- ML20004E804 + (15:42:28, 23 December 2024)
- ML20004E803 + (15:42:29, 23 December 2024)
- ML20004E801 + (15:42:34, 23 December 2024)
- ML20004E800 + (15:42:34, 23 December 2024)
- ML20004E799 + (15:42:35, 23 December 2024)
- ML20004E798 + (15:42:36, 23 December 2024)
- ML20004E797 + (15:42:39, 23 December 2024)
- ML20004E794 + (15:42:39, 23 December 2024)
- PNO-II-81-039, on 810602,water-steam Mixture Formed in Reactor Vessel Head Area W/Sys Vented While Reducing RCS Temp & Pressure to Achieve Cold Shutdown.Vent Closed & Temp & Pressure Levels Returned to Normal + (15:42:42, 23 December 2024)
- ML20004E792 + (15:42:42, 23 December 2024)
- ML20004E791 + (15:42:43, 23 December 2024)
- ML20004E790 + (15:42:44, 23 December 2024)
- ML20004E789 + (15:42:46, 23 December 2024)
- ML20004E788 + (15:42:47, 23 December 2024)
- ML20004E787 + (15:42:48, 23 December 2024)
- ML20004E786 + (15:42:49, 23 December 2024)
- ML20004E785 + (15:42:51, 23 December 2024)
- ML20004E781 + (15:42:52, 23 December 2024)
- ML20004E780 + (15:42:53, 23 December 2024)
- ML20004E776 + (15:42:54, 23 December 2024)
- ML20004E778 + (15:42:54, 23 December 2024)
- ML20004E772 + (15:42:55, 23 December 2024)
- ML20004E773 + (15:42:55, 23 December 2024)
- ML20004E771 + (15:42:57, 23 December 2024)
- 05000272/LER-1981-048-03, /03L-0:on 810514,Tech Spec Limit Containment Air Lock Leakage Rate Exceeded Design Pressure During Sp.Caused by Outer Door Seal Not Holding Pressure.Seals Repaired & Tested + (15:42:58, 23 December 2024)
- 05000272/LER-1981-048, Forwards LER 81-048/03L-0.Detailed Event Analysis Encl + (15:43:00, 23 December 2024)
- ML20004E767 + (15:43:02, 23 December 2024)
- 05000272/LER-1981-046-03, /03L-0:on 810512,required Cooling Water Flow Rate Not Obtained Resulting in Containment Fan Coil Unit 13 Stuck in Low Flow Position.Caused by Valve Stem Separated from Actuator Due to Cracked Trunnion Block Plug + (15:43:03, 23 December 2024)
- 05000272/LER-1981-046, Forwards LER 81-046/03L-0.Detailed Event Analysis Encl + (15:43:05, 23 December 2024)
- ML20004E763 + (15:43:07, 23 December 2024)
- ML20004E762 + (15:43:08, 23 December 2024)
- ML20004E760 + (15:43:09, 23 December 2024)
- ML20004E761 + (15:43:09, 23 December 2024)
- ML20004E759 + (15:43:11, 23 December 2024)
- ML20004E758 + (15:43:11, 23 December 2024)
- 05000245/LER-1981-009-03, /03L-0:on 810511,during Main Steam Line High Radiation Functional Test,Subchannel B Found to Trip Outside Acceptable Trip Setpoint Band.Caused by Instrument Setpoint Drift.Subchannel Recalibr & Tested + (15:43:13, 23 December 2024)
- 05000245/LER-1981-009, Forwards LER 81-009/03L-0 + (15:43:18, 23 December 2024)
- 05000338/LER-1981-028-03, /03L-0:on 810511,component Cooling Pipe Support & Snubber Removed Per Design Change 80-S46.Caused by Snubber Listed in Both Units 1 & 2 Tech Specs Although Installed on Unit 2 Piping of Common Sys.Snubber Deleted from Tech S + (15:43:20, 23 December 2024)
- IR 05000219/1981001 + (15:43:26, 23 December 2024)
- 05000338/LER-1981-028, Forwards LER 81-028/03L-0 + (15:43:28, 23 December 2024)
- ML20004E750 + (15:43:31, 23 December 2024)
- 05000272/LER-1981-047-03, /03L-0:on 810513,containment Air Lock Leak Rate Exceeded Design Pressure Tech Spec Limit During Sp.Caused by Outer Door Seal Not Holding Pressure.Seals Repaired & Tested + (15:43:32, 23 December 2024)
- ML20004E748 + (15:43:34, 23 December 2024)
- 05000272/LER-1981-047, Forwards LER 81-047/03L-0.Detailed Event Analysis Encl + (15:43:35, 23 December 2024)
- ML20004E745 + (15:43:36, 23 December 2024)
- 05000261/LER-1981-013-03, Determined Containment Isolation Valves Not Tested in Required Manner.Seven of Eight Valves Functioning as Designed.Eighth Valve Tested & Shown Operable.Test Undergoing Revision + (15:43:38, 23 December 2024)
- ML20004E742 + (15:43:39, 23 December 2024)
- 05000261/LER-1981-013, Forwards Updated LER 81-013/03L-1 + (15:43:41, 23 December 2024)
- 05000311/LER-1981-023-01, /01T-0:on 810522,main Steam Isolation Valves Failed to Close within Required 5-s During Startup Test. Caused by Design Error.Design Change Developed to Allow for Proper Interaction of Hydraulic & Steam Closing Subsys + (15:43:42, 23 December 2024)
- ML20004E738 + (15:43:44, 23 December 2024)
- 05000311/LER-1981-023, Forwards LER 81-023/01T-0.Detailed Event Analysis Encl + (15:43:45, 23 December 2024)