- ML20080H814 + (03:00:26, 15 December 2024)
- ML20080H822 + (03:00:26, 15 December 2024)
- TXX-4101, Interim Deficiency Rept Re Defective Delaval Piston Skirt Castings for Diesel Generators.Piston Skirt Castings Will Be Replaced W/Casting Provided by Supplier by May 1984 + (03:00:27, 15 December 2024)
- 05000327/LER-1984-002-02, :on 840112,actuation of High Radiation Alarm Caused Auxiliary Bldg Ventilation Isolation.Caused by Voltage Spike Generating Electromagnetic Interference W/ High Radiation Causing Trip + (03:00:32, 15 December 2024)
- ML20080H798 + (03:00:33, 15 December 2024)
- ML20080H792 + (03:00:37, 15 December 2024)
- 05000289/LER-1983-046, Revised LER 83-046/01T-1:on 831214,nuclear safety-related Circuit for make-up Pump Lube Oil Pressure Trip Found Incorrectly Routed.Caused by Design Oversight.Circuits for make-up Pumps Rerouted in Raceways + (03:00:41, 15 December 2024)
- 05000278/LER-1983-022-03, /03L-0:on 831207,4 Kv Emergency Bus Undervoltage Relay IVA-127 Failed to Operate.Caused by Binding of Relay Rotating Disk Due to Dust Buildup.Relays Cleaned,Tested & Returned to Svc + (03:00:46, 15 December 2024)
- ML20080H778 + (03:00:47, 15 December 2024)
- ML20080H776 + (03:00:52, 15 December 2024)
- ML20080H766 + (03:00:53, 15 December 2024)
- RBG-16-929, Interim Deficiency Rept DR-158 Re ITE-32D Relays Supplied by Brown Boveri.Investigation Incomplete.Next Rept Will Be Provided by 840418 + (03:00:53, 15 December 2024)
- ML20080H733 + (03:00:54, 15 December 2024)
- BSEP-83-4063, Responds to NRC Ltr Re Significant Finding C Noted in IE Insp Repts 50-324/80-43 & 50-325/80-45.Corrective Actions: Improved Sys for Condensor Pit Releases Will Be Completed by 840630 + (03:00:54, 15 December 2024)
- 05000338/LER-1984-001, :on 840109,plant Shut Down Due to High RCS Unidentified Leakage.Caused by Defective Tubes & Leaking Tube Plugs.Tubes Plugged & Leaking Plugs Repaired + (03:00:56, 15 December 2024)
- ML20080H729 + (03:01:00, 15 December 2024)
- ML20080H724 + (03:01:04, 15 December 2024)
- ML20080H711 + (03:01:05, 15 December 2024)
- 3F0295-06, Submits Plans for Performing Integrated Leak Rate Testing. Current Isi/Ist Interval for Unit 3 Started in Mar 1987 & Ends in Mar 1997 + (03:01:06, 15 December 2024)
- RC-95-0040, Interim Part 21 Rept (SSH 940002) Re Failure of 27N Degraded Voltage Relay Mfg by Asea Brown Boveri + (03:01:06, 15 December 2024)
- ML20080H697 + (03:01:07, 15 December 2024)
- ML20080H696 + (03:01:08, 15 December 2024)
- RBG-41196, Updates Status of Util Response to NRC Bulletin 90-001,Suppl 1, Loss of Fill-Oil in Transmitter Mfg by Rosemount + (03:01:08, 15 December 2024)
- ML20080H689 + (03:01:12, 15 December 2024)
- ML20080H683 + (03:01:12, 15 December 2024)
- ML20080H677 + (03:01:19, 15 December 2024)
- ML20080H673 + (03:01:20, 15 December 2024)
- RC-95-0041, Forwards Technical Rept 94-3, Seismic Activity Near VC Summer Nuclear Station for Period Jul-Sept 1994 + (03:01:20, 15 December 2024)
- ML20080H667 + (03:01:21, 15 December 2024)
- ML20080H663 + (03:01:22, 15 December 2024)
- ML20080H656 + (03:01:23, 15 December 2024)
- 2CAN029505, Forwards ANO Unit 2 SG Circumferential Cracking Evaluation, Including Results of Special SG Tubing Insp Conducted During Planned mid-cycle Outage 2P95-1 + (03:01:23, 15 December 2024)
- ML20080H650 + (03:01:25, 15 December 2024)
- 05000247/LER-1983-046-03, /03L-0:on 831217,during Normal Operation,Loop 1 T Average Spiked High,Causing Reduction in Overpower,Resulting in Turbine Run Back.Caused by Defective Voltage to Current Converter.Equipment Repaired + (03:01:38, 15 December 2024)
- L-83-587, Responds to NRC Re Violations Noted in IE Insp Repts 50-335/83-34 & 50-389/83-62.Corrective Actions:All Motor Operated Valves on Locked Valve List Verified to Have Locked Wheels.Procedure Revised to Include Signature Blanks + (03:01:40, 15 December 2024)
- ML20080H632 + (03:01:40, 15 December 2024)
- W3P84-0278, Confirms Agreement W/Nrc Re Revised Submittal Schedule for Toxic Chemical Survey Results.Entire Survey & Subsequent Analyses Will Be Completed Prior to Fuel Load.New Survey Will Be Conducted Every 4 Yrs + (03:01:41, 15 December 2024)
- 05000277/LER-1983-027-03, /03L-0:on 831215,main Steam Line Temp Element TE-4913D Found to Read Low.Caused by Temp Element Out of Duct W/Retaining Bracket Bent & One Mounting Screw Broken. Temp Element Reinstalled + (03:01:43, 15 December 2024)
- ML20080H609 + (03:01:44, 15 December 2024)
- ML20080H614 + (03:01:44, 15 December 2024)
- ML20080H607 + (03:01:45, 15 December 2024)
- 05000336/LER-1995-001, :on 950118,crane Operated Over Spent Fuel Pool While Enclosure Bldg Ventilation Sys Inoperable.Caused by Inadequate or Insufficient Procedures.Ts 3.9.7,3.9.14 & 3.19.15 Will Be Reviewed for Clarifications + (03:01:47, 15 December 2024)
- 05000260/LER-1984-002-01, :on 840121,during Surveillance Testing,Operator Did Not Ensure Channel B Primary Containment Isolation Sys Reset Before Testing Channel C.Caused by Operator Error. Operator Counseled + (03:01:50, 15 December 2024)
- ML20080H595 + (03:01:53, 15 December 2024)
- ML20080H587 + (03:01:54, 15 December 2024)
- ML20080H583 + (03:01:54, 15 December 2024)
- BSEP-84-0053, Suppls Response to NRC Re Violations Noted in IE Insp Repts 50-324/83-26 & 50-325/83-26.Corrective Actions: Drawings & Procedures Revised & Walkdown of Fire Protection Sys Completed + (03:01:55, 15 December 2024)
- ML20080H578 + (03:01:55, 15 December 2024)
- 05000247/LER-1983-049-03, /03L-0:on 831221,during Surveillance Test PTM-12, Steam Generator 24 High Steam Flow Safety Injection Bistable Fc 449B Setpoint Found High.Caused by Setpoint Drift. Setpoint Readjusted + (03:01:57, 15 December 2024)
- ML20080H570 + (03:01:59, 15 December 2024)
- ML20080H567 + (03:02:00, 15 December 2024)
- ML20080H565 + (03:02:07, 15 December 2024)