Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20002A795 + (21:00:30, 23 December 2024)
- 05000296/LER-1980-044, Forwards LER 80-044/01T-0 + (21:00:31, 23 December 2024)
- ML20002A789 + (21:00:37, 23 December 2024)
- 05000267/LER-1980-058, Forwards LER 80-058/03L-0 + (21:00:38, 23 December 2024)
- ML20002A786 + (21:00:40, 23 December 2024)
- 05000267/LER-1980-057-03, /03L-0:on 801004,PCRV Pressure Exceeded Penetration Interspace Pressure.Caused by Malfunction of Pressure Switch.Pcrv pump-up Terminated & Switch Linkage Retightened & Calibr + (21:00:41, 23 December 2024)
- 05000249/LER-1980-038-03, /03L-0:on 801021,crack Was Found on Reactor Water Cleanup Heat Exchanger Equalizing Line (3-1292-2-A).Cause Unknown.Leak Was Temporarily Patched + (21:00:43, 23 December 2024)
- 05000267/LER-1980-057, Forwards LER 80-057/03L-0 + (21:00:45, 23 December 2024)
- 05000317/LER-1980-060-03, /03L-0:on 801018,surveillance Testing Found RC-200 & RC-201 Lift Setpoints to Be 70 Psi & 56 Psi,Respectively, Above Max Tech Spec.Cause Not Stated.Setpoints Adjusted + (21:00:46, 23 December 2024)
- 05000317/LER-1980-060, Forwards LER 80-060/03L-0 + (21:00:48, 23 December 2024)
- 05000293/LER-1980-075-03, /03L-0:on 790222 & 0807,fire Detection Alarms & Master Solenoid Relay Found Inoperable.Caused by Defective Wiring & Moisture.Wiring Changed & Detector Dried + (21:00:50, 23 December 2024)
- 05000293/LER-1980-075, Forwards LER 80-075/03L-0 + (21:00:51, 23 December 2024)
- 05000348/LER-1980-062-03, /03L-0:on 801017,diesel Generator Failed to Reach Rated Voltage within Tech Spec Time Limit,Voltage Could Not Be Controlled from Emergency Power Board & B1F Sequencer Step Six Was Below Setpoint.Cause Not Determined + (21:00:53, 23 December 2024)
- W3P80-0158, Forwards Response to FSAR Question 11.1,Asymmetric Loads, Requested by NRC at 801001 Draft SER Review Meeting.Requests That NRC Provide Prompt Review.Comments Received by 801201 Will Be Included in Amend + (21:00:54, 23 December 2024)
- ML20002A773 + (21:00:57, 23 December 2024)
- 05000348/LER-1980-061-01, /01T-0:on 801104,fire Protection Water Tanks a & B Fell Below Tech Spec Min Level During Flush on Unit 2 Fire Header.Caused by Equipment Operator Being Placed on Emergency Job & Missing Reading.Tanks Refilled + (21:00:58, 23 December 2024)
- ML20002A770 + (21:00:59, 23 December 2024)
- ML20002A769 + (21:01:00, 23 December 2024)
- 05000298/LER-1980-036-03, /03L-0:on 801003,valve RW-AO-95 Would Not Close within Time Limit.Caused by Miller-64A One Piston Air Operator,Which Is Valve Operator on Discharge Valve,Not Closing.Valve Tested Satisfactorily for Last Four Wks + (21:01:01, 23 December 2024)
- 05000298/LER-1980-036, Forwards LER 80-036/03L-0 + (21:01:03, 23 December 2024)
- 05000336/LER-1980-034-03, /03L-0:on 801017,turbine Driven Auxiliary Feedwater Pump P-4 Taken Out of Svc to Repair Drain Valve 2-MS-342.Caused by Steam Cut on Valve Seating Surface.Valve Seat Lapped & Disk Repaired + (21:01:05, 23 December 2024)
- 05000336/LER-1980-034, Forwards LER 80-034/03L-0 + (21:01:07, 23 December 2024)
- 05000259/LER-1980-078-03, /03L-0:on 801012,Tech Spec Limit of 13.32 Kw/Ft for Linear Heat Generation Rate Exceeded in Two Nodes.Caused by long-term Xenon Transient Following Preconditioning Ramp. Control Rod Insertion Restored Operation + (21:01:08, 23 December 2024)
- 05000259/LER-1980-078, Forwards LER 80-078/03L-0 + (21:01:10, 23 December 2024)
- 05000267/LER-1980-061-03, /03L-0:between 801003 & 13,on Three Occasions, Plant Operated W/Individual Snubbers Out of Svc.Caused by Need for Maint.One Snubber Filled W/Oil & Two Snubbers Adjusted + (21:01:12, 23 December 2024)
- 05000267/LER-1980-061, Forwards LER 80-061/03L-0 + (21:01:14, 23 December 2024)
- ML20002A756 + (21:01:15, 23 December 2024)
- ML20002A753 + (21:01:17, 23 December 2024)
- ML20002A750 + (21:01:19, 23 December 2024)
- ML20002A749 + (21:01:20, 23 December 2024)
- ML20002A748 + (21:01:20, 23 December 2024)
- ML20002A747 + (21:01:21, 23 December 2024)
- ML20002A745 + (21:01:22, 23 December 2024)
- IR 05000324/1980034 + (21:01:23, 23 December 2024)
- ML20002A743 + (21:01:27, 23 December 2024)
- ML20002A741 + (21:01:28, 23 December 2024)
- ML20002A742 + (21:01:28, 23 December 2024)
- 05000336/LER-1980-035-03, /03L-0:on 801016,fire Barrier Between Cable Spreading Room & East Containment Electrical Penetration Room Found Breached.Apparently Caused by Removal of Temporary Cables W/O Proper Sealing.Barrier Resealed + (21:01:29, 23 December 2024)
- 05000336/LER-1980-035, Forwards LER 80-035/03L-0 + (21:01:31, 23 December 2024)
- 05000368/LER-1980-080-03, /03L-0:on 801017,20,21 & 23,CEAC 2 Failed.Caused by Failure of Optical Isolator on First Three Days & Failure of Oxygen Pressure Module Card on Last Day.Optical Isolator & Oxygen Pressure Card Were Replaced + (21:01:33, 23 December 2024)
- 05000368/LER-1980-080, Forwards LER 80-080/03L-0 + (21:01:35, 23 December 2024)
- ML20002A731 + (21:01:39, 23 December 2024)
- IR 05000289/1980023 + (21:01:43, 23 December 2024)
- ML20002A726 + (21:01:45, 23 December 2024)
- ML20002A725 + (21:01:45, 23 December 2024)
- ML20002A722 + (21:01:46, 23 December 2024)
- ML20002A723 + (21:01:46, 23 December 2024)
- ML20002A721 + (21:01:47, 23 December 2024)
- ML20002A719 + (21:01:47, 23 December 2024)
- ML20002A717 + (21:01:50, 23 December 2024)
- IR 05000348/1980030 + (21:01:51, 23 December 2024)