Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000317/LER-1982-064-03, /03L-0:on 821014,during Surveillance Testing, Refueling Water Tank Inadvertently Drained to Spent Fuel Pool to Level of 455 Inches.Caused by Missed Step During Performance of Surveillance Test.Operator Reinstructed + (16:48:13, 16 December 2024)
- ML20066K401 + (16:48:14, 16 December 2024)
- 05000387/LER-1982-035, Forwards LER 82-035/03L-0 + (16:48:15, 16 December 2024)
- 05000346/LER-1982-055, Forwards LER 82-055/03L-0 + (16:48:17, 16 December 2024)
- ML20066K397 + (16:48:17, 16 December 2024)
- ML20066K389 + (16:48:23, 16 December 2024)
- ML20066K387 + (16:48:24, 16 December 2024)
- 05000317/LER-1982-064, Forwards LER 82-064/03L-0 + (16:48:25, 16 December 2024)
- ML20066K375 + (16:48:26, 16 December 2024)
- ML20066K369 + (16:48:27, 16 December 2024)
- ML20066K370 + (16:48:27, 16 December 2024)
- ML20066K359 + (16:48:30, 16 December 2024)
- ML20066K355 + (16:48:32, 16 December 2024)
- ML20066K357 + (16:48:32, 16 December 2024)
- ML20066K347 + (16:48:33, 16 December 2024)
- ML20066K351 + (16:48:33, 16 December 2024)
- 05000361/LER-1982-127-01, /01T-0:on 821102,both Trains of Iodine Removal Sys Found Inoperable.Caused by Design Error in Temporary Mod on Low Level Cutoff Controls Made to Spray Chemical Tank T-105 on 821019 & Improperly Installed Heat Tracing.Mod Cor + (16:48:35, 16 December 2024)
- ML20066K338 + (16:48:36, 16 December 2024)
- 05000261/LER-1982-015-03, /03L-0:on 821019,during Performance of Periodic Test,Comparator LC-485A Found Inoperable.Cause Not Determined.Defective Comparator Replaced W/Spare Unit + (16:48:38, 16 December 2024)
- ML20066K336 + (16:48:39, 16 December 2024)
- ML20066K335 + (16:48:40, 16 December 2024)
- ML20066K330 + (16:48:40, 16 December 2024)
- ML20066K329 + (16:48:41, 16 December 2024)
- 05000348/LER-1982-058-03, /03L-0:on 821025,during Performance of Power Range Neutron Flux Channel calibr,overtemp-delta Temp Instrumentation Loop Declared Inoperable.Caused by Dirty Contacts on Printed Circuit Card C3-125.Contacts Cleaned + (16:48:43, 16 December 2024)
- ML20066K325 + (16:48:44, 16 December 2024)
- 05000361/LER-1982-127, Forwards LER 82-127/01T-0.Detailed Event Analysis Submitted + (16:48:45, 16 December 2024)
- 05000317/LER-1982-058-03, /03L-0:on 821019,ESF Actuation Sys Sensor Channel Ze for Steam Generator 11 Pressure Failed in Tripped Condition.Caused by Voltage Drift in Transmation 230IT Isolator.Isolator Replaced + (16:48:46, 16 December 2024)
- ML20066K309 + (16:48:49, 16 December 2024)
- 05000318/LER-1982-052-03, /03L-0:on 821025,no Audible Source Range Indication Operable.All 4 Visual Indication Channels Operable.Caused by Administrative Controls Failure. Surveillance Test Procedure Corrected + (16:48:50, 16 December 2024)
- ML20066K306 + (16:48:52, 16 December 2024)
- 05000416/LER-1982-113-03, /03L-0:on 821024,smoke Detectors in East Electrical Switchgear Room & Piping Penetration Room in Auxiliary Bldg Alarmed & Would Not Reset.Cause Unknown. Surveillance Test Performed Satisfactorily + (16:48:54, 16 December 2024)
- 05000261/LER-1982-015, Forwards LER 82-015/03L-0 + (16:48:55, 16 December 2024)
- ML20066K291 + (16:48:55, 16 December 2024)
- 05000325/LER-1982-114-03, /03L-0:on 821022,comparison of Suppression Chamber Water Level Indications on RTGB Revealed Discrepancy Between Narrow & wide-range Level Instruments.Caused by Valves 1-E11-F040 & F049 Failing to Close Fully.Valves Closed + (16:48:59, 16 December 2024)
- ML20066K271 + (16:49:00, 16 December 2024)
- 05000317/LER-1982-058, Forwards LER 82-058/03L-0 + (16:49:01, 16 December 2024)
- ML20066K270 + (16:49:01, 16 December 2024)
- ML20066K267 + (16:49:02, 16 December 2024)
- 05000395/LER-1982-025-03, /03L-0:on 821020,during Performance of Surveillance Test Procedure,Porv PCV-445A Found Leaking. Caused by Degraded Seat/Disk Interface Due to Steam Impingement.Valves Will Be Repaired + (16:49:03, 16 December 2024)
- ML20066K257 + (16:49:04, 16 December 2024)
- 05000318/LER-1982-052, Forwards LER 82-052/03L-0 + (16:49:05, 16 December 2024)
- ML20066K252 + (16:49:05, 16 December 2024)
- 05000416/LER-1982-113, Forwards LER 82-113/03L-0 + (16:49:06, 16 December 2024)
- 05000336/LER-1982-041-03, /03L-0:on 821019,control Element Assembly 23 Dropped Fully Into Core.Caused by Failure of Coil Power Programmer 5-volt Dc Power Supply.Upper Gripper Power Switch Replaced + (16:49:07, 16 December 2024)
- 05000325/LER-1982-114, Forwards LER 82-114/03L-0 + (16:49:08, 16 December 2024)
- 05000395/LER-1982-025, Forwards LER 82-025/03L-0.Detailed Event Analysis Encl + (16:49:09, 16 December 2024)
- B13723, Requests Extension to Previously Filed & Approved Request for Relief from ASME Section Xi,To Allow Continued Use of Temporary Rubber Expansion Joint in Pipe Until Replacement Is Available + (16:49:09, 16 December 2024)
- ML20066K226 + (16:49:10, 16 December 2024)
- 05000272/LER-1982-082-03, /03L-0:on 821025,thermal Detectors for Iodine Removal Sys & Pressure Relief Sys Discovered Missing from Fire Detection Instrumentation Surveillance Procedures. Caused by Oversight During Procedure Inception + (16:49:12, 16 December 2024)
- ML20066K215 + (16:49:13, 16 December 2024)
- ML20066K211 + (16:49:14, 16 December 2024)