Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20072F088 + (10:28:59, 15 December 2024)
- ML20072F085 + (10:29:00, 15 December 2024)
- ML20072F076 + (10:29:00, 15 December 2024)
- ML20072F075 + (10:29:01, 15 December 2024)
- ML20072F070 + (10:29:02, 15 December 2024)
- ML20072F074 + (10:29:02, 15 December 2024)
- B10805, Application for Amend to License DPR-65,revising Tech Specs Re Repair of Defective Steam Generator Tubes Through Plugging or Sleeving + (10:29:03, 15 December 2024)
- ML20072F064 + (10:29:05, 15 December 2024)
- ML20072F060 + (10:29:07, 15 December 2024)
- 05000254/LER-1983-022-03, /03L-0:on 830523,RCIC Steam Supply Valve MO-1-1301-16 Did Not Give Open Position Indication When Operated from Control Room.Valve Found Open.Caused by Loose Wire on Open Limit Switch + (10:29:08, 15 December 2024)
- ML20072F050 + (10:29:10, 15 December 2024)
- ML20072F052 + (10:29:10, 15 December 2024)
- 05000327/LER-1983-076-03, /03L-0:on 830530,condensate Demineralizer Liquid Effluent Line Radiation Monitor O-RM-90-225 Declared Inoperable Due to Loss of Sample Flow.Caused by Normal Wear Causing Pump Failure + (10:29:12, 15 December 2024)
- BSEP-83-1875, Ro:On 830513,limiting Condition of Operation Initiated for Fire Door 202 in Diesel Generator Bldg.Door Inoperable Due to High Differential Air Pressure Encountered Across Door Preventing self-closure + (10:29:13, 15 December 2024)
- SNRC-2178, Forwards Proprietary Response to NRC Concerns Re Survey Instruments Used for Termination Survey.Extensive Discussion Provided in Interest of Rapidly Bringing Outstanding Concerns to Close.Response Withheld (Ref 10CFR2.790(a)(4)) + (10:29:14, 15 December 2024)
- ML20072F026 + (10:29:15, 15 December 2024)
- ML20072F029 + (10:29:15, 15 December 2024)
- ML20072F024 + (10:29:16, 15 December 2024)
- ML20072F019 + (10:29:16, 15 December 2024)
- ML20072F015 + (10:29:17, 15 December 2024)
- ML20072F009 + (10:29:18, 15 December 2024)
- ML20072F010 + (10:29:18, 15 December 2024)
- ML20072F007 + (10:29:19, 15 December 2024)
- ML20072F002 + (10:29:20, 15 December 2024)
- ML20072E998 + (10:29:20, 15 December 2024)
- ML20072E995 + (10:29:21, 15 December 2024)
- ML20072E991 + (10:29:22, 15 December 2024)
- ML20072E990 + (10:29:22, 15 December 2024)
- ML20072E988 + (10:29:23, 15 December 2024)
- 05000369/LER-1983-031-03, /03L-0:on 830512,reactor Coolant Pump Taken Out of Svc Following Sporadic Low Oil Level Alarms from Pump Motor 1D Upper Reservoir.Level Found Slightly Low.Cause Not Determined.Oil Added.Pump Restarted + (10:29:24, 15 December 2024)
- ML20072E985 + (10:29:25, 15 December 2024)
- ML20072E982 + (10:29:26, 15 December 2024)
- ML20072E979 + (10:29:26, 15 December 2024)
- ML20072E976 + (10:29:27, 15 December 2024)
- ML20072E973 + (10:29:28, 15 December 2024)
- 05000341/LER-1994-002, :on 940714,fifteen SRV Pilot Assemblies Were Removed During Fourth Refueling Outage.Caused by SRV Setpoint Pressure Upward Drift.All Fifteen SRV Pilot Assemblies Have Been Replaced + (10:29:29, 15 December 2024)
- ML20072E969 + (10:29:30, 15 December 2024)
- ML20072E958 + (10:29:31, 15 December 2024)
- ML20072E956 + (10:29:32, 15 December 2024)
- ML20072E948 + (10:29:32, 15 December 2024)
- ML20072E942 + (10:29:33, 15 December 2024)
- ML20072E944 + (10:29:33, 15 December 2024)
- ML20072E925 + (10:29:34, 15 December 2024)
- ML20072E932 + (10:29:34, 15 December 2024)
- W3P83-1439, Advises of Planned Use of Respiratory Protective Equipment Per 10CFR20.103.Use of Equipment Not Anticipated Prior to Fuel Load + (10:29:35, 15 December 2024)
- ML20072E919 + (10:29:36, 15 December 2024)
- ML20072E915 + (10:29:37, 15 December 2024)
- ML20072E914 + (10:29:37, 15 December 2024)
- ML20072E911 + (10:29:38, 15 December 2024)
- 05000251/LER-1983-005-01, /01T-0:on 830601,mechanical Maint Supervisor Determined That safety-related Snubber Inoperable Due to Incomplete Mod to Attachment.Caused by Personnel Error & Procedure Deficiencies.Mod Completed + (10:29:39, 15 December 2024)
- ML20072E906 + (10:29:41, 15 December 2024)