Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20032E172 + (15:56:53, 20 December 2024)
- PNO-V-81-065, on 811030,during Review of Installation Measurement Data,Reactor Vessel Core Support Barrel Discovered Misoriented 180 Degrees.Caused by Insufficient Vessel Internals Orientation & Nuclear as-built Drawings + (15:56:55, 20 December 2024)
- ML20032E170 + (15:56:56, 20 December 2024)
- ML20032E168 + (15:57:02, 20 December 2024)
- ML20032E165 + (15:57:03, 20 December 2024)
- ML20032E162 + (15:57:06, 20 December 2024)
- IR 05000315/1981013 + (15:57:07, 20 December 2024)
- 05000263/LER-1981-021-01, /01T-0:on 811024,during Cold Shutdown Primary Containment Isolation Sys Logic Relay Coil Failed & Relay Did Not Immediately Trip.Caused by Natural end-of-life. Replaced Relay + (15:57:09, 20 December 2024)
- ML20032E158 + (15:57:10, 20 December 2024)
- ML20032E157 + (15:57:11, 20 December 2024)
- ML20032E156 + (15:57:13, 20 December 2024)
- ML20032E155 + (15:57:14, 20 December 2024)
- ML20032E154 + (15:57:15, 20 December 2024)
- ML20032E150 + (15:57:17, 20 December 2024)
- ML20032E149 + (15:57:18, 20 December 2024)
- 05000346/LER-1981-041-01, /01T-1:on 810805,C & HP Notified Supervisor That RCS Boron Concentration Decreased from 1044 Ppm to 970 Ppm. Caused by Placing Purification Demineralizer in Svc, Previously Saturated at 432-ppm Boron.Boric Acid Added + (15:57:19, 20 December 2024)
- ML20032E147 + (15:57:21, 20 December 2024)
- ML20032E146 + (15:57:22, 20 December 2024)
- ML20032E145 + (15:57:23, 20 December 2024)
- 05000346/LER-1981-041, Forwards LER 81-041/01T-1 + (15:57:25, 20 December 2024)
- ML20032E142 + (15:57:27, 20 December 2024)
- ML20032E141 + (15:57:28, 20 December 2024)
- ML20032E140 + (15:57:29, 20 December 2024)
- ML20032E139 + (15:57:30, 20 December 2024)
- ML20032E137 + (15:57:31, 20 December 2024)
- ML20032E135 + (15:57:32, 20 December 2024)
- ML20032E134 + (15:57:33, 20 December 2024)
- ML20032E133 + (15:57:34, 20 December 2024)
- ML20032E132 + (15:57:35, 20 December 2024)
- ML20032E131 + (15:57:36, 20 December 2024)
- ML20032E130 + (15:57:36, 20 December 2024)
- ML20032E129 + (15:57:37, 20 December 2024)
- ML20032E128 + (15:57:37, 20 December 2024)
- ML20032E127 + (15:57:38, 20 December 2024)
- ML20032E125 + (15:57:39, 20 December 2024)
- ML20032E126 + (15:57:39, 20 December 2024)
- ML20032E123 + (15:57:40, 20 December 2024)
- ML20032E124 + (15:57:40, 20 December 2024)
- ML20032E122 + (15:57:42, 20 December 2024)
- ML20032E121 + (15:57:42, 20 December 2024)
- IR 05000331/1981003 + (15:58:10, 20 December 2024)
- ML20032E119 + (15:58:11, 20 December 2024)
- ML20032E118 + (15:58:12, 20 December 2024)
- ML20032E117 + (15:58:12, 20 December 2024)
- ML20032E114 + (15:58:14, 20 December 2024)
- ML20032E115 + (15:58:14, 20 December 2024)
- ML20032E112 + (15:58:16, 20 December 2024)
- ML20032E113 + (15:58:16, 20 December 2024)
- ML20032E111 + (15:58:17, 20 December 2024)
- ML20032E110 + (15:58:18, 20 December 2024)
- 05000254/LER-1981-017-03, /03-0:on 811009,during Reactor Fuel Pool Monitor Test of Downscale Trip,A Monitor Found Out of Calibr.Caused by Instrument Setpoint Drift.Monitor Recalibr + (15:58:19, 20 December 2024)