=Text=
=Text=
{{#Wiki_filter:
{{#Wiki_filter:January 24, 2012
[[Issue date::January 24, 2012]]


Dr. Director of University of Florida Training Reactor Nuclear and Radiological Engineering Department P. O. Box 11830 University of Florida Gainesville, FL 32611
==SUBJECT:==
 
UNIVERSITY OF FLORIDA - NRC ROUTINE INSPECTION REPORT NO. 50-083/2012-201
SUBJECT: UNIVERSITY OF FLORIDA - NRC ROUTINE INSPECTION REPORT NO. 50-083/2012-201


==Dear Dr. Jordan:==
==Dear Dr. Jordan:==
Line 30: Line 28:
Based on the results of this inspection, no safety concern or noncompliance of requirements was identified. No response to this letter is required In accordance with Title 10 of the Code of Federal Regulations Part 2.390, "Public inspections, exemptions, and requests for withholding" a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (Agencywide Document Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room) http://www.nrc.gov/reading-rm/adams.html. Should you have any questions concerning this inspection, please contact Jack Donohue at 301-452-1950 or electronic mail at Jack.Donohue@nrc.gov.
Based on the results of this inspection, no safety concern or noncompliance of requirements was identified. No response to this letter is required In accordance with Title 10 of the Code of Federal Regulations Part 2.390, "Public inspections, exemptions, and requests for withholding" a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (Agencywide Document Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room) http://www.nrc.gov/reading-rm/adams.html. Should you have any questions concerning this inspection, please contact Jack Donohue at 301-452-1950 or electronic mail at Jack.Donohue@nrc.gov.


Sincerely,/RA/ Johnny H. Eads, Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-083 License No. R-56  
Sincerely,
 
/RA/ Johnny H. Eads, Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-083 License No. R-56 Enclosure: NRC Inspection Report No. 50-083/2012-201 cc w/encl: See next page University of Florida Docket No. 50-083 Dr. David Hintenlang, Chairman Nuclear & Radiological Engineering Department University of Florida 202 Nuclear Sciences Center PO Box 118300 Gainesville, FL 32601-8300 Administrator Department of Environmental Regulation Power Plant of Siting Section State of Florida 2600 Blair Stone Road Tallahassee, FL 32301 State Planning and Development Clearinghouse Office of Planning and Budgeting Executive Office of the Governor The Capitol Building Tallahassee, FL 32301 Chief, Bureau of Radiation Control Department of Health 4052 Bald Cypress Way Tallahassee, FL 32399-1741 Test, Research and Training Reactor Newsletter Director of Nuclear Facilities University of Florida 202 Nuclear Science Building Gainesville, FL 32611-8300  
===Enclosure:===
NRC Inspection Report No. 50-083/2012-201 cc w/encl: See next page University of Florida Docket No. 50-083 Dr. David Hintenlang, Chairman Nuclear & Radiological Engineering Department University of Florida 202 Nuclear Sciences Center PO Box 118300 Gainesville, FL 32601-8300 Administrator Department of Environmental Regulation Power Plant of Siting Section State of Florida 2600 Blair Stone Road Tallahassee, FL 32301 State Planning and Development Clearinghouse Office of Planning and Budgeting Executive Office of the Governor The Capitol Building Tallahassee, FL 32301 Chief, Bureau of Radiation Control Department of Health 4052 Bald Cypress Way Tallahassee, FL 32399-1741 Test, Research and Training Reactor Newsletter Director of Nuclear Facilities University of Florida 202 Nuclear Science Building Gainesville, FL 32611-8300  


Brian Shea, Reactor Manager Nuclear & Radiological Engineering Dept 202 Nuclear Sciences Center P.O. Box 118300 University of Florida Gainesville, FL 32611-8300 Dean Cammy Abernathy University of Florida College of Engineering PO Box 116550 Gainesville, FL 32611  
Brian Shea, Reactor Manager Nuclear & Radiological Engineering Dept 202 Nuclear Sciences Center P.O. Box 118300 University of Florida Gainesville, FL 32611-8300 Dean Cammy Abernathy University of Florida College of Engineering PO Box 116550 Gainesville, FL 32611  

Revision as of 02:55, 29 June 2019

IR 05000083-12-201 on January 30 Thru February 2, 2012 at the University of Florida - NRC Routine Inspection No. 50-083-12-201
ML120540013
Person / Time
Site: 05000083
Issue date: 02/24/2012
From: Johnny Eads
Research and Test Reactors Branch B
To: Jordan K
Univ of Florida
Donohue, J N, NRR/DPR, 4153163
References
IR-12-201
Download: ML120540013 (17)


Text

January 24, 2012

SUBJECT:

UNIVERSITY OF FLORIDA - NRC ROUTINE INSPECTION REPORT NO. 50-083/2012-201

Dear Dr. Jordan:

The U.S. Nuclear Regulatory Commission (NRC) conducted a routine inspection on January 30 to February 2, 2012 at your University of Florida Test Reactor Facility (Inspection Report No. 50-083/2012-201). During the inspection, the NRC staff examined activities conducted under your license as they relate to public health and safety and with the conditions of your license. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress.

Based on the results of this inspection, no safety concern or noncompliance of requirements was identified. No response to this letter is required In accordance with Title 10 of the Code of Federal Regulations Part 2.390, "Public inspections, exemptions, and requests for withholding" a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (Agencywide Document Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room) http://www.nrc.gov/reading-rm/adams.html. Should you have any questions concerning this inspection, please contact Jack Donohue at 301-452-1950 or electronic mail at Jack.Donohue@nrc.gov.

Sincerely,

/RA/ Johnny H. Eads, Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-083 License No. R-56 Enclosure: NRC Inspection Report No. 50-083/2012-201 cc w/encl: See next page University of Florida Docket No.50-083 Dr. David Hintenlang, Chairman Nuclear & Radiological Engineering Department University of Florida 202 Nuclear Sciences Center PO Box 118300 Gainesville, FL 32601-8300 Administrator Department of Environmental Regulation Power Plant of Siting Section State of Florida 2600 Blair Stone Road Tallahassee, FL 32301 State Planning and Development Clearinghouse Office of Planning and Budgeting Executive Office of the Governor The Capitol Building Tallahassee, FL 32301 Chief, Bureau of Radiation Control Department of Health 4052 Bald Cypress Way Tallahassee, FL 32399-1741 Test, Research and Training Reactor Newsletter Director of Nuclear Facilities University of Florida 202 Nuclear Science Building Gainesville, FL 32611-8300

Brian Shea, Reactor Manager Nuclear & Radiological Engineering Dept 202 Nuclear Sciences Center P.O. Box 118300 University of Florida Gainesville, FL 32611-8300 Dean Cammy Abernathy University of Florida College of Engineering PO Box 116550 Gainesville, FL 32611

January 14, 2012 D