- ML20040E635 + (02:25:41, 20 December 2024)
- 05000369/LER-1981-193-03, /03L-0:on 811224,technicians Initiated Low Steam Line Pressure Safety Injection Actuation on Both Trains. Caused by Procedural Deficiency.Procedure to Be Corrected by 820122 + (02:25:45, 20 December 2024)
- IR 05000416/1981055 + (02:25:48, 20 December 2024)
- 05000302/LER-1981-083, Forwards LER 81-083/03L-0 + (02:25:50, 20 December 2024)
- ML20040E630 + (02:25:52, 20 December 2024)
- 05000369/LER-1981-193, Forwards LER 81-193/03L-0.Detailed Event Analysis Encl + (02:25:54, 20 December 2024)
- ML20040E626 + (02:25:55, 20 December 2024)
- ML20040E625 + (02:25:56, 20 December 2024)
- PNO-II-82-014, on 820130,reactor Coolant Pump Seal Found Leaking Excessively.Cause Not Stated.Backup Seal Placed in Svc.Maint Outage Advanced to Coincide W/Repairs + (02:25:58, 20 December 2024)
- ML20040E622 + (02:25:59, 20 December 2024)
- IR 05000309/1981019 + (02:26:01, 20 December 2024)
- ML20040E619 + (02:26:02, 20 December 2024)
- ML20040E617 + (02:26:04, 20 December 2024)
- ML20040E616 + (02:26:04, 20 December 2024)
- IR 05000413/1981028 + (02:26:06, 20 December 2024)
- ML20040E613 + (02:26:08, 20 December 2024)
- 05000327/LER-1981-160-03, /03L-0:on 811231,w/unit in Mode 1,essential Raw Cooling Water Line Radiation Monitor O-RM-90-134/141 Was Declared Inoperable.High Radiation Alarm Caused by Unknown Noise Source.Monitor Checked + (02:26:09, 20 December 2024)
- ML20040E608 + (02:26:11, 20 December 2024)
- ML20040E605 + (02:26:12, 20 December 2024)
- ML20040E606 + (02:26:12, 20 December 2024)
- 05000327/LER-1981-160, Forwards LER 81-160/03L-0 + (02:26:14, 20 December 2024)
- ML20040E602 + (02:26:16, 20 December 2024)
- 05000324/LER-1982-001-03, /03L-0:on 820103,isolation Valve 2-E51-F043D, Failed in Open Position During Operability Cycling Test of PT-2.2.1a.Caused by Loose Cable Connector on Valve Control Switch Module.Connector Tightened + (02:26:19, 20 December 2024)
- ML20040E600 + (02:26:20, 20 December 2024)
- 05000237/LER-1981-036-03, While Performing Auto Blowdown Permissive Surveillance 287-1,pressure Switch PS3-1554E Would Not Operate at Required Pressure.Caused by Plugged Instrument Snubber.Snubber Cleaned + (02:26:22, 20 December 2024)
- 05000324/LER-1982-001, Forwards LER 82-001/03L-0 + (02:26:24, 20 December 2024)
- ML20040E593 + (02:26:25, 20 December 2024)
- ML20040E592 + (02:26:26, 20 December 2024)
- ML20040E589 + (02:26:29, 20 December 2024)
- ML20040E587 + (02:26:30, 20 December 2024)
- ML20040E588 + (02:26:30, 20 December 2024)
- ML20040E586 + (02:26:31, 20 December 2024)
- ML20040E584 + (02:26:32, 20 December 2024)
- ML20040E583 + (02:26:33, 20 December 2024)
- 05000315/LER-1981-065-03, /03L-0:on 811230,w/RCS in Mode 4 & Being Cooled Down,Low Flow Alarm for Containment Air Particulate & Gaseous Detectors Received.Cause Unknown.Pump Started Locally,W/Filter Paper Clean & Valve Lineup Correct + (02:26:34, 20 December 2024)
- 05000315/LER-1981-064-03, /03L-0:on 811229,during Normal Operation,Isolation Valve WCR-922 Failed to Meet Required Closing Time of 10-s. Caused by Tight Valve Packing.Valve Repacked.Packing Gland Nuts Loosened + (02:26:36, 20 December 2024)
- ML20040E580 + (02:26:37, 20 December 2024)
- PNO-III-82-013A, on 820130,Region III Informed by News Media That Chicago Chapter of Greenpeace Environ Organization Had Claimed Responsibility for Threats Against Facilities.Natl Organization Disavowed Support for Incident + (02:26:39, 20 December 2024)
- ML20040E577 + (02:26:39, 20 December 2024)
- ML20040E576 + (02:26:41, 20 December 2024)
- ML20040E575 + (02:26:42, 20 December 2024)
- PNO-II-82-013, on 820129,leak Discovered of Less than 1 Gpm from Small Crack on Line 3/4 Inch from Weld Connecting Line to Reactor Coolant Pump Seal Assembly.Unit Proceeding to Cold Shutdown for Repair + (02:26:44, 20 December 2024)
- ML20040E573 + (02:26:45, 20 December 2024)
- PNO-II-82-013A, on 820201,licensee Determined Exact Nature of Two Leaks;One Leak Identified as nonisolable,through- Wall Leak on 2-1/2 inch,pipe-to-valve Weld in Makeup Pipe to Rcs,Other Leak in Pump Seal Casing + (02:26:48, 20 December 2024)
- ML20040E571 + (02:26:49, 20 December 2024)
- ML20040E570 + (02:26:50, 20 December 2024)
- ML20040E568 + (02:26:51, 20 December 2024)
- ML20040E566 + (02:26:52, 20 December 2024)
- ML20040E564 + (02:26:53, 20 December 2024)
- ML20040E561 + (02:26:58, 20 December 2024)
- ML20040E560 + (02:26:59, 20 December 2024)