- 05000373/LER-1983-110-03, /03L-0:on 830908,while Performing LES-GM-119, Undervoltage Relay 1427-AP037B Failed to Trip Consistently within Allowable Time Limits.Caused by Defective Undervoltage Relay ITE-27.Relay Replaced + (05:36:30, 15 December 2024)
- ML20078H158 + (05:36:32, 15 December 2024)
- ML20078H153 + (05:36:33, 15 December 2024)
- ML20078H144 + (05:36:36, 15 December 2024)
- ML20078H135 + (05:36:43, 15 December 2024)
- ML20078H110 + (05:36:47, 15 December 2024)
- ML20078H097 + (05:36:48, 15 December 2024)
- 05000362/LER-1983-072-03, /03L-0:on 830831,w/unit in Mode 2,containment Water Level Wide Range Train B Instrumentation Failed.Caused by Water Trapped in Column for Level Transmitter 3LT-9388-2. Instrument Recalibr & Declared Operable + (05:36:50, 15 December 2024)
- ML20078H091 + (05:36:54, 15 December 2024)
- ML20078H090 + (05:36:54, 15 December 2024)
- ML20078H088 + (05:36:55, 15 December 2024)
- ML20078H084 + (05:36:56, 15 December 2024)
- ML20078H078 + (05:36:56, 15 December 2024)
- ML20078H076 + (05:36:57, 15 December 2024)
- 05000321/LER-1983-088-03, /03L-0:on 830913,fire Protection Instrumentation Supervisory Circuit Panel 1Z43-P001 Gave Trouble Light & Alarm & Could Not Be Reset & Cleared.Caused by Improperly Closed Relays.Relays Adjusted + (05:36:58, 15 December 2024)
- RBG-41056, Provides Clarifications to LAR 91-11 Re Removal of Component Lists + (05:36:59, 15 December 2024)
- ML20078H071 + (05:37:00, 15 December 2024)
- ML20078H066 + (05:37:01, 15 December 2024)
- ML20078H067 + (05:37:01, 15 December 2024)
- 05000325/LER-1983-036-03, During Reactor Startup, Control Power Supply Fuse on Motor Operator Breaker of Sys Flow Control Valve 1-E11-F068 Blew.Caused by Broken Open Position Lamp.Fuse Replaced + (05:37:03, 15 December 2024)
- ML20078H060 + (05:37:04, 15 December 2024)
- ML20078H043 + (05:37:04, 15 December 2024)
- ML20078H029 + (05:37:05, 15 December 2024)
- U-602408, Comment Supporting NUMARC Comments on Proposed Rule 10CFR50 Re Plant Shutdown & Low Power Operations.Requests Addl Period for Public Comment Be Made Available + (05:37:05, 15 December 2024)
- ML20078G985 + (05:37:06, 15 December 2024)
- ML20078G993 + (05:37:06, 15 December 2024)
- JPN-94-058, Forwards Revised Page 180 to 940804 Application for Amend to License DPR-59 Re Primary Containment Atmosphere Monitoring + (05:37:07, 15 December 2024)
- ML20078G978 + (05:37:07, 15 December 2024)
- ML20078G967 + (05:37:08, 15 December 2024)
- JPN-94-056, Forwards Two Requests for Relief from ASME Section XI Requirements to Perform Hydrostatic Tests of ISI Class 2 & 3 Sys + (05:37:09, 15 December 2024)
- ML20078G963 + (05:37:09, 15 December 2024)
- ML20078G954 + (05:37:10, 15 December 2024)
- ML20078G947 + (05:37:14, 15 December 2024)
- ML20078G946 + (05:37:14, 15 December 2024)
- BSEP-94-0459, Responds to Concerns Noted in Insp Repts 50-324/94-23 & 50-325/94-23.Based on Sixteen Crew Failures During Annual Operating Exams Util Performed Root Cause Analysis + (05:37:15, 15 December 2024)
- ML20078G943 + (05:37:16, 15 December 2024)
- ML20078G933 + (05:37:17, 15 December 2024)
- ML20078G932 + (05:37:18, 15 December 2024)
- ML20078G923 + (05:37:18, 15 December 2024)
- BECO-LTR-94-122, Monthly Operating Rept for Oct 1994 for Pilgrim Nuclear Power Station + (05:37:19, 15 December 2024)
- U-602368, Monthly Operating Rept for Oct 1994 for Clinton Power Station Unit 1 + (05:37:19, 15 December 2024)
- RC-95-0028, Suppl to TS Change TSP 940004 to License NPF-12,relocating Seismic Monitoring Instrumentation + (05:37:20, 15 December 2024)
- ML20078G906 + (05:37:21, 15 December 2024)
- RC-95-0029, Submits Addl Info in Support of Position on Containment Penetration Overcurrent Protection Issue.Licensee Maintains That No Safety Significance Associated W/Issue + (05:37:21, 15 December 2024)