ML13008A047: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 2: Line 2:
| number = ML13008A047
| number = ML13008A047
| issue date = 10/31/2012
| issue date = 10/31/2012
| title = Beaver Valley Power Station, Unit 2, Near-Term Task Force Recommendation 2.3 Seismic Walkdown Report, Appendix C, Area Walk-by Checklists, Page C-1 Through Sheet 78 of 123
| title = Near-Term Task Force Recommendation 2.3 Seismic Walkdown Report, Appendix C, Area Walk-by Checklists, Page C-1 Through Sheet 78 of 123
| author name = Beigi F, Guerra E, Lucarelli B A, Reny D
| author name = Beigi F, Guerra E, Lucarelli B A, Reny D
| author affiliation = ABS Consulting
| author affiliation = ABS Consulting

Latest revision as of 01:23, 18 March 2019

Near-Term Task Force Recommendation 2.3 Seismic Walkdown Report, Appendix C, Area Walk-by Checklists, Page C-1 Through Sheet 78 of 123
ML13008A047
Person / Time
Site: Beaver Valley
Issue date: 10/31/2012
From: Beigi F, Guerra E, Lucarelli B A, Reny D
ABS Consulting
To:
Office of Nuclear Reactor Regulation, FirstEnergy Nuclear Operating Co
References
L-12-283
Download: ML13008A047 (79)


Text

APPENDIX C AREA WALK-BY CHECKLISTS (AWCs)C-1

[L ------ Paul C. Rizzo Associates, Inc.Sheet I of 123 StatusQ N U Area Walk-By Checklist (AWC)Room 105 Floor El. 545 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Anchorage for cover plate of E31-4 does not have nuts, see Photo 2.Concern has been judged not to represent an adverse coniditon regarding the component's seismic performance.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: 1) P42-1 2) P58-1 3) C3 1-4 L--% Paul C. Rizzo Associates, Inc........ .~%LL ,'Sheet 2 of 123 Status N U Area Walk-By Checklist (AWC)Room 105 Floor El. 545 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A x Y N U N/A x Y N U N/A x Temporary scaffolding in area appears to be adequately restrained See Photo 3.8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: Pump E198-1, Tanks T198-I, T199-1, Piping: Aux steam, comp cooling, cont spray, decay heat, demin water, fire protection, high press inject, prim water, makeup water, service water, reactor coolant Evaluated by: Eddie M. Guerra BrinL .LucarelIt Date: 7/25/2012 Date: 7/25/2012 vl--- Paul C. Rizzo Associates, Inc.Sheet 3 of 123 Statusv N U Area Walk-By Checklist (AWC)Room 105 Floor El. 545 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I General View of Room 105 Area 1-% q Paul C. Rizzo Associates, Inc." L S Sheet 4 of 123 Statuso~ N U Area Walk-By Checklist (AWC)Room 105 Supporting Photos (continued):

Floor El. 545 Bldg.AUXB Photo 2 Missing Nuts on Cover of E31-4 Photo 3 Temporary Scaffolding Restrained L Y Paul C. Rizzo Associates, Inc.LNINUPI RS& VIPC..tIIAN!ý Sheet 5 of 123 Statuso N U Area Walk-By Checklist (AWC)Room 113 Floor El. 545 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x I I I Y N U N/A x I I 71 Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: 1) E27-1 2) E27-2 3) CC 1469

[ Paul C. Rizzo Associates, Inc.

CL'ON 'LIPSI', Sheet 6 of 123 Statuso N U Area Walk-By Checklist (AWC)Room 113 Floor El. 545 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: NO No flood sources identified in area.Evaluated by: Eddie M. Guerra BiriianA.

Luca~rell._

Date: 7/25/2012 Date: 7/25/2012 IXYPaul C. Rizzo Asisociates, Inc.ENUINIMS & CONLL I'*IS Sheet 7 of 123 Status(7V N U Area Walk-By Checklist (AWC)Room 113 Floor El. 545 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I General View of Room 113 IlIQ Paul C. Rizzo Associates, Inc.&N, .6i LOS 1A'Sheet 8 of 123 StatusQ N U Area Walk-By Checklist (AWC)Room 122 Floor El. 570'3.0625" Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Masonry walls identified in area.Walls identified as 1157, 1167, and 1187.Walls 1157 and 1167 have been seismically analyzed per NRC IE Bulletin 80-11 (Ref VBWO3-BOOI-009, Rev 5 and VBWO3-BO0-010, Rev 8). Wall 1187 is exempt since no safety-related equipment is in the vicinity of the wall.Related equipment on SWEL for this area: 1) SFI616A 41rY Paul C. Rizzo Associates, Inc.NI(N-1 I RSi Sheet 9 of 123 Status(o~

N U Area Walk-By Checklist (AWC)Room 122 Floor El. 570'3.0625" Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic K interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic K interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Temporary scaffolding installed in area, judged not likely to cause interaction.

8. Have you looked for and found no other seismic conditions that could E adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: NO No flood sources identified in area.Evaluated by:_ _ _ _ 44 Date: Eddie M. Guerra Date: B;rian A.i Lucarel 7/25/2012 7/25/2012 C. Rizzo Associates, Inc.LNUINLERS

& CON'SULIAMIS Sheet 10 of 123 Status(7D N U Area Walk-By Checklist (AWC)Room 122 Floor El. 570'3.0625" Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo 1 General View of Room 122

~XQ Paul C. Rizzo Associates, Inc.1Lt INL I 1 11 NL I XVj1 Sheet 11 of 123 Status: 0 N U Area Walk-By Checklist (AWC)Room 208 Floor El. 565 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported It isjudged that since the vertical acceleration at this location is less than 1g, it is unlikely for the extinguisher to fall or cause significant interaction with nearby equipment.

Related equipment on SWEL for this area: I) FTHP3C 2) IA-636 3) hp2c 4) hp3c Paul C. Rizzo Associates, Inc.INUNLLRb & LCtNSULIAN*I Sheet 12 of 123 Status~y)N U Area Walk-By Checklist (AWC)Room 208 Floor El. 565 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A x Y N U N/A x Y N U N/A x A dolly was found unrestrained in the area. Since the dolly had restraining chains on it, it was judged that it is temporarily located at the position found in the room and will be returned to its storage location and tied when work is done. Also, no sensitive equipment found in the vicinity of this dolly. Y N U 8. Have you looked for and found no other seismic conditions that could X adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are Coolers E26-1,E26-2, Tank T139-1, Piping: Aux system, borated water, component cooling, cont spray, decay heat, demin water, fire Evaluated by: ,_ _ __---_Eddie M. Guerra Date: 7/25/2012 Date: 7/25/2012 I Paul C. Rizzo A-sociates, Inc.l (LNOINURNý k

Sheet 13 of 123 Status: N U Area Walk-By Checklist (AWC)Room 208 Floor El. 565 Bldg.AUXB Other supporting or relevant documents and photos (if any): Yhoto i General View of Room 208 Photo 2 Unrestrained Dolly in Area L Y Paul C. Rizzo Associates, Inc.UNINLEMI:

&,4'd,:UL All S Sheet 14 of 123 Status:N U Area Walk-By Checklist (AWC)Room 209 Floor El. 565 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x I I I I Fire extinguisher is mounted on the wall and is not laterally supported It is judged that since the vertical acceleration at this location is less than 1g, it is unlikely for the extinguisher to fall or cause significant interaction with nearby equipment.

Related equipment on SWEL for this area: i) BWIO I'IC Paul C. Rizzo Associates, Inc.LNU( IRS & COINSLI AN SN Sheet 15 of 123 Status:@ N U Area Walk-By Checklist (AWC)Room 209 Floor El. 565 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic L interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic i interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic EI interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Nuclear filter cask cart unrestrained adjacent to components.

There are no sensitive equipment in the zone of influence of this cart and it is judged OK. It is also noted that this cart appear to be temporarily in the area.8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x IIII Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: Hydrogen Piping to Make Up Tank No concerns identified regarding fire sources. The poeyiat wrrcues M atren tre

'Itqimng'.o Make Up Tank Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are B"WST Heater E34, Piping: Aux steam, borated water, comp cooling, domestic water, Duratek, demin water, fire protection, high pressure injection, main steam, makeup, primary water, spent fuel clean waste Evaluated by: Date: 7/25/2012 Eddie M. Guerra Date: BanA. I Ii 7/25/2012 LKY Paul C. Rizzo Associates, Inc.t\ NMEIRS & WN CULANINj Sheet 16 of 123 Status:Q N U Area Walk-By Checklist (AWC)Room 209 Floor El. 565 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo 1 General View of Room 209 Photo 2 Nuclear Filter Cask Cart Not Restrained L Y Paul C. Rizzo Associates, Inc.Sheet 17 of 123 Status:ON U Area Walk-By Checklist (AWC)Room 225 Floor El. 565 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.!. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Block wall close to P372B.Walls identified as 2047. 2427, and 2437.All walls have been seismically analyzed per NRC IE Bulletin 80-11 (Ref VBWIO-BO01-058, Rev 3 and VBWIO-BO01-059, Rev 1).Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x VBWO6-BOO0-028, Rev 4, Related equipment on SWEL for this area: i) P372B 2) DI-19B

'41:' Paul C. Rizzo Associates, Inc.UNU.INLLRS I CONSLL1ANIS Sheet 18 of 123 Status: N U Area Walk-By Checklist (AWC)Room 225 Floor El. 565 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

RP cart and dolly not restrained.

In a subsequent visit to his area on the next day, it was observed that this cart was properly restrained

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x I _j Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: Lighting Transformer No concerns identified regarding fire sources. The potential ignition sources in the area are Lighting Transformer Flooding Sources: No concerns identified regarding flood sources. The potential flood sources in the area are Lube oil coolers E188-1, E188-2, E212-1, E212-2, cooler E36, Accumulators T6406 &T6407, Piping: Comp Cooling, Core flood, makeup, reactor coolant Evaluated by:y : _Eddie M. Guerra Brian:A. Lucýarell Date: 7/25/2012 Date: 7/25/2012 L~QPaul C. Rizzo Associates, Inc.LNI I t S 1Iý 4. IINSSLI1ASI

.Sheet 19 of 123 Status:6DN U Area Walk-By Checklist (AWC)Room 225 Floor El. 565 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I Photo 2 Dolly Not Restrained RP Cart Not Restrained L Y Paul C. Rizzo Associates, Inc.Sheet 20 of 123 Status: 3N U Area Walk-By Checklist (AWC)Room 236 Floor El. 565 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported It is judged that since the vertical acceleration at this location is less than lg, it is unlikelyfor the extinguisher to fall or cause significant interaction with nearby equipment.

Masonry wall in room, see Photo 2.Walls identified as 2317, 2327, 2337, and 2347. All walls seismically analyzed per NRC IE Bulletin 80-11 (Ref VBWO9-BOO0-049, Rev 8, VBWO9-BOO0-050, Rev 4, VBWO9-BOOI-051, Rev 10 and VBWO9-BOOI-052, Rev 3).Related equipment on SWEL for this area: 1) hp2b LXQ Paul C. Rizzo Associates, Inc.LNUIl"tL RS, & V0%NSL'L I ASP.ýSheet 21 of 123 Status: 0 N U Area Walk-By Checklist (AWC)Room 236 Floor El. 565 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are Tank T139-2, Piping: Auxfeedwater, component cooling, containment spray, decay heat, fire protection, high pressure injection, main steam, makeup, prim water, reactor coolant spent fuel, service water Evaluated by: ,_____..,____-__

Eddie M. Guerra Date: 7/25/2012 Date: 7/25/2012

~Q Paul C. Rizzo Aisociates, Inc.LUS(INtIRN

& COMULLAAMS Sheet 22 of 123 Status: ~N U Area Walk-By Checklist (AWC)Room 236 Floor El. 565 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I Photo 2 General View of Room 236 Masonry Wall LXQ Paul C. Rizzo Associates, Inc.LNGINt t & C.- US;Ll AVI 4 Sheet 23 of 123 N U Area Walk-By Checklist (AWC)Room 237 Floor El. 565 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: 1)AFI9 2) PSL 106C 3) PSL4928A 4) FV6452 5) P14-1 6) MS5889A 7) C73-1 I~IQPaul C. Rizzo Associates, Inc.LNVIN11M I CONt FAVI', Sheet 24 of 123 Status: 0 N U Area Walk-By Checklist (AWC)Room 237 Floor El. 565 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are Oil cooler E194-1, condensate tank T21 7, Piping: Aux. feedwater, condensate, turbine plant cooling water, domestic water, main steam, Service water.Evaluated by: Eddie M. Guerra Br-,ian A. Lucarell.Date: 7/25/2012 Date: 7/25/2012

~Q Paul C. Rizzo Associates, Inc.LV \I IR'Ltk & CO-~L Ii WVA'Sheet 25 of 123 Status: 0 N U Area Walk-By Checklist (AWC)Room 237 Floor El. 565 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I Photo 2 General View of Room 237 General View of Room 237 WKQ Paul C. Rizzo Associates, Inc.t~L & C.tflCW'L1' L .*t S Sheet 26 of 123 Status: N U Area Walk-By Checklist (AWC)Room 238 Floor El. 565 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported.

It is judged that since the vertical acceleration at this location is less than 1g, it is unlikely for the extinguisher to fall or cause significant interaction with nearby equipment.

Related equipment on SWEL for this area: 1) P14-2 2) FV6451 Ilh---- Paul C. Rizzo Associates, Inc.LM: 1N1I&S. ON-LL I ANP Sheet 27 of 123 Status:c N U Area Walk-By Checklist (AWC)Room 238 Floor El. 565 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Scaffolding in area appears to be adequately restrained

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The poten'tidtftoodi s'ources 'in ire -area -are Oll orluters UPA-12, E30, seal water cooler T218, condensate tank T218, Piping: Aux. feedwater, condensate, turbine plant cooling water, domestic water, main steam, service water Evaluated by:_ _ _ _Date: Eddie M. Guerra_ _ _ Date: Brian !A.Luare~lli 7/25/2012 7/25/2012 L Y Paul C. Rizzo A.sociates, Inc.LNUMlM&:R WMONSL1 Ah'I Sheet 28 of 123 Status:& 0N U Area Walk-By Checklist (AWC)Room 238 Floor El. 565 Bldg.AUXB Other supporting or relevant documents and photos (if any): General View of Room 238 L~'YPaul C. Rizzo Associates, 111C.tLt INUI&R. OIJNCLItA\Th Sheet 29 of 123 Status: 0 N U Area Walk-By Checklist (AWC)Room PT Floor El. 565 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: 1) I0 LXYPaul C. Rizzo Associates, Inc.kNKANttRS

& VONSLIANIS Sheet 30 of 123 Status: 0 N U Area Walk-By Checklist (AWC)Room PT Floor El. 565 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A x Y N U N/A x Y N U N/A x Construction debris in area. Not likely to cause adverse interaction.

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: Hydrogen Piping to Make Up Tank No concerns identified regarding fire sources. The potential ignition sources in the area are Hydrogen Piping to Make Up Tank Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are Borated water storage tank TIO, Piping: Borated water, Decay Heat, High Pressuer Injection Evaluated by:>42L__Eddie M. Guerra BinA. Cucarellh Date: 7/25/2012 Date: 7/25/2012 L~LYPaul C. Rizzo Associates, Inc.tU( 'INPS & WtNNULIMMNI Sheet 31 of 123 Status:(0 N U Area Walk-By Checklist (AWC)Room PT Floor El. 565 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I General View of PT LKY Paul C. Rizzo Associates, Inc.LNO NLLRSý 4,MULUAll N Sheet 32 of 123 Statud ) N U Area Walk-By Checklist (AWC)Room 303 Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Y N U N/A x I I I I 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Small gap (-1/4") between grout and anchor plate. Judged to be acceptable, see Photo 2.CS16, a checkvalve, has several nuts with what appears to be less than adequate thread engagement in that the threads do not extend beyond the nut, they are flush.Concluded that is acceptable per procedure DB-MM-09266.

Y N U N/A 2. Does anchorage of equipment in the area appear to be free of significant X degraded conditions?

Y N U N/A 3. Based on a visual inspection from the floor, do the cable/conduit X raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y N U N/A 4. Does it appear that the area is free of potentially adverse seismic spatial X interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Related equipment on SWEL for this area: 1) AF608 2) CS1530 Paul C. Rizzo Associates.

Inc.Sheet 33 of 123 Statud'Vý N U Area Walk-By Checklist (AWC)Room 303 Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Hydrogen line in the area is well supported.

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are Moisture Accumulation tank T216, Piping: Aux. feedwater, Containment Spray, Fire Protection, Feedwater Evaluated by: Eddie M. Guerra Brian A. Lucarell Date: 7/25/2012 Date: 7/25/2012 LC~ Paul C. Rizzo Associates, Inc.LN'V.t UtRS4ý CONýVIt1 NII Sheet 34 of 123N U Area Walk-By Checklist (AWC)Room 303 Floor El. 585 Bldg.AUXB Other supporti Photo 1 General View of Room 303 Gap Between Grout and Anchor Plate I Paul C. Rizzo Associates, Inc.Lt.N(INLLRS CW VNAIUANI'i Sheet 35 of 123 Statud__ýN U Area Walk-By Checklist (AWC)Room 304 Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: I)EllB 2) YE2B 3) BW21 4) SF11 I~IQ Paul C. Rizzo Associates.

Inc.LNIUMENUR VONISULTANI Sheet 36 of 123 Status:0~

N U Area Walk-By Checklist (AWC)Room 304 Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Degraded insulation observed on domestic water line. Judged not to be a concern.Comments (Additional pages may be added as necessary)

Fire Sources: Transformer above L3701, Transformer above L4801 No concerns identified regarding fire sources. The potential ignition sources in the area are Transformer above L3701, Transformer above L4801 Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are Abandoned tank E72, Piping: Aux. Feedwater, Aux. Steam, Borated Water, Domestic water, Duratek, Demin water, fire protection, main feedwater, makeup, primary water, SPF pool cooling, Evaluated by: 4 ;Eddie M. Guerra Brian A. Lucarell.Date: 7/25/2012 Date: 7/25/2012 Ir QPalC.Rzo soca_,Ic L9:3b- 14C LPuILfl. CON. RizoAmoit e Ic Sheet 37 of 123 Status:& N U Area Walk-By Checklist (AWC)Room 304 Floor El. 585 Bldg.AUXB Other supporting or relevant documents and photos (if any): General View of Room 304 L~'Y Paul C. Rizzo A~sociates, Inc.tl*UINLIMb C(ONUUTANJ'I Sheet 38 of 123 StatudY N U Area Walk-By Checklist (AWC)Room 312 Floor El. 590'6" Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A x I I I I Two anchor bolts missing from electrical conduit support near R3701 rack, see Photo 2.An additional inspection was performed and it was noted that the base support is welded to the angle in the floor for the floor plug. Therefore, this finding is judged not to present a significant seismic concern.2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Minor corrosion noted in anchorage supporting sensor panel, see Photo 3.Deemed not a significant degraded condition.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y N U N/A x I I I I Y N U N/A x Y N U N/A x I 4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Masonry wall in area, see Photo 1. Check seismic adequacy.Walls identified as 3227, 3247, 3257, 3267, 3277, 3297, 3357, 3367, 3417, 3427.Wall 3427 is exempt. All other walls have been seismically analyzed Related equipment on SWEL for this area: 1) FIS 1612 2) SF47 3) DHIO1 X Y Paul C. Rizzo Associates, Inc.LI:RS &. CONSLUL1ANI, Sheet 39 of 123 Statud-3)

N U Area Walk-By Checklist (AWC)Room 312 Floor El. 590'6" Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A x Y N U N/A x Y N U N/A x Cart with gas cannisters loosely restrained to wall, see Photo 4.Judged not a concern since straps and chains will keep cannisters in place thus no direct contact with nearby equipment is expected.Y N U x I I I 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are HX E23-1, E23-2, Pumps P247, P248, P249 & P250, Piping: Component cooling, Decay heat, domestic water, demin water, spent fuel Evaluated by: Eddie M. Guerra Biria A. L7ucarelli Date: 7/25/2012 Date: 7/25/2012 L 4Q Paul C. Rizzo Associates, Inc.LNANM VOKNULL1A!.

Sheet 40 of 123 Statud'V' N U Area Walk-By Checklist (AWC)Room 312 Floor El. 590'6" Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I Photo 2 General View of Room 312 Missing Anchor Bolts Showing Masonry Walls L~~ Paul C. Rizzo Associates.

Inc.Sheet 41 of 123 Statud*_*'

N U Area Walk-By Checklist (AWC)Supporting Photos (continued):

Photo 3 Photo 4 Minor Corrosion on Cart Containing Gas Canisters Anchor Plate Loosely Restrained 4<- Paul C. Rizzo Associates.

Inc.Sheet 42 of 123 Status:Y Y U Area Walk-By Checklist (AWC)Room 314 Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Nut missing on conduit, see Photo 1.Condition report issued: CR-2012-10920

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: 1) RC3701 L~Y Paul C. Rizzo Am~ociaes.

linc.LNGINLLR$

CON$StL[ANI" Sheet 43 of 123 Status: Y 0 U Area Walk-By Checklist (AWC)Room 314 Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Hydrogen line in this area is well supported.

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are Piping: Auxfeedwater, Aux. steam, Component Cooling, Core Flood, Containment Spray, Decay Heat Removal, Fire Protection, High Evaluated by:y : _Eddie M. Guerra Býri~an A. uae Date: 7/25/2012 Date: 7/25/2012 I[?Q Paul C. Rizzo Associates, Inc.ENGLNULRS

& NNSUTLI'ANI Sheet 44 of 123 Status: Y QU Area Walk-By Checklist (AWC)Room 314 Floor El. 585 Bldg.AUXB Other supporting or relevant documents and photos (if any): Nut Missing on Conduit I~QPaul C. Rizzo Ass;ociates, tile.Sheet 45 of 123 Status N U Area Walk-By Checklist (AWC)Room 318 Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported.

It is judged that since the vertical acceleration at this location is less than 1g, it is unlikely for the extinguisher to fall or cause significant interaction with nearby equipment.

Masonry walls identified as 308D, 309D, 310D, 31 ID, and 338D.All walls have been seismically analyzed per NRC IE Bulletin 80-11 (Ref VBW12-BO01-068, Rev 3, I'BWI3-BOOI-069, Rev 3, VBW13-BO01-070, Rev 3, VBWI3-BO01-071, Rev 8 and VBWI9-BOO1-093, Rev 5).Related equipment on SWEL for this area: I) F108-1 2) EI2B 3)C!1-1 4) K5-1 5) TE-5329 6) C3615 7) DA-3783 IPaul C. Rizzo Associates, Inc.LNMUS C'7ýLIAMNI Sheet 46 of 123 Status N U Area Walk-By Checklist (AWC)Room 318 Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The poirnetidt 1tzods :n lire area are [YG !1taeke't'vuJter E10-1, DG Oil Cooler E94-1, DG Jacket Water T121-1, Piping: Component Cooling, Domestic water, Diesel Fuel Oil, Demin Water, Fire Protection Evaluated by:: _Eddie M. Guerra Brian A. Lucarell Date: 7/25/2012 Date: 7/25/2012

~Q Paul C. Rizzo A~sociates, Inc.MACt USILL&, CCXML JASIS Sheet 47 of 123 Statuso N U Area Walk-By Checklist (AWC)Room 318 Floor El. 585 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo 1 Masonry Wall L Y Paul C. Rizzo Associates, Inc.LEtINttRS

&. AXI'S Sheet 48 of 123 Status("výN U Area Walk-By Checklist (AWC)Room 319 Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported It is judged that since the vertical acceleration at this location is less than 1g, it is unlikelyfor the extinguisher tofall or cause significant interaction with nearby equipment.

Block walls 304D and 307D identified in room.All walls have been seismically analyzed per NRC IE Bulletin 80-11 (Ref VBWI2-BOOI-064, Rev 8, and VBWI2-BOO-067, Rev 7).Related equipment on SWEL for this area: I) YFI 2) K5-2 3) C25-3 I~QPaul C. Rizzo Associates, lite.I~~ ~~~. IW 4:ýL;NLLIAS&

CM*SL II A lLS Sheet 49 of 123 Statuso 'N U Area Walk-By Checklist (AWC)Room 319 Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A L x I I Y N U N/A x Y N U N/A x Y N U x T --T-Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources-No concerns identified regarding flood sources. The purertr tn'tre -rea -are E2TU.aek t&tC zsdter EIO-2, DG Lube oil HX E94-2, DG Jacket water T121-2, Piping: Component cooling, Domestic water, Diesel Fuel oil, demin water, fire protection Evaluated by: Eddie M. Guerra Birian A. Luc7arell Date: 7/25/2012 Date: 7/25/2012 L~Q Paul C. Rizzo Associates, Inc.UN IULLKS& CON9JLT1ANI Sheet 50 of 123 Status(o N U Area Walk-By Checklist (AWC)Room 319 Floor El. 585 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo 1 General View of Room 319 rlQl Paul C. Rizzo Associates, late.I '4 Lxt;INLRS& (I)NN( LIANI Sheet 51 of 123 Statuso N U Area Walk-By Checklist (AWC)Room 321A Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Masonry wall, see Photo 1.Walls identified as 305D and 306D. Both have been seismically analyzed All walls have been seismically analyzed per NRC IF Bulletin 80-11 (Ref VBW12-BOOI-065, Rev 5, and VBWI2-BO01-066, Rev 6).Related equipment on SWEL for this area: I) LT-2787 2) T46-1 LKY~ Paul C. Rizzo Associates, Inc.L"tX.NEEKS, COSL LIANIN Sheet 52 of 123 Statuso N U Area Walk-By Checklist (AWC)Room 321A Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x Comments (Additional pages may be added as necessary)

Fire Sources: EMERGENCY DIESEL GENERA TOR DAY TANK ]-I No concerns identified regarding fire sources. The potential ignition sources in the area are EMERGENCY DIESEL GENERATOR DAY TANK I-I Flooding Sources: No concerns identified regarding flood somurcs. The po erthdflovd wuurces -tn Yhe ureu -are VMG ftyhz-dtOi lo-1, Piping: Diesel Fuel Oil, Fire Protection Evaluated by: Date: 7/25/2012 Eddie M. Guerra Date: 7/25/2012 LKYPaul C. Rizzo Asoiociates, Inc.Sheet 53 of 123 Statusrv"ýN U Area Walk-By Checklist (AWC)Room 321A Floor El. 585 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I Masonry Wall I -I 'R Paul C. Rizzo Associates, Inc.LNGWM &t~t4 CONSULTZA\1I Sheet 54 of 123 Status(o)

N U Area Walk-By Checklist (AWC)Room 323 Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported.

It is judged that since the vertical acceleration at this location is less than ig, it is unlikely for the extinguisher to fall or cause significant interaction with nearby equipment.

Related equipment on SWEL for this area: 1) DI L~Y Paul C. Rizzo Associates,, 111c.'.1 INtLU I t('N'AI AVINX Sheet 55 of 123 Statuso N U Area Walk-By Checklist (AWC)Room 323 Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A x Y N U N/A x Y N U N/A x Supply cabinet left open, see Photo 2.However this cabinet is anchored andjudged not to cause any interaction with nearby equipment.

Y N U x 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: NO No flood sources identified in area.Evaluated by: Eddie M. Guerra Brian A Lucarelh ,l Date: 7/25/2012 Date: 7/25/2012

'or- Paul C. Rizzo Ass~ociate~s, Inc.LNULMtLShý CVNSL'LIANI$

Sheet 56 of 123 Statuso N U Area Walk-By Checklist (AWC)Room 323 Floor El. 585 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I Photo 2 General View of Room 323 Supply Cabinet Left Open Paul C. Rizzo Associates, In1c.1St INLLRS& CONSL1AWItNI Sheet 57 of 123 Statusrvi:ýN U Area Walk-By Checklist (AWC)Room 325 Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported.

It is judged that since the vertical acceleration at this location is less than Ig, it is unlikely for the extinguisher to fall or cause significant interaction with nearby equipment.

Flourescent lights ovserved above sensitive equipment.

Flourescent lights jusdged as OK based on testing of lights performed for IPEEE.Related equipment on SWEL for this area: 1) C3645 2)C1 I[Q Paul C. Rizzo Associates, Inc.

ANk"I Sheet 58 of 123 StatusON U Area Walk-By Checklist (AWC)Room 325 Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: Screens per FAQ 07-0031, 30 kVA No concerns identified regarding fire sources. The potential ignition sources in the area are Screens per FAQ 07-0031; 30 kVA Flooding Sources: NO No flood sources identified in area.Evaluated by: --Eddie M. Guerra BrianA .L1ucareliAh Date: 7/25/2012 Date: 7/25/2012

~Q1 Paul C. Rizzo Asisociates, Inc.LINULIAS & CON'LL I A" S Sheet 59 of 123 Statusqr N U Area Walk-By Checklist (AWC)Room 325 Floor El. 585 Bldg.AUXB Other supporting or relevant documents and photos (if any): General View of Room 325 DOD Paul C. Rizzo Associates, Inc.L.M C ')SL L1'A 1 Sheet 60 of 123 StatusON U Area Walk-By Checklist (AWC)Room 328 Floor El. 585 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Need to verify anchorage of E 22-1 (welded?)Anchorage confirmed to be consistent with design documentation.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported It is judged that since the vertical acceleration at this location is less than 1g, it is unlikely for the extinguisher to fall or cause significant interaction with nearby equipment.

Masonry wall adjacent to E22-1, see Photo 1.Walls identified as 3307, 3347, 3397, and 3407. All walls have been seismically analyzed per NRC IE Bulletin 80-11 (Ref VBWJ 7-BOO1-088, Rev 6, VBWI8-BOO0-090, Rev 3 VBWJ9-BOO0-094, Rev 5 and VBW19-BOOI-095, Rev 10).Related equipment on SWEL for this area: 1) E22-1 2) E22-2 3) P43-2 Y Paul C. Rizzo As..ociates, Inc.ILN*U[NU:RS

& CONNULIALlbA' Sheet 61 of 123 Status N U Area Walk-By Checklist (AWC)Room 328 Floor El. 585 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Scaffolding and stepladders in area appear to be properly restrained

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are CCW HX E22-1, E22-2, E23-3, Chem pot feeder T13, Piping: Fire Protection, Component Cooling, Demin water, service water.Evaluated by: _ __ .. _ _-" Eddie M. Guerra-Bian A. Lucarell Date: 7/25/2012 Date: 7/25/2012 I~IQPaul C. Rizzo Asiociates, Inc.LNULNUtRS I CONIL'L1ANP Sheet 62 of 123 StatusoN U Area Walk-By Checklist (AWC)Room 328 Floor El. 585 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo 1 General View of Room 328 Masonry Wall Adjacent to Heat Exchange E22-1 QPaul C. Rizzo Associates, Inc.t'Ut"ILLK V.LON'% L. A' I. 1 I Sheet 63 of 123 Status:QN U Area Walk-By Checklist (AWC)Room 427 Floor El. 603 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported.

It is judged that since the vertical acceleration at this location is less than 1g, it is unlikely for the extinguisher to fall or cause significant interaction with nearby equipment.

Related equipment on SWEL for this area: I) Fl IA I~Q Paul C. Rizzo Associates, Inc.LXINGINUM

.CVNSWLTANSI Sheet 64 of 123 Status: N U Area Walk-By Checklist (AWC)Room 427 Floor El. 603 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A x Y N U N/A x Y N U N/A x Ladder is stored adjacent to MCC and is tied loosely, see Photo 2.Recommended to be tighten but judged not a significant adverse condition.

Y N U x 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

Fire Sources: Transformer Feed to DP4502, 480V Transformer for MCC YF2 No concerns identified regarding fire sources. The potenmiat gntirm 3'rm'rcesin Ylh area utrel"Prangormer tve117 DP4502, 480V Transformer for MCC YF2 Flooding Sources: No concerns identified regarding flood sources. The potentialflood sources in the area are Piping: Main Steam, Fire Protection Evaluated by: ______________

_________Eddie M. Guerra BrinA.Date: 7/25/2012 Date: 7/25/2012 I`IQ Paul C. Rizzo Associates, Inc.LNI'.( XIES COMNLt1 ANIN Sheet 65 of 123 Status:( ( N U Area Walk-By Checklist (AWC)Room 427 Floor El. 603 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I General View of Room 427 Photo 2 Ladder Loosely Tied Adjacent to MCC FII A X Paul C. Rizzo Associates, Inc.LNGINLE1Rt tX)NStLIANIS Sheet 66 of 123 Status:O N U Area Walk-By Checklist (AWC)Room 428 Floor El. 603 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Fire extinguisher is mounted on the wall and is not laterally supported.

It is judged that since the vertical acceleration at this location is less than 1g, it is unlikelyfor the extinguisher to fall or cause significant interaction with nearby equipment.

Masonry walls adjacent to components, see Photo 2.Block walls identified as walls 4016, 4026, 4036, 4046, 4786, 4796, 4886, 4896, and 4906.All walls have been seismically analyzed per NRC IE Bulletin 80-11 (Ref VBW20-BO01-100, Rev 14, VBW21-BOO0-102, Rev 13, VBW25-BOO0-125, Rev 9, VBW25-BOOI-126, Rev 6, VBW27-BO01-135, Rev 19, VBW27-BO01-136, Rev 3 and VBW28-B001-137, Rev 3.Related equipment on SWEL for this area: I) C4606 2) FI2A 3) FD1062 4) D2_ED 5) D2P 6) Y2 7) YV2 9) DBC2P 10) FI 11) D233 12) XDF 1-2 13) C4605 14) D233 15) DBCIPN 17) DCI 18) Y1 8) YV4 16) DBC2PN L~YPaul C. Rizzo Associates, Inc.Sheet 67 of 123 Status: N U Area Walk-By Checklist (AWC)Room 428 Floor El. 603 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Electrical cart and tools unrestrained in room. See Photo 3.These equipment were found to be temporary as the equipment were being serviced 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Door to cabinet DCB-2P observed open. See Photo 4.Judged okay as the equipment was being serviced Comments (Additional pages may be added as necessary)

Fire Sources: No concerns identified regarding fire sources. The potential ignition sources in the area are Power Transformer for Substation F2 &F 1, Transformer for H3602 and "-460)2, Lighting Sationt'YrarnsfrmerConstant V o mge Transformer XY2,Static Voltage Regulator Flooding Sources: NO No flood sources identified in area.Evaluated by: _ -____--__,____

__ ___ _ __ _Eddie M. Guerra Brian A Lucarell Date: 7/25/2012 Date: 7/25/2012 No concerns identified regarding fire sources. The potential ignition sources in the area are Power Transformer for L-- Paul C. Rizzo Associates, Inc.UN L3RS 5. tON'SUUAI1 Sheet 68 of 123 Status:N U Area Walk-By Checklist (AWC)Room 428 Floor El. 603 Bldg.AUXB Other supporting or relevant documents and photos (if any): Photo I General View of Room 428 Photo 2 Masonry Wall Adjacent to Components DCQ Paul C. Rizzo Asisociates, tile.L~tNUL RI& CON'tTIAN I Sheet 69 of 123 Status:cON U Area Walk-By Checklist (AWC)Room 428 Supporting Photos (continued):

Floor El. 603 Bldg.AUXB Photo 3 Photo 4 Unrestrained Work Cart Cabinet DCB-2P Door Left Open L~Q Paul C. Rizzo Ahsociates, Inc.LNU~NUkK & CONSUUAWIS Sheet 70 of 123 Status:N U Area Walk-By Checklist (AWC)Room 428A Floor El. 603 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.I. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Masonry wall adjacent to battery rack.Walls identified as 4016 and 4026, both seismically analyzed per NRC IE Bulletin 80-11 (Ref VBW20-BO01-100, Rev 14).Related equipment on SWEL for this area: 1) 2P 2) 2N 3) C78-2

'4C Paul C. Rizzo Associates, Ine.LX( NLtRS & CO'SALIA tAI Sheet 71 of 123 Status:O N U Area Walk-By Checklist (AWC)Room 428A Floor El. 603 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A x Y N U N/A x Y N U N/A I x Wooden scaffolding was found near battery rack which could represent a potential adverse condition.

Control process confirmed scaffold is temporary and complies with work period 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: NO No flood sources identified in area.Y N U x l I I Evaluated by: Eddie M. Guerra Brian A. Lucarelh Date: 7/25/2012 Date: 7/25/2012 I~Q-Paul C. Rizzo Associates, Inc.Sheet 72 of 123 Status:N U Area Walk-By Checklist (AWC)Room 428A Floor El. 603 Bldg.AUXB Other supporting or relevant documents and photos (if any): General View of Room 428A L~'Y Paul C. Rizzo A~sociates.

Inc.LINL:IRS&11111 AOS~ll I Sheet 73 of 123 Status:O N U Area Walk-By Checklist (AWC)Room 428B Floor El.603 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A I x Y N U N/A x Y N U N/A x Walls in the area identified as 4016 and 4026, both seismically analyzed per NRC IE Bulletin 80-11 (Ref VBW20-BO01-100, Rev 14).Related equipment on SWEL for this area: I) D2N

[Mc Paul C. Rizzo Associates, Inc.L N IN LLIAN V tN St'L VLýq Sheet 74 of 123 Status: N U Area Walk-By Checklist (AWC)Room 428B Floor El. 603 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x Comments (Additional pages may be added as necessary)

Fire Sources: NO No fire sources identified in area.Flooding Sources: NO No flood sources identified in area.Evaluated by:y : Eddie M. Guerra B rianA. Lucýar elI I.Y Date: 7/25/2012 Date: 7/25/2012

`4Y Paul C. Rizzo Associates, Inc.Sheet 75 of 123 Status: )N U Area Walk-By Checklist (AWC)Room 428B Floor El. 603 Bldg.AUXB Other supporting or relevant documents and photos (if any): General View of Room 428B L C Paul C. Rizzo Associates, Inc.LNGINU Sheet 76 of 123 Status:O N U Area Walk-By Checklist (AWC)Room 429 Floor El. 603 Bldg.AUXB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: 1) Y105 2) DIED 3) YRFI 4) El 5) XCEI-I L~Y Paul C. Rizzo Associates, Inc.Sheet 77 of 123 Status:c N U Area Walk-By Checklist (AWC)Room 429 Floor El. 603 Bldg.AUXB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Fire Sources: Power Transformer For Substation E2 & El, Constant Voltage Transformer, Static Voltage Regulator No concerns identified regarding fire sources. The potential ignition sources in the area are Power Transformer For Substation E2 & El, Constant Voltage Transformer, Static Voltage Regulator Flooding Sources: NO No flood sources identified in area.Evaluated by: .Eddie M. Guerra Brian A. Lucarelli Date: 7/25/2012 Date: 7/25/2012 L Y Paul C. Rizzo Associates, Inc.LNUINLERS

& CXWSCLTAN1ý Sheet 78 of 123 Status: cý)N U Area Walk-By Checklist (AWC)Room 429 Floor El. 603 Bldg.AUXB Other supporting or relevant documents and photos (if any): General View of Room 429