Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000369/LER-1981-065-03, /03L-0:on 810422,while in Mode 3 Initial Fuel Loading,Containment Floor & Equipment Sump Level Indicators in Control Room Failed to Zero Scale Position & Ac Power Supply Was Lost.Caused by Disconnected Wires + (15:15:42, 23 December 2024)
- ML20005A088 + (15:15:43, 23 December 2024)
- ML20005A087 + (15:15:44, 23 December 2024)
- 05000369/LER-1981-065, Forwards LER 81-065/03L-0 + (15:15:45, 23 December 2024)
- TXX-3349, Interim Deficiency Rept Re heating/ventilation/air- Conditioning Cooling Sys,Initially Reported on 810330.Cause Attributed to Design Evolution.Corrective Actions to Be Completed as Described in 810424 Interim Rept + (15:15:48, 23 December 2024)
- 05000369/LER-1981-039-03, /03L-0:on 810403,pressure Operated Relief Valve Found Lifting While in Automatic W/Associated Block Valve Closed.Caused by Low RCS Pressure Setpoint.Pressure Reduced & Valve Returned to Svc + (15:15:51, 23 December 2024)
- 05000369/LER-1981-039, Forwards LER 81-039/03L-0.Detailed Event Analysis Encl + (15:15:56, 23 December 2024)
- ML20005A080 + (15:15:58, 23 December 2024)
- ML20005A078 + (15:15:59, 23 December 2024)
- 05000369/LER-1981-037-03, /03L-0:on 810330,inadvertent Safety Injection Initiated During Initial Fuel Load Maint on Solid State Protection Sys Cabinets.Caused by Input Error Inhibit & Mode Selector Switches Left in on Position + (15:16:01, 23 December 2024)
- ML20005A075 + (15:16:03, 23 December 2024)
- ML20005A072 + (15:16:04, 23 December 2024)
- ML20005A073 + (15:16:04, 23 December 2024)
- ML20005A071 + (15:16:05, 23 December 2024)
- ML20005A070 + (15:16:06, 23 December 2024)
- 05000369/LER-1981-058-03, /03L-0:on 810418,while in Mode 3,lower Containment High Temp Alarm Was Received in Control Room Indicating That Units C & D Feeder Breakers Tripped.Caused by Incorrectly Adjusted Unit D Magnetic Overload Switch.Breaker Repla + (15:16:08, 23 December 2024)
- ML20005A068 + (15:16:10, 23 December 2024)
- 05000369/LER-1981-058, Forwards LER 81-058/03L-0 + (15:16:12, 23 December 2024)
- PNO-II-81-043, on 810616,plant Tripped Due to Offsite Power Loss.Caused by Lightning Strike on 230kv Feeder Line Supplying Startup Transformer.Testing Verified That No Damage Occurred.Transformer re-energized & Sys Restored + (15:16:14, 23 December 2024)
- ML20005A062 + (15:16:18, 23 December 2024)
- ML20005A063 + (15:16:18, 23 December 2024)
- ML20005A061 + (15:16:20, 23 December 2024)
- ML20005A060 + (15:16:21, 23 December 2024)
- 0CAN068108, Responds to Generic Ltr 81-07 Re NUREG-0612, Control of Heavy Loads.... Work on Interim Actions Completed.Extension of Select Response Dates Requested.Addl Info on Crane Design Compliance for Overhead Load Handling Sys Encl + (15:16:24, 23 December 2024)
- ML20005A056 + (15:16:24, 23 December 2024)
- ML20005A054 + (15:16:29, 23 December 2024)
- 05000321/LER-1981-051-03, /03L-0:810607,turbine Failed to Trip at Less than or Equal to 5,000 Rpm During Testing.Caused by Broken Turbine Trip Ball,Scored Trip Piston & Out of Calibr Diaphragm Oil Control Valve.Ball Replaced & Valve Cleaned + (15:16:31, 23 December 2024)
- ML20005A051 + (15:16:33, 23 December 2024)
- 05000369/LER-1981-064-03, /03L-0:on 810421,during Mode 3 Initial Fuel Loading,Wrong semi-daily Surveillance Item Checklists Run on Two Successive Shifts.Caused by Use of Wrong Procedures. Correct Checklist Completed & Personnel Cautioned + (15:16:34, 23 December 2024)
- 05000369/LER-1981-064, Forwards LER 81-064/03L-0 + (15:16:36, 23 December 2024)
- 05000369/LER-1981-063-03, /03L-0:on 810422,outer Door of Lower Personnel Air Lock Closed,But Locking Pins Stuck & Seals Failed to Inflate.Caused by Missing Shear Pin on Limit Switch Actuating Shaft.Pin Replaced & Door Declared Operable + (15:16:38, 23 December 2024)
- 05000321/LER-1981-051, Forwards LER 81-051/03L-0 + (15:16:40, 23 December 2024)
- 05000369/LER-1981-063, Forwards LER 81-063/03L-0 + (15:16:42, 23 December 2024)
- ML20005A042 + (15:16:43, 23 December 2024)
- ML20005A041 + (15:16:44, 23 December 2024)
- ML20005A039 + (15:16:45, 23 December 2024)
- 05000321/LER-1981-049-03, /03L-0:on 810605,reactor Core Isolation Cooling Valve Would Not Open by Control Switch During Testing.Caused by Relay Cover Binding on Logic Relay.Relay Cover Installed Correctly + (15:16:46, 23 December 2024)
- 05000369/LER-1981-059-03, /03L-0:on 810418,during Mode 3,while Settling Pond Water Being Released,Conventional Waste Water Discharge Flow Meter Strip Chart Recorder Did Not Match Meter Digital Readout.Caused by Switch Not Set to Level + (15:16:48, 23 December 2024)
- 05000321/LER-1981-049, Forwards LER 81-049/03L-0 + (15:16:50, 23 December 2024)
- 05000369/LER-1981-059, Forwards LER 81-059/03L-0.Detailed Event Analysis Encl + (15:16:52, 23 December 2024)
- ML20005A032 + (15:16:53, 23 December 2024)
- AECM-81-192, Final Deficiency Rept Re Seismically Unqualified 24-inch Starter/Breaker plug-in Drawers,Initially Reported on 810227.Drawers to Be Replaced W/Qualified Drawers of Varying Sizes + (15:16:54, 23 December 2024)
- ML20005A030 + (15:16:56, 23 December 2024)
- W3P81-1517, Forwards Matl Re SER Open Items 48, Reanalysis of Category 1 Structures & 49, Re-Evaluate Foundation Mat for Changes in Value of Subgrade Modulus + (15:16:58, 23 December 2024)
- ML20005A028 + (15:17:00, 23 December 2024)
- ML20005A026 + (15:17:02, 23 December 2024)
- ML20005A025 + (15:17:03, 23 December 2024)
- ML20005A023 + (15:17:04, 23 December 2024)
- ML20005A022 + (15:17:05, 23 December 2024)
- 05000369/LER-1981-066-03, /03L-0:on 810424,while in Mod 3,during Liquid Waste Release from Waste Monitor Tank,Chart Recorder Observed Not Functioning.Caused by Inadvertent Isolation of Flow Transmitter Associated W/Pump.Release Terminated + (15:17:06, 23 December 2024)
- 05000369/LER-1981-066, Forwards LER 81-066/03L-0.Detailed Event Analysis Encl + (15:17:08, 23 December 2024)