- Information Notice 1991-70, Improper Installation of Instrumentation Modules +
- ML17329A234 +
- ML17329A233 +
- ML17306A257 +
- ML18057B362 +
- ML20086E167 +
- ML20085N420 +
- ML20085N382 +
- ML20085N375 +
- ML20085N071 +
- ML20079P996 +
- ML20079P985 +
- ML20079P211 +
- ML20079P166 +
- ML20079P026 +
- ML20079M462 +
- ML20079M374 +
- ML20079M239 +
- ML20079L514 +
- ML20079L319 +
- ML20091F043 +
- ML20129F581 +
- ML20261J655 +
- ML20217Q836 +
- NLS9100717, Suppls Proposed Change 88 to License DPR-46,revising Spec 5.2.B Re Control Rod Absorber Matl,Dtd 910423,per NRC Request +
- ST-HL-AE-3903, Suppl to Special Rept:On 901126,fuel Oil Leak Noted at Injection Pump 1L of Standby Diesel 23.Caused by Crack on Threaded Portion of Delivery Valve Holder.Injection Pump Delivery Valve & Valve Holder Replaced on 901127 +
- ST-HL-AE-3921, Submits Special Rept Re Tube Plugged in SG 2D.Tube Experienced anti-vibration Bar Wear of 38% Through Wall Over Two Fuel Cycles of Operation.Tube Wear Did Not Exceed TS Limit of 40% +
- B13956, Requests Relief from ASME Code Section XI Requirements Per 10CFR50.55(g)(6)(i),in Response to Generic Ltr 90-05 +
- ML20086G794 +
- ML20125D616 +
- 05000325/LER-1991-025, :on 911003,HPCI Diaphragm Control Valve for Low Oil Pressure Trip Inoperable.Caused by Oil Leak During Valve Stroking Due to end-of-life Failure of Diaphragm.Diaphragm Replaced & Work Request Initiated +
- 05000285/LER-1991-021, :on 911004,inadvertent Partial Actuation of Containment Isolation Actuation Sys Occurred.Caused by Improper Switch Contact Stackup.Caution Tag Placed on Switch Until Corrective Actions Completed +
- 05000324/LER-1991-016-02, :on 911005,severe Weather Induced Voltage Drop on off-site Distrubution Line,Resulting in Primary Containment Isolations.Caused by Electrical Storm.No Corrective Actions Required +
- 05000354/LER-1990-022, :on 901022,inadvertent auto-start of Core Spray Pump a Occurred,Causing ESF Actuation.Caused by Technician Connecting Test Switch Lead to Wrong Terminal. Technician Counseled & Design Change Initiated +
- 05000352/LER-1991-023-01, :on 911007,reactor Protection Sys Inverter Output Circuit Breaker Tripped,Causing Loss of Power to Power Distribution Panel.Caused by Actuation of Relay. Alternate Test Method Under Development +
- 05000353/LER-1991-016-03, :on 911007,selector Switch Inadvertently Placed Next to Numbered Trip Unit,Resulting in Primary Containment & Reactor Vessel Isolation Control Sys Actuation.Technician Admonished +
- 05000370/LER-1991-011-05, :on 911004,CR Personnel Manually Started Motor Driven Auxiliary Feedwater Pumps.Caused by Defective Procedure.Mgt Will Mod Unit Shutdown Procedures OP/1,2/A/6100/02 +
- 05000416/LER-1991-011-02, :on 911003,discovered That Improper Group of Components Surveilled in 1987 for end-of-cycle Recirculation Pump Trip Sys.Caused by Inadequate Guidance in Procedures.Surveillance Performed +
- 05000445/LER-1991-024, :on 911004,main Steam Safety Valves Had Lift Setpoints Less than Setpoint Tolerance Allowed by Ts.Caused by Inadequate Procedure.Setpoint Verification Procedure Revised +
- 05000445/LER-1991-023, :on 911003,reactor Tripped Due to Erratic Operation of Main Turbine Electrohydraulic Controller.On 910713,reactor Tripped Due to Seal Problem on Hydraulic Fluid Pumps.Design Mod Initiated +
- ML20086B855 +
- ML20086C621 +
- ML20086B850 +
- ML20044B479 +
- ML20086A412 +
- ML20086A008 +
- IR 05000255/1991021 +
- ML18036A419 +
- IR 05000315/1991022 +
- PLA-3657, Forwards Response to NRC 910725 Request for Addl Info Re Proposed Amends 145 & 99 to Licenses NPF-14 & NPF-22, Respectively on Turbine Bldg Steam Tunnel Temp Isolation Setpoints +