Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- A05899, Documents 860703 Oral Comments on NRC Isap Review of Facility Operating History Through 1984.All Refs to FSAR Should Be Revised to Facility Description & Safety Analysis + (05:14:45, 8 December 2024)
- ML20203L312 + (05:14:45, 8 December 2024)
- ML20203L309 + (05:14:46, 8 December 2024)
- ML20203L307 + (05:14:50, 8 December 2024)
- ML20203L304 + (05:14:51, 8 December 2024)
- ML20203L302 + (05:14:52, 8 December 2024)
- ML20203L303 + (05:14:52, 8 December 2024)
- ML20203L301 + (05:14:53, 8 December 2024)
- ML20203L299 + (05:14:54, 8 December 2024)
- ML20203L298 + (05:14:57, 8 December 2024)
- 3F0886-02, Responds to NRC 860630 Nine Questions & 860731 Telcon Re SPDS & Suppl 1 to NUREG-0737 + (05:14:58, 8 December 2024)
- ML20203L293 + (05:15:03, 8 December 2024)
- BECO-86-118, Requests Withdrawal of 850909 Proposed Rod Worth Minimizer Tech Spec Change.If Change Necessary to Allow Startup from Refueling Outage 7,temporary Exemption Will Be Requested + (05:15:04, 8 December 2024)
- ML20203L291 + (05:15:04, 8 December 2024)
- NLS8600279, Advises That plant-unique Wetwell/Drywell Vacuum Breaker Structural Evaluation,Provided in ,Computed Stresses Due to Various Loadings & Concluded That Vacuum Breakers Met Design Requirements + (05:15:05, 8 December 2024)
- ML20203L289 + (05:15:06, 8 December 2024)
- ML20203L286 + (05:15:07, 8 December 2024)
- ML20203L287 + (05:15:07, 8 December 2024)
- ML20203L283 + (05:15:08, 8 December 2024)
- ML20203L284 + (05:15:08, 8 December 2024)
- ST-HL-AE-1724, Summarizes 860808 Meeting Between Nrc,Westinghouse & Util Re SER Open Item 16 & Confirmatory Item 13 Re long-term Cooling.Progress of Analysis Using Treat Computer Program Discussed.List of Attendees & Viewgraphs Encl + (05:15:09, 8 December 2024)
- ML20203L276 + (05:15:10, 8 December 2024)
- ML20203L280 + (05:15:10, 8 December 2024)
- HBL-86-026, Forwards Comments on Des for Decommissioning of Humboldt Bay Power Plant,Unit 3.Fission Chamber Strings Cut Up to Separate Chambers & Minimize Stored Waste Vol + (05:15:11, 8 December 2024)
- ML20203L275 + (05:15:11, 8 December 2024)
- ML20203L272 + (05:15:12, 8 December 2024)
- ML20203L271 + (05:15:13, 8 December 2024)
- ML20203L269 + (05:15:14, 8 December 2024)
- ML20203L267 + (05:15:21, 8 December 2024)
- ML20203L266 + (05:15:22, 8 December 2024)
- ML20203L265 + (05:15:24, 8 December 2024)
- IR 05000313/1986024 + (05:15:33, 8 December 2024)
- ML20203L260 + (05:15:34, 8 December 2024)
- ML20203L257 + (05:15:35, 8 December 2024)
- ML20203L256 + (05:15:36, 8 December 2024)
- 05000529/LER-1986-048, :on 860717,safety Injection Tanks (SIT) Inoperable Due to Wide Range Level Exceeding High Level Limit.Caused by Personnel Error.Order Stating Importance of SIT Level Monitoring During Heatup Issued + (05:15:38, 8 December 2024)
- 05000529/LER-1986-018-01, :on 860718,Tech Spec 3.0.3 Entered Due to Three Inoperable Charging Pumps.Charging Pumps a & B Taken Out of Svc for Repairs,Causing Pump E Gas Binding.Operations & Preventive Maint Procedures Revised + (05:15:41, 8 December 2024)
- ML20203L249 + (05:15:42, 8 December 2024)
- ML20203L248 + (05:15:43, 8 December 2024)
- B12211, Forwards Summaries of Preoperational & Startup Testing,Maint & Operation of Deep Draft Pumps,In Response to IE Bulletin 79-15 + (05:15:44, 8 December 2024)
- ML20203L245 + (05:15:45, 8 December 2024)
- ML20203L243 + (05:15:45, 8 December 2024)
- IR 05000443/1986098 + (05:16:10, 8 December 2024)
- ML20203L240 + (05:16:11, 8 December 2024)
- ML20203L237 + (05:16:15, 8 December 2024)
- ML20203L235 + (05:16:16, 8 December 2024)
- ML20203L233 + (05:16:17, 8 December 2024)
- ML20203L234 + (05:16:17, 8 December 2024)
- ML20203L232 + (05:16:18, 8 December 2024)
- ML20203L228 + (05:16:19, 8 December 2024)
- ML20203L230 + (05:16:19, 8 December 2024)