Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20081K161 + (12:46:46, 14 December 2024)
- 05000374/LER-1995-004-02, :on 950228,determined That on Three Separate Occasions Between 950220-24 That Hourly Fire Watches Not Performed.Caused by Mgt Deficiency.Immediate Investigation Conducted + (12:46:48, 14 December 2024)
- ML20081K158 + (12:46:49, 14 December 2024)
- ML20081K157 + (12:46:50, 14 December 2024)
- ML20081K155 + (12:46:50, 14 December 2024)
- ML20081K147 + (12:46:53, 14 December 2024)
- 05000272/LER-1983-039-03, /03L-0:on 830904,P-250 Computer CRT Did Not Display Updated Info,Rendering RCS Subcooling Monitor Inoperable.Caused by Computer Being Electronically Locked Up.Computer Cleared & Rebootstrapped + (12:46:58, 14 December 2024)
- 05000416/LER-1983-151-03, /03L-0:on 830928,RCIC Sys Declared Inoperable Due to Surveillance Requirement 4.7.3.C.2 Not Completed within 12 H of Reactor Steam Pressure Reaching 150 Psig.Caused by Failed Ramp Module.Module Replaced + (12:47:00, 14 December 2024)
- ML20081K128 + (12:47:01, 14 December 2024)
- ML20081K125 + (12:47:02, 14 December 2024)
- 05000321/LER-1983-098-03, /03L-0:on 831007,during Performance of RHR Svc Water Operability & Rated Flow Procedure,Pump E11-C001A Failed to Maintain Required Pressure While Maintaining Rated Flow.Caused by Improper Valve Stroke + (12:47:04, 14 December 2024)
- ML20081K122 + (12:47:08, 14 December 2024)
- 05000328/LER-1983-140-03, /03L-L:on 831003,w/unit in Refueling Operations, Discovered Containment Sump Level Channels LT-63-176,-177 & -178 Out of Calibr.Caused by Air Leakage Around O-ring Seal on Oil Filled Ref Leg of Sense Lines + (12:47:09, 14 December 2024)
- ML20081K115 + (12:47:11, 14 December 2024)
- ML20081K119 + (12:47:11, 14 December 2024)
- ML20081K109 + (12:47:12, 14 December 2024)
- ML20081K103 + (12:47:13, 14 December 2024)
- FVY-83-115, Advises That Plans & Details of Facility 1983 Emergency Operations facility-emergency Plan Exercises Contained in 830706,28,0823 & 0906 Ltrs No Longer Withheld from Public Disclosure.Exercises Completed + (12:47:14, 14 December 2024)
- ML20081K101 + (12:47:14, 14 December 2024)
- 05000338/LER-1983-075-03, /03L-0:on 831013,Fire Door S54/11,between Unit 1 Turbine Bldg & Unit 2 Emergency Switchgear Room,Failed to Latch.Caused by Misaligned Striker.Continuous Fire Watch Posted.Latch Repaired + (12:47:16, 14 December 2024)
- ML20081K097 + (12:47:19, 14 December 2024)
- 05000395/LER-1983-121-03, /03L-0:on 831019,recently Installed Fire Door Near Floor Opening in Control Bldg at 448-inch Elevation Not Identified on Auxiliary Operator Log.Caused by Personnel Error.Door Added to Log + (12:47:20, 14 December 2024)
- ML20081K095 + (12:47:21, 14 December 2024)
- ML20081K079 + (12:47:22, 14 December 2024)
- ML20081K069 + (12:47:23, 14 December 2024)
- ML20081K068 + (12:47:24, 14 December 2024)
- JPN-95-016, Forwards Repts Re Core Shroud Insp & Preemptive Repair Performed During 1994-95 Refueling Outage of Plant, Nonproprietary Version of XM-19 Matl Constant Extension Rate Testing Rept Requested by NRC + (12:47:25, 14 December 2024)
- ML20081K061 + (12:47:25, 14 December 2024)
- ML20081K052 + (12:47:28, 14 December 2024)
- ML20081K045 + (12:47:28, 14 December 2024)
- ML20081K043 + (12:47:30, 14 December 2024)
- ML20081K039 + (12:47:31, 14 December 2024)
- ML20081K033 + (12:47:31, 14 December 2024)
- ML20081K028 + (12:47:32, 14 December 2024)
- 05000219/LER-1995-001, :on 950221,discovered That SW RMS Had Not Been Functionally Tested Since May 1993 Due to Inadequate Mgt Oversight.Svc Water Radiation Monitor Quarterly Functional Testing Performed + (12:47:33, 14 December 2024)
- ML20081K024 + (12:47:34, 14 December 2024)
- ML20081K020 + (12:47:35, 14 December 2024)
- ML20081K011 + (12:47:36, 14 December 2024)
- ML20081K018 + (12:47:36, 14 December 2024)
- ML20081K010 + (12:47:37, 14 December 2024)
- ML20081K009 + (12:47:38, 14 December 2024)
- ML20081K007 + (12:47:39, 14 December 2024)
- ML20081K001 + (12:47:39, 14 December 2024)
- ML20081J987 + (12:47:40, 14 December 2024)
- ML20081J997 + (12:47:40, 14 December 2024)
- ML20081J984 + (12:47:41, 14 December 2024)
- ML20081J982 + (12:47:41, 14 December 2024)
- ML20081J968 + (12:47:43, 14 December 2024)
- 05000327/LER-1995-002-01, :on 950223,Unit 1 Experienced RCS Leak at Compression Fitting Rv Level Indication Sys Line in Incore Instrument Room.Caused by Rv Level Indication Sys Instrument Line Failure.Work Requests Initiated + (12:47:45, 14 December 2024)
- BSEP-95-0142, Provides Response to NRC 941223 Request for Addl Info Re GL 92-08 Thermo-Lag 330-1 Fire Barriers, for Plant Units 1 & 2 + (12:47:46, 14 December 2024)
- 05000395/LER-1995-002, :on 950220,ESF Actuation Occurred.Caused by Personnel Error.Proper Operation of ESF Equipment Verified + (12:47:47, 14 December 2024)