- IR 05000327/1987017 + (06:49:27, 4 December 2024)
- ML20214J934 + (06:49:28, 4 December 2024)
- ML20214J932 + (06:49:29, 4 December 2024)
- ML20214J931 + (06:49:29, 4 December 2024)
- ML20214J930 + (06:49:30, 4 December 2024)
- RBG-24143, Requests Extension to 18-month Surveillance of Turbine Overspeed Protection Sys,Per Tech Spec 3/4.3.8,until 861004 to Correspond W/Next Scheduled Outage When Reactor in Mode 3,4 or 5 + (06:49:30, 4 December 2024)
- 05000320/LER-1986-006-02, :on 860715,discovered Contaminated Camera Tripod in Scrap Metal Dumpster in Unrestricted Area.Caused by Personnel Error.Tripod & Dumpster Decontaminated & Dumpster Resurveyed on 860716 + (06:49:32, 4 December 2024)
- ML20214J927 + (06:49:33, 4 December 2024)
- ML20214J926 + (06:49:33, 4 December 2024)
- 05000424/LER-1987-017, :on 870421,control Room Ventilation Actuation Occurred.Caused by Failure of I&C Technician to Block Test Signal While Performing Source Check.Technician & Foreman Counseled on Following Plant Procedure + (06:49:35, 4 December 2024)
- ML20214J923 + (06:49:36, 4 December 2024)
- ML20214J924 + (06:49:36, 4 December 2024)
- NL-86-301, Forwards Exercise Objectives & Extent of Play for Annual Emergency Exercise to Be Conducted on 861008,for Review & Comment + (06:49:38, 4 December 2024)
- ML20214J917 + (06:49:41, 4 December 2024)
- ML20214J916 + (06:49:42, 4 December 2024)
- IR 05000250/1986026 + (06:50:00, 4 December 2024)
- RBG-24145, Ro:On 860704,Div II Generator Failed During Surveillance Test.Caused by Lube Oil Leak on Turbocharger Bearing Feed Line.Oil Feed Line Changed Out + (06:50:01, 4 December 2024)
- ML20214J911 + (06:50:02, 4 December 2024)
- ML20214J909 + (06:50:02, 4 December 2024)
- ML20214J905 + (06:50:03, 4 December 2024)
- ML20214J906 + (06:50:03, 4 December 2024)
- ML20214J904 + (06:50:04, 4 December 2024)
- ML20214J903 + (06:50:05, 4 December 2024)
- U-600673, Forwards Request to Change Tech Spec Table 3.6.4-1, Containment Isolation Valves, by Adding Four Manual Isolation Valves to MSIV Leakage Control Sys & One Manual Isolation Valve to Equipment Hatch Penetration Seals + (06:50:05, 4 December 2024)
- IR 05000275/1987018 + (06:50:06, 4 December 2024)
- ML20214J896 + (06:50:07, 4 December 2024)
- ML20214J894 + (06:50:08, 4 December 2024)
- ML20214J891 + (06:50:08, 4 December 2024)
- IR 05000250/1986011 + (06:50:09, 4 December 2024)
- TXX-6113, Forwards Vols I & II of Comanche Peak Response Team Results Repts + (06:50:10, 4 December 2024)
- 05000324/LER-1986-016-01, :on 860711,automatic Scram Signal Occurred Due to Reactor Low Level During Warmup Flush of Unit RHR Loop B. Caused by Failure to Terminate Warmup Flush Prior to Reactor Level Decreasing to lo-lo Setpoint + (06:50:11, 4 December 2024)
- ML20214J881 + (06:50:12, 4 December 2024)
- ML20214J882 + (06:50:12, 4 December 2024)
- ML20214J878 + (06:50:13, 4 December 2024)
- ML20214J877 + (06:50:14, 4 December 2024)
- ML20214J874 + (06:50:15, 4 December 2024)
- ML20214J872 + (06:50:15, 4 December 2024)
- ML20214J868 + (06:50:16, 4 December 2024)
- ML20214J869 + (06:50:16, 4 December 2024)
- ML20214J867 + (06:50:17, 4 December 2024)
- 05000309/LER-1986-004, :on 860709,emergency Feedwater Pump Found Inoperable Due to Intermittent Contact of Charging Motor Secondary Coupler.Caused by Bent Coupler Pin Tip Which Prevented Connection.Coupler Replaced + (06:50:18, 4 December 2024)
- ML20214J864 + (06:50:19, 4 December 2024)
- ML20214J865 + (06:50:19, 4 December 2024)
- ML20214J862 + (06:50:20, 4 December 2024)
- IR 05000309/1987005 + (06:50:21, 4 December 2024)
- ML20214J860 + (06:50:21, 4 December 2024)
- PY-CEI-NRR-0656, Forwards Rept of Changes to Initial Test Program,Including Changes Made from 870427-0504.Changes Made in Accordance W/ License Condition 2.C(4) & 10CFR50.59 + (06:50:22, 4 December 2024)
- ML20214J857 + (06:50:23, 4 December 2024)
- ML20214J853 + (06:50:24, 4 December 2024)
- ML20214J852 + (06:50:24, 4 December 2024)
- ML20214J851 + (06:50:25, 4 December 2024)
- 05000374/LER-1986-011-01, :on 860601,feedwater Transient Occurred Causing Reactor Vessel Level to Drop to Level 3 Trip Setpoint.Caused by Failure of Reactor Vessel Level 3 Switches.Action Plan Has Been Developed + (06:50:27, 4 December 2024)