- 05000302/LER-1981-064-03, /03L-0:on 811007,while Performing Engineered Safeguards Channel Calibr,Esf Actuation Sys Reactor Coolant Pressure Transmitter RC-2A-PT3 Discovered Out of Tolerance. Caused by Instrument Drift.Instrument Recalibr + (16:27:09, 20 December 2024)
- ML20032D068 + (16:27:10, 20 December 2024)
- ML20032D067 + (16:27:11, 20 December 2024)
- ML20032D066 + (16:27:13, 20 December 2024)
- ML20032D065 + (16:27:17, 20 December 2024)
- ML20032D064 + (16:27:18, 20 December 2024)
- ML20032D062 + (16:27:19, 20 December 2024)
- 05000302/LER-1981-064, Forwards LER 81-064/03L-0 + (16:27:20, 20 December 2024)
- ML20032D059 + (16:27:22, 20 December 2024)
- ML20032D058 + (16:27:23, 20 December 2024)
- 05000302/LER-1981-063-03, /03L-0:on 811005, 12 & 14,various Snubbers Discovered Inoperable.Snubber EFH-106 Failed Due to Bent shaft.RCH-53 & 85 Had Cracked Aluminum bushings.DHR-28, MSH-253 & MUH-46A Failed Due to Excessive Bleed Rate + (16:27:24, 20 December 2024)
- ML20032D056 + (16:27:28, 20 December 2024)
- ML20032D055 + (16:27:29, 20 December 2024)
- 05000302/LER-1981-063, Forwards LER 81-063/03L-0 + (16:27:31, 20 December 2024)
- ML20032D052 + (16:27:34, 20 December 2024)
- ML20032D049 + (16:27:35, 20 December 2024)
- IR 05000309/1981017 + (16:27:38, 20 December 2024)
- ML20032D044 + (16:27:43, 20 December 2024)
- ML20032D042 + (16:27:44, 20 December 2024)
- 05000259/LER-1981-061-03, /03L-0:on 811010,diesel Generator C Shut Down Prior to Normal Time Frame to Troubleshoot & Time ECR Relay. Cause Undetermined.Ecr Relay Calibr & Time Acceptable + (16:27:45, 20 December 2024)
- ML20032D040 + (16:27:47, 20 December 2024)
- 05000269/LER-1981-019-01, /01T-0:on 811019 & 20,four Liquid Waste Releases Made W/Inoperable Effluent Monitors & Inadequate Redundant Samples of Water Releases.Caused by Failure to Identify Change in Sample Point.Sampling Procedure Revised + (16:27:49, 20 December 2024)
- 05000259/LER-1981-061, Forwards LER 81-061/03L-0 + (16:27:51, 20 December 2024)
- 05000293/LER-1981-059, Forwards LER 81-059/03L-0 + (16:27:53, 20 December 2024)
- ML20032D034 + (16:27:55, 20 December 2024)
- 05000336/LER-1981-035-03, /03L-0:on 811008,found Pressurizer Water Level & Auxiliary Feedwater Flow Rate Channel Checks Not Performed During Aug & Sept 1981.Caused by Failure to Incorporate Changes When Procedure Form Was Revised + (16:27:56, 20 December 2024)
- IR 05000416/1981038 + (16:27:58, 20 December 2024)
- ML20032D029 + (16:28:00, 20 December 2024)
- 05000336/LER-1981-035, Forwards LER 81-035/03L-0 + (16:28:02, 20 December 2024)
- 05000311/LER-1981-109-03, /03L-0:on 811006,while Performing Design Change Package Mods,Vitro Labs Representative Allowed Solder to Fall Into 15-volt Power Supply for 2A Safeguards Equipment Control.Caused by Personnel Error.Power Supply Replaced + (16:28:05, 20 December 2024)
- ML20032D025 + (16:28:07, 20 December 2024)
- ML20032D023 + (16:28:08, 20 December 2024)
- ML20032D022 + (16:28:10, 20 December 2024)
- 05000311/LER-1981-109, Forwards LER 81-109/03L-0.Detailed Event Analysis Encl + (16:28:11, 20 December 2024)
- ML20032D019 + (16:28:13, 20 December 2024)
- ML20032D018 + (16:28:14, 20 December 2024)
- ML20032D017 + (16:28:15, 20 December 2024)
- ML20032D016 + (16:28:17, 20 December 2024)
- ML20032D015 + (16:28:18, 20 December 2024)
- ML20032D014 + (16:28:19, 20 December 2024)
- ML20032D013 + (16:28:20, 20 December 2024)
- ML20032D012 + (16:28:21, 20 December 2024)
- ML20032D010 + (16:28:23, 20 December 2024)
- ML20032D009 + (16:28:24, 20 December 2024)
- 05000336/LER-1981-034-03, /03L-0:on 811008,routine Surveillance Indicated Excore Detector Channel D Had Potentiometer in Core Protection Calculator That Was Set Nonconservatively.Caused by New Detector W/Improper Setting + (16:28:26, 20 December 2024)
- ML20032D006 + (16:28:28, 20 December 2024)
- ML20032D004 + (16:28:29, 20 December 2024)
- 05000302/LER-1981-065-03, /03L-0:on 811008,during Performance of Remote Shutdown Instrumentation Calibr,Transmitters SP-1A-LT2 & SP-1B-LT2 Found Out of Tolerance.Caused by Instrument Drift. Instruments Recalibr + (16:28:30, 20 December 2024)