| Person / Time | |
|---|---|
| Site: | McGuire, Mcguire |
| Issue date: | 08/17/1987 |
| From: | Hood D Office of Nuclear Reactor Regulation |
| To: | Tucker H DUKE POWER CO. |
| References | |
| GL-87-08, GL-87-8, TAC-65372, TAC-65373, NUDOCS 8708250093 | |
| Download: ML20237H642 (3) | |
Text
- - _ _ _ _ - _ _.
w Docket Nos.: 50-369/370 L
i i
Mr. Hal B. Tucker Vice President, Nuclear Production 400 17 %
Duke Power Company I
i P.O. Box 33189 422 South Church Street 1
{
Charlotte, North Carolina 28242 t
Dear Mr. Tucker:
(TACS65372/65373)
This is to acknowledge receipt of the Duke Power Company letter dated December 2, 1986, which transmitted a proposed amendment to the William B. McGuire Nuclear Station Units 1 and 2, Physical Security Plan in response to the Miscellaneous Amendments and Search Requirements.
The submitted document has been reviewed and we have determined that additional information and revisions to the plan are required prior to our approval.
The enclosed comments are based upon pertinent NRC regulations and published guidance l
describing methods, acceptable to the NRC staff, for implementing specific parts of those regulations.
1 It is requested that you provide your response to these conments within 30 days from receipt of this letter.
The reporting and/or record keeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.
1 Should you have any questions concerning the enclosed comments, please l
contact the reviewer, Jane Gibson, at (301) 492-8457.
Sincerely,
/ s/
Darl Hood, Project Manager Project Directorate 11-3 Division of Reactor Projects I-II Office of Nuclear Reactor Regulation
Enclosure:
DISTRIBUTION W/ ENCLOSURES:
Physical Security Plan Comments R5GB rt Sec rf JGibson CBuracker (2) cc w/ enclosure:
Region II MDuncan See next page DHood Docket File 50-369/370 8708250093 870817 Case File NRC PDR PDR ADOCK 05000369 RErickson w/o encl Local PDR F
PDR LBush w/o encl o SEE PREVIOUS CONCURRENCE PAGE
) SA/
OFC :RSbB *
- R5GB
- R5GB
- R5GB
- PD 11-#
- PD 11-3
_ _ _ _ :....... _ _ _. :.... _ _ _ _ _ _ _ :. _ _......... :... _ _ _ _ _ _ _ _ _ :.y. y..___:..._..______:__.......
NAME :JGibson/an :CBuracker
- LBush
- RErickson
- MDu cah
- DHood DATE :8/12/87
- 8/12/87
- 8/13/87
- 8/13/87
- 8//7/87
- 8g/87 OFFICIAL RECORD COPY
m Mr. H. B. Tucker Duke Power Company McGuire Nuclear Station cc:
Mr. A.V. Carr, Esq.
Dr. John M.-Barry Duke Power Company Department of Environmental Health P. O. Box 33189 Mecklenburg County 422 South Church Street
-1200 Blythe Boulevard Charlotte, North Carolina 28242 Charlotte, North Carolina TP203 i
County Manager of Mecklenburg County 720 East Fourth Street Charlotte, North Carolina 28202 Chairman, North Carolina Utilities Commission Mr. Robert Gill Dobbs Building l
Duke Power Company 430 North Salisbury Street Nuclear Production Department Raleigh, North Carolina.27602 i
P. O. Box 33189 1
Charlotte, North Carolina 28242 Mr. Dayne H. Brown, Chief l
Radiation Protection Branch J. Michael McGarry, III, Esq.
Division of Facility Services l
Bishop, Liberman,- Cook, Purcell Department of Human Resources and Reynolds 701 Barbour Drive 1200 Seventeenth Street, N.W.
Raleigh, North Carolina 27603-2008 Washington, D. C.
20036 Senior Resident inspector c/o U.S. Nuclear Regulatory Commission Route 4, Box 529 i
Hunterville, North Carolina 28078 Regional Administrator, Region II U.S. Nuclear Regulatory Commission, 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 L. L. Williams Area Manager, Mid-South Area ESSD Projects Westinghouse Electric Corporation MNC West Tower - Bay 239 P. O. Box 355 i
Pittsburgh, Pennsylvania 15230 i
- ~
l
~
l Docket No. 50-369/370 WILLIAM B. McGUIRE NUCLEAR STATION, UNITS 1 AND 2 COMMENTS ON PHYSICAL SECURITY PLAN CHANGES (MISCELLANEOUS AMENDMENTS AND SEARCH REQUIREMENTS)
Provide a schedule for implementing the amended safeguards requirements.
Reference 10 CFR 73.55.
1 State that vital area access controls will not be dropped for life threatening I
situations not involving public health and safety.
Reference 10 CFR 50.54(x) and (y) and Generic Letter 87-08 (Q&A #3).
Provide a commitment that if security force members leave the protected area to perform official duties subsequent to their initial entry and search, they will be searched prior to re-entry into the protected area if they have not been under direct observation or accompanied by another member of the security force.
Reference 10 CFR 73.55(d)(1) and Generic Letter 87-08 (Q&A #11).
Provide a commitment that the secondary power supply systems for both the alarm annunciator equipment and non portable communications equipment shall be located within a vital area.
Reference 10 CFR 73.55(e)(1) and Generic Letter 87-08 (Q&A #16).
Indicate what components of the secondary power supply system will be protected i
as vital.
Reference 10 CFR 73.55(e)(1) and Generic Letter 87-08 (Q&A #18).