Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20024D066 + (04:48:42, 21 December 2024)
- ML20024D064 + (04:48:43, 21 December 2024)
- ML20024D065 + (04:48:43, 21 December 2024)
- ML20024D063 + (04:48:44, 21 December 2024)
- ML20024D062 + (04:48:45, 21 December 2024)
- ML20024D061 + (04:48:45, 21 December 2024)
- ML20024D059 + (04:48:46, 21 December 2024)
- IR 05000333/1983008 + (04:48:47, 21 December 2024)
- 05000304/LER-1983-022-03, /03L-0:on 830626,steam Generator 2D Feedwater Flow Channel 2F-531 Observed Tracking Low.Caused by Transmitter 2FT-531 Drifting.Transmitter Replaced W/Spare & Replacement Being Evaluated + (04:48:49, 21 December 2024)
- ML20024D055 + (04:48:50, 21 December 2024)
- ML20024D054 + (04:48:52, 21 December 2024)
- ML20024D053 + (04:48:52, 21 December 2024)
- IR 05000266/1983012 + (04:48:53, 21 December 2024)
- 05000295/LER-1983-017-03, While at 78% Power & MSIV Partial Close Test (PT-3D) in Progress,High Steam Flow Safety Injection Occurred & MSIV 1D Found Open.Caused by MSIV Test Switch in Reset Position + (04:48:58, 21 December 2024)
- 05000321/LER-1983-063-03, /03L-0:on 830626,torus Water Level Indicator B (1T48-R622B) Found Indicating Erroneously.Caused by Sensing Line Being Full of Air Instead of Water Due to Packing Leak. Packing Tightened + (04:48:59, 21 December 2024)
- IR 05000263/1983014 + (04:49:01, 21 December 2024)
- ML20024D047 + (04:49:02, 21 December 2024)
- ML20024D045 + (04:49:03, 21 December 2024)
- AECM-83-0420, RO 83-059/0:on 830620,fire-rated Doors OC412 & OC712 to Reactor Protection Sys Motor Generator Set Rooms Blocked Open to Aid Room Ventilation.Fire Watch Established.Expected Restoration Date of Doors Is 830731 + (04:49:04, 21 December 2024)
- ML20024D044 + (04:49:04, 21 December 2024)
- ML20024D040 + (04:49:06, 21 December 2024)
- ML20024D039 + (04:49:07, 21 December 2024)
- 05000255/LER-1983-047-01, /01T-0:on 830712,w/safety Injection Tank T-82D inoperable,T-82B Became Inoperable Due Low Level.Caused by Leakage Past Fill & Drain Valve on Safety Injection Tank B.Repairs Will Be Made During Next Outage + (04:49:08, 21 December 2024)
- ML20024D037 + (04:49:09, 21 December 2024)
- ML20024D036 + (04:49:10, 21 December 2024)
- ML20024D033 + (04:49:11, 21 December 2024)
- ML20024D031 + (04:49:12, 21 December 2024)
- ML20024D029 + (04:49:12, 21 December 2024)
- ML20024D028 + (04:49:13, 21 December 2024)
- ML20024D025 + (04:49:14, 21 December 2024)
- ML20024D024 + (04:49:15, 21 December 2024)
- ML20024D022 + (04:49:16, 21 December 2024)
- ML20024D023 + (04:49:16, 21 December 2024)
- 1CAN078309, Withdraws Two Proposed Tech Spec Changes Re Low Temp Overpressure Protection & Change Requested by NRC as Result of IE Bulletins 79-05A,79-05B & 790517 Order + (04:49:17, 21 December 2024)
- ML20024D018 + (04:49:19, 21 December 2024)
- ML20024D013 + (04:49:20, 21 December 2024)
- 05000320/LER-1983-021-03, /03L-0:on 830616,while Performing 12-month Surveillance of Firewall-50 Fire Barrier Seals,Nine Seals Found to Be Nonfunctional.Caused by Dehydration Cracking,No Conduit Seals,Open Pull Boxes & Deformation + (04:49:34, 21 December 2024)
- ML20024D003 + (04:49:35, 21 December 2024)
- ML20024D002 + (04:49:36, 21 December 2024)
- ML20024C997 + (04:49:37, 21 December 2024)
- IR 05000302/1983011 + (04:49:39, 21 December 2024)
- ML20024C994 + (04:49:40, 21 December 2024)
- ML20024C993 + (04:49:40, 21 December 2024)
- ML20024C991 + (04:49:41, 21 December 2024)
- ML20024C984 + (04:49:42, 21 December 2024)
- ML20024C983 + (04:49:43, 21 December 2024)
- ML20024C981 + (04:49:44, 21 December 2024)
- ML20024C980 + (04:49:45, 21 December 2024)
- ML20024C979 + (04:49:47, 21 December 2024)
- IR 05000409/1983005 + (04:49:48, 21 December 2024)
- ML20024C975 + (04:49:49, 21 December 2024)