- 05000317/LER-1980-040, Forwards LER 80-040/03L-0 + (15:54:25, 24 December 2024)
- ML19344F124 + (15:54:26, 24 December 2024)
- ML19344F123 + (15:54:27, 24 December 2024)
- 05000327/LER-1980-149-03, /03L-0:on 800807,during Preoperational Tests, Turbine Driven Feedwater Pump Failed to Maintain Rated Rpm. Caused by Overheated Automatic Governor.Ventilation Damper Linkage Repaired & Governor Controls Replaced + (15:54:31, 24 December 2024)
- ML19344F121 + (15:54:32, 24 December 2024)
- 05000327/LER-1980-139-03, /03L:on 800807,during Operation in Mode 2,B Train Transfer Switch for Component Cooling Water Pump Supply Tripped on Three Occasions.Caused by Thermal Overload Assembly.Switches Modified by Defeating Overload Features + (15:54:34, 24 December 2024)
- ML19344F119 + (15:54:35, 24 December 2024)
- ML19344F118 + (15:54:36, 24 December 2024)
- ML19344F117 + (15:54:37, 24 December 2024)
- ML19344F116 + (15:54:38, 24 December 2024)
- ML19344F114 + (15:54:39, 24 December 2024)
- ML19344F113 + (15:54:40, 24 December 2024)
- ML19344F112 + (15:54:41, 24 December 2024)
- ML19344F111 + (15:54:41, 24 December 2024)
- ML19344F110 + (15:54:42, 24 December 2024)
- ML19344F109 + (15:54:43, 24 December 2024)
- ML19344F107 + (15:54:44, 24 December 2024)
- 05000133/LER-1980-004-03, /03L-0:on 800807,screen Wash Pump Motor in Adjacent Fossil Unit Overheated & Breaker Would Not Trip. Caused by Breaker Wear & Inattention to Preventive Maint. Screen Wash Pump Breakers to Be Replaced + (15:54:46, 24 December 2024)
- ML19344F105 + (15:54:47, 24 December 2024)
- 05000327/LER-1980-139, Forwards LER 80-139/03L-0 + (15:54:50, 24 December 2024)
- 05000327/LER-1980-149, Forwards LER 80-149/03L-0 + (15:54:52, 24 December 2024)
- ML19344F097 + (15:54:55, 24 December 2024)
- 05000320/LER-1980-035-03, /03L-0:on 800731,during Recovery Mode Operation, Trouble Alarm Received in Control Room.Caused by Failed Flame Detectors within Balance of Plant Diesel Generator. Detector Replaced.Diesel Generators Removed from Specs + (15:54:57, 24 December 2024)
- ML19344F095 + (15:54:58, 24 December 2024)
- ML19344F091 + (15:55:01, 24 December 2024)
- 05000254/LER-1980-019-03, /03L-0:on 800817,while Operating at 400 Mw,After Performance of Reactor Core Isolation Cooling Monthly Pump Operability Surveillance Test,Flow Controller Was Left in Manual.Caused by Operator Failure to Readjust to Automatic + (15:55:05, 24 December 2024)
- ML19344F089 + (15:55:08, 24 December 2024)
- ML19344F088 + (15:55:08, 24 December 2024)
- ML19344F086 + (15:55:09, 24 December 2024)
- 05000254/LER-1980-019, Forwards LER 80-019/03L-0 + (15:55:10, 24 December 2024)
- ML19344F083 + (15:55:11, 24 December 2024)
- 05000255/LER-1980-030-03, /03L-0:on 800811,during Normal Operation, Discovered Indicating Lamps for CV-0437B & CV-0438B (Iodine Removal Sys Tanks Outlet Valves) Were Not Lit.Caused by Moisture in Junction Box Resulting in Blown Fuses + (15:55:12, 24 December 2024)
- ML19344F081 + (15:55:13, 24 December 2024)
- 05000334/LER-1980-047-03, /03L-0:on 800805,during Exercise Mode,Emergency Diesel Generator Output Circuit Breaker Failed to Close. Caused by Relay Latch Inoperability,Due to Dirty Contacts. After Replacing Contact Block,Diesel Tested Satisfactorily + (15:55:14, 24 December 2024)
- ML19344F079 + (15:55:15, 24 December 2024)
- 05000317/LER-1980-042-03, /03L-0:on 800806,during Normal Operation, Engineered Actuation Sys Channel Ze Was de-energized for Corrective Maint.Caused by Failure of Actuation Channel B Isolation Module within Channel Zd.Zd Module Replaced + (15:55:17, 24 December 2024)
- 05000334/LER-1980-047, Forwards LER 80-047/03L-0 + (15:55:19, 24 December 2024)
- ML19344F075 + (15:55:20, 24 December 2024)
- 05000325/LER-1980-055-03, /03L-0:on 800812,during Startup Preparations, Reactor Vessel Conductivity Measured Excessively High.Caused by Organics Breakdown in Reactor Vessel.Series of Condensate Makeup & Reject Operations Performed Using Charcoal Filt + (15:55:21, 24 December 2024)
- 05000278/LER-1980-018-03, /03L-0:on 800802,during Surveillance Test on PCIS Normally Open Valves W/Unit at Full Power,Reactor Water Cleanup Sys Return Isolation Valve MO-3-12-68 Failed to Close Using Control Switch.Cause Not Determined + (15:55:23, 24 December 2024)
- ML19344F071 + (15:55:26, 24 December 2024)
- 05000325/LER-1980-055, Forwards LER 80-055/03L-0 + (15:55:27, 24 December 2024)
- 05000333/LER-1980-071-03, /03L-0:on 800810,during Plant Startup at Less than 150 Psig,Reactor Core Isolation Cooling Turbine Speed Would Not Control in Manual During Surveillance Test.Sys Flow Also Did Not Control in Automatic.Cause Not Determined + (15:55:29, 24 December 2024)
- ML19344F067 + (15:55:30, 24 December 2024)
- ML19344F066 + (15:55:31, 24 December 2024)
- ML19344F064 + (15:55:32, 24 December 2024)
- 05000333/LER-1980-071, Forwards LER 80-071/03L-0 + (15:55:33, 24 December 2024)
- 05000317/LER-1980-042, Forwards LER 80-042/03L-0 + (15:55:36, 24 December 2024)
- 05000133/LER-1980-004, Forwards LER 80-004/03L-0 + (15:55:43, 24 December 2024)
- ML19344F053 + (15:55:46, 24 December 2024)
- ML19344F047 + (15:55:52, 24 December 2024)