Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000272/LER-1990-028-01, :on 900814,Tech Spec 3.0.3 Entered Due to More than One Arpi Per Bank Inoperable.Caused by Sys Design.Sys Presently Under Consideration for Upgrade to Eliminate Temp Susceptibility of Coils + (08:06:10, 6 January 2025)
- 05000311/LER-1990-034, :on 900819,partial Main Steamline Isolation Occurred Due to Procedural Inadequacy.Applicable Procedures Revised by Adding Precautionary Statement.Event Reviewed by Operations Mgt + (08:06:13, 6 January 2025)
- 05000272/LER-1990-029-01, :on 900817,reactor Trip from 25% Power Occurred Due to Steam Generator lo-lo Level.Caused by Equipment Failure.Circuit Breaker Encl Positive Interlock Assembly Deficiencies Corrected + (08:06:16, 6 January 2025)
- ML18095A476 + (08:06:17, 6 January 2025)
- ML18095A475 + (08:06:19, 6 January 2025)
- 05000311/LER-1990-032, :on 900809,inservice Testing Program Discovered Not in Compliance.Caused by Inadequate Administrative Control.Review of Administrative Controls for Compliance W/Surveillance Frequency Changes Initiated + (08:06:21, 6 January 2025)
- 05000311/LER-1990-033, :on 900809,isolation Signals Received from Containment purge/pressure-vacuum Relief Sys & on 900824, Second ESF Signal Occurred.Caused by Design/Equipment. Channel 2R11A Repaired + (08:06:24, 6 January 2025)
- 05000272/LER-1990-026-01, :Several Occurrences of ASME Code 3 Piping Leakage Occurred Starting on 900611.Caused by Equipment Failure.All Affected Components Repaired Per ASME Code + (08:06:26, 6 January 2025)
- 05000272/LER-1990-027-01, :on 900812,main Steamline Isolation Actuation Occurred.Caused by Possible Equipment/Design Concerns. Design Mods to Correct Main Steamline Flow Instrumenation Concerns Under Development + (08:06:29, 6 January 2025)
- ML18095A469 + (08:06:31, 6 January 2025)
- IR 05000272/1990014 + (08:06:33, 6 January 2025)
- IR 05000272/1990019 + (08:09:32, 6 January 2025)
- ML18095A465 + (08:09:35, 6 January 2025)
- ML18095A464 + (08:09:36, 6 January 2025)
- ML18095A463 + (08:09:36, 6 January 2025)
- ML18095A462 + (08:09:37, 6 January 2025)
- ML18095A461 + (08:09:41, 6 January 2025)
- ML18095A459 + (08:09:42, 6 January 2025)
- ML18095A458 + (08:09:42, 6 January 2025)
- 05000311/LER-1990-031, :on 900802,valve 21MS18 Main Steam Line Isolation Control Circuit Failed to Close.Caused by Failure to Wire Control Circuitry Per design.Seal-in Contacts Removed from Circuit & Circuit Adjusted + (08:09:46, 6 January 2025)
- ML18095A455 + (08:09:48, 6 January 2025)
- ML18095A453 + (08:09:49, 6 January 2025)
- 05000272/LER-1990-025-01, :on 900806,control Room Air Intake Radiation Sys Monitor Alarm Circuitry Spiked High Resulting in Automatic Switching of Ventilation to Accident Mode of Operation.Addl Spikes Occurred on 900807 & 08 + (08:09:52, 6 January 2025)
- IR 05000272/1990021 + (08:09:54, 6 January 2025)
- ML18095A448 + (08:09:56, 6 January 2025)
- ML18095A447 + (08:09:58, 6 January 2025)
- ML18095A445 + (08:10:00, 6 January 2025)
- ML18095A442 + (08:10:01, 6 January 2025)
- ML18095A443 + (08:10:01, 6 January 2025)
- 05000272/LER-1990-024-01, :on 900728,discovered That Interlock Functions for P-10 & P-12 Permissives Not Fully Tested Per Tech Spec Surveillance 4.3.1.1.2.Caused by Inadequate Administrative Controls.Procedures Revised to Address Testing + (08:10:05, 6 January 2025)
- 05000272/LER-1990-023-01, :on 900725,discovered That Surveillance of Svc Water Sys Check Valves Not Completed Per Inservice Testing Program Manual Requirements.Caused by Inadequate Administrative Controls.Program Modified + (08:10:09, 6 January 2025)
- ML18095A439 + (08:10:11, 6 January 2025)
- ML18095A437 + (08:10:12, 6 January 2025)
- IR 05000272/1990200 + (08:10:13, 6 January 2025)
- ML18095A433 + (08:10:15, 6 January 2025)
- ML18095A434 + (08:10:15, 6 January 2025)
- ML18095A432 + (08:10:17, 6 January 2025)
- ML18095A431 + (08:10:18, 6 January 2025)
- ML18095A430 + (08:10:19, 6 January 2025)
- ML18095A429 + (08:10:20, 6 January 2025)
- TAC:67320 + (08:10:21, 6 January 2025)
- ML18095A427 + (08:10:21, 6 January 2025)
- ML18095A425 + (08:10:23, 6 January 2025)
- 05000272/LER-1990-021-01, :on 900717,discovered That Work Order Not Issued to Perform Revised Procedure 1IC-16.1.008.Caused by Personnel Error.Event Reviewed by Technical Department Mgt Appropriate Personnel + (08:10:26, 6 January 2025)
- ML18095A423 + (08:10:27, 6 January 2025)
- 05000272/LER-1989-035, :on 891210,containment Compressed Air Supply Valve Found Untagged in Open Position During Mode Changes. Caused by Personnel Error.Procedure IOP-2 Revised to Include Step to Verify Valve 1SA118 Closed + (08:10:29, 6 January 2025)
- 05000272/LER-1990-022-01, :on 900717,observed That Relief Valve 1SJ167 Was Leaking Past Seat as Result of Investigation to Determine Cause of Decreasing Level in Accumulators.Caused by Equipment Failure.Valve Repaired on 900722 + (08:10:33, 6 January 2025)
- ML18095A418 + (08:10:34, 6 January 2025)
- ML18095A416 + (08:10:35, 6 January 2025)
- ML18095A413 + (08:10:37, 6 January 2025)
- ML18095A415 + (08:10:37, 6 January 2025)