- 05000397/LER-1987-013, :on 870831,RHR Sys Min Flow Valve RHR-FCV-64B Discovered Operating Improperly.Caused by Mislocated Wire on Relay in Min Flow Valve Control Logic Due to Personnel Error & Inadequate Procedure.Wire Relocated + (11:30:50, 8 January 2025)
- GO2-87-238, Submits Supplemental Response to Insp Rept 50-397/87-09 Re Plans to Make post-trip Review Committees More Effective in Determining Causative Factors of Events.Implementation of Planned Changes Does Not Supplant Existing Procedure + (11:31:14, 8 January 2025)
- GO2-87-239, Requests Temporary Relief from Tech Spec Table 3.3.2-2,Item 1, Main Steam Line Tunnel Temp - High Re Increase in Trip Setpoint Value from 150 F to 156 F.Tech Spec Change to Address Inviolate Definition Concern Will Be Submitted + (11:31:49, 8 January 2025)
- ML17279A550 + (11:32:21, 8 January 2025)
- GO2-87-240, Application for Amend to License NPF-21,revising Tech Specs for Trip Setpoint for Item 1.d, Main Steam Line Tunnel Temp-High of Table 3.3.2-2,Isolation Actuation Instrumentation to Indicate Max Setpoint Value.Fee Paid + (11:32:22, 8 January 2025)
- ML17279A547 + (11:32:57, 8 January 2025)
- ML17279A546 + (11:32:58, 8 January 2025)
- ML17279A544 + (11:33:01, 8 January 2025)
- IR 05000397/1987022 + (11:33:04, 8 January 2025)
- ML17279A541 + (11:33:07, 8 January 2025)
- IR 05000397/1987018 + (11:33:10, 8 January 2025)
- ML17279A518 + (11:33:12, 8 January 2025)
- GO2-87-232, Responds to Generic Ltr 86-10.Util Determined That Providing Transfer Switch on Remote Shutdown Panel for RHR-V-8 Valve Preferred Method for Ensuring Isolation of Either RHR-V-8 or V-9 in Event of Control Room Fire + (11:33:13, 8 January 2025)
- 05000397/LER-1987-024, :on 870722,limitorque motor-operated open- Direction Torque Switch Bypass Jumper Discovered Missing. Caused by Personnel Error.All Missing Jumpers Installed & Memo Re Top Tier Drawings Issued to Personnel + (11:33:21, 8 January 2025)
- GO2-87-229, WNP-2 Semiannual Effluent Rept,Jan Through June 1987 + (11:33:23, 8 January 2025)
- ML17279A492 + (11:33:29, 8 January 2025)
- GO2-87-218, Responds to NRC Re Violations Noted in Insp Rept 50-397/87-09.Corrective Actions:Matl Surveyed After Removal & Found to Have Exposure Rate Less than 10 M/H.Matl Bagged for Contamination Control + (11:33:31, 8 January 2025)
- IR 05000397/1987009 + (11:33:34, 8 January 2025)
- IR 05000397/1987015 + (11:33:39, 8 January 2025)
- ML17279A479 + (11:33:41, 8 January 2025)
- ML17279A476 + (11:33:42, 8 January 2025)
- ML17279A474 + (11:33:43, 8 January 2025)
- ML17279A472 + (11:33:44, 8 January 2025)
- 05000397/LER-1987-023, :on 870714,surveillance Procedures Associated W/Electrical Protection Assembly Breakers Not in Compliance W/Tech Spec Requirements.Caused by Personnel Error. Surveillance Procedures Revised + (11:33:46, 8 January 2025)
- ML17279A468 + (11:33:47, 8 January 2025)
- ML17279A466 + (11:33:48, 8 January 2025)
- ML17279A460 + (11:33:53, 8 January 2025)
- ML17279A457 + (11:33:54, 8 January 2025)
- GO2-87-226, Forwards Rev to Semiannual Effluent Rept for Jul-Dec 1986. Less than Indicator for Xe-138 Inadvertently Omitted from Table 3-3,Page 11 + (11:33:55, 8 January 2025)
- 05000397/LER-1987-022, :on 870706,reactor Scrammed on Low Reactor Water Level Due to Loss of Single Operating Reactor Feedwater (Turbine) Pump.Caused by Inadequate Procedures. Procedures Revised & Training Will Be Provided + (11:33:59, 8 January 2025)
- GO2-87-179, Forwards Response to Unresolved Items Noted in Insp Rept 50-397/87-02.Corrective Actions:Independent Insp by Consultants Confirmed That Detection Sys Meets Requirements for safety-related Areas + (11:34:01, 8 January 2025)
- IR 05000397/1987002 + (11:34:04, 8 January 2025)
- ML17279A440 + (11:34:06, 8 January 2025)
- ML17279A442 + (11:34:06, 8 January 2025)
- 05000397/LER-1987-020, :on 870702,reactor Scrammed.Caused by Motor Failure of Reactor Protection Sys (RPS) Motor Generator a Due to Ground Short & Broken Stop Tab on Stop Plate of RPS Power Supply Transfer Switch + (11:34:09, 8 January 2025)
- 05000397/LER-1987-018, :on 870626,reactor Automatically Scrammed by Reactor Protection Sys Actuation Due to Normal Auxiliary Power Transformer Sudden Pressure Relay Actuation.Caused by Opening of Test Valve.Transformers Inspected + (11:34:12, 8 January 2025)
- GO2-87-219, Responds to NRC Re Violations Noted in Insp Rept 50-397/87-14.Corrective Actions:Ltr Issued to Station & Contractor Personnel Re Employee Responsibility to Ensure That Plant Postings Maintained + (11:34:14, 8 January 2025)
- IR 05000397/1987014 + (11:34:18, 8 January 2025)
- ML17279A423 + (11:34:19, 8 January 2025)
- 05000397/LER-1987-017, :on 870623,RWCU Sys Automatically Isolated Due to High Differential Flow.Caused by Leakage Through Influent Isolation Valve for Filter Demineralizer Which Subjected Sys to High Pressure.Sys Returned to Svc + (11:34:29, 8 January 2025)
- ML17279A418 + (11:34:33, 8 January 2025)
- 05000397/LER-1987-016, :on 870622,control Room Emergency Filtration Sys Automatically Initiated Due to Failure of Trip Logic to Reset During Performance of Reactor Bldg Exhaust Radiation Monitor Surveillance Procedure.Cause Unknown + (11:34:38, 8 January 2025)
- ML17279A411 + (11:34:41, 8 January 2025)
- 05000397/LER-1987-015, :on 870620,Div 2 Drywell Pressure Monitoring Instrumentation Found Not Tracking Div 1 Since Instrument Rack Isolation Valves Closed.Caused by Inadequate Valve Labeling.Valves Opened & Instruments Operable + (11:34:44, 8 January 2025)
- IR 05000397/1987017 + (11:34:47, 8 January 2025)
- ML17279A398 + (11:34:49, 8 January 2025)
- 05000397/LER-1987-004, :on 870407,discovered Missed Fire Door Surveillance & Improper Identification of Fire Seal Penetrations.Caused by Inadequate Communication Between Two Architect Groups.Situation Rectified + (11:34:52, 8 January 2025)
- ML17279A393 + (11:34:54, 8 January 2025)
- ML17279A389 + (11:34:55, 8 January 2025)
- ML17279A385 + (11:34:56, 8 January 2025)
- ML17279A382 + (11:34:59, 8 January 2025)