Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20063E273 + (02:57:58, 17 December 2024)
- ML20063E274 + (02:57:58, 17 December 2024)
- ML20063E271 + (02:57:59, 17 December 2024)
- 05000249/LER-1982-024-03, /03L-0:on 820604,during Auto Blowdown Permissive Surveillance Dis 287-1,pressure Switch 155D Would Not Trip. Caused by Leaking Internal Diaphragm.Switch Replaced & Tested + (02:58:01, 17 December 2024)
- 05000373/LER-1982-044, Forwards LER 82-044/03L-0 + (02:58:02, 17 December 2024)
- ML20063E260 + (02:58:02, 17 December 2024)
- 05000373/LER-1982-054, Forwards LER 82-054/03L-0 + (02:58:03, 17 December 2024)
- ML20063E258 + (02:58:03, 17 December 2024)
- 05000237/LER-1982-020-03, /03L-0:on 820609,approx 200 Gallons Concentrated Waste Found Leaking Onto First Floor of Max Recycle Bldg During Sampling Procedure.Caused by Failed Diaphragm on 1.5-inch Dump Valve AO-2/3-2012-217B + (02:58:05, 17 December 2024)
- 0CAN019410, Forwards Rev 17 to Emergency Plan for Ano + (02:58:06, 17 December 2024)
- ML20063E238 + (02:58:10, 17 December 2024)
- ML20063E240 + (02:58:10, 17 December 2024)
- ML20063E235 + (02:58:11, 17 December 2024)
- 05000249/LER-1982-024, Forwards LER 82-024/03L-0 + (02:58:12, 17 December 2024)
- ML20063E234 + (02:58:12, 17 December 2024)
- ML20063E221 + (02:58:13, 17 December 2024)
- ML20063E225 + (02:58:13, 17 December 2024)
- 05000321/LER-1982-064-03, /03L-0:on 820718,reactor Water Cleanup Sys Primary Containment Outboard Isolation Valve Opened While Sys Inoperable.Caused by Personnel Failure to Clear Outstanding Limiting Condition for Operation Prior to Opening Valve + (02:58:16, 17 December 2024)
- 05000321/LER-1982-064, Forwards LER 82-064/03L-0 + (02:58:17, 17 December 2024)
- ML20063E213 + (02:58:17, 17 December 2024)
- 05000373/LER-1982-037-03, /03L-0:on 820608,Group IV Div 1 Isolation Signal Initiated Unexpectedly.Exhaust Isolation Damper 1VR05YB Failed to Close & Intake Isolation Damper Closed But Failed to Reopen.Caused by Damper Vanes Wedging Against Gasket + (02:58:19, 17 December 2024)
- 05000237/LER-1982-020, Forwards LER 82-020/03L-0.Detailed Event Analysis Encl + (02:58:20, 17 December 2024)
- 05000373/LER-1982-037, Forwards LER 82-037/03L-0 + (02:58:21, 17 December 2024)
- ML20063E184 + (02:58:22, 17 December 2024)
- ML20063E187 + (02:58:22, 17 December 2024)
- ML20063E179 + (02:58:23, 17 December 2024)
- ML20063E173 + (02:58:24, 17 December 2024)
- ML20063E172 + (02:58:24, 17 December 2024)
- ML20063E169 + (02:58:25, 17 December 2024)
- 05000321/LER-1982-068-03, /03L-0:on 820804,reactor Core Isolation Cooling Flow Instrument Switch Failed to Actuate Properly.Caused by Dust & Dirt Accumulation on Switch.Switches Cleaned & Recalibr + (02:58:30, 17 December 2024)
- ML20063E165 + (02:58:31, 17 December 2024)
- ML20063E167 + (02:58:31, 17 December 2024)
- ML20063E163 + (02:58:32, 17 December 2024)
- ML20063E164 + (02:58:32, 17 December 2024)
- ML20063E161 + (02:58:33, 17 December 2024)
- 05000361/LER-1982-067-01, /01T-0:on 820720,while in Mode 3,second Auxiliary Feedwater Sys Train Rendered Inoperable Due to Inability of Valve 2HV4713 to Open Fully.Caused by Loose Coupling Lock Nut Allowing Actuator Shaft to Separate from Valve Stem + (02:58:35, 17 December 2024)
- 05000321/LER-1982-068, Forwards LER 82-068/03L-0 + (02:58:36, 17 December 2024)
- ML20063E155 + (02:58:36, 17 December 2024)
- ML20063E144 + (02:58:37, 17 December 2024)
- 05000361/LER-1982-066-01, /01T-0:on 820719,while in Mode 3,auxiliary Feedwater Sys Train Vendered Inoperable Due to Inability of Valve 2HV4706 to Open Fully.Caused by Bent & Jammed Antirotation Plate/Mechanical Indicator Against Yoke Guides + (02:58:38, 17 December 2024)
- ML20063E140 + (02:58:39, 17 December 2024)
- 05000361/LER-1982-066, Forwards LER 82-066/01T-0 & 82-067/01T-0.Detailed Event Analysis Submitted + (02:58:40, 17 December 2024)
- ML20063E139 + (02:58:40, 17 December 2024)
- 05000331/LER-1982-038-03, /03L-0:on 820610,suppression Chamber to Drywell Vacuum Breaker Valve CV-4327D Opened & Failed to Close. Caused by Stuck Pneumatic Cylinder in Midposition,Due to Crud Accumulation.New O-rings,seals & Gaskets Installed + (02:58:42, 17 December 2024)
- 05000324/LER-1982-097-03, /03L-0:on 820727,review of Time Response Test Procedures for Reactor Water Cleanup Low Level 2 Isolation, Revealed Armature Travel Time for Last Relay in Logic Chain Not Timed.Caused by Improper Terminals.Procedures Revised + (02:58:44, 17 December 2024)
- 05000247/LER-1982-025-03, /03L-0:on 820530,steam Generator 21 Level Indicators Drifted Upscale.Caused by Foxboro Co Transmitter 417C Failure.Bistables Associated W/Reactor Protection Sys Placed in Trip Condition + (02:58:46, 17 December 2024)
- 05000331/LER-1982-038, Forwards LER 82-038/03L-0 + (02:58:47, 17 December 2024)
- 05000324/LER-1982-097, Forwards LER 82-097/03L-0 + (02:58:48, 17 December 2024)
- ML20063E112 + (02:58:48, 17 December 2024)
- ML20063E111 + (02:58:49, 17 December 2024)
- ML20063E109 + (02:58:49, 17 December 2024)