{{#Wiki_filter:Mirion Technologies (Canberra), Inc.
{{#Wiki_filter:Mirion Technologies (Canberra), Inc.                   Toll Free 800-243-4422 800 Research Parkway                                    Tel. 203-238-2351 Meriden, Connecticut 06450                              www.canberra.com December 6, 2018 U.S Nuclear Regulatory Commission Washington, DC 20555-0001 MSHD.Resource@nrc.gov
800 Research Parkway Meriden, Connecticut  06450 Toll Free 800
-243-4422 Tel. 203-238-2351 www.canberra.com December 6, 2018 U.S Nuclear Regulatory Commission Washington, DC 20555
-0001 MSHD.Resource@nrc.gov


==Subject:==
==Subject:==
10 CFR Part 21.21 Report   Name and address of the individual or individuals informing the Commission.
10 CFR Part 21.21 Report
Shelia Webb Stacey Kohan Vice President QA Manager Mirion Technologies (Canberra), Inc.
* Name and address of the individual or individuals informing the Commission.
Mirion Technologies (Canberra), Inc.
Shelia Webb                                             Stacey Kohan Vice President                                         QA Manager Mirion Technologies (Canberra), Inc.                   Mirion Technologies (Canberra), Inc.
800 Research Parkway 800 Research Parkway Meriden, CT 06450 Meriden, CT 06450 swebb@mirion.com skohan@mirion.com 203-639-2000     203-639-2000   Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains a defect.
800 Research Parkway                                   800 Research Parkway Meriden, CT 06450                                       Meriden, CT 06450 swebb@mirion.com                                       skohan@mirion.com 203-639-2000                                           203-639-2000
US Facilities
* Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains a defect.
:   Entergy ANO  
US Facilities:             Entergy ANO - Control Room Emergency Ventilation System, CREV (ADM616)
- Control Room Emergency Ventilation System, CREV (ADM616)
TVA Browns Ferry - Control Room Emergency Ventilation, CREV (ADM606)
TVA Browns Ferry  
OPPD Ft. Calhoun - RM051 Containment Atmosphere Monitor, RM052 Containment Atmosphere Vent Gas monitor, RM062 Aux Bldg Stack - Gas Basic Components:           CR600CIP Customer Interface Panel connected to ADM606 Rackmount Ratemeter, and in ADM616 Wallmount Ratemeter Containing:
- Control Room Emergency Ventilation, CREV (ADM60
Potter & Bromfield Product Code R10-E1-X2-J1.0K, Cradle Style Relay with C-Form contacts Used in Radiation Monitoring Systems to output Alarm and Fault States
: 6) OPPD Ft. Calhoun  
* Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.
- RM051 Containment Atmosphere Monitor, RM052 Containment Atmosphere Vent Gas monitor, RM062 Aux Bldg Stack  
- Gas     Basic Components:
CR600CIP Customer Interface Panel connected to ADM606 Rackmount Ratemeter, and in ADM616 Wallmount Ratemeter Containing:
Potter & Bromfield Product Code R10
-E1-X2-J1.0K, Cradle Style Relay with C
-Form contacts Used in Radiation Monitoring Systems to output Alarm and Fault States Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.
Mirion Technologies (Canberra), Inc.
Mirion Technologies (Canberra), Inc.
(fka Canberra Industries, Inc.)
(fka Canberra Industries, Inc.)
800 Research Parkway Meriden, CT 06450 Nature of the defect or failure to comply and the safety hazard which is created or would be created by such defect or failure to comply.
800 Research Parkway Meriden, CT 06450
These relays exhibited chatter in a de-energized state during a seismic test. If the relay is normally de
* Nature of the defect or failure to comply and the safety hazard which is created or would be created by such defect or failure to comply.
-energized and chatters during a seismic event, it may actuate or indicate incorrectly.
These relays exhibited chatter in a de-energized state during a seismic test. If the relay is normally de-energized and chatters during a seismic event, it may actuate or indicate incorrectly.
The date on which the information of such defect or failure to comply was obtained.
* The date on which the information of such defect or failure to comply was obtained.
Non-conformance was determined on: July 5, 2018, Technical Evaluation to determine failure to comply was concluded on 5 December 2018.
Non-conformance was determined on: July 5, 2018, Technical Evaluation to determine failure to comply was concluded on 5 December 2018.
In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part.
* In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part.


Mirion Technologies (Canberra), Inc.
Mirion Technologies (Canberra), Inc.                     Toll Free 800-243-4422 800 Research Parkway                                    Tel. 203-238-2351 Meriden, Connecticut 06450                              www.canberra.com
800 Research Parkway Meriden, Connecticut  06450 Toll Free 800
`
-243-4422 Tel. 203-238-2351 www.canberra.com
These relays are used in a normally de-energized state in five, safety-related, radiation monitoring system, installations in the United States, at Entergy ANO, at TVA Browns Ferry, and OPPD Ft. Calhoun.
  ` These relays are used in a normally de
US Facilities:             Entergy ANO - Control Room Emergency Ventilation System, CREV (ADM616)
-energized state in five, safety
TVA Browns Ferry - Control Room Emergency Ventilation, CREV (ADM606)
-related, radiation monitoring system, installations in the United States, at Entergy ANO, at TVA Browns Ferry, and OPPD Ft. Calhoun.
OPPD Ft. Calhoun - RM051 Containment Atmosphere Monitor, RM052 Containment Atmosphere Vent Gas monitor, RM062 Aux Bldg Stack - Gas
US Facilities
* The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.
:   Entergy ANO  
        -   Review previous Radiation Monitoring (Safety Related) projects to determine the extent and possible impact
- Control Room Emergency Ventilation System, CREV (ADM616)
            - Complete, Mirion (Canberra), Reference Product Performance Report, PPR 3883
TVA Browns Ferry  
        -   Review monitor interconnection with plant systems to identify specifically the relays and plants connections to assess impact - Each Site, 6 months, June 28, 2019
- Control Room Emergency Ventilation, CREV (ADM606)
        -   Develop mitigations which could include using alternative relay output (CR600TP termination panel for ADM606) and/or change rate meter firmware to normally energize relay - Mirion (Canberra), 6 months, June 28, 2019
OPPD Ft. Calhoun  
* Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.
- RM051 Containment Atmosphere Monitor, RM052 Containment Atmosphere Vent Gas monitor, RM062 Aux Bldg Stack  
- Gas   The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.
  - Review previous Radiation Monitoring (Safety Related) projects to determine the extent and possible impact  
- Complete, Mirion (Canberra), Reference Product Performance Report, PPR 3883
- Review monitor interconnection with plant systems to identify specifically the relays and plants connections to assess impact  
- Each Site, 6 months, June 28, 2019
- Develop mitigations which could include using alternative relay output (CR600TP termination panel for ADM606) and/or change rate meter firmware to normally energize relay  
- Mirion (Canberra), 6 months, June 28, 2019   Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.
The ADM606 and ADM616 are only being supplied as replacement parts to extend service life of installed monitors.
The ADM606 and ADM616 are only being supplied as replacement parts to extend service life of installed monitors.
In the case of an early site permit, the entities to which an early site permit was transferred.
* In the case of an early site permit, the entities to which an early site permit was transferred.
Not applicable
Not applicable
 
: Regards, Stacey                Digitally signed by Stacey Kohan DN: cn=Stacey Kohan, o=Mirion Technologies (Canberra), Inc., ou, Kohan                  email=skohan@mirion.com, c=US Date: 2018.12.06 16:16:53 -05'00' Shelia Webb                               Stacey Kohan Cc:     TVA Nuclear Nuclear Assurance and Licensing Attn: Manager, Operating Experience 1101 Market St.
Regards,   Shelia Webb Stacey Kohan
Chattanooga, TN 37402-2801 Fleet Manager, Corrective Action and Operating Experience Entergy Nuclear Operations 1340 Echelon Parkway M-ECH-25 Fleet_OE@Entergy.com,  
 
Cc:   TVA Nuclear Nuclear Assurance and Licensing Attn: Manager, Operating Experience 1101 Market St. Chattanooga, TN 37402
-2801 Fleet Manager, Corrective Action and Operating Experience Entergy Nuclear Operations 1340 Echelon Parkway M-ECH-25 Fleet_OE@Entergy.com,  


==Subject:==
==Subject:==
Fleet Manager, Corrective Action & Operating Experience: Part 21
Fleet Manager, Corrective Action & Operating Experience: Part 21 Manager - Nuclear Licensing Fort Calhoun Nuclear Station Omaha Public Power District 9610 Power Lane Blair, NE 68008


Manager - Nuclear Licensing Fort Calhoun Nuclear Station Omaha Public Power District 9610 Power Lane Blair, NE  68008
Mirion Technologies (Canberra), Inc. Toll Free 800-243-4422 800 Research Parkway                Tel. 203-238-2351 Meriden, Connecticut 06450          www.canberra.com FCSLicensingMgr@oppd.com}}
 
Mirion Technologies (Canberra), Inc.
800 Research Parkway Meriden, Connecticut  06450 Toll Free 800
-243-4422 Tel. 203-238-2351 www.canberra.com FCSLicensingMgr@oppd.com}}

Latest revision as of 10:33, 20 October 2019

Mirion Technologies - 10 CFR Part 21.21 Report Re Relays Defect
ML18341A247
Person / Time
Site: Browns Ferry, Fort Calhoun  Tennessee Valley Authority icon.png
Issue date: 12/06/2018
From: Kohan S, Webb S
Mirion Technologies (Canberra)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML18341A247 (3)


Text

Mirion Technologies (Canberra), Inc. Toll Free 800-243-4422 800 Research Parkway Tel. 203-238-2351 Meriden, Connecticut 06450 www.canberra.com December 6, 2018 U.S Nuclear Regulatory Commission Washington, DC 20555-0001 MSHD.Resource@nrc.gov

Subject:

10 CFR Part 21.21 Report

  • Name and address of the individual or individuals informing the Commission.

Shelia Webb Stacey Kohan Vice President QA Manager Mirion Technologies (Canberra), Inc. Mirion Technologies (Canberra), Inc.

800 Research Parkway 800 Research Parkway Meriden, CT 06450 Meriden, CT 06450 swebb@mirion.com skohan@mirion.com 203-639-2000 203-639-2000

  • Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains a defect.

US Facilities: Entergy ANO - Control Room Emergency Ventilation System, CREV (ADM616)

TVA Browns Ferry - Control Room Emergency Ventilation, CREV (ADM606)

OPPD Ft. Calhoun - RM051 Containment Atmosphere Monitor, RM052 Containment Atmosphere Vent Gas monitor, RM062 Aux Bldg Stack - Gas Basic Components: CR600CIP Customer Interface Panel connected to ADM606 Rackmount Ratemeter, and in ADM616 Wallmount Ratemeter Containing:

Potter & Bromfield Product Code R10-E1-X2-J1.0K, Cradle Style Relay with C-Form contacts Used in Radiation Monitoring Systems to output Alarm and Fault States

  • Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.

Mirion Technologies (Canberra), Inc.

(fka Canberra Industries, Inc.)

800 Research Parkway Meriden, CT 06450

  • Nature of the defect or failure to comply and the safety hazard which is created or would be created by such defect or failure to comply.

These relays exhibited chatter in a de-energized state during a seismic test. If the relay is normally de-energized and chatters during a seismic event, it may actuate or indicate incorrectly.

  • The date on which the information of such defect or failure to comply was obtained.

Non-conformance was determined on: July 5, 2018, Technical Evaluation to determine failure to comply was concluded on 5 December 2018.

  • In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part.

Mirion Technologies (Canberra), Inc. Toll Free 800-243-4422 800 Research Parkway Tel. 203-238-2351 Meriden, Connecticut 06450 www.canberra.com

`

These relays are used in a normally de-energized state in five, safety-related, radiation monitoring system, installations in the United States, at Entergy ANO, at TVA Browns Ferry, and OPPD Ft. Calhoun.

US Facilities: Entergy ANO - Control Room Emergency Ventilation System, CREV (ADM616)

TVA Browns Ferry - Control Room Emergency Ventilation, CREV (ADM606)

OPPD Ft. Calhoun - RM051 Containment Atmosphere Monitor, RM052 Containment Atmosphere Vent Gas monitor, RM062 Aux Bldg Stack - Gas

  • The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.

- Review previous Radiation Monitoring (Safety Related) projects to determine the extent and possible impact

- Complete, Mirion (Canberra), Reference Product Performance Report, PPR 3883

- Review monitor interconnection with plant systems to identify specifically the relays and plants connections to assess impact - Each Site, 6 months, June 28, 2019

- Develop mitigations which could include using alternative relay output (CR600TP termination panel for ADM606) and/or change rate meter firmware to normally energize relay - Mirion (Canberra), 6 months, June 28, 2019

  • Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.

The ADM606 and ADM616 are only being supplied as replacement parts to extend service life of installed monitors.

  • In the case of an early site permit, the entities to which an early site permit was transferred.

Not applicable

Regards, Stacey Digitally signed by Stacey Kohan DN: cn=Stacey Kohan, o=Mirion Technologies (Canberra), Inc., ou, Kohan email=skohan@mirion.com, c=US Date: 2018.12.06 16:16:53 -05'00' Shelia Webb Stacey Kohan Cc: TVA Nuclear Nuclear Assurance and Licensing Attn: Manager, Operating Experience 1101 Market St.

Chattanooga, TN 37402-2801 Fleet Manager, Corrective Action and Operating Experience Entergy Nuclear Operations 1340 Echelon Parkway M-ECH-25 Fleet_OE@Entergy.com,

Subject:

Fleet Manager, Corrective Action & Operating Experience: Part 21 Manager - Nuclear Licensing Fort Calhoun Nuclear Station Omaha Public Power District 9610 Power Lane Blair, NE 68008

Mirion Technologies (Canberra), Inc. Toll Free 800-243-4422 800 Research Parkway Tel. 203-238-2351 Meriden, Connecticut 06450 www.canberra.com FCSLicensingMgr@oppd.com