Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19343C591 + (17:11:13, 24 December 2024)
- ML19343C592 + (17:11:13, 24 December 2024)
- 05000296/LER-1981-011-03, /03L-0:on 810224,coupling Damage Was Found on 3DA Rmov Bd MG Set.Caused by Misalignment & Loss of Lubricant.Coupling Seal Found Separated.Mg Set Realigned, Coupling Replaced & All Other Set Couplings Repaired + (17:11:15, 24 December 2024)
- 05000296/LER-1981-011, Forwards LER 81-011/03L-0 + (17:11:16, 24 December 2024)
- ML19343C587 + (17:11:18, 24 December 2024)
- ML19343C586 + (17:11:18, 24 December 2024)
- ML19343C585 + (17:11:19, 24 December 2024)
- ML19343C584 + (17:11:20, 24 December 2024)
- 05000302/LER-1981-012-03, /03L-0:on 810219,Limitorque-operated Containment Isolation Valves MUV-260 & 261 Failed to Close.Cause Unknown.Torque Switch MUV-261 Replaced & Operability Restored on 810224.Investigation Continuing + (17:11:22, 24 December 2024)
- ML19343C582 + (17:11:23, 24 December 2024)
- 05000302/LER-1981-012, Forwards LER 81-012/03L-0 + (17:11:24, 24 December 2024)
- 05000302/LER-1981-011-01, /01T-1:on 810306,containment Isolation Valves CAV-1,3,4,5 & 126 Found Incapable of Meeting Environ Qualification During Evaluation of IE Bulletin 79-01B.Caused by Potential Electrical Short Due to Flooding After LOCA + (17:11:26, 24 December 2024)
- ML19343C576 + (17:11:28, 24 December 2024)
- 05000302/LER-1981-011, Forwards LER 81-011/01T-1 + (17:11:29, 24 December 2024)
- 05000271/LER-1981-008-03, /03L-0:on 810218,reactor Core Isolation Cooling Pump Tripped.Caused by Electrical Cable Connector Detaching from Egr.Connector Replaced + (17:11:32, 24 December 2024)
- 05000271/LER-1981-008, Forwards LER 81-008/03L-0 + (17:11:33, 24 December 2024)
- ML19343C569 + (17:11:36, 24 December 2024)
- ML19343C566 + (17:11:39, 24 December 2024)
- ML19343C565 + (17:11:40, 24 December 2024)
- ML19343C564 + (17:11:41, 24 December 2024)
- ML19343C563 + (17:11:42, 24 December 2024)
- ML19343C560 + (17:11:43, 24 December 2024)
- ML19343C561 + (17:11:43, 24 December 2024)
- ML19343C559 + (17:11:44, 24 December 2024)
- ML19343C558 + (17:11:47, 24 December 2024)
- 05000296/LER-1980-056-03, /03L-0:on 801215,during Refueling,Diesel Generator Voltage Available Relay Found Dropped Out.Caused by Open Wire in Cable.Cable Replaced + (17:11:49, 24 December 2024)
- ML19343C556 + (17:11:50, 24 December 2024)
- ML19343C555 + (17:11:50, 24 December 2024)
- 05000296/LER-1980-056, Forwards LER 80-056/03L-0 + (17:11:52, 24 December 2024)
- ML19343C551 + (17:11:53, 24 December 2024)
- 05000296/LER-1980-057-03, /03L-0:on 801223,continuous Air Monitor 3-RM-90-251 Declared Inoperable.Caused by Improperly Set Detector High Voltage.Voltage Reset to Proper Peak & Personnel Cautioned + (17:11:54, 24 December 2024)
- ML19343C548 + (17:11:55, 24 December 2024)
- 05000325/LER-1981-038-03, /03L-0:on 810216,diesel Generator 2 Start Air Pressure Low Alarm Annunciated on Control Panel.Caused by 480-volt Breakers for Both Air Compressors for Generator in Off Position.Breakers Placed in on Position + (17:11:56, 24 December 2024)
- 05000312/LER-1981-012-01, /01T-0:on 810303,as-found Setpoints for High Reactor Bldg Pressure Trip Were Noted Exceeding Tech Spec. Caused by Instrument Drift.Switches Reset & Setpoints Revised + (17:11:58, 24 December 2024)
- 05000296/LER-1980-057, Forwards LER 80-057/03L-0 + (17:12:00, 24 December 2024)
- 05000312/LER-1981-012, Forwards LER 81-012/01T-0.Detailed Event Analysis Submitted + (17:12:02, 24 December 2024)
- 05000325/LER-1981-038, Forwards LER 81-038/03L-0 + (17:12:03, 24 December 2024)
- 05000259/LER-1981-009-01, /01T-0 on 810304,IE Info Notice 80-45 Evaluation Determined That Reactor Protection Sys for Units 2 & 3 Were Deficient Upon Loss of Power W/Subsequent Restoration.Caused by Design Deficiency.Caution Added to Instructions + (17:12:05, 24 December 2024)
- 05000312/LER-1981-011-03, /03L-0:on 810217,reactor Bldg Sump/Decay Heat Removal Sys Flow Path Obstructed.Caused by Installation of Blank Test Flanges on Suction Lines.Flanges Removed & Test Procedure Revised + (17:12:08, 24 December 2024)
- 05000312/LER-1981-011, Forwards LER 81-011/03L-0.Detailed Event Analysis Submitted + (17:12:10, 24 December 2024)
- ML19343C532 + (17:12:11, 24 December 2024)
- 05000333/LER-1981-022-03, /03L-0:on 810220,review Revealed Torus Water Level Recorders Had Not Been Included in Calibr Program Per 800123 Tech Specs Change.Caused by Personnel Error.Recorders Checked & Calibr Will Be Performed Once Each Six Months + (17:12:12, 24 December 2024)
- ML19343C530 + (17:12:14, 24 December 2024)
- 05000333/LER-1981-022, Forwards LER 81-022/03L-0 + (17:12:15, 24 December 2024)
- ML19343C527 + (17:12:16, 24 December 2024)
- 05000313/LER-1981-002-99, /99X-0:on 810303,during Steam Generator Tubing Surveillance Insp,First Sample Results on E24A Found Three Tubes Exceeded Plugging Limit.Cause Not Stated + (17:12:17, 24 December 2024)
- ML19343C525 + (17:12:18, 24 December 2024)
- ML19343C524 + (17:12:18, 24 December 2024)
- 05000313/LER-1981-002, Forwards LER 81-002/99X-0 + (17:12:20, 24 December 2024)
- ML19343C520 + (17:12:21, 24 December 2024)
- ML19343C518 + (17:12:24, 24 December 2024)
- ML19343C517 + (17:12:24, 24 December 2024)