- PNO-II-79-043, on 791219,unit Reactor Tripped from 100% Power When Reactor Coolant Pump Motor a Failed.Steam Generator a Presssure Dropped & Safety Injection Occurred on High Steam Header Differential Pressure.Will Investigate + (02:41:53, 6 January 2025)
- ML18136A475 + (02:41:54, 6 January 2025)
- ML18136A474 + (02:41:55, 6 January 2025)
- ML18136A473 + (02:41:55, 6 January 2025)
- ML18136A471 + (02:41:57, 6 January 2025)
- IR 05000280/1979008 + (02:41:58, 6 January 2025)
- ML18136A468 + (02:41:59, 6 January 2025)
- 05000280/LER-1979-037-03, During Normal Operation, Routine Surveillance Revealed Failure of Heat Tracing Circuit 13A,1 & 2 Boron Injection Recirculation to Boric Acid Tanks.Caused by Excessive Heating of Heat Tracing Tape + (02:42:00, 6 January 2025)
- 05000280/LER-1979-035-03, Routine Surveillance Revealed Failure of Heat Tracing Circuit 2B,Unit 1 Suction Piping to Boric Acid Transfer Pump.Caused by Water Damage to Heat Tracing Circuit + (02:42:02, 6 January 2025)
- 05000280/LER-1979-031-03, While Reviewing Liquid Waste Release Forms,Discovered That Liquid Waste Monitor Did Not Alarm High & Trip Release Valve During 791117 Isotope Activity Release.Caused by Personnel Error + (02:42:04, 6 January 2025)
- ML18136A463 + (02:42:05, 6 January 2025)
- ML18136A461 + (02:42:06, 6 January 2025)
- ML18136A462 + (02:42:06, 6 January 2025)
- ML18136A459 + (02:42:07, 6 January 2025)
- ML18136A458 + (02:42:08, 6 January 2025)
- ML18136A457 + (02:42:08, 6 January 2025)
- IR 05000280/1979061 + (02:42:10, 6 January 2025)
- ML18136A455 + (02:42:11, 6 January 2025)
- ML18136A454 + (02:42:12, 6 January 2025)
- ML18136A453 + (02:42:13, 6 January 2025)
- ML18136A452 + (02:42:14, 6 January 2025)
- ML18136A449 + (02:42:15, 6 January 2025)
- ML18136A450 + (02:42:15, 6 January 2025)
- 05000280/LER-1980-008-01, /01T-0:on 800116,during Power Operation,Valve Inadvertently Closed,Preventing Boric Acid Flow in One of Two Flow Paths to Core for Approx 3-h.Caused Not Stated. Valve Opened & Boric Acid Flow Verified + (02:42:17, 6 January 2025)
- 05000280/LER-1980-008, Forwards LER 80-008/01T-0 + (02:42:18, 6 January 2025)
- ML18136A445 + (02:42:19, 6 January 2025)
- ML18136A444 + (02:42:20, 6 January 2025)
- ML18136A442 + (02:42:21, 6 January 2025)
- ML18136A441 + (02:42:22, 6 January 2025)
- ML18136A440 + (02:42:23, 6 January 2025)
- ML18136A439 + (02:42:23, 6 January 2025)
- 05000280/LER-1980-003-03, /03L-0:on 800107,during Prestartup Testing, Feedwater Bypass Valve HCV-FW-155B Did Not Fail Closed Upon Loss of Instrument Air as Per Design.Caused by Sticking, Dirty Pilot Valve.Valve Cleaned & Returned to Svc + (02:42:25, 6 January 2025)
- 05000280/LER-1980-002-03, /03L-0:on 800106,during Routine Release of Lwtt 80-95,LW Effluent Flow Recorder Paper Did Not Rotate & Thus No Record of Flow Note Was Obtained.Caused by Inadequate Mesh Between Recorder Drive Gears & Recorder Paper Roll + (02:42:27, 6 January 2025)
- ML18136A435 + (02:42:28, 6 January 2025)
- 05000280/LER-1980-001-03, /03L-0:on 800101,w/unit at Cold Shutdown,Snubber 1-WFPD-HSS-14 Found W/Empty Reservoir & Declared Inoperable Per Tech Spec.Caused by Leakage Around Pipe Nipple Threads on Valve Block & Extended Seal Washers.Snubber Replaced + (02:42:29, 6 January 2025)
- 05000280/LER-1980-001, Forwards LER 80-001/03L-0 + (02:42:31, 6 January 2025)
- ML18136A430 + (02:42:32, 6 January 2025)
- ML18136A426 + (02:42:33, 6 January 2025)
- OIG-16-A-15, Status of Recommendations: Independent Evaluation of Security of NRCs Publicly Accessible Web Applications Dated May 16, 2018 + (02:42:34, 6 January 2025)
- ML18136A424 + (02:42:36, 6 January 2025)
- ML18136A422 + (02:42:37, 6 January 2025)
- ML18136A421 + (02:42:38, 6 January 2025)
- ML18136A418 + (02:42:40, 6 January 2025)
- ML18136A420 + (02:42:40, 6 January 2025)
- ML18136A416 + (02:42:41, 6 January 2025)
- 05000280/LER-1979-043-03, /03L-0:on 791220,during Cold Shutdown,Radiation Recorder RR-175 Stopped Printing.Caused by Control String Disengaging from Drive Wheel.String Replaced + (02:42:43, 6 January 2025)
- ML18136A414 + (02:42:44, 6 January 2025)
- 05000280/LER-1979-043, Forwards LER 79-043/03L-0 + (02:42:49, 6 January 2025)
- 05000280/LER-1980-004-01, /01T-0:on 800108,during Routine Startup,Check Valve 1-FW-89 in Discharge Line of Auxiliary Feed Pump Stuck Open.Cause to Be Evaluated by Vendor.Feed Pump & Motor Operated Valves Cycled to Close Valve + (02:42:51, 6 January 2025)
- 05000280/LER-1980-004, Forwards LER 80-004/01T-0 + (02:42:53, 6 January 2025)
- ML18136A403 + (02:42:54, 6 January 2025)