- 05000315/LER-1999-024, :on 990708,literal TS Requirements Were Not Met by Accumlator Valve Surveillance.Caused by Misjudgement Made in Conversion from Initial DC Cook TS to W Std Ts.Submitted License Amend Request.With + (18:16:54, 7 January 2025)
- ML17335A562 + (18:16:55, 7 January 2025)
- ML17335A563 + (18:16:55, 7 January 2025)
- ML17335A561 + (18:16:56, 7 January 2025)
- ML17335A559 + (18:16:56, 7 January 2025)
- ML17335A558 + (18:16:57, 7 January 2025)
- ML17335A555 + (18:16:58, 7 January 2025)
- ML17335A554 + (18:16:59, 7 January 2025)
- 05000315/LER-1999-023, :on 990907,inadequate TS Surveillance Testing of ESW Pump ESF Response Time Noted.Caused by Inadequate Understanding of Plant Design Basis.Surveillance Tests Will Be Revised & Implemented + (18:17:01, 7 January 2025)
- ML17335A549 + (18:17:04, 7 January 2025)
- ML17335A548 + (18:17:06, 7 January 2025)
- ML17335A546 + (18:17:07, 7 January 2025)
- ML17335A545 + (18:17:08, 7 January 2025)
- ML17335A544 + (18:17:09, 7 January 2025)
- ML17335A543 + (18:17:10, 7 January 2025)
- ML17335A541 + (18:17:11, 7 January 2025)
- ML17335A539 + (18:17:12, 7 January 2025)
- IR 05000315/1999008 + (18:17:16, 7 January 2025)
- ML17335A532 + (18:17:17, 7 January 2025)
- ML17335A531 + (18:17:19, 7 January 2025)
- ML17335A530 + (18:17:19, 7 January 2025)
- ML17335A529 + (18:17:20, 7 January 2025)
- ML17335A528 + (18:17:20, 7 January 2025)
- ML17335A524 + (18:17:21, 7 January 2025)
- ML17335A527 + (18:17:21, 7 January 2025)
- ML17335A520 + (18:17:23, 7 January 2025)
- ML17335A521 + (18:17:23, 7 January 2025)
- ML17335A519 + (18:17:24, 7 January 2025)
- 05000315/LER-1999-002, :on 990112,determined That RCS Pressurizer PORVs Had Not Been Tested,Per Ts.Caused by Inadequate Scheduling Controls Allowing Personnel Error.Surveillance Procedure Was Completed & Updated LER Will Be Submitted + (18:17:28, 7 January 2025)
- 05000315/LER-1999-001, :on 990106,noted That GE Hfa Relays Installed in EDGs May Not Meet Seismic Qualification.Caused by Operating Experience Info Incorrectly Dispositioned in 1985. Updated LER Will Be Submitted by 990405 + (18:17:31, 7 January 2025)
- IR 05000315/1998030 + (18:17:33, 7 January 2025)
- ML17335A508 + (18:17:35, 7 January 2025)
- IR 05000315/1998027 + (18:17:51, 7 January 2025)
- ML17335A505 + (18:17:53, 7 January 2025)
- ML17335A506 + (18:17:53, 7 January 2025)
- ML17335A503 + (18:17:55, 7 January 2025)
- ML17335A502 + (18:17:56, 7 January 2025)
- 05000315/LER-1998-060, :on 981231,identified That RT Sys Response Time Testing Did Not Comply with TS Definition.Caused by Inadequate Procedures.Corrective Actions Will Be Developed & Update to LER Will Be Submitted by 990415.With + (18:17:58, 7 January 2025)
- ML17335A500 + (18:17:58, 7 January 2025)
- IR 05000315/1998017 + (18:18:09, 7 January 2025)
- ML17335A497 + (18:18:10, 7 January 2025)
- 05000315/LER-1998-057, :on 981228,discovered That AFW Valves Were Not Tested IAW Inservice Testing Program.Caused by Failure to Recognize Design Bases Features Re Afws by Personnel. Updated LER Will Be Submittted by 990415.With + (18:18:12, 7 January 2025)