- ML20086A356 + (07:52:21, 14 December 2024)
- ML20086A357 + (07:52:21, 14 December 2024)
- 05000271/LER-1976-026-03, /3L:on 760722,shock Suppressors RR-24 & RR-73, Located on Opposite Loops of Recirculation Discharge Bypass Line,Failed to Lock Up to Tension & Compression Velocity. Caused by Low Viscosity of Fluid + (07:52:23, 14 December 2024)
- ML20086A349 + (07:52:24, 14 December 2024)
- ML20086A348 + (07:52:25, 14 December 2024)
- 05000271/LER-1976-027-03, /3L:on 760816,Atkomatic Model 15840VPIMOD Containment Air Sample Valve FSO-109-75B-2 Failed to Close When Control Switch Placed in Closed Position.Caused by Filings & Dirt Accumulating Around Valve Stem + (07:52:26, 14 December 2024)
- ML20086A344 + (07:52:27, 14 December 2024)
- 05000271/LER-1976-028-03, /3L:on 760825,Fairbanks Morse Model 38TD8 1/8 Diesel Generator B Found Leaking at Fuel Header Fitting. Caused by Normal Engine Vibrations Shaking Mechanical Connection Loose.Connection Tightened + (07:52:29, 14 December 2024)
- 05000483/LER-1991-005, :on 911011,discovered That TS Normal & Emergency Personnel Containment Air Lock Door Interlock Test Not Performed Since 911006.Caused by Human Error.Step Added to Procedure Request Form + (07:52:30, 14 December 2024)
- ST-HL-AE-3922, Monthly Operating Repts for Oct 1991 for South Texas Project Units 1 & 2 + (07:52:31, 14 December 2024)
- B15236, Application for Amend to License NPF-49,relocating TS Requirements for Containment Purge Exhaust & Supply Valves from Radiation Monitoring Instrumentation TS Table to ESF Actuation Sys TS Table + (07:52:32, 14 December 2024)
- B15283, Forwards Response to NRC Re Violations Noted in Insp Repts 50-336/95-11 & 50-423/95-11 on 950320-23 & 27-30. Corrective Actions:Returned All UV Modules to Vendor That Implemented Mods to Correct Original Fabrication Error + (07:52:33, 14 December 2024)
- 05000271/LER-1976-029-03, /3L:on 760825,RHR Water Sys Pump a Discharge Check Valve Failed to Shut Properly & Allowed Pump C Discharge to Recirculate to Suction Side of Pumps.Caused by Excessive Play Between Disc & Disc Arm + (07:52:34, 14 December 2024)
- ML20086A321 + (07:52:36, 14 December 2024)
- 05000271/LER-1976-030-03, /3L:on 760826,GE Model 8HG1A02011 Drywell Atmospheric Temp Recorder TR-1-149 Failed.Caused by Broken Hub on Chart Drive Mechanism.Mechanism Rebuilt & Recorder Returned to Svc + (07:52:37, 14 December 2024)
- ML20086A312 + (07:52:38, 14 December 2024)
- NG-95-1971, Forwards Response to NRC Ltr Re Violations Noted in Insp Rept 50-331/95-05 on 950405-0509.Corrective Actions: Researched All Three of Maint Activities of Concern & Determined Calibrs Performed Correctly + (07:52:39, 14 December 2024)
- ML20086A308 + (07:52:39, 14 December 2024)
- ML20086A305 + (07:52:40, 14 December 2024)
- PY-CEI-NRR-1415, Monthly Operating Rept for Oct 1991 for Perry Nuclear Plant Unit 1 + (07:52:41, 14 December 2024)
- ML20086A302 + (07:52:41, 14 December 2024)
- 05000271/LER-1976-031-03, /3L:on 760830,static-O-ring Pressure Switch PS5-12D,Model 12N-AA4,actuated Above Tech Spec Limit.Caused by Setpoint Drift.All High Drywell Pressure Switches Reset to Lower Tolerance Band Limit + (07:52:43, 14 December 2024)
- JAFP-91-0732, Monthly Operating Rept for Oct 1991 for Ja Fitzpatrick Power Plant + (07:52:44, 14 December 2024)
- ML20086A300 + (07:52:44, 14 December 2024)
- U-601902, Monthly Operating Rept for Oct 1991 for Clinton Power Station,Unit 1 + (07:52:45, 14 December 2024)
- 05000271/LER-1976-032-01, /1T:on 760914,redundant auto-open Contact Discovered Missing from Control Logic Design for Valves V10-27A & B.Caused by Failure to Provide Redundant Logic. Logic Transferred from Valve V10-25A & B + (07:52:47, 14 December 2024)
- ML20086A287 + (07:52:54, 14 December 2024)
- ML20086A288 + (07:52:54, 14 December 2024)
- ML20086A283 + (07:52:55, 14 December 2024)
- ML20086A280 + (07:52:55, 14 December 2024)
- 05000271/LER-1976-033-03, /3L:on 760907,analysis of Two Carbon Samples from Standby Gas Treatment Train a Filter Revealed Efficiency Rating Below Tech Spec Limit.Cause Not Stated.Charcoal Filters Replaced + (07:52:57, 14 December 2024)
- ML20086A278 + (07:52:58, 14 December 2024)
- ML20086A275 + (07:52:59, 14 December 2024)
- ML20086A277 + (07:52:59, 14 December 2024)
- ML20086A271 + (07:53:00, 14 December 2024)
- 05000271/LER-1976-034-03, /3L:on 760920,exide Power Sys 250-kV Uninterruptible Power Supply a Tripped,Resulting in Loss of Voltage to Motor Control Ctr 89A.Caused by Blown Inverter Leg Fuse Due to Failed Gate Firing Modules + (07:53:01, 14 December 2024)
- ML20086A264 + (07:53:08, 14 December 2024)
- ML20086A263 + (07:53:09, 14 December 2024)
- ULNRC-03230, Application for Amend to License NPF-30.Amend Would Revise TSs to Implement Recommendations of GL 93-05 Re Reduction of SRs for Testing During Power Operation + (07:53:09, 14 December 2024)
- ML20086A257 + (07:53:10, 14 December 2024)
- 05000271/LER-1976-023-01, /1T:on 760724,false All Rods in Signal Received for Rod Manual Control Sys.Caused by Position Indicating Switch on Rod 34-07 Stuck in Closed Position Due to Failed Probe Buffer Card.Card Replaced & Tested + (07:53:12, 14 December 2024)
- ML20086A254 + (07:53:13, 14 December 2024)
- ML20086A255 + (07:53:13, 14 December 2024)
- 05000271/LER-1976-035-01, /1T:on 760920,LPCI Injection Valve RHR-25B Failed to Reopen Using Control Room Switch.Cause Not Determined. Investigation Underway by Walworth Co & Limitorque Corp + (07:53:15, 14 December 2024)
- ML20086A249 + (07:53:17, 14 December 2024)
- ML20086A250 + (07:53:17, 14 December 2024)
- 05000293/LER-1991-021, :on 911009,RCIC Declared Inoperable Due to Lack of Sufficient Battery Charger Test Data.Caused by Unavailability of Backup Battery Charger.Alarm Response Procedure for Alarm Window I4 Changed + (07:53:19, 14 December 2024)
- ML20086A243 + (07:53:20, 14 December 2024)
- 05000483/LER-1995-004, :on 950608,reactor Trip Automatically Initiated Due to Low Flow of RCS & Subsequent Trips of Pumps.Caused by Tree Limb on One Set of Transmission Lines. Limb Removed + (07:53:22, 14 December 2024)
- ML20086A237 + (07:53:23, 14 December 2024)
- 05000271/LER-1976-024-03, /3L:on 760630,drywell Air Purge Inlet Isolation Valve V-16-19-9 Found W/Seat Leakage Exceeding Tech Specs. Cause Not Determined.Valve Repaired + (07:53:24, 14 December 2024)