- 05000338/LER-1981-052-03, /03L-0:on 810709,fire Dampers Found Inoperable. Caused by Fusible Links Being Located Behind Damper & Not in Ventilation Air Flow Path.Mod Initiated to Position Links within Air Stream + (12:27:39, 21 December 2024)
- 05000260/LER-1981-041-03, /03L-0:on 810709,unit Crossconnect Capability Between Units 2 & 3 Reduced to One RHR Pump When RHR Pump 3C Became Inoperable.Caused by Pump Motor Failure on Ground Overcurrent During Testing + (12:27:41, 21 December 2024)
- ML20010A960 + (12:27:42, 21 December 2024)
- 05000338/LER-1981-052, Forwards LER 81-052/03L-0 + (12:27:43, 21 December 2024)
- ML20010A957 + (12:27:44, 21 December 2024)
- 05000260/LER-1981-041, Forwards LER 81-041/03L-0 + (12:27:46, 21 December 2024)
- ML20010A954 + (12:27:47, 21 December 2024)
- ML20010A952 + (12:27:49, 21 December 2024)
- 05000348/LER-1981-049-03, /03L-0:on 810714,A Train Containment Cooler 1B Was Declared Inoperable When Motor Operated Valve Failed to Open.Caused by Motor Operated Valve Motor Winding Failure. Motor Was Replaced & Containment Cooler Returned to Svc + (12:27:50, 21 December 2024)
- ML20010A948 + (12:27:54, 21 December 2024)
- 05000324/LER-1981-068-03, /03L-0:on 810715,reactor Coolant Conductivity Found Greater than Allowable Limits.Caused by Flange Leak in RWCU Sys Effluent Strainer Blowdown Line Which Necessitated Isolating Sys.Leak Repaired.Coolant Conductivity Reduced + (12:27:55, 21 December 2024)
- ML20010A945 + (12:27:57, 21 December 2024)
- ML20010A946 + (12:27:57, 21 December 2024)
- 05000324/LER-1981-068, Forwards LER 81-068/03L-0 + (12:27:59, 21 December 2024)
- 05000348/LER-1981-049, Forwards LER 81-049/03L-0 + (12:28:00, 21 December 2024)
- L-81-332, Interim Deficiency Rept Re Failure to Follow Radiographic Procedure,Initially Reported on 810312.Twenty-five Weld Joints Still Require Repair.Final Rept Will Be Submitted by 811030 + (12:28:01, 21 December 2024)
- 05000321/LER-1981-081-01, /01T-0:on 810729,w/steady State Operation at 99% Power,Bechtel Determined That RHRSW Piping Intake Structure Was Inadequately Supported.Caused by Inadequate Scsi Design. Addl Supports Have Been Designed & Installed + (12:28:07, 21 December 2024)
- 05000321/LER-1981-081, Forwards LER 81-081/01T-0 + (12:28:09, 21 December 2024)
- ML20010A935 + (12:28:11, 21 December 2024)
- ML20010A933 + (12:28:12, 21 December 2024)
- ML20010A932 + (12:28:13, 21 December 2024)
- 05000369/LER-1981-109-03, /03L-0:on 810705,air temp-Delta T Meteorological Monitoring Strip Chart Recorder Found Not Functioning Properly.Caused by Inkwell Shaft Binding W/Inkwell Bushing Causing Pointer to Chatter & Remain at One Point + (12:28:14, 21 December 2024)
- 05000369/LER-1981-109, Forwards LER 81-109/03L-0 + (12:28:16, 21 December 2024)
- 05000369/LER-1981-108-03, /03L-0:on 810705,vacuum Pump Seized Causing Loss of Flow Alarm on EMF-33 Monitor.Caused by Condensation Being Aspirated Into Vacuum Pump Due to Improper Drainage.Damaged Pump Repaired + (12:28:17, 21 December 2024)
- 05000369/LER-1981-108, Forwards LER 81-108/03L-0.Detailed Event Analysis Encl + (12:28:19, 21 December 2024)
- A01768, Submits Addl Info Re SEP Topic V-5,RCPB Leakage Detection. Assignment of Individual Sensitivity Criterion to Devices Such as Temp Detectors & Radiation Monitors Is Impractical & Can Not Be Quantified + (12:28:21, 21 December 2024)
- ML20010A920 + (12:28:23, 21 December 2024)
- ML20010A919 + (12:28:23, 21 December 2024)
- ML20010A918 + (12:28:24, 21 December 2024)
- ML20010A917 + (12:28:25, 21 December 2024)
- ML20010A913 + (12:28:26, 21 December 2024)
- ML20010A914 + (12:28:26, 21 December 2024)
- ML20010A912 + (12:28:27, 21 December 2024)
- ML20010A911 + (12:28:28, 21 December 2024)
- 05000369/LER-1981-112-03, /03L-0:on 810706,during Initial Testing of Composite Sampler for Containment Ventilation Unit Condensate Drain Tank Line,Flow Totalizer Indicated Greater than Actual Values.Caused by Leakage in Pneumatic Fitting + (12:28:29, 21 December 2024)
- 05000369/LER-1981-116-03, /03L-0:on 810709,safety Injection Sys Train B Was Declared Inoperable Due to Centrifugal Charging Pump Discharge Line That Would Not Cycle.Caused by Mixture of Oil & Water in Gear Case of Valve + (12:28:31, 21 December 2024)
- 05000369/LER-1981-112, Forwards LER 81-112/03L-0.Detailed Event Analysis Encl + (12:28:33, 21 December 2024)
- 05000369/LER-1981-116, Forwards LER 81-116/03L-0 + (12:28:34, 21 December 2024)
- 05000369/LER-1981-117-03, /03L-0:on 810710,firedoor Found Open & No Firewatch Was Posted.Caused by Personnel Working in Area Not Letting Operations Know That Door Was Open.Door Closed & Personnel Instructed + (12:28:36, 21 December 2024)
- 05000369/LER-1981-117, Forwards LER 81-117/03L-0 + (12:28:38, 21 December 2024)
- L-81-336, Interim Deficiency Rept Re Mounting of Allen Bradley Control Switches on Two Modutronic Control Panels,Initially Reported on 810624.Omitted Slot in Panel Prevented Insertion of Locking Ring.Final Rept Will Be Submitted by 810824 + (12:28:39, 21 December 2024)
- AECM-81-279, Final Deficiency Rept Re Matl Unqualified for FSAR Accident Conditions,Initially Reported on 810224.Response to Generic Issue Will Be Included in Response to NUREG-0588 + (12:28:41, 21 December 2024)
- ML20010A895 + (12:28:41, 21 December 2024)
- ML20010A893 + (12:28:44, 21 December 2024)
- ML20010A890 + (12:28:45, 21 December 2024)
- ML20010A891 + (12:28:45, 21 December 2024)
- ML20010A889 + (12:28:46, 21 December 2024)
- ML20010A887 + (12:28:47, 21 December 2024)
- ML20010A888 + (12:28:47, 21 December 2024)
- ML20010A886 + (12:28:48, 21 December 2024)
- ML20010A885 + (12:28:48, 21 December 2024)