- ML20237H675 + (12:14:03, 2 December 2024)
- IR 05000124/1987001 + (12:14:04, 2 December 2024)
- ML20237H671 + (12:14:05, 2 December 2024)
- NRC-87-0140, Responds to Violations Noted in Insp Rept 50-341/87-22 Re Jamesbury Butterfly Valves.Valves Repaired Following Individual Failures.Remaining Carbon Steel Shafts & Wafers in Jamesbury Valves Will Be Replaced W/Stainless Steel Matl + (12:14:05, 2 December 2024)
- 05000302/LER-1987-014-02, :on 870722,oncoming Shift Supervisor Discovered That Daily Heat Balance Calculation Not Performed within Allowable Surveillance Window of Tech Spec 4.3.1.1.1.Caused by Personnel Error.Personnel Counseled + (12:14:07, 2 December 2024)
- ML20237H666 + (12:14:08, 2 December 2024)
- 05000312/LER-1987-038, :on 870715,decay Heat Pump a Tripped Due to Closure of Pump Suction Valve HV-20002.Caused by Contractor Electrician Lifting Wire That Provided Indication to Valve Control Circuit.Valve Reopened + (12:14:10, 2 December 2024)
- ML20237H662 + (12:14:11, 2 December 2024)
- ML20237H659 + (12:14:12, 2 December 2024)
- SNRC-1357, Suppl 7 to Startup Rept for 870501-0801 + (12:14:12, 2 December 2024)
- ML20237H658 + (12:14:13, 2 December 2024)
- ML20237H654 + (12:14:14, 2 December 2024)
- ML20237H656 + (12:14:14, 2 December 2024)
- TXX-6670, Interim Deficiency Rept CP-86-13 Re Computer Entry Error Which Could Invalidate Portions of Jet Impingement Load Review for High Energy Piping.Initially Reported on 860305. Next Rept to Be Submitted by 871016 + (12:14:15, 2 December 2024)
- ML20237H649 + (12:14:16, 2 December 2024)
- ML20237H648 + (12:14:16, 2 December 2024)
- ML20237H647 + (12:14:17, 2 December 2024)
- ML20237H645 + (12:14:17, 2 December 2024)
- ML20237H642 + (12:14:18, 2 December 2024)
- ML20237H641 + (12:14:19, 2 December 2024)
- ML20237H638 + (12:14:19, 2 December 2024)
- ML20237H634 + (12:14:37, 2 December 2024)
- ML20237H633 + (12:14:37, 2 December 2024)
- IR 05000269/1987028 + (12:14:38, 2 December 2024)
- ML20237H629 + (12:14:39, 2 December 2024)
- IR 05000321/1987020 + (12:14:40, 2 December 2024)
- ML20237H622 + (12:14:41, 2 December 2024)
- ML20237H623 + (12:14:41, 2 December 2024)
- ML20237H620 + (12:14:42, 2 December 2024)
- ML20237H616 + (12:14:43, 2 December 2024)
- ML20237H615 + (12:14:43, 2 December 2024)
- ML20237H614 + (12:14:44, 2 December 2024)
- ML20237H607 + (12:14:45, 2 December 2024)
- ML20237H606 + (12:14:45, 2 December 2024)
- ML20237H604 + (12:14:46, 2 December 2024)
- ML20237H602 + (12:14:47, 2 December 2024)
- ML20237H598 + (12:14:47, 2 December 2024)
- ML20237H597 + (12:14:48, 2 December 2024)
- ML20237H593 + (12:14:49, 2 December 2024)
- ML20237H592 + (12:14:50, 2 December 2024)
- ML20237H589 + (12:14:57, 2 December 2024)
- ML20237H586 + (12:14:58, 2 December 2024)
- ML20237H584 + (12:14:59, 2 December 2024)
- ML20237H581 + (12:14:59, 2 December 2024)
- ML20237H579 + (12:15:00, 2 December 2024)
- ML20237H577 + (12:15:01, 2 December 2024)
- ML20237H576 + (12:15:01, 2 December 2024)
- ML20237H572 + (12:15:02, 2 December 2024)
- ML20237H571 + (12:15:03, 2 December 2024)
- U-601005, Monthly Operating Rept for Jul 1987 + (12:15:03, 2 December 2024)
- ML20237H567 + (12:15:04, 2 December 2024)
- B12640, Confirms That Piping Stress Analysis Considered Eccentric Mass of New Valves & Operators Being Installed as Part of ECCS Mods,Per NRC 870811 Telcon Request + (12:15:10, 2 December 2024)