Enclosure 1 to Serial: RSEP/82-Il90 OPERATING DATA REPORT
.o.
DOCKET NO: 50-261-DATE: 820702 COMPLETED BY: H. Ray Norris TELEPHONE: (803) 383-4524 OPERATING STATUS Notes:
- 1. Unit Name:
H._B. Robinson Unit No. 2 There are presently 157 spent
- 2. Reporting Period: _820601. 0000/820630. 2400 fuel assemblies in the spent
- 3. Licensed Thermal Power (FMt): 2300 fuel pool
- 4. Nameplate Rating (Gross F?.le):
739
- 5. Design Electrical Rating (Net FMe): 7,00
- 6. Maximum Dependable Capacity (Gross FMe): 700 l
- 7. Maximum Dependable Capacity (Net FMe):
665
- 8. If Changes Occur in Capacity Ratings (Item Number 3 through 7) Since Last Report, Give Reasons:
No change i
- 9. Power Level to Which Restricted, If Any (Net FMe): Approximately 535 (80% reactor power)
I
- 10. Reasons For Restrictions, If Any: Although the unit is not restricted by any outside
(
agency, the power level is presently reduced due to steam generator considerations.
t This Month Yr.-to-Date Cumulative d
- 11. Ilours in Reporting Period 720 4,343 99,269
- 12. Number of Hours Reactor Was Critical 0
1,367.1 73,712.52 l
- 13. Reactor Reserve Shutdown llours 0
0 1,085.30 l
- 14. Ilours Generator On-Line 0
1.367.1 71.922.41
- 15. Unit Reserve Shutdown llours 0
0 23.20
- 16. Gross Thermal Energy Generated (FMil) 0 2.501,310 145,596,684
- 17. Gross Electrical Energy Generated (FMil) 0 798,330 46,876,300 j
- 18. Net Electrical Energy Generated (FMil)
-2831 742,597 44,362,848
- 19. Unit Service Factor 0
31.47 72.45
- 20. Unit Availability Factor 0
31.47 72.47
- 21. Unit Capacity Factor (Using MDC Net)
-0.59 25.71 67.20
- 22. Unit Capacity Factor (Using DER Net)
-0.56 24.42 63.84
- 23. Unit Forced Outage Rate 0
0 14.35
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
None.
- 25. If Shut Down At End of Report Period, Estimated Date of Startup: July 20, 1982
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved
~~
INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION (9/77) 8207130306 820709 sg PDR ADOCK 05000261 R
Enclosure No. 2 to Ser*g RSEP/82-1190 AVERAGE DAILY UNIT POWER LEVEL t
DOCKET NO.
50-261 UNIT WO 820702 DATE COMPLETED BY H-Rny Norris TELEPHONE (803) 383-4524 MONTH JUNE DAY AVERAGE DAILY POWER LEVEL DAY AVER AGE DAILY POWER LEVEL -
(MWe-Net)
(MWe-Net) 0 0
1
,7 0
2 0
33 0
3 0
39 4
0 0
20 5
n 21 n
0 o
6 7
0 23 0
0 0
8 4
0 9
25 10 0
26 0
11 0
0 27 12 0
23 0
13 0
0 39 0
0 14 30 15 0
3; 16 0
INSTRUCTIONS On this format,hst the average daily unit power level in MWe. Net for each day in the reporting month. Compute to e.
,j the nearest whole megawatt.
a,;,;
4 v
(9/77)
- ) > i$
'Mf!
c.
GhsQ
,;;,,s w q,y & 9n w,a.u+,<
_ _ __ _ to Serial: RSEP/82-1190 50-261 DOCKET NO.
UNIT S!!UTDOWNS AND POWER ;tEDUC110NS H.
B.
Robinson UNIT NAME 820/02 DATE COMPLETED 1:Y H. Rnv Norris REPORT MONTl!
JUNE TEl.LPl!ONE ( Ann 191 Aus e.
Iy
.h E Licensee
,h Cause & Currective No.
Date g
3g i
,j j$
Event
??
fs Action su jU Prebent Recuricace f3 Repori #
JiV 6-Q 02-01 820601 S
720 B/C 3
ZZ ZZZZZZ Shutdown for maintenance / refueling outage.
i 1
?
s l
I 2
3 4
F: Forced Reason:
Methot::
Exhibit G Instructions S: Sst:edu!cd A-Eituipment Failure (Explain) 1-Manus!
for Preparation of Data Il Maintensnee or Test 2 Manu21 Scram.
Enity Sheets for 1.ieensee C. Refueling 3 Automatic Scram.
Event Iteport (l.I'11) I,le (NUREG-D-Hegula:ory Restriction 4 Other (Exrlain) 016:)
1;-Operator Tr:.ining & License Examinatiim F /.dnuaistra:ive 5
Exhibit I-Saine Source G Operational Enor (Explain)
('s/77) -
Il-Ot her (E xplain) e
)