Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20032A441 + (17:19:58, 20 December 2024)
- ML20032A440 + (17:20:01, 20 December 2024)
- ML20032A439 + (17:20:02, 20 December 2024)
- ML20032A438 + (17:20:05, 20 December 2024)
- ML20032A437 + (17:20:06, 20 December 2024)
- ML20032A436 + (17:20:07, 20 December 2024)
- ML20032A434 + (17:20:08, 20 December 2024)
- ML20032A432 + (17:20:12, 20 December 2024)
- ML20032A431 + (17:20:16, 20 December 2024)
- 05000325/LER-1981-060, Updated LER 81-060/03L-1:on 810827 & 0915,reviews Revealed That Engineering Suppression Chamber Visual & Fire Protection Insps Were Not Performed within Tolerance Dates. Caused by Failure to Enter Insps in Master Schedule + (17:20:21, 20 December 2024)
- ML20032A428 + (17:20:23, 20 December 2024)
- AECM-81-404, Final Deficiency Rept Re Discrepant Slopes in Instrument Process Tubing,Initially Reported on 801230.Also Reportable Per Part 21.Tubing Installations Have Been Redesigned.Specs Revised to Clarify Slope Requirements + (17:20:25, 20 December 2024)
- ML20032A424 + (17:20:28, 20 December 2024)
- 05000321/LER-1981-106-03, /03L-0:on 810928,while Performing Diesel Generator Manual Start,Generator 1R43-S001B Started But Voltage Could Not Be Controlled W/Adjust Switch.Caused by Failure of Diodes in Voltage Regulator Circuit.Diodes Replaced + (17:20:30, 20 December 2024)
- ML20032A421 + (17:20:33, 20 December 2024)
- 1CAN108104, Forwards Emergency Feedwater Sys Upgrade Reliability Analysis + (17:20:34, 20 December 2024)
- ML20032A418 + (17:20:36, 20 December 2024)
- PNO-V-81-058, on 811025,during Insp of 4160-volt Switchgear Room,Fire Barrier Foam Matl Observed on Floor Near Electrical Cabinets.Caused by Failure During Installation to Seal Openings at Top of Cabinet + (17:20:38, 20 December 2024)
- 05000285/LER-1981-009-03, /03L-0:on 810924,during Shutdown,Cooling Fan/Coil Placed in Svc for Containment Air Cooling.Pressurized Leak Developed When Coil End Plug Blew Out.Caused by Stripped Threads on Loosely Installed Thread End Plug + (17:20:43, 20 December 2024)
- 05000321/LER-1981-106, Forwards LER 81-106/03L-0 + (17:20:45, 20 December 2024)
- 05000260/LER-1981-045-03, /03L-0:on 810916,during Scram,When Manually Initiated,Hpci Gland Seal Condenser Upper Head Gasket Began Leaking.Caused by Head Gasket Stretching Out of Place Due to Overpressurization.Gasket Replaced + (17:20:47, 20 December 2024)
- ML20032A409 + (17:20:49, 20 December 2024)
- 05000285/LER-1981-009, Forwards LER 81-009/03L-0 + (17:20:50, 20 December 2024)
- 05000334/LER-1981-082, Forwards LER 81-082/01T-0 + (17:20:53, 20 December 2024)
- 05000324/LER-1981-103-03, /03L-0:on 810921,primary Containment Atmospheric Oxygen analyzer,2-CAC-AT-1259-2,model F3M3,observed Showing Upscale Indication of Torus Oxygen Concentration.Caused by Moisture Buildup in Monitor Torus Sample Line + (17:20:59, 20 December 2024)
- 05000260/LER-1981-045, Forwards LER 81-045/03L-0 + (17:21:01, 20 December 2024)
- 05000346/LER-1981-058, Forwards LER 81-058/01T-0 + (17:21:06, 20 December 2024)
- ML20032A397 + (17:21:07, 20 December 2024)
- 05000266/LER-1981-015-01, /01T-0:on 811010,during Refueling Outage,High & Low Head Safety Injection Check Valve Leakage Test Indicated Excessive Leakage.Cause Not Stated.Affected Line Flushed & Passed Retest + (17:21:09, 20 December 2024)
- 05000324/LER-1981-103, Forwards LER 81-103/03L-0 + (17:21:11, 20 December 2024)
- ML20032A389 + (17:21:16, 20 December 2024)
- 05000339/LER-1981-077-03, /03L-0:on 810920,axial Flux Difference Deviated Greater than 5% from Target for Max Duration of One Minute While Returning to Full Power Following Reactor Trip.Caused by Xenon Instability During Recovery from Reactor Trip + (17:21:18, 20 December 2024)
- ML20032A384 + (17:21:21, 20 December 2024)
- ML20032A382 + (17:21:22, 20 December 2024)
- IR 05000373/1981035 + (17:21:23, 20 December 2024)
- 05000339/LER-1981-077, Forwards LER 81-077/03L-0 + (17:21:26, 20 December 2024)
- ML20032A375 + (17:21:28, 20 December 2024)
- ML20032A373 + (17:21:29, 20 December 2024)
- 05000325/LER-1981-066-03, /03L-0:on 810925,while Running HPCI Sys Auxiliary Oil Pump in Accordance W/Surveillance Requirements,Local Insp Showed Pump Was Uncoupled from Motor.Caused by Misalignment of Coupling in Initial Unit Startup + (17:21:30, 20 December 2024)
- ML20032A371 + (17:21:32, 20 December 2024)
- ML20032A370 + (17:21:33, 20 December 2024)
- ML20032A369 + (17:21:34, 20 December 2024)
- ML20032A368 + (17:21:36, 20 December 2024)
- 05000260/LER-1981-048-03, /03L-0:on 810921,during Normal Operation,Flow Totalizer FQ-68-5 Drifted High Causing Erroneous Flow Indication to Average Power Range Monitor Channels.Caused by Electronic Failure.Totalizer Replaced + (17:21:37, 20 December 2024)
- 05000325/LER-1981-066, Forwards LER 81-066/03L-0 + (17:21:39, 20 December 2024)
- ML20032A364 + (17:21:41, 20 December 2024)
- IR 05000341/1981015 + (17:21:45, 20 December 2024)
- ML20032A361 + (17:21:47, 20 December 2024)
- ML20032A359 + (17:21:48, 20 December 2024)
- 05000260/LER-1981-048, Forwards LER 81-048/03L-0 + (17:21:49, 20 December 2024)
- ML20032A355 + (17:21:51, 20 December 2024)