Browns Ferry Unit 1 ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-10 Fuel Assemblies (105% OLTP) Page 3-4 on previous transitions involving GE14 fuel. Similar agreement occurs at lower power levels.As shown in Table 3.5, [] Table 3.6 shows that, [] Differences in assembly flow between the ATRIUM-10 and GE14 fuel designs as a function of assembly power level are shown in Figure 3.2 and Figure 3.3.Core pressure drop and core bypass flow fraction are also provided for the configurations evaluated.
Browns Ferry Unit 1 ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-10 Fuel Assemblies (105% OLTP) Page 3-4 on previous transitions involving GE14 fuel. Similar agreement occurs at lower power levels.As shown in Table 3.5, [] Table 3.6 shows that, [] Differences in assembly flow between the ATRIUM-10 and GE14 fuel designs as a function of assembly power level are shown in Figure 3.2 and Figure 3.3.Core pressure drop and core bypass flow fraction are also provided for the configurations evaluated.
Based on the reported changes in pressure drop and assembly flow caused by the transition from GE14 to ATRIUM-1 0, the ATRIUM-10 design is considered hydraulically compatible with the GE14 design since the thermal-hydraulic design criteria are satisfied.
Based on the reported changes in pressure drop and assembly flow caused by the transition from GE14 to ATRIUM-1 0, the ATRIUM-10 design is considered hydraulically compatible with the GE14 design since the thermal-hydraulic design criteria are satisfied.
3.3 Thermal Margin Performance Relative thermal margin analyses were performed in accordance with the thermal-hydraulic methodology for AREVA's XCOBRA code. The calculation of the fuel assembly critical power ratio (CPR) (thermal margin performance) is established by means of an empirical correlation based on results of boiling transition test programs.
 
===3.3 Thermal===
Margin Performance Relative thermal margin analyses were performed in accordance with the thermal-hydraulic methodology for AREVA's XCOBRA code. The calculation of the fuel assembly critical power ratio (CPR) (thermal margin performance) is established by means of an empirical correlation based on results of boiling transition test programs.
The CPR methodology is the approach used by AREVA to determine the margin to thermal limits for BWRs.CPR values for ATRIUM-10 and GE14 fuel are calculated with the SPCB critical power correlation (Reference 7). The NRC-approved methodology to demonstrate the acceptability of using the SPCB correlation for computing GE14 fuel CPR is presented in Reference 8.Assembly design features are incorporated in the CPR calculation through the F-eff term. The F-eff is based on the local power peaking for the nuclear design and on additive constants determined in accordance with approved procedures.
The CPR methodology is the approach used by AREVA to determine the margin to thermal limits for BWRs.CPR values for ATRIUM-10 and GE14 fuel are calculated with the SPCB critical power correlation (Reference 7). The NRC-approved methodology to demonstrate the acceptability of using the SPCB correlation for computing GE14 fuel CPR is presented in Reference 8.Assembly design features are incorporated in the CPR calculation through the F-eff term. The F-eff is based on the local power peaking for the nuclear design and on additive constants determined in accordance with approved procedures.
The local peaking factors are a function of assembly void fraction and exposure.For the compatibility evaluation, steady-state analyses evaluated ATRIUM-10 and GEI4 assemblies with radial peaking factors (RPFs) between [AREVA NP Inc.
The local peaking factors are a function of assembly void fraction and exposure.For the compatibility evaluation, steady-state analyses evaluated ATRIUM-10 and GEI4 assemblies with radial peaking factors (RPFs) between [AREVA NP Inc.
Line 111: Line 113:
Browns Ferry Unit 1 ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-10 Fuel Assemblies (105% OLTP) Page 3-6 shows that the ATRIUM-10 fuel design has decay ratios equivalent to or better than other approved AREVA fuel designs.As stated above, the stability performance of a core is strongly dependent on the core power, core flow, and power distribution in the core. Therefore, core stability is evaluated on a cycle-specific basis and addressed in the reload licensing report.AREVA NP Inc.
Browns Ferry Unit 1 ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-10 Fuel Assemblies (105% OLTP) Page 3-6 shows that the ATRIUM-10 fuel design has decay ratios equivalent to or better than other approved AREVA fuel designs.As stated above, the stability performance of a core is strongly dependent on the core power, core flow, and power distribution in the core. Therefore, core stability is evaluated on a cycle-specific basis and addressed in the reload licensing report.AREVA NP Inc.
Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 3-7 Table 3.1 Design Evaluation of Thermal and Hydraulic Criteria for the ATRIUM-10 Fuel Assembly Report Section Description Criteria Results or Disposition Thermal and Hydraulic Criteria 3.1 / 3.2 Hydraulic Hydraulic flow resistance Verified on a plant-specific basis.compatibility shall be sufficiently similar to existing fuel ATRIUM-10 demonstrated to be such that there is no compatible with GE14.significant impact on total core flow or flow [distribution among assemblies.
Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 3-7 Table 3.1 Design Evaluation of Thermal and Hydraulic Criteria for the ATRIUM-10 Fuel Assembly Report Section Description Criteria Results or Disposition Thermal and Hydraulic Criteria 3.1 / 3.2 Hydraulic Hydraulic flow resistance Verified on a plant-specific basis.compatibility shall be sufficiently similar to existing fuel ATRIUM-10 demonstrated to be such that there is no compatible with GE14.significant impact on total core flow or flow [distribution among assemblies.
3.3 Thermal margin Fuel design shall be SPCB is applied to both the performance within the limits of ATRIUM-10 and GE14 fuel.applicability of an approved CHF correlation.
 
===3.3 Thermal===
margin Fuel design shall be SPCB is applied to both the performance within the limits of ATRIUM-10 and GE14 fuel.applicability of an approved CHF correlation.
< 0.1% of rods in boiling Verified on cycle-specific basis for transition.
< 0.1% of rods in boiling Verified on cycle-specific basis for transition.
Chapter 14 analyses.Fuel centerline No centerline melting. Refer to the mechanical design temperature report.3.4 Rod bow 'Rod bow must be The lateral displacement of the fuel accounted for in rods due to fuel rod bowing is not of establishing thermal sufficient magnitude to impact margins, thermal margins.3.5 Bypass flow Bypass flow Verified on a plant-specific basis.characteristics shall be similar among Analysis results demonstrate that assemblies to provide adequate bypass flow is provided.adequate bypass flow.AREVA NP Inc.
Chapter 14 analyses.Fuel centerline No centerline melting. Refer to the mechanical design temperature report.3.4 Rod bow 'Rod bow must be The lateral displacement of the fuel accounted for in rods due to fuel rod bowing is not of establishing thermal sufficient magnitude to impact margins, thermal margins.3.5 Bypass flow Bypass flow Verified on a plant-specific basis.characteristics shall be similar among Analysis results demonstrate that assemblies to provide adequate bypass flow is provided.adequate bypass flow.AREVA NP Inc.
Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-1 0 Fuel Assemblies (105% OLTP)ANP-2821(NP)
Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-1 0 Fuel Assemblies (105% OLTP)ANP-2821(NP)
Revision 0 Page 3-8 Table 3.1 Design Evaluation of Thermal and Hydraulic Criteria for the ATRIUM-10 Fuel Assembly (Continued)
Revision 0 Page 3-8 Table 3.1 Design Evaluation of Thermal and Hydraulic Criteria for the ATRIUM-10 Fuel Assembly (Continued)
Report Section Description Criteria Results or Disposition Thermal and Hydraulic Criteria (Continued) 3.6 Stability New fuel designs are ATRIUM-10 channel and core stable in the approved decay ratios have been power and flow operating demonstrated to be equivalent to or region, and stability better than other approved AREVA performance will be fuel designs.equivalent to (or better than) existing (approved)
Report Section Description Criteria Results or Disposition Thermal and Hydraulic Criteria (Continued)
 
===3.6 Stability===
 
New fuel designs are ATRIUM-10 channel and core stable in the approved decay ratios have been power and flow operating demonstrated to be equivalent to or region, and stability better than other approved AREVA performance will be fuel designs.equivalent to (or better than) existing (approved)
Core stability behavior is evaluated AREVA fuel designs. on a cycle-specific basis.LOCA analysis LOCA analyzed in Approved Appendix K LOCA accordance with model.Appendix K modeling requirements.
Core stability behavior is evaluated AREVA fuel designs. on a cycle-specific basis.LOCA analysis LOCA analyzed in Approved Appendix K LOCA accordance with model.Appendix K modeling requirements.
Criteria Plant- and fuel-specific analysis defined in 10 CFR 50.46. with cycle-specific verifications.
Criteria Plant- and fuel-specific analysis defined in 10 CFR 50.46. with cycle-specific verifications.

Revision as of 05:27, 14 October 2018

ANP-2821(NP), Revision 0, Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM-10 Fuel Assemblies (105% Oltp).
ML101160154
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 06/30/2009
From:
AREVA, AREVA NP, Siemens
To:
Office of Nuclear Reactor Regulation
References
TAC ME0438, TAC ME2451 ANP-2821(NP), Rev 0
Download: ML101160154 (28)


Text

ATTACHMENT 9 Browns Ferry Nuclear Plant (BFN)Unit 1 Technical Specifications (TS) Change 473 AREVA Fuel Transition Thermal Hydraulic Design Report Attached is the non proprietary version of the thermal hydraulic design report.

AN P-2821 (N P)Revision 0 Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)June 2009 AREVA AREVA NP Inc.ANP-2821 (NP)Revision 0 Browns Ferry Unit I Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)

AREVA NP Inc.ANP-2821(NP)

Revision 0 Copyright

© 2009 AREVA NP Inc.All Rights Reserved paj Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821(NP)

Revision 0 Page i Nature of Changes Item Page Description and Justification

1. All This is the initial issue.AREVA NP Inc.

Browns Ferry Unit 1 ANP-2821(NP)

Thermal-Hydraulic Design Report Revision 0 for ATRIUMTm-1 0 Fuel Assemblies (105% OLTP) Page ii Contents 1 .0 In tro d u ctio n ....................................................................................................................

1-1 2.0 S um m ary and C onclusions

...........................................................................................

2-1 3.0 Thermal-Hydraulic Design Evaluation

............................................................................

3-1 3.1 Hydraulic C haracterization

.................................................................................

3-2 3.2 H ydraulic C om patibility

......................................................................................

3-3 3.3 Thermal Margin Performance

.............................................................................

3-4 3 .4 R o d B ow .............................................................................................................

3 -5 3 .5 B ypass F low .......................................................................................................

3-5 3 .6 S ta b ility ...............................................................................................................

3 -5 4 .0 R e fe re nce s .....................................................................................................................

4 -1 Tables 3.1 Design Evaluation of Thermal and Hydraulic Criteria for the ATRIUM-10 Fuel A sse m bly ........................................................................................................................

3 -7 3.2 Comparative Description of Browns Ferry Unit 1 ATRIUM-10 and GE14 Fuel ...... 3-9 3.3 Hydraulic Characterization Comparison Between Browns Ferry Unit 1 ATRIUM-10 and GE14 Fuel Assemblies

...............

.......................................................

3-10 3.4 Browns Ferry Unit 1 Thermal-Hydraulic Design Conditions

.........................................

3-11 3.5 Browns Ferry Unit 1 Transition Core Thermal-Hydraulic Results at Rated C onditions (100% P / 100% F) ......................................................................................

3-12 3.6 Browns Ferry Unit 1 Transition Core Thermal-Hydraulic Results at Off-Rated C onditions (62% P / 37.3% F) ........................................................................................

3-13 3.7 Browns Ferry Unit 1 Thermal-Hydraulic Results at Rated Conditions (100%P /100%F) for Transition to ATRIUM-10 Fuel ...................................................................

3-14 3.8 Browns Ferry Unit 1 Thermal-Hydraulic Results at Off-Rated Conditions (62%P / 37.3%F) for Transition to ATRIUM-10 Fuel ....................................................

3-15 Figures 3.1 A xial P ow er S hapes ..................................................................

..................................

3-16 3.2 Transition Core: Hydraulic Demand Curves 100%P/100%F

........................................

3-17 3.3 Transition Core: Hydraulic Demand Curves 62%P/37.3%F

..................

3-18 AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUMm-1 0 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page iii Nomenclature AOO ASME BWR CHF CPR CRDA LOCA LTP MAPLHGR MCPR NRC PLFR RPF UTP anticipated operational occurrence American Society of Mechanical Engineers boiling water reactor critical heat flux critical power ratio control rod drop accident loss-of-coolant accident lower tie plate maximum average planar linear heat generation rate minimum critical power ratio Nuclear Regulatory Commission, U.S.part-length fuel rod radial peaking factor upper tie plate AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRlUMTM-10 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 1-1 1.0 Introduction The results of Browns Ferry Unit 1 thermal-hydraulic analyses are presented to demonstrate that AREVA NP* ATRIUM T-10t fuel is hydraulically compatible with coresident GEI4 fuel. This report also provides the hydraulic characterization of the ATRIUM-10 and coresident GE14 fuel designs for Browns Ferry Unit 1.The generic thermal-hydraulic design criteria applicable to the design have been reviewed and approved by the U.S. Nuclear Regulatory Commission (NRC) in the topical report ANF-89-98(P)(A)

Revision 1 and Supplement I (Reference 1). In addition, thermal-hydraulic criteria applicable to the design have also been reviewed and approved by the NRC in the topical report XN-NF-80-19(P)(A)

Volume 4 Revision 1 (Reference 2).* AREVA NP Inc. is an AREVA and Siemens company.t ATRIUM is a trademark of AREVA NP.AREVA NP Inc.

Browns Ferry Unit 1 ANP-2821(NP)

Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-1 0 Fuel Assemblies (105% OLTP) Page 2-1 2.0 Summary and Conclusions ATRIUM-1 0 fuel assemblies have been determined to be hydraulically compatible with GE14 fuel coresident in the reactor for the entire range of the licensed power-to-flow operating map.Detailed calculation results supporting this conclusion are provided in Section 3.2 and Tables 3.4 to 3.8.The ATRIUM-10 fuel design is geometrically different from the coresident GE14 design, but hydraulically the two designs are compatible.

[Core bypass flow (defined as leakage flow through the lower tie plate (LTP) flow holes, channel seal, core support plate, and LTP-fuel support interface) is not adversely affected by the introduction of the ATRIUM-10 fuel design. Analyses at rated conditions show core bypass flow varying between [ ] of rated flow for transition core configurations ranging from a full GEI4 fuel core to a full ATRIUM-10 core, respectively.

Analyses demonstrate the thermal-hydraulic design and compatibility criteria discussed in Section 3.0 are satisfied for the Browns Ferry Unit 1 transition core consisting of ATRIUM-1 0 and GE14 fuel for the expected core power distributions and core power/flow conditions encountered during operation.

AREVA NP Inc.

Browns Ferry Unit I ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTm-10 Fuel Assemblies (105% OLTP) Page 3-1 3.0 Thermal-Hydraulic Design Evaluation Thermal-hydraulic analyses are performed to verify that design criteria are satisfied and to help establish thermal operating limits with acceptable margins of safety during normal reactor operation and anticipated operational occurrences (AOOs). The design criteria that are applicable to the ATRIUM-10 fuel design are described in Reference

1. To the extent possible, these analyses are performed on a generic fuel design basis. However, due to reactor and cycle operating differences, many of the analyses supporting these thermal-hydraulic operating limits are performed on a plant- and cycle-specific basis and are documented in plant- and cycle-specific reports.The thermal-hydraulic design criteria are summarized below: Hydraulic compatibility.

The hydraulic flow resistance of the reload fuel assemblies shall be sufficiently similar to the existing fuel in the reactor such that there is no significant impact on total core flow or the flow distribution among assemblies in the core. This criterion evaluation is addressed in Sections 3.1 and 3.2.Thermal margin performance.

Fuel assembly geometry, including spacer design and rod-to-rod local power peaking, should minimize the likelihood of boiling transition during normal reactor operation as well as during AQOs. The fuel design should fall within the bounds of the applicable empirically based boiling transition correlation approved for AREVA reload fuel. Within other applicable mechanical, nuclear, and fuel performance constraints, the fuel design should achieve good thermal margin performance.

The thermal-hydraulic design impact on steady-state thermal margin performance is addressed in Section 3.3. Additional thermal margin performance evaluations dependent on the cycle-specific design are addressed in the reload licensing report.Fuel centerline temperature.

Fuel design and operation shall be such that fuel centerline melting is not projected for normal operation and AQOs. This criterion evaluation is addressed in the mechanical design report.Rod bow. The anticipated magnitude of fuel rod bowing under irradiation shall be accounted for in establishing thermal margin requirements.

This criterion evaluation is addressed in Section 3.4.Bypass flow. The bypass flow characteristics of the reload fuel assemblies shall not differ significantly from the existing fuel in order to provide adequate flow in the bypass region. This criterion evaluation is addressed in Section 3.5.Stability.

Reactors fueled with new fuel designs must be stable in the approved power and flow operating region. The stability performance of new fuel designs will be equivalent to, or better than, existing (approved)

AREVA fuel designs. This criterion evaluation is addressed in Section 3.6. Additional core stability evaluations dependent on the cycle-specific design are addressed in the reload licensing report.AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design.Report for ATRIUMm-1 0 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 3-2 Loss-of-coolant accident (LOCA) analysis.

LOCAs are analyzed in accordance with Appendix K modeling requirements using NRC-approved models. The criteria are defined in 10 CFR 50.46. LOCA analysis results are presented in the break spectrum and MAPLHGR reports.Control rod drop accident (CRDA) analysis.

The deposited enthalpy must be less than 280 cal/gm for fuel coolability.

This criterion evaluation is addressed in the reload licensing report.ASME overpressurization analysis.

ASME pressure vessel code requirements must be satisfied.

This criterion evaluation is addressed in the reload licensing report.Seismic/LOCA liftoff. Under accident conditions, the assembly must remain engaged in the fuel support. This criterion evaluation is addressed in the mechanical design report.A summary of the thermal-hydraulic design evaluations is given in Table 3.1.3.1 Hydraulic Characterization Basic geometric parameters for ATRIUM-10 and GE14 fuel designs are summarized in Table 3.2. Component loss coefficients for the ATRIUM-10 are based on tests and are presented in Table 3.3. These loss coefficients include modifications to the test data reduction process [] The bare rod friction, ULTRAFLOW T M* spacer, and UTP losses for ATRIUM-10 are based on flow tests. The local losses for the Browns Ferry ATRIUM-10 FUELGUARDr*

LTP are based on pressure drop tests performed at AREVA's Portable Hydraulic Test Facility.

[] The local component (LTP, spacer, and UTP) loss coefficients for the GE14 fuel are based on flow test results.The primary resistance for the leakage flow through the LTP flow holes is [] The resistances for the leakage paths are shown in Table 3.3.* ULTRAFLOW and FUELGUARD are trademarks of AREVA NP.AREVA NP Inc.

Browns Ferry Unit 1 ANP-2821(NP)

Thermal-Hydraulic Design Report Revision 0 for ATRIUM TM-1 0 Fuel Assemblies (105% OLTP) Page 3-3 3.2 Hydraulic Compatibility The thermal-hydraulic analyses were performed in accordance with the AREVA thermal-hydraulic methodology for BWRs. The methodology and constitutive relationships used by AREVA for the calculation of pressure drop in BWR fuel assemblies are presented in Reference 3 and are implemented in the XCOBRA code. The XCOBRA code predicts steady-state thermal-hydraulic performance of the fuel assemblies of BWR cores at various operating conditions and power distributions.

XCOBRA received NRC approval in Reference 4.The NRC reviewed the information provided in Reference 5 regarding inclusion of water rod models in XCOBRA and accepted the inclusion in Reference 6.Hydraulic compatibility, as it relates to the relative performance of the ATRIUM-10 and GE14 fuel designs, has been evaluated.

Detailed analyses were performed for full core GE14 and full core ATRIUM-10 configurations.

Analyses for a mixed ATRIUM-10 and GE14 core were also performed to demonstrate that the thermal-hydraulic design criteria are satisfied for a transition core configuration.

The hydraulic compatibility analysis is based on [Table 3.4 summarizes the input conditions for the analyses.

These conditions reflect two of the state points considered in the analyses:

100% power/100%

flow and 62% power/37.3%

flow.Table 3.4 also defines the core loading for the transition core configuration.

Input for other core configurations is similar in that core operating conditions remain the same and the same axial power distribution is used. Evaluations were made with the bottom-, middle-, and top-peaked axial power distributions presented in Figure 3.1. Results presented in this report are for the bottom-peaked power distribution.

Results for middle- and top-peaked axial power distributions show similar trends.Table 3.5 and Table 3.6 provide a summary of calculated thermal-hydraulic results using the transition core configuration.

Table 3.7 and Table 3.8 provide a summary of results for all core configurations evaluated.

Core average results and the differences between ATRIUM-10 and GE14 fuel rated power results are within the range considered compatible, as expected based AREVA NP Inc.

Browns Ferry Unit 1 ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-10 Fuel Assemblies (105% OLTP) Page 3-4 on previous transitions involving GE14 fuel. Similar agreement occurs at lower power levels.As shown in Table 3.5, [] Table 3.6 shows that, [] Differences in assembly flow between the ATRIUM-10 and GE14 fuel designs as a function of assembly power level are shown in Figure 3.2 and Figure 3.3.Core pressure drop and core bypass flow fraction are also provided for the configurations evaluated.

Based on the reported changes in pressure drop and assembly flow caused by the transition from GE14 to ATRIUM-1 0, the ATRIUM-10 design is considered hydraulically compatible with the GE14 design since the thermal-hydraulic design criteria are satisfied.

3.3 Thermal

Margin Performance Relative thermal margin analyses were performed in accordance with the thermal-hydraulic methodology for AREVA's XCOBRA code. The calculation of the fuel assembly critical power ratio (CPR) (thermal margin performance) is established by means of an empirical correlation based on results of boiling transition test programs.

The CPR methodology is the approach used by AREVA to determine the margin to thermal limits for BWRs.CPR values for ATRIUM-10 and GE14 fuel are calculated with the SPCB critical power correlation (Reference 7). The NRC-approved methodology to demonstrate the acceptability of using the SPCB correlation for computing GE14 fuel CPR is presented in Reference 8.Assembly design features are incorporated in the CPR calculation through the F-eff term. The F-eff is based on the local power peaking for the nuclear design and on additive constants determined in accordance with approved procedures.

The local peaking factors are a function of assembly void fraction and exposure.For the compatibility evaluation, steady-state analyses evaluated ATRIUM-10 and GEI4 assemblies with radial peaking factors (RPFs) between [AREVA NP Inc.

Browns Ferry Unit I ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-1 0 Fuel Assemblies (105% OLTP) Page 3-5] Table 3.5 and Table 3.6 show CPR results of the ATRIUM-10 and GE14 fuels.Table 3.7 and Table 3.8 show similar comparisons of CPR and assembly flow for the various core configurations evaluated.

Analysis results indicate ATRIUM-10 fuel will not cause thermal margin problems for the coresident GE14 fuel.3.4 Rod Bow The bases for rod bow are discussed in the mechanical design report. Rod bow magnitude is determined during the fuel-specific mechanical design analyses.

Rod bow has been measured during post-irradiation examinations of BWR fuel fabricated by AREVA.]3.5 Bypass Flow Total core bypass flow is defined as leakage flow through the LTP flow holes, channel seal, core support plate, and LTP-fuel support interface.

Table 3.7 shows that total core bypass flow (excluding water rod flow) fraction at rated conditions changes from [ ] of rated core flow during the transition from a full GE14 core to a full ATRIUM-10 core (bottom-peaked power shape). [] In summary, adequate bypass flow will be available with the introduction of the ATRIUM-1 0 fuel design and applicable design criteria are met.3.6 Stability Each new fuel design is analyzed to demonstrate that the stability performance is equivalent to or better than an existing (NRC-approved)

AREVA fuel design. The stability performance is a function of the core power, core flow, core power distribution, and to a lesser extent, the fuel design. [] A comparative stability analysis was performed with the NRC-approved STAIF code (Reference 9). The study AREVA NP Inc.

Browns Ferry Unit 1 ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-10 Fuel Assemblies (105% OLTP) Page 3-6 shows that the ATRIUM-10 fuel design has decay ratios equivalent to or better than other approved AREVA fuel designs.As stated above, the stability performance of a core is strongly dependent on the core power, core flow, and power distribution in the core. Therefore, core stability is evaluated on a cycle-specific basis and addressed in the reload licensing report.AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 3-7 Table 3.1 Design Evaluation of Thermal and Hydraulic Criteria for the ATRIUM-10 Fuel Assembly Report Section Description Criteria Results or Disposition Thermal and Hydraulic Criteria 3.1 / 3.2 Hydraulic Hydraulic flow resistance Verified on a plant-specific basis.compatibility shall be sufficiently similar to existing fuel ATRIUM-10 demonstrated to be such that there is no compatible with GE14.significant impact on total core flow or flow [distribution among assemblies.

3.3 Thermal

margin Fuel design shall be SPCB is applied to both the performance within the limits of ATRIUM-10 and GE14 fuel.applicability of an approved CHF correlation.

< 0.1% of rods in boiling Verified on cycle-specific basis for transition.

Chapter 14 analyses.Fuel centerline No centerline melting. Refer to the mechanical design temperature report.3.4 Rod bow 'Rod bow must be The lateral displacement of the fuel accounted for in rods due to fuel rod bowing is not of establishing thermal sufficient magnitude to impact margins, thermal margins.3.5 Bypass flow Bypass flow Verified on a plant-specific basis.characteristics shall be similar among Analysis results demonstrate that assemblies to provide adequate bypass flow is provided.adequate bypass flow.AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-1 0 Fuel Assemblies (105% OLTP)ANP-2821(NP)

Revision 0 Page 3-8 Table 3.1 Design Evaluation of Thermal and Hydraulic Criteria for the ATRIUM-10 Fuel Assembly (Continued)

Report Section Description Criteria Results or Disposition Thermal and Hydraulic Criteria (Continued)

3.6 Stability

New fuel designs are ATRIUM-10 channel and core stable in the approved decay ratios have been power and flow operating demonstrated to be equivalent to or region, and stability better than other approved AREVA performance will be fuel designs.equivalent to (or better than) existing (approved)

Core stability behavior is evaluated AREVA fuel designs. on a cycle-specific basis.LOCA analysis LOCA analyzed in Approved Appendix K LOCA accordance with model.Appendix K modeling requirements.

Criteria Plant- and fuel-specific analysis defined in 10 CFR 50.46. with cycle-specific verifications.

CRDA analysis < 280 cal/gm for Cycle-specific analysis is coolability.

performed.

ASME over- ASME pressure vessel Cycle-specific analysis is pressurization core requirements shall performed.

analysis be satisfied.

Seismic/LOCA Assembly remains Refer to the mechanical design liftoff engaged in fuel support. report.AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUMTM-1 0 Fuel Assemblies (105% OLTP)ANP-2821(NP)

Revision 0 Page 3-9 Table 3.2 Comparative Description of Browns Ferry Unit I ATRIUM-10 and GE14 Fuel Fuel Parameter ATRIUM-10 GE14 Number of fuel rods Full-length fuel rods 83 78 PLFRs 8 14 Fuel clad OD, in 0.3957 0.404 Number of spacers 8 8 Active fuel length, ft Full-length fuel rods 12.454 12.500 PLFRs 7.5 7.0 Hydraulic resistance characteristics Table 3.3 Table 3.3 Number of water rods 1 2 Water rod OD, in 1.378* 0.980* Square water channel outer width.AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM TM-10 Fuel Assemblies (105% OLTP)ANP-2821(NP)

Revision 0 Page 3-10 Table 3.3 Hydraulic Characterization Comparison Between Browns Ferry Unit 1 ATRIUM-10 and GE14 Fuel Assemblies I I AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 3-11 Table 3.4 Browns Ferry Unit I Thermal-Hydraulic Design Conditions Reactor conditions 100%P / 100%F 62%P / 37.3%F Core power level, MWVt 3458 2146 Core exit pressure, psia 1060 987 Core inlet enthalpy, Btu/Ibm 524.7 492.2 Total core coolant flow, Mlbm/hr 102.5 38.2 Axial power shape Bottom-peaked Bottom-peaked (Figure 3.1) (Figure 3.1)Number of Assemblies Central , Peripheral Region Region Transition Core Loading[ ][AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821(NP)

Revision 0 Page 3-12 Table 3.5 Browns Ferry Unit 1 Transition Core Thermal-Hydraulic Results at Rated Conditions (100%P I 100%F)I[I AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUMTm-10 Fuel Assemblies (105% OLTP)ANP-2821(NP)

Revision 0 Page 3-13 Table 3.6 Browns Ferry Unit I Transition Core Thermal-Hydraulic Results at Off-Rated Conditions (62%P I 37.3%F)AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUMTM-1 0 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 3-14 Table 3.7 Browns Ferry Unit I Thermal-Hydraulic Results at Rated Conditions (100%P I 100%F) for Transition to ATRIUM-10 Fuel AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821(NP)

Revision 0 Page 3-15 Table 3.8 Browns Ferry Unit I Thermal-Hydraulic Results at Off-Rated Conditions (62%P / 37.3%F) for Transition to ATRIUM-10 Fuel I I AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 3-16 Figure 3.1 Axial Power Shapes AREVA NP Inc.

Browns Ferry Unit 1 Thermal-Hydraulic Design Report for ATRIUM T M-10 Fuel Assemblies (105% OLTP)ANP-2821 (NP)Revision 0 Page 3-17 I Figure 3.2 Transition Core: Hydraulic Demand Curves 100%PiIOO%F AREVA NP Inc.

Browns Ferry Unit I Thermal-Hydraulic Design Report for ATRIUMTm-10 Fuel Assemblies (105% OLTP)ANP-2821(NP)

Revision 0 Page 3-18 I Figure 3.3 Transition Core: Hydraulic Demand Curves 62%PI37.3%F AREVA NP Inc.

Browns Ferry Unit 1 ANP-2821 (NP)Thermal-Hydraulic Design Report Revision 0 for ATRIUMTM-10 Fuel Assemblies (105% OLTP) Page 4-1 4.0 References

1. ANF-89-98(P)(A)

Revision 1 and Supplement 1, Generic Mechanical Design Criteria for BWR Fuel Designs, Advanced Nuclear Fuels Corporation, May 1995.2. XN-NF-80-19(P)(A)

Volume 4 Revision 1, Exxon NuclearMethodology for Boiling Water Reactors:

Application of the ENC Methodology to BWR Reloads, Exxon Nuclear Company, June 1986.3. XN-NF-79-59(P)(A), Methodology for Calculation of Pressure Drop in BWR Fuel Assemblies, Exxon Nuclear Company, November 1983.4. XN-NF-80-19(P)(A)

Volume 3 Revision 2, Exxon Nuclear Methodology for Boiling Water Reactors, THERMEX: Thermal Limits Methodology Summary Description, Exxon Nuclear Company, January 1987.5. Letter, R.A. Copeland (AREVA) to R.C. Jones (USNRC), "Explicit Modeling of BWR Water Rod in XCOBRA," RAC:002:90, January 9,1990.6. Letter, R.C. Jones (USNRC) to R.A. Copeland (AREVA), no subject (regarding XCOBRA water rod model), February 1, 1990.7. EMF-2209(P)(A)

Revision 2, SPCB Critical Power Correlation, Framatome ANP, September 2003.8. EMF-2245(P)(A)

Revision 0, Application of Siemens Power Corporation's Critical Power Correlations to Co-Resident Fuel, Siemens Power Corporation, August 2000.9. EMF-CC-074(P)(A)

Volume 1, STAIF -A Computer Program for BWR Stability Analysis in the Frequency Domain; and Volume 2, STAIF -A Computer Program for BWR Stability Analysis in the Frequency Domain -Code Qualification Report, Siemens Power Corporation, July 1994.AREVA NP Inc.