Text

...

FENOC FirstEnergy Nuclear Operating Company Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 Richard D. Bologna Site Vice President

_724-682-5234 Fax: 724-643-8069 February 20, 2019 L-19-053 10 CFR 50, Appendix E, Section VI ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Emergency Response Data System Data Point Library Update In accordance with reporting requirement 10 CFR 50, Appendix E, Section Vl.3.a, updates of the Emergency Response Data System (EROS) Data Point Library (DPL) for Beaver Valley Power Station, Unit Nos. 1 and 2 (BV1), (BV2) are provided. The attachment includes the required details of the changes, and the enclosure provides copies of the updated DPL pages.

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Brian D. Kremer, Manager -

Regulatory Compliance, at 724-682-4284.

Richard D. Bologna Site Vice President

Attachment:

Summary of Changes to Data Point Library

Enclosure:

Beaver Valley Power Station EROS Data Point Library, Updated Pages cc:

NRC Region I Administrator NRC Resident Inspector NRC Project Manager (w/o enclosure)

Director BRP/DEP Site BRP/DEP Representative

Reactor Unit DPL Point BV1 WS035SR BV1 WSSOOSR BV1 WD150SR BV1 WDSOOSR BV1 TS150SR BV1 TSSOOSR BV1 XM006 BV1 XM026 BV1 XM051 BV1 XM061 BV1 XM083 BVl XM087 BV1 XR0011 BV1 XR002_1 BV1 XR003 1 BV1 XR004_1 Attachment L-19-053 Summary of Changes to Data Point Library Page 1 of 2 Sullllllary of Changes to Data Point Library Description of Change(s)

Create new point named WS035SR with same fields as XM006.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Create new point named WSSOOSR with same fields as XM026.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Create new point named WD150SR with same fields as XM051.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Create new point named WDSOOSR with same fields as XM061.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Create new point named TS150SR with same fields as XM083.

Date: changed to "01/28/19", Data Feeder: changed to "MET"

~reate new point named TSSOOSR with same fields as XM087.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Data Feeder: changed from "ARERAS" to "UNIT1".

Data Feeder: changed from "ARERAS" to "UNIT1".

Data Feeder: changed from "ARERAS" to "UNIT1".

Data Feeder: changed from "ARERAS" to "UNIT1".

BV2 WS035SR BV2 WSSObSR BV2 WD150SR BV2 WDSOOSR BV2 TS150SR BV2 TSSOOSR BV2 XM006 BV2 XM026 BV2 XM051 BV2 XM061 BV2 XM083 BV2 XM087

/

Attachment L-19-053 Summary of Changes to Data Point Library Page 2 of 2 Create new point named WS035SR with same fields as XM006.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Create new point named WSSOOSR with same fields as XM026.

Date: changed to '"01/28/19", Data Feeder: changed to "MET" Create new point named WD150SR with same fields as XM051.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Create new point named WDSOOSR with same fields as XM061.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Create new point named TS150SR with same fields as XM083.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Create new point named TSSOOSR with same fields as XM087.

Date: changed to "01/28/19", Data Feeder: changed to "MET" Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear aH other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID..

Date: changed to "01/28/19" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19 Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "01/28/19" Unique System.Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Enclosure L-19-053 Beaver Valley Power Station EROS Data Point Library, Updated Pages (29 pages follow)

UNIT POINTID DESCRIPTION PARAMETER PAGE BV2 R0098A 2MSS-RQl101B EXTRA10 2-87 BV2 R0099A 2MSS*RQl101C EXTRA11 2-88 BV1 WS035SR WIND SPEED 35' ELEVATION WIND-SPEED1 3-01 BV1 WS500SR WIND SPEED 500' ELEVATION WIND-SPEED2 3-02 BV1 WD150SR WIND DIRECTION 150' ELEVATION WIND-DIR1 3-03 BV1 WD500SR WIND DIRECTION 500' ELEVATION WIND-DIR2 3-04 BV1 TS150SR STABILITY-GROUND LEVEL STAB-CLASS1 3-05 BV1 TS500SR STABILITY-ELEVATED STAB-CLASS2 3-06 BV2 WS035SR WIND SPEED 35' ELEVATION WIND-SPEED1 3-07 BV2 WS500SR WIND SPEED 500' ELEVATION WIND-SPEED2 3-08 BV2 WD150SR WIND DIRECTION 150' ELEVATION WIND-D1R1 3-09 BV2 WDSOOSR WIND DIRECTION 500' ELEVATION WIND-DIR2 3-10 BV2 TS150SR STABILITY-GROUND LEVEL STAB-CLASS1 3-11 BV2 TS500SR STABILITY-ELEVATED STAB-CLASS2 3-12 J

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

11/3/2011 Reactor Unit:

BV1 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID: XM006 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zeto Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/T'rip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 1-68

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

11/3/2011 Reactor Unit:

BV1 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XM026 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarmfrrlp Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Tum-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464

.59

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

11/14/1992 Reactor Unit:

BV1 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XM051 Plant Spec Point Deso.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 1-70

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

11/14/1992 Reactor Unit:

BV1 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XM061 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference -Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarmfrrip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Tum-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 1-71

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

11/14/1992 Reactor Unit:

BV1 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID: XM083 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Tum-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 1-72

(

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

11/14/1992 Reactor Unit:

BV1 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XM087 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarmrrrip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Tum-ON Power Level:

1.nstrument Failure Mode:

.Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 1-73

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

11/3/2011 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XMOD6 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Eilgr Units/Dig Stales:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point Referen.ce:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Fallure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 2-66

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

11/3/2011 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC ERDS Parameter:

Point ID:

XM026 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarmfrrip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Tum-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 2-67

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

  • 11/14/1992 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XM051 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 2-68

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

11/14/1992 Reactor Untt:

BV2 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XM061 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Tum-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 2-69

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

11/14/1992 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XM083 Plant Spec Point Desc.:

Generic/Cond Dase.:

Analog/Digital:

Engr Units/Dig Slates:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarmfrrip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Tum-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 2-70

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

11/14/1992 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC EROS Parameter:

Point ID:

XM087 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

point deleted per ECP 14-0464 2-71

  • )

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

MET NRC ERDS Parameter:

WIND-SPEED1 Point ID:

WS035SR Plant Spec Point Desc.:

WIND SPEED 35' ELEVATION Generic/Cond Desc.:

WIND SPE!:D AT THE REACTOR SITE Analog/Digital:

A Engr Units/Dig States:

MPH

  • Engr Units Conversion:

NIA Minimum Instr Range:

O Maximum Instr Range:

100 Zero Point

Reference:

NIA Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

N/A NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Turn-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used In dose assessments, as ground level speed.

Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-01

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

MET NRC EROS Parameter:

WIND-SPEED2 Point ID:

WS500SR Plant Spec Point Desc.:

WIND SPEED 500' ELEVATION Generic/Cond Desc.:

WIND SPEED AT THE REACTOR SITE Analog/Digital:

A Engr Units/Dig States:

MPH Engr Units Conversion:

NIA Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

NIA Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Tum-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

Point Is the 15 r:nlnute average value for primary sensor. Redundant sensor substituted If primaiy bad or missing. Sensors are same quality/calibration.

Value is dose assessments as elevated wind speed. Ref: Calculatlon Package ERS-SFL-92-024; CR 04-05484 3-02

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

MET NRC EROS Parameter:

WIND*D1R1 Point ID:

WD150SR Plant Spec Point Desc.:

WIND DIRECTION 150' ELEVATION Generic/Cond Desc.:

WIND DIRECTION AT REACTOR SITE Analog/Digital:

A Engr Units/Dig States:

DEGFR Engr Units Conversion:

N/A Minimum Instr Range:

O Maximum Instr Range:

360 Zero Point

Reference:

N/A Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Tum-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

N/A Unique System Desc.:

Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments as ground level direction. Wind direction O Is North. Wind direction Is direction from which wind Is coming. Ref: Calculation Package ERS-SFL-92-024: CR 04-05484 3-03

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

MET NRC ERDS Parameter:

WIND-DIR2 Point ID:

WD500SR Plant Spec Point Desc.:

WIND DIRECTION 500' ELEVATION Generic/Cond Desc.:

WIND DIRECTION AT REACTOR SITE Analog/Digital:

A Engr Units/Dlg States:

DEGFR Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

360 Zero Point

Reference:

NTA Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

N/A NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Turn-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Dase.:

Point is the 15 minute average value for primary sensor. Redundant sensor value substituted If primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments as ground level direction. Wind direction O Is North. Wind direction is direction from which wind Is coming. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-04

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

MET NRC EROS Parameter:

STAB-CLASS1 Point ID:

TS150SR Plant Spec Point Desc.:

STABILITY-GROUND LEVEL Generic/Cond Desc.:

AIR STABILITY AT REACTOR SITE Analog/Digital:

A Engr Units/Dig States:

STABI Engr Units Conversion:

NIA Minimum Instr Range:

1 Maximum Instr Range:

7 Zero Point

Reference:

N/A Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

N/A NI Detector Power Supply Turn-ON Power Level:

N/A Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

Point is based on 15 minute average Delta-T for 35' and 150' temperature sensors. Based on redundant sensor if primary bad or missing. Sensors are same quality/calibration. Stability classes 1 thru 7 correspond to stability classes A to G. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-05

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder.

MET NRC ERDS Parameter.

STAB-CLASS2 Point ID:

TS500SR Plant Spec Point Desc.:

STABILITY-ELEVATED Generic/Cond Desc.:

AIR STABILITY AT REACTOR SITE Analog/Digital:

A Engr UnitsfDig States:

STABI Engr Units Conversion:

N/A Minimum Instr Range:

1 Maximum Instr Range:

7 Zero Point

Reference:

N/A Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

N/A NI Detector Power Supply Turn-ON Power Level:

N/A Instrument Failure Mode:

OEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

Point is based on 15 minute average Delta-T for 35' and 500' temperature sensors. Based on redundant sensor if primary bad or missing. Sensors are same quality/calibration. Stability classes 1 thru 7 correspond to stability classes A thru G. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-06

  • ~

BEAVER VALLEY POWER STATION ERDS DAl'A POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV2 Data Feeder:

MET NRC EROS Parameter:

WIND-SPEED1 Point ID:

WS035SR Plant Spec Point Desc.:

WIND SPEED 35' ELEVATION Generic/Cond Desc.:

WIND SPEED AT THE REACTOR SITE Analog/Digital:

A Engr Units/Dig States:

MPH Engr Units Conversion:

NIA Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

NIA Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alann/Trip Set Points:

N/A NI Detector Power Supply Cut-Off Power Level:

N/A NI Detector Power Supply Turn-ON Power Level:

N/A Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

N/A Unique System Desc.:

Point is the 15 minute average value for primary sensor. Redundant sensor value substituted If primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments, as ground level speed.

Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-07

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/2812019 Reactor Unit:

BV2 Data Feeder:

MET NRC ERDS Parameter:

WIND-SPEED2 Point ID: WS500SR Plant Spec Point Desc.:

WIND SPEED 500' ELEVATION Generic/Cond Desc.:

WIND SPEED AT THE REACTOR SITE Analog/DigHal:

A Engr Units/Dig States:

MPH Engr Units Conversion:

NIA Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

NIA Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Tum-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

Point is the 15 minute average value for primary sensor. Redundant sensor substituted If primary bad or missing. Sensors are same quality/calibration.

Value Is dose assessments as elevated wind speed. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-08

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit BV2 Data Feeder:

MET NRC EROS Parameter; WIND-DIR1 Point ID:

WD150SR Plant Spec Point Desc.:

WIND DIRECTION 150' ELEVATION Generic/Cond Desc.:

WIND DIRECTION AT REACTOR SITE Analog/Digital:

A Engr Units/Dig States:

DEGFR Engr Units Conversion:

N/A

'Minimum Instr Range:

0 Maximum Instr Range:

360 Zero Point

Reference:

NIA Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Turn-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments as ground level direction. Wind direction O is North. Wind direction is direction from which wind is coming. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-09

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV2 Data Feeder:

MET NRC ERDS Parameter:

WIND-D1R2 Point ID:

WD500SR Plant Spec Point Desc.:

WIND DIRECTION 500' ELEVATION Generic/Cond Desc.:

WIND DIRECTION AT REACTOR SITE Analog/Digital:

A Engr Units/Dig States:

DEGFR Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range: 360 Zero Point Referymce:

NIA Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

N/A NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Turn-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

Point is the 15 minute average value for primary sensor. Redundant sensor value substituted ifprlmary bad or missing. Sensors are same quality/calibration. Value used in dose assessments as ground level direction. Wind direction o is North. Wind direction is direction from which wind is coming. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-10

[)

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV2 Data Feeder:

MET NRC ERDS Parameter:

STA8-CLASS1 Point ID:

TS150SR Plant Spec Point Desc.:

STABILITY-GROUND LEVEL Generic/Cond Desc.:

AIR STABILITY AT REACTOR SITE Analog/Digital:

A Engr Units/Dig States:

STABI Engr Units Conversion:

NIA Minimum Instr Range:

1 Maximum Instr Range:

7 Zero Point

Reference:

NIA Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

FAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Turn-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

N/A Unique System Desc.:

Point is based on 15 minute average Delta-T for 35' and 150' temperature sensors. Based on redundant sensor If primary bad or missing. Sensors are same quality/calibration. Stablllty classes 1 thru 7 correspond to stability classes A to G. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 3-11

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV2 Data Feeder:

MET.

NRC EROS Parameter:

STAB-CLASS2 Point ID: TS500SR Plant Spec Point Desc.:

STABILITY-ELEVATED Generic/Cond Desc.:

AIR STABILITY AT REACTOR SITE Analog/Digital: A Engr Units/Dig States:

STAB!

Engr Units Conversion:

NIA Minimum Instr Range:

1 Maximum Instr Range:

7 Zero Point

Reference:

NIA Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

leAILOVER SUBSTITUTION Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Turn-ON Power Level:

N/A Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

Point is based on 15 minute average Delta-T for 35' and 500' tempe'rature sensors. Based on redundant sensor if primary bad or missing. Sensors are same quality/calibration. Stability classes 1 thru 7 correspond to stability classes A thru G. Ref: Calculation Package ERS-SFL-92,024; CR 04-05484 3-12

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

UNIT1 NRC EROS Parameter:

EXTRA11 Point ID:

XR001 Plant Spec Point Desc.:

1RM-MS-101 Generic/Cond Desc.:

RADIOACTIVITY OF RELEASED GASSES Analog/Digital:

A Engr Units/Dig States:

uCi/cc Engr Units Conversion:

NIA Mlnim~m Instr Range:

0.01 Maximum Instr Range:

4E4 Zero Point

Reference:

N/A Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

CALCULATED Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Turn-ON Power Level:

N/A Instrument Failure Mode:

DEPENDS ON FAILUR!:: MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

N/A Unique System Desc.:

RM-1 MS-101 monitors the activity in one of the two exhaust lines of the turbine driven auxiliary feed pump. High activity alarms alert the operator to abnormal conditions. Monitor is a gamma scintillation detector. Ref: Op Manual Chapter 43; RM-421-1; Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-74

rt' BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

UNIT1 NRC ERDS Parameter:

EXTRA12 Point ID:

XR002 Plant Spec Point Desc.:

1RM-MS-100A Generic/Cond Desc.:

RADIOACTIVITY OF RELEASED GASSES Analog/Digital:

A Engr Units/Dig States:

uCi/cc Engr Units Conversion:

NIA Minimum Instr Range:

0.01 Maximum Instr Range:

4E4 Zero Point

Reference:

N/A Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

CALCULATED Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Tum-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

RM-1 MS-1 OOA monitors the activity in the discharge path of Main Steam Relief Loop A when the Atmospheric Dump Valve or Main Steam Safety Valves discharge to the environment. Detector located ln discharge piping downstream of the lowest lift setpoint Main Steam Safety Valve and the Atmospheric Dump Valve on Main Stearn Relief Loop A. Ref: Op Manual Chapter43; RM-421-1; Calculation Package ERS-SFL-92-024; CR Q4-05484 1-75

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

UNIT1 NRC EROS Parameter:

EXTRA13 Point ID:

XR003 Plant Spec Point Desc.:

1RM-MS-10~8 Generic/Cond Desc.:

RADIOACTIVITY OF RELEASED GASSES Analog/Digital:

A Engr Units/Dig States:

uCi/cc Engr Units Conversion:

NIA Minimum Instr Range:

0.01 Maximum Instr Range:

4E4 Zero Point

Reference:

NIA Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

CALCULATED Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Tum-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

N/A Unique System Desc.:

RM-1MS-1008 monitors the activity in the discharge path of Main Steam Relief Loop B when the Atmospheric Dump Valve or Main Steam Safety Valves discharge to the environment. Detector located in discharge piping downstream of the lowest lift setpoint Main Steam.Safety Valve and the Atmospheric Dump Valve on Main Steam Relief Loop B. Ref: Op Manual Chapter 43; RM-421-1; Calculation Package ERS-SFL-92-024; CR. 04-05484 1-76

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

1/28/2019 Reactor Unit:

BV1 Data Feeder:

UNIT1 NRC ERDS Parameter:

EXTRA14 Point ID:

XR004 Plant Spec Point Desc.:

1RM-MS-100C Generic/Cond Deso.:

RADIOACTIVITY OF RELEASED GASSES Analog/Digital: A Engr Units/Dig States:

uCVcc Engr Units Conversion:

NIA Minimum Instr Range:

0.01 Maximum. Instr Range:

4E4 Zero Point

Reference:

NIA Reference Point Notes:

NIA PROC or SENS:

P Number of Sensors:

2 How Processed:

CALCULATED Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NIA NI Detector Power Supply Cut-Off Power Level:

NIA NI Detector Power Supply Tum-ON Power Level:

NIA Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

NIA Unique System Desc.:

RM-1 MS-100C monitors the activity in the discharge path of Main Steam Relief Loop C when the Atmospheric Dump Valve or Main Steam Safety Valves discharge to the environment. Detector located in discharge piping downstream of the lowest lift setpolnt Main Steam Safety Valve and the Atmospheric-Dump Valve on Main Steam Relief Loop C. Ref: Op Manual Chapter 43; RM-421-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-77