0h' f
t g%s In Reply Refer To: 696-7074 GA Technologies Inc.
AN E C UFORNIA 92138 (619)455 3000 N
4Qy Dr. William T. Crow U.S. Nuclear Regulatory Commission Office of Nuclear Material Safety & Safeguards Washington, D.C. 20555 3
{
Subject:
Docket 70-734: SNM-696; Wipe and Meter Survey of Fuel Fabrication Facility, Building 37.
Dear Dr. Crow:
Attached is a Wipe and Meter Survey of Fuel T Mrication Facility, Building 37.
If there are any questions, please contact F. O. Bold, (619) 455-2020.
Very truly yours,
- Il b
^
gu ill am R. Mowry Licensing Administrator e
WRM:he
Attachment:
Wipe and Meter Survey of Fuel c
Fabrication Facility, Building 37 W
co p
.x Q
Os
(
O
-9
+;,fg
?
y u
~
4 l
TM,9{
/[
d 5
3'j Qlli 2 j
i 8507150070 850620 PDR ADOCM 07000734 C
PDR-i
A wipe and meter survey was recently completed in the HTGR Fuel Manu-facturing Production areas to determine external dose rates and the tactile alpha contamination level of floor areas.
Dose rate measurements were made using an Eberline RO-2 (33570).
If a general area dose rate exceeded 0.2 mR/hr, a "high" dose rate was de-termined. Dose rate r.easurements are listed in Attachment I.
Dose rate measurements were not made in the west or south vaults.
2 Wipe samples were collected on Whatman 41 filter paper of 1 ft areas.
The samples were submitted to the Healtg Physics Lab for analysis and the results were reported in dpm/100 cm.
Attachment II shows the average surface contamination in the various areas with the high sample result also listed.
Attachment I Dose Rate Measurements Gen. Area High Thorium Room Top 1.2 mR/hr 10 mR/hr South High Bay
<0.2 Old Coater
<0.2 North High Bay
<0.2 Dry Coater 0.2 2.2 Scrap Processing
<0.2 Dry Scrap 0.2 1.2 Fissile Beds 5
25 Fertile Beds 4
12 Fertile Bed Vacuum Pump 10 85 VSM 6
<0.2 North Mezz.
<0.2 South Mezz.
<0.2
.2 Fissile Mix Line
<0.2
e Attachment II Average Surface Contamination ( Alpha Activity) with High Sample Result dpm/100 cm2 High Wipe Average Fertile Mix Line 61 29 South High Bay 37 17 VSM 10-11 80 36 Old Coater 36 25 Old Coater Mezz.
17 9
North High Bay 17 12 Scrap Processing 28 19 Dry Coater 71 54 Dry Scrap 78 43 Fissile Beds 108 41 HCL 66 31 VSM-6 27 21 North Mezz.
42 21 South Mezz.
29 7
Fissile Mix Line 230 72 Carbonization Furnace 14 9
Desma Press Area 29 11 Carbonization Furnace
& Final Heat Treat 45 7
Vault Office & W st Vault 16 6
e Men's & Women's Change Room (Hot Side) 10 3
Decon Room 4 3...
12 l
l Total wipes taken in these areas - 225 i
i