- TAC:M96542 + (16:40:15, 25 May 2025)
- IR 05000259/1996007 + (16:40:54, 25 May 2025)
- ML20129C584 + (16:44:25, 25 May 2025)
- ML20129C470 + (16:44:49, 25 May 2025)
- ML20129C212 + (16:46:13, 25 May 2025)
- TAC:M92883 + (16:46:30, 25 May 2025)
- ML20129C127 + (16:46:36, 25 May 2025)
- TAC:M86126 + (16:46:39, 25 May 2025)
- L-96-082, Provides Response to RAI Re Waste Shipments from Humboldt Bay Power Plant to Class 1 Hazardous Waste Land Disposal Sites in California + (16:47:43, 25 May 2025)
- ML20129B733 + (16:48:32, 25 May 2025)
- TAC:L22085 + (16:49:34, 25 May 2025)
- 05000315/LER-1985-023, :on 850502,definition of Auxiliary Bldg Crane Load Block as Being Heavy Load Not Emphasized in Plant Procedures.Cautions Will Be Added to Applicable Plant Procedures by 850615 + (16:50:28, 25 May 2025)
- TAC:M93648 + (16:53:57, 25 May 2025)
- ML20129A596 + (16:57:07, 25 May 2025)
- IR 05000010/1985003 + (16:59:05, 25 May 2025)
- ML20129A153 + (17:00:29, 25 May 2025)
- 05000423/LER-1996-034-01, :on 960918,RHR Pump Suction Rv Setpoint Was Not IAW Tss.Caused by Design Change Not Specifying That TS Change Was Required.Processed TS Change Request + (17:04:22, 25 May 2025)
- 05000245/LER-1996-037-01, Forwards Suppl LER 96-037-01,documenting 960327 Event at Millstone Nuclear Power Station,Unit 1.Committment 15756-1 Re Suppl Rept Due to on-going Engineering Evaluations for ADS Modified & Rev to Cycle 15 SBLOCA Analysis Add + (17:04:26, 25 May 2025)
- ML20128Q844 + (17:04:31, 25 May 2025)
- 05000317/LER-1995-005, :on 951109,manual Reactor Trip Occurred.Caused by Failure of Digital Feedwater Control Module FIC-1111. Reviewed Design Engineering Standards & Existing FP 2000 Digital Controllers Are Being Replaced + (17:04:45, 25 May 2025)
- ML20128Q767 + (17:04:50, 25 May 2025)
- ML20128Q764 + (17:04:52, 25 May 2025)
- ML20128Q738 + (17:05:06, 25 May 2025)
- ML20128Q729 + (17:05:10, 25 May 2025)
- ML20128Q710 + (17:05:15, 25 May 2025)
- ML20128Q696 + (17:05:20, 25 May 2025)
- ML20128Q631 + (17:05:34, 25 May 2025)
- NRC-96-0079, Requests Registration as User of Model CNS 8-120A,package USA/6601/A + (17:05:35, 25 May 2025)
- 05000237/LER-1985-020-02, :on 850424,during HPCI Steam Line High Flow Isolation Surveillance,Hpci Valve 2301-H Failed to Close. Caused by Dirty Breaker Auxiliary Contacts.Contacts Cleaned & Later Replaced + (17:05:41, 25 May 2025)
- IR 05000280/1991006 + (17:05:52, 25 May 2025)
- ML20128Q580 + (17:05:56, 25 May 2025)
- 05000311/LER-1985-006-01, :on 850423,reactor Trip Initiated When Turbine Lube Oil Cooler Placed in Svc.Caused by Lack of Procedural Guidance to Operators.Main Turbine Lubrication Oil Sys Operating Procedure Revised + (17:06:00, 25 May 2025)
- ML20128Q556 + (17:06:03, 25 May 2025)
- ML20128Q552 + (17:06:05, 25 May 2025)
- ML20128Q539 + (17:06:09, 25 May 2025)
- ML20128Q518 + (17:06:15, 25 May 2025)
- 05000352/LER-1985-046, :on 850423,w/unit in Cold Shutdown W/All Control Rods In,Reactor Full Scram Signal Occurred.Caused by Failure to Properly Remove Reactor Level Instrument from Svc.Use of Test Matrix Suggested + (17:06:19, 25 May 2025)
- ML20128Q504 + (17:06:20, 25 May 2025)
- ML20128Q486 + (17:06:25, 25 May 2025)
- ML20128Q478 + (17:06:29, 25 May 2025)
- 05000331/LER-1985-021, :on 850614,discovered That Spent Fuel Pool 5 Inches Below Tech Spec Level of 36 Ft.Caused by Small leak-through of Cask Pool Drain Valve.Maint Action Requests Initiated to Repair Valves + (17:09:32, 25 May 2025)
- ML20128Q396 + (17:09:39, 25 May 2025)
- ML20128Q371 + (17:09:47, 25 May 2025)
- ML20128Q359 + (17:09:53, 25 May 2025)
- ML20128Q302 + (17:10:07, 25 May 2025)
- ML20128Q294 + (17:10:10, 25 May 2025)
- 05000333/LER-1985-018, :on 850624,reactor Scram Occurred Due to Recirculation Flow Transient.Caused by Faulty Input Diode in Demodulator Board.Amplifier & Demodulator Board Replaced + (17:10:15, 25 May 2025)
- IR 05000219/1992025 + (17:15:02, 25 May 2025)
- IR 05000315/1990023 + (17:15:29, 25 May 2025)
- TAC:59930 + (17:16:25, 25 May 2025)
- IR 05000255/1993002 + (17:28:06, 25 May 2025)