ML17329A233

From kanterella
Jump to navigation Jump to search
Requests Withdrawal of Proposed Changes to Tech Spec 4.8.1.1.2.e.2 Re Diesel Generator Operability
ML17329A233
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 11/04/1991
From: Fitzpatrick E
AMERICAN ELECTRIC POWER CO., INC.
To: Murley T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
AEP:NRC:1142B, NUDOCS 9111120196
Download: ML17329A233 (4)


Text

ACCELERATED DJ UTION DEMONSTPATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RXDS)

ACCESSION NBR:9111120196 DOC.DATE: 91/11/04 NOTARIZED:

NO FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana M

50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana M

AUTH.NAME AUTHOR AFFILIATION FXTZPATRICK,E.

American Electric Power Co., Inc.

RECIP.NAME RECIPIENT AFFILIATION MURLEY,T.E.

Document Control Branch (Document Control Desk)

SUBJECT:

Requests withdrawal of proposed changes to Tech Spec 4.8.1.1.2.e.2 re diesel generator operability.

DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR I

ENCL

'0 SIZE:

c2 TITLE: OR Submittal:

General Distribution NOTES DOCKET 05000315 05000316 D

RECIPIENT ID CODE/NAME PD3-1 LA COLBURN,T.

INTERNAL: NRR/DET/ECMB 7D NRR/DOEA/OTS B11 NRR/DST/SELB 7E NRR/DST/SRXB 8E O~C~B

't 01 EXTERNAL: NRC PDR COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD3-1 PD NRR/DET/ESGB NRR/DST 8E2 NRR/DST/SICB8H7 NUDOCS-ABSTRACT OGC/HDS2

~

RES/DSIR/EXB NSIC COPIES LTTR ENCL D

D D

S NOTE TO ALL"RIDS" RECIPIENTS:

D D

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 18 ENCL

American Electric Power Service Corpore 1 Riverside Plaza Columbus, OH 43215 614 2231000 AEP:NRC:1142B Donald C.

Cook Nuclear Plant Units 1 and 2

Docket Nos.

50-315 and 50-316 License Nos.

DPR-58 and DPR-74 WITHDRAWAL OF PROPOSED CHANGES TO TECHNICAL SPECIFICATION 4.8

~ 1.1.2.e.2 U.

S. Nuclear Regulatory Commission Document Control Desk Washington, D.

C.

20555 Attn:

T.

E. Murley November 4, l99l

Dear Dr. Murley:

In our January 15, 1991 letter, among other changes, we requested to revise T/S 4.8.1.1.2.e

~ 2, which concerns diesel generator operability, to insert the term "steady state" as follows:

Verifying the generator capability to reject a load greater than or equal to 600 kw while maintaining steady state voltage at 4160 + 420 volts and frequency at 60 + 1.2 Hz."

We inserted these words to clarify the T/S so that, when the 600 kw load is dropped, the operator ignores the initial oscillation of the needle on the control room panel instruments that read voltage and frequency.

Using that initial oscillation of the instrument could cause the diesel generator to fail the surveillance when it is in fact operable.

This could occur even though the implementing procedure specifies the use of a pin recorder or visual recorder, which more accurately measure voltage and frequency, when performing the surveillance.

The purpose of this letter is to withdraw our request to revise T/S 4.8.1.1.2.e.2, as submitted in our letter AEP:NRC:1142 dated January 5,

1991.

This request is made based upon discussions with the NRC Project Manager.

It is noted that the other changes requested in this letter were issued as Amendments 155 (Unit 1) and 139 (Unit 2).

91 1 11 0

05OO0315 PDR ADOCK PDF; P

Dr. T.

E. Murley AEP:NRC:1142B This document has been prepared following Corporate procedures that incorporate a reasonable set of controls to ensure its accuracy and completeness prior to signature by the undersigned.

Sincerely, Vice President eh cc:

D. H. Williams, Jr.

A. A. Blind - Bridgman J.

R. Padgett G. Charnoff NFEM Section Chief A. B. Davis

- Region III NRC Resident Inspector

- Bridgman

fs