Revision as of 21:28, 10 February 2019

Fort Calhoun 1, Relief E-2, 4-th 10-year Pump and Valve Inservice Testing Program
ML060970124
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 04/06/2006
From: Terao D
Plant Licensing Branch III-2
To: Ridenoure R T
Omaha Public Power District
Wang A B
References
TAC MD0227
Download: ML060970124 (6)


Text

April 6, 2006Mr. R. T. RidenoureVice President - Chief Nuclear Officer Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.

Post Office Box 550 Fort Calhoun, NE 68023-0550

SUBJECT:

FORT CALHOUN STATION, UNIT NO. 1 - PUMP RELIEF REQUEST E-2 FORTHE FOURTH 10-YEAR PUMP AND VALVE INSERVICE TESTING PROGRAM (TAC NO. MD0227)

Dear Mr. Ridenoure:

By letter dated February 27, 2006, Omaha Public Power District (the licensee) submitted PumpRelief Request E-2 for its Fourth 10-year inservice testing program interval at the Fort Calhoun Station, Unit 1.The Nuclear Regulatory Commission (NRC) staff has completed its review of the subject reliefrequest. Pump Relief Request E-2 is authorized pursuant to Paragraph 50.55a(a)(3)(i) of Title 10 of the Code of Federal Regulations on the basis that the proposed alternative providesan acceptable level of quality and safety. The NRC staff's safety evaluation is enclosed. If you have any questions regarding the safety evaluation, please contact Alan B. Wang at(301) 415-1445.Sincerely,/RA/David Terao, ChiefPlant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-285

Enclosure:

Safety Evaluation cc w/encl: See next page April 6,2006Mr. R. T. Ridenoure Vice President - Chief Nuclear Officer Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.

Post Office Box 550 Fort Calhoun, NE 68023-0550

SUBJECT:

FORT CALHOUN STATION, UNIT NO. 1 - PUMP RELIEF REQUEST E-2 FORTHE FOURTH 10-YEAR PUMP AND VALVE INSERVICE TESTING PROGRAM (TAC NO. MD0227)

Dear Mr. Ridenoure:

By letter dated February 27, 2006, Omaha Public Power District (the licensee) submitted PumpRelief Request E-2 for its Fourth 10-year inservice testing program interval at the Fort Calhoun Station, Unit 1.The Nuclear Regulatory Commission (NRC) staff has completed its review of the subject reliefrequest. Pump Relief Request E-2 is authorized pursuant to Paragraph 50.55a(a)(3)(i) of Title 10 of the Code of Federal Regulations on the basis that the proposed alternative providesan acceptable level of quality and safety. The NRC staff's safety evaluation is enclosed. If you have any questions regarding the safety evaluation, please contact Alan B. Wang at(301) 415-1445.Sincerely,/RA/David Terao, Chief Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-285

Enclosure:

Safety Evaluation cc w/encl: See next pageDISTRIBUTION

PUBLIC LPLIV ReadingRidsNrrDorlLplg (DTerao)RidsNrrPMAWangRidsNrrLALFeizollahiTBloomer, RIV EDORidsAcrsAcnwMailCenter RidsNrrDorl (CHaney/CHolden)RidsRegion4MailCenter (DGraves)RidsOgcRpJMcHaleRidsNrrDeGSBediACCESSION NO.: NRR-028OFFICELPL4/PMLPL4/LACPTB-BCOGCLPL4/BCNAMEAWangLFeizollahiSLeeUwoods (NLO)DTeraoDATE3/31/063/30/063/22/064/5/064/6/06E:\Filenet\ML060970124.wpdOFFICIAL RECORD COPY SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATIONREQUEST FOR RELIEF FROM THE AMERICAN SOCIETY OF MECHANICAL ENGINEERSSECTION XI, INSERVICE TESTING PROGRAM OMAHA PUBLIC POWER DISTRICT FORT CALHOUN STATION, UNIT 1DOCKET NO. 50-28

51.0INTRODUCTION

By letter dated February 27, 2006, Omaha Public Power District (OPPD/the licensee),submitted a relief request for the fourth 10-year inservice testing (IST) program interval at Fort Calhoun Station (FCS), Unit 1. The licensee requested relief from a certain inservice test requirement of the 1998 Edition through 2000 Addenda of the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants (OM Code). The FCS fourth 10-year IST interval commenced in February 2004.

2.0REGULATORY EVALUATION

Section 50.55a of Title 10 of the Code of Federal Regulations (10 CFR) requires that IST ofcertain ASME Code Class 1, 2, and 3 pumps and valves be performed at 120-month (10-year)

IST program intervals in accordance with the specified ASME Code incorporated by reference in the regulations, except where alternatives have been authorized or relief has been requested by the licensee and granted by the Commission pursuant to paragraphs (a)(3)(i), (a)(3)(ii), or (f)(6)(i) of 10 CFR 50.55a. In accordance with 10 CFR 50.55a(f)(4)(ii), licensees are required to comply with the requirements of the latest edition and addenda of the ASME Code incorporated by reference in the regulations 12 months prior to the start of each 120-month IST program interval. In accordance with 50.55a(f)(4)(iv), IST of pumps and valves may meet the requirements set forth in subsequent editions and addenda that are incorporated by reference in 10 CFR 50.55a(b), subject to Nuclear Regulatory Commission (NRC) approval. Portions ofeditions or addenda may be used provided that all related requirements of the respective editions and addenda are met. In proposing alternatives or requesting relief, the licensee must demonstrate that: (1) the proposed alternatives provide an acceptable level of quality and safety; (2) compliance would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety; or (3) conformance is impractical for the facility. Section 50.55a authorizes the Commission to approve alternatives and to grant relief from ASME Code requirements upon making necessary findings. The NRC guidance contained inGeneric Letter (GL) 89-04, "Guidance on Developing Acceptable Inservice Testing Programs,"

provides alternatives to ASME Code requirements which are acceptable. Further guidance is given in GL 89-04, Supplement 1, and NUREG-1482, Revision 1, "Guidance for InserviceTesting at Nuclear Power Plants." The FCS, Unit 1, fourth 10-year IST interval commenced in February 2004. The program wasdeveloped in accordance with the 1998 Edition through 2000 Addenda of the ASME OM Code.

By letter dated November 5, 2002, OPPD requested relief from certain requirements of the ASME OM Code for its FCS, Unit 1, fourth 10-year IST interval. Revision 1 to the FCS IST Program Plan, modifying relief requests for certain ASME OM Code requirements, was submitted by letter dated December 5, 2003. By letter dated February 27, 2006, the licenseerequested relief for the pump flow test requirement of ISTB-5121(c).

3.0TECHNICAL EVALUATION

The Nuclear Regulatory Commission (NRC) staff's findings with respect to authorizingalternatives pursuant to 10 CFR 50.55a(a)(3)(i) are given below.3.1Pump Relief Request E-2 3.1.1Code RequirementsThe licensee requested relief from ISTB-5121(c), which requires that where system resistancecannot be varied, flow rate and pressure shall be determined and compared to their respective reference values. The relief requested applies to the following pumps:Low Pressure Safety Injection (LPSI) Pumps SI-1A, SI-1BHigh Pressure Safety Injection Pumps (HPSI) SI-2A, SI-2B Containment Spray (CS) Pumps SI-3A, SI-3B, SI-3C3.1.2Licensee's Basis for Requesting ReliefThe licensee states:The flow rate of the subject pumps cannot be measured when they are operating onminimum flow recirculation because flow instrumentation is not installed on the lines.

The minimum recirculation flow lines are used when testing the pumps quarterly during power operations. For the LPSI and HPSI pumps, the only other available flow path is to the Reactor Coolant System (RCS) where such flow is undesirable during power operation. The only other available flow path for the CS pumps is into the CS headers, which would result in water damage to equipment in containment.3.1.3Licensee's Proposed Alternative TestingThe licensee states:FCS proposes the following alternative to the ISTB-5121(c) requirement:

a.As a minimum, quarterly testing continues to measure pump differential pressureand vibration.b.During each refueling outage, a comprehensive test using Section ISTB-5123 ofthe ASME Code will be conducted under full or substantial flow rates. Pump differential pressure, flow rate, and bearing vibration measurements will betaken.c.Data from both quarterly and comprehensive tests will be monitored andanalyzed as required by Section ISTB-6000 of the ASME Code.This testing regimen provides an effective alternative to ISTB-5121(c).3.1.4 EvaluationThe licensee requests relief from the flow test requirement of ISTB-5121(c) where Group Apump tests are required for the subject pumps. ISTB-5121(c) requires that flow rate and pressure be determined and compared to their respective reference values. The licensee proposes testing the pumps quarterly without flow measurements and performing comprehensive tests using ISTB-5123 of the ASME Code with flow measurements at each refueling outage.The minimum flow recirculation line is the only path where flow can be established for thesubject pumps during quarterly testing with the plant at power. The HPSI and LPSI pumps do not generate sufficient head to overcome RCS pressure at normal operating conditions, and injection of borated water into the RCS at power is undesirable from a reactivity control standpoint. The CS header is undesirable as a flow path for the CS pumps during non-accident conditions due to the potential for water damage to equipment in the containment. T he syst emdesign is such that the recirculation flow path is the only path available for pump testing duringpower operations; however, flow rate cannot be measured due to lack of flow instrumentation in the recirculation line. The licensee has proposed performing quarterly tests via this non-instrumented flow path ensuring that, at a minimum, pump differential pressure and vibration measurements are continued. Additionally, comprehensive tests at full or substantialflow conditions will be performed during refueling outages or other cold shutdown conditionsthat meet IST frequency requirements. These tests will include flow measurements and shallmeet the requirements of ISTB-5123. The NRC staff has determined that this alternativetesting regimen is consistent with Position 9 of Attachment 1 to GL 89-04 and assures pump operability.

4.0CONCLUSION

The OPPD Relief Request E-2 has been reviewed by the NRC staff and based on the aboveevaluation, the NRC staff has concluded that the licensee's alternative is authorized pursuant to10 CFR 50.55a(a)(3)(i) on the basis that the proposed alternative provides an acceptable levelof quality and safety for quarterly Group A pump testing activities. This alternative is authorized for the remainder of the fourth 10-year IST interval.

All other ASME Code,Section XI, requirements for which relief was not specifically requested and approved in this relief request remain applicable, including third party review by the Authorized Nuclear Inservice Inspector.Principal Contributor: J. McHale Date: April 6, 2006 January 2006Ft. Calhoun Station, Unit 1 cc:

Winston & Strawn ATTN: James R. Curtiss, Esq.

1400 L Street, N.W.

Washington, DC 20005-3502ChairmanWashington County Board of Supervisors

P.O. Box 466 Blair, NE 68008Mr. John Hanna, Resident InspectorU.S. Nuclear Regulatory Commission

P.O. Box 310 Fort Calhoun, NE 68023Regional Administrator, Region IVU.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-4005Ms. Julia Schmitt, Manager Radiation Control Program Nebraska Health & Human Services R & L Public Health Assurance 301 Centennial Mall, South P.O. Box 95007 Lincoln, NE 68509-5007Mr. David J. Bannister, ManagerFort Calhoun Station Omaha Public Power District Fort Calhoun Station FC-1-1 Plant

P.O. Box 550 Fort Calhoun, NE 68023-0550Mr. Joe L. McManisManager - Nuclear Licensing Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.

P.O. Box 550 Fort Calhoun, NE 68023-0550Mr. Daniel K. McGheeBureau of Radiological HealthIowa Department of Public Health Lucas State Office Building, 5th Floor 321 East 12th Street Des Moines, IA 50319