Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20059A626 + (22:10:27, 26 May 2025)
- ML20059A623 + (22:10:29, 26 May 2025)
- PNO-IV-93-029, on 931019,licensee Notified NRC of Unusual Event Re Accident Involving Worker Who Had Fallen from Crane While Working on Project to Remove Sludge from Clarifier Pond at Plant.Worker Clothing Potentially Contaminated + (22:10:31, 26 May 2025)
- ML20059A620 + (22:10:33, 26 May 2025)
- ML20059A617 + (22:10:34, 26 May 2025)
- ML20059A607 + (22:10:39, 26 May 2025)
- ML20059A605 + (22:10:40, 26 May 2025)
- ML20059A602 + (22:10:42, 26 May 2025)
- ML20059A597 + (22:10:44, 26 May 2025)
- ML20059A546 + (22:11:01, 26 May 2025)
- TAC:M85626 + (22:11:03, 26 May 2025)
- 05000133/LER-1993-001-02, :on 931124,specifies Missed Surveillance Due to Personnel Error.Caused by Surveillance Being Inadvertently Left Unscheduled.Instructions for Scheduling Replaced & Surveillance Reviewed + (22:11:39, 26 May 2025)
- ML20059A436 + (22:11:41, 26 May 2025)
- 05000413/LER-1993-010-02, :on 931123,discovered TS Test Interval for Surveillance Section 6.8.4 Not Met.Caused by Less than Adequate Mgt Direction.Procedures Changed & Review Performed to Determine If TS 4.0.2 Appropriately Applied + (22:11:43, 26 May 2025)
- ML20059A429 + (22:11:46, 26 May 2025)
- ML20059A425 + (22:11:48, 26 May 2025)
- ML20059A408 + (22:11:58, 26 May 2025)
- ML20059A407 + (22:12:00, 26 May 2025)
- ML20059A405 + (22:12:02, 26 May 2025)
- ML20059A401 + (22:12:07, 26 May 2025)
- 05000455/LER-1993-008-07, :on 931123,reactor Trip Occurred.Cause Suspected to Be Failure of One of Circuit Cards for Train a of Solid State Protection Sys SG Level.Suspect Circuit Cards Replaced + (22:12:09, 26 May 2025)
- ML20059A397 + (22:12:11, 26 May 2025)
- ML20059A396 + (22:12:12, 26 May 2025)
- ML20059A367 + (22:12:19, 26 May 2025)
- ML20059A358 + (22:12:25, 26 May 2025)
- IR 05000395/1990011 + (22:12:31, 26 May 2025)
- IR 05000528/1993026 + (22:13:07, 26 May 2025)
- IR 05000397/1993048 + (22:13:09, 26 May 2025)
- IR 05000295/1989200 + (22:13:11, 26 May 2025)
- IR 05000245/1992099 + (22:14:51, 26 May 2025)
- L-93-020, Forwards Revs to Security Plan for Pbaps,Units 1 & 2,per 10CFR50.54(p).Plan Withheld + (22:15:18, 26 May 2025)
- IR 05000309/1993026 + (22:16:00, 26 May 2025)
- ML20059A003 + (22:16:50, 26 May 2025)
- 05000443/LER-1993-017, :on 930914,determined That Configuration Entered During Performance of Check Valve Testing,Per Procedure OX1416.04 Represented Condition Prohibited by Ts. Caused by Procedural Inadequacy.Procedure OX1416.04 Revised + (22:17:54, 26 May 2025)
- 05000344/LER-1990-007, :on 900312,both Trains of Control Room Emergency Ventilation Sys Made Inoperable During Testing. Caused by Inadequate Control Over Work Activities.Event Will Be Discussed W/Personnel in Depts Involved + (22:18:38, 26 May 2025)
- IR 05000369/1990009 + (22:18:50, 26 May 2025)
- ML20058Q200 + (22:18:59, 26 May 2025)
- ML20058Q157 + (22:19:19, 26 May 2025)
- ML20058Q094 + (22:20:44, 26 May 2025)
- ML20058Q032 + (22:21:18, 26 May 2025)
- ML20058Q022 + (22:21:21, 26 May 2025)
- ML20058P999 + (22:21:27, 26 May 2025)
- IR 05000272/1992009 + (22:21:52, 26 May 2025)
- 05000440/LER-1993-009, :on 930325,containment Vessel & Drywell Purge Sys Isolation Occurred.Caused by Fuel Leakage Leading to High Iodine Loading on Rwcu.Hold Time Provision Built Into RWCU F/D Backwash Process + (22:21:58, 26 May 2025)
- TAC:M86770 + (22:22:26, 26 May 2025)
- IR 05000413/1990011 + (22:22:31, 26 May 2025)
- IR 05000289/1989082 + (22:22:52, 26 May 2025)
- ML20058P794 + (22:22:59, 26 May 2025)
- ML20058P793 + (22:23:00, 26 May 2025)
- ML20058P752 + (22:23:13, 26 May 2025)
- IR 05000458/1989200 + (22:23:26, 26 May 2025)