpreted after several decades. Encoded electronic data requires backup and proprietary data formats may become obsolete in the future. How will the ultrasonic results be stored and protected from data loss and future changes in hardware and software that could render the data unreadable?
-2
- 4. RR48 states that the proposed alternative will utilize ASME Section III (2001 Edition 2003 Addenda) NC-5300 for acceptance criteria. However. the RT or UT acceptance criteria to be applied is not specified.
- a. Which acceptance standards. NC-5320 "Radiographic Acceptance Standards",
or NC-5330 "Ultrasonic Acceptance Standards" will be used?
- b. Both NC-5320 and NC-5330 require discrimination between defect types. Please describe how discrimination between defect types will be accomplished, including examples of various defects and the ultrasonic features that allow for discrim ination.
- c. If NC-5320 is to be used, discuss and provide data that UT inspection procedures can detect internal root weld conditions (undercut, concavity, etc.)
and characterize them using the acceptance standards in NC-5320.
- d. If NC-5330 is to be used, the NC-5330 Ultrasonic Acceptance Standards require evaluation of responses greater than 20% of the reference level. Will procedures be held to the 20% of reference level standard, or will the procedures have freedom to evaluate indications with lower-amplitude responses?
- 5. The qualification for the personnel who will acquire and analyze the ultrasonic data is described in RR 48, but some important details were not provided. Please answer the following questions about the personnel qualifications:
- a. It was verbally stated at the August 30,2012, public meeting that the procedure demonstration will be open and the personnel tests will be conducted as blind tests. Discuss how the open procedure demonstration and the blind personnel tests will be conducted and why this provides an acceptable level of quality.
- b. In RR48 it is stated:
For detection, the minimum number of flawed and unflawed grading units and associated minimum detection criteria noted in ASME Section XI table VI/I-S2-1 will be met.
Will the false call test acceptance criteria from ASME Code Section XI Appendix VIII Supplement 2 also be required? Please discuss how false calls and or missed calls will affect the qualification of the inspector. (Le., if the operator finds the 5 out of 5 flawed grading units in the mock-up but also has 2 false calls out of 10 unflawed grading units. does the operator receive his qualification?).
- c. Will the blind personnel test require the inspector to correctly determine what types of flaws (porosity, slag, cracks. etc) have been detected? If not, why not?
- d. During the blind personnel qualification, if an inspector detected a crack but misidentified the crack as porosity or slag. would this be considered a successful
- 3 detection or count as a missed flaw? If it considered a successful detection, how could the NC-5300 acceptance criteria is applied?
- 6. Page 2 of RR48 states that the proposed alternative will utilize ASME Section V, Article 4 (2001 Edition 2003 Addenda), and that the demonstration will document the requirements of Table T-421. There is no Table T-421 in the 2001 Edition 2003 Addenda. Please clarify. Do you mean Table T-422?
- 7. Please provide Reference 14, "EPRI presentation, dated May 2010; Ultrasonic Capability study for reduction of weld repair during the construction-UT Technical Presentation. Jl