Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20117L601 + (02:35:27, 13 December 2024)
- ML20117L594 + (02:35:28, 13 December 2024)
- ML20117L592 + (02:35:29, 13 December 2024)
- ML20117L589 + (02:35:33, 13 December 2024)
- ML20117L587 + (02:35:33, 13 December 2024)
- ML20117L568 + (02:35:35, 13 December 2024)
- 05000457/LER-1996-004-07, :on 960523,unplanned Entry Into TS 3.0.3 Occurred.Caused by Personnel Error.Individuals Involved Counseled & Retrained + (02:35:42, 13 December 2024)
- ML20117L549 + (02:35:43, 13 December 2024)
- 05000423/LER-1996-003-01, :on 960312,temporary I-Beams Located Overhead of Recirculation Spray Sys HXs Discovered.Caused by Inadequate Work Control.Work Control Procedures Revised + (02:35:49, 13 December 2024)
- 05000423/LER-1996-002-02, :on 960310,inadequate Surveillance for Determining Shutdown Margin When Unisolating Rcl Identified. Caused by Inadequate Procedure.Procedures Revised + (02:35:52, 13 December 2024)
- W3P88-1817, Requests Enforcement Discretion in Implementation of TS 3.3.1, Reactor Protective Instrumentation + (02:35:53, 13 December 2024)
- AECM-85-0137, Documents Info Provided in 850502 Telcon Addressing Recent Containment & Drywell Mechanical Penetration Configuration Engineering Reviews & Insps at Facility.Neither Containment Nor Drywell Integrity Breached.No Tech Spec Changes Needed + (02:35:54, 13 December 2024)
- ML20117L503 + (02:35:55, 13 December 2024)
- ST-HL-AE-5467, Informs That SS Nance,Senior Reactor Operator License 43777, Has Resigned & No Longer Requires License + (02:35:56, 13 December 2024)
- ML20117L495 + (02:35:57, 13 December 2024)
- NG-96-1636, Informs That Kj Morgan,Sop 306582,no Longer Requires License + (02:35:58, 13 December 2024)
- 05000388/LER-1985-014, :on 850417,RCIC Sys Inboard Steam Supply Valve Isolated on Equipment Area High Temp.Caused by Malfunction of Temp Indicating Switch E51-N600B.Switch Replaced on 850418 & Isolation Signal Cleared + (02:35:59, 13 December 2024)
- ML20117L466 + (02:36:00, 13 December 2024)
- ML20117L459 + (02:36:01, 13 December 2024)
- ML20117L458 + (02:36:03, 13 December 2024)
- ML20117L451 + (02:36:04, 13 December 2024)
- ML20117L415 + (02:36:05, 13 December 2024)
- ST-HL-AE-5383, Responds to SALP Rept 50-498/96-99 & 50-499/96-99 for Period 940925-960323.Response Clarifies Specific Engineering Issues Re Engineering Work Activities + (02:36:05, 13 December 2024)
- ML20117L393 + (02:36:06, 13 December 2024)
- 05000341/LER-1985-004, :on 850402,fire-rated Assembly Floor Plug & CO2 Suppression Sys Boundary Removed & Fire Watch Not Initiated within 1 H.Caused by Personnel Ignorance of Requirements & Unposted Floor Plugs + (02:36:08, 13 December 2024)
- ML20117L362 + (02:36:09, 13 December 2024)
- ML20117L360 + (02:36:10, 13 December 2024)
- ML20117L356 + (02:36:11, 13 December 2024)
- 0CAN058505, Forwards Response to 841218 Request for Addl Info Re NUREG-0737,TMI Action Item II.D.1, Performance of Relief & Safety Valves. Response Supports NRC Finding That RCS Valves Function Under Design Basis Transients + (02:36:12, 13 December 2024)
- ML20117L344 + (02:36:13, 13 December 2024)
- ML20117L339 + (02:36:14, 13 December 2024)
- 05000528/LER-1985-016, :from 850323-0415,hourly Fire Patrols Not Conducted Per Tech Spec 3.7.12.Caused by Personnel Disregard for Responsibilities.Personnel Fired &/Or Replaced W/Station Staff & Logs & Monitoring Improved + (02:36:16, 13 December 2024)
- ML20117L325 + (02:36:17, 13 December 2024)
- 05000528/LER-1985-002, :on 850113,loss of Open Indication & Closing Circuit Power Occurred on Spray Pump Pond Train A.Caused by Metal Washer Left from Const Phase Shorting Out Type 752A Relay.Problem Corrected + (02:36:19, 13 December 2024)
- ML20117L295 + (02:36:20, 13 December 2024)
- ML20117L291 + (02:36:20, 13 December 2024)
- ML20117L289 + (02:36:21, 13 December 2024)
- 05000267/LER-1985-004, :on 850317,unplanned Liquid Radwaste Release of Approx 900 Gallons Occurred While Recirculating from Monitor Tank.Caused by Isolation Valve V-6241 Failure.Valve Cleaned & Verified to Isolate.Procedures Under Review + (02:36:23, 13 December 2024)
- ML20117L282 + (02:36:28, 13 December 2024)
- ML20117L285 + (02:36:28, 13 December 2024)
- ML20117L275 + (02:36:29, 13 December 2024)
- ML20117L269 + (02:36:29, 13 December 2024)
- ML20117L266 + (02:36:30, 13 December 2024)
- ML20117L265 + (02:36:31, 13 December 2024)
- 05000528/LER-1985-017, :on 850405,Trains a & B of balance-of-plant ESFAS Automatically Tripped.Caused by Inadvertent High Output When Radiation Monitor Reenergized.Sys Module Will Be Put in Bypass + (02:36:32, 13 December 2024)
- 05000461/LER-1996-009, :on 960808,inadequate Procedure Leads to Failure to Properly Implement TS Surveillance.Caused Appears to Be Misinterpretation of Ts.Cps Procedure 9065.02 Performed at Frequency Required by TS + (02:36:38, 13 December 2024)
- ML20117L260 + (02:36:39, 13 December 2024)
- ML20117L257 + (02:36:40, 13 December 2024)
- ML20117L258 + (02:36:40, 13 December 2024)
- ML20117L256 + (02:36:41, 13 December 2024)
- 05000528/LER-1985-023, :on 850406,inadvertent Actuation of ESF Sys Occurred During Electrical Surveillance Test.Caused by Technician Mistakenly Opening Breaker Not Specified in Procedure.Personnel Reinstructed + (02:36:43, 13 December 2024)